Mass spectrometer for measurements of relative ion concentrations in plasmas

A mass spectrometer which can be used to measure relative ion concentrations in a multiion component plasma has been designed for use in a strong (1-4-kG) uniform magnetic field. The spectrometer features an acceleration region which accelerates thermal ions through a series of three tantalum electrodes at a 30 deg angle to the B field, and a collection region in which ions are selectively collected, depending on the size of their gyroradii, by a cylindrical collector. Relative ion concentrations are determined from measurements of the collector current as a function of accelerating voltage. Results obtained using this instrument in a Q-machine device operated with a two-ion (Cs+/K+) component plasma are presented.

Suszcynsky, David M.↗

Aseptic Handling of the MOMA Mass Spectrometer After Dry Heat Microbial Reduction

Mars Organic Molecule Analyzer Mass Spectrometer (MOMA-MS) is an instrument in the larger MOMA instrument suite for the European Space Agency (ESA) ExoMars 2020 Rover. As a life-detection instrument on a Mars landing mission, MOMA-MS has very stringent Planetary Protection (PP) bioburden requirements. Within the MOMA instrument suite, the hardware surfaces of the sample path must be cleaned to a level of 0.03 spore/sq m. To meet this requirement, a process called Dry Heat Microbial Reduction (DHMR) is used to decrease the number of viable spores by 4 orders of magnitude. Before DHMR, the hardware is handled using standard cleanroom practices, while after DHMR, all sample path surfaces must be handled aseptically when exposed. Aseptic handling of the sample path involves a number of strategies and protocols including working only in an aseptic ISO class 5 work space, limiting the amount of time of exposure, using sterile garmenting with sterile gloves, and using sterile tools. Before work begins, the aseptic workspace will be tested for bioburden and particle fallout, and all tools that will contact sample path surfaces must be sterilized. During the exposure activity, sterile garments will be worn, sterile tools will be handled in a 2 person set up so that the operator touches only the sterile tool and not the exterior surfaces of the sterile pouch, and the environment will be monitored with active and passive fallout for bioburden and particle levels. Any breach in the planetary protection cleanliness can necessitate repeating DHMR, which not only has significant cost and schedule implications, it also become a risk to hardware that is not rated for repeated long exposures to high temperatures.

Life Detection↗

Analysis of the Pioneer Venus Large Probe Neutral Mass Spectrometer Data Yields New Insights into the Composition of Venus’ Atmosphere

We present a new analysis of mass spectral data obtained by the Pioneer Venus (PV) Large Probe Neutral Mass Spectrometer (LNMS). To analyze the LNMS data, we constructed an analytical model that accounts for spectrometer performance at each altitude, provides CO2 abundances in units of density (kg/m3), and retains the resolving power of the LNMS through use of a targeted data-fitting routine. Our results provide new insights into the composition of Venus’ atmosphere and show that densities for CO2 increase towards the surface, which is suggestive of surface outgassing. Additionally, the data reveal partial obstructions of the LNMS inlet at <17 km, which is an likely important consideration for future missions. Re-analysis of the LNMS data may assist in revealing the past, present and/or future habitability of Venus’ clouds.

mass spectral data↗

Neutral Mass Spectrometer (NMS) for the Lunar Atmosphere and Dust Environment Explorer (LADEE) Mission

The Lunar Atmosphere and Dust Environment Explorer (LADEE) mission currently scheduled for launch in early 2013 aboard a Minotaur V will orbit the moon at a nominal periselene of 50 km to characterized the lunar atmosphere and dust environment. The science instrument payload includes a neutral mass spectrometer as well as an ultraviolet spectrometer and a dust detector. Although to date only He, Ar-40, K, Na and Rn-222 have been firmly identified in the lunar exosphere and arise from the solar wind (He), the lunar regolith (K and Na) and the lunar interior (Ar-40, Rn-222), upper limits have been set for a large number of other species, LADEE Neutral Mass Spectrometer (NMS) observations will determine the abundance of several species and substantially lower the present upper limits for many others. Additionally, LADEE NMS will observe the spatial distribution and temporal variability of species which condense at nighttime and show peak concentrations at the dawn terminator (e,g, Ar-40), possible episodic release from the lunar interior, and the results of sputtering or desorption processes from the regolith. In this presentation, we describe the LADEE NMS hardware and the anticipated science results.

Collier, Michael R.↗

Development of a Robust, High Current, Low Power Field Emission Electron Gun for a Spaceflight Reflectron Time-of-Flight Mass Spectrometer

Carbon materials, including carbon nanotubes (CNTs) and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD), have been of considerable interest for field emission applications for over a decade. In particular, robust field emission materials are compelling for space applications due to the low power consumption and potential for miniaturization. A reflectron time-of-flight mass spectrometer (TOF-MS) under development for in situ measurements on the Moon and other Solar System bodies uses a field emitter to generate ions from gaseous samples, using electron ionization. For these unusual environments, robustness, reliability, and long life are of paramount importance, and to this end, we have explored the field emission properties and lifetime of carbon nanotubes and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD) thin films, the latter developed and patented by Argonne National Laboratory. We will present recent investigations of N-UNCD as a robust field emitter, revealing that this material offers stable performance in high vacuum for up to 1000 hours with threshold voltage for emission of about 3-4 V/lJm and current densities in the range of tens of microA. Optimizing the mass resolution and sensitivity of such a mass spectrometer has also been enabled by a parallel effort to scale up a CNT emitter to an array measuring 2 mm x 40 mm. Through simulation and experiment of the new extended format emitter, we have determined that focusing the electron beam is limited due to the angular spread of the emitted electrons. This dispersion effect can be reduced through modification of the electron gun geometry, but this reduces the current reaching the ionization region. By increasing the transmission efficiency of the electron beam to the anode, we have increased the anode current by two orders of magnitude to realize a corresponding enhancement in instrument sensitivity, at a moderate cost to mass resolution. We will report recent experimental and modeling results to describe the performance of a field emission electron gun as employed in the Volatile Analysis by Pyrolysis of Regolith (VAPoR) TOF-MS prototype.

Southard, Adrian E.↗

Installation protocol for charge transfer dissociation mass spectrometry on ion trapping mass spectrometers

Abstract Rationale Charge transfer dissociation (CTD) is a novel fragmentation technique that demonstrates enhanced structural characterization for a wide variety of molecules compared to standard fragmentation techniques like collision‐induced dissociation (CID). Alternative fragmentation techniques, such as electron transfer dissociation, electron capture dissociation, and ultraviolet photodissociation, also overcome many of the shortfalls of CID, but none of them are a silver bullet that can adequately characterize a wide variety of structures and charge states of target compounds. Given the diversity of structural classes and their occasional obstinance towards certain activation techniques, alternative fragmentation techniques are required that rely on novel or alternative modes of activation. Methods Herein, we present a step‐by‐step protocol for the installation of CTD on a quadrupole ion trap mass spectrometer and best practices for optimizing the signal‐to‐noise ratio and acquisition times for CTD mass spectra. Results In addition to two CTD installations in the Jackson laboratory, CTD has also been installed, and is currently in operation, on two 3D ion trap mass spectrometers in France: one in the laboratory of Dr. David Ropartz and Dr. Hélène Rogneaux at INRAE in Nantes, and the other in the laboratory of Dr. Jean‐Yves Salpin at Université d'Évry Val‐d'Essonne, part of the Paris‐Saclay University system. Conclusions Here, we provide a visual protocol to help others accomplish the instrument modification.

47 OTHER INSTRUMENTATION↗

Miniature Time-of-Flight Mass Spectrometer

Major advances must occur to protect astronauts from prolonged periods in near-zero gravity and high radiation associated with extended space travel. The dangers of living in space must be thoroughly understood and methods developed to reverse those effects that cannot be avoided. Six of the seven research teams established by the National Space Biomedical Research Institute (NSBRI) are studying biomedical factors for prolonged space travel to deliver effective countermeasures. To develop effective countermeasures, each of these teams require identification of and quantitation of complex pharmacological, hormonal, and growth factor compounds (biomarkers) in humans and in experimental animals to develop an in-depth knowledge of the physiological changes associated with space travel. At present, identification of each biomarker requires a separate protocol. Many of these procedures are complicated and the identification of each biomarker requires a separate protocol and associated laboratory equipment. To carry all of this equipment and chemicals on a spacecraft would require a complex clinical laboratory; and it would occupy much of the astronauts time. What is needed is a small, efficient, broadband medical diagnostic instrument to rapidly identify important biomarkers for human space exploration. The Miniature Time-Of- Flight Mass Spectrometer Project in the Technology Development Team is developing a small, high resolution, time-of-flight mass spectrometer (TOFMS) to quantitatively measure biomarkers for human space exploration. Virtues of the JHU/APL TOFMS technologies reside in the promise for a small (less than one cubic ft), lightweight (less than 5 kg), low-power (less than 50 watts), rugged device that can be used continuously with advanced signal processing diagnostics. To date, the JHU/APL program has demonstrated mass capability from under 100 to beyond 10,000 atomic mass units (amu) in a very small, low power prototype for biological analysis. Further, the electronic nature of the TOFMS output makes it ideal for rapid telemetry to earth for in-depth analysis by ground support teams.

Potember, Richard S.↗

Analytical Techniques for Retrieval of Atmospheric Composition with the Quadrupole Mass Spectrometer of the Sample Analysis at Mars Instrument Suite on Mars Science Laboratory

The Sample Analysis at Mars (SAM) instrument suite is the largest scientific payload on the Mars Science Laboratory (MSL) Curiosity rover, which landed in Mars׳ Gale Crater in August 2012. As a miniature geochemical laboratory, SAM is well-equipped to address multiple aspects of MSL׳s primary science goal, characterizing the potential past or present habitability of Gale Crater. Atmospheric measurements support this goal through compositional investigations relevant to martian climate evolution. SAM instruments include a quadrupole mass spectrometer, a tunable laser spectrometer, and a gas chromatograph that are used to analyze martian atmospheric gases as well as volatiles released by pyrolysis of solid surface materials (Mahaffy et al., 2012). This report presents analytical methods for retrieving the chemical and isotopic composition of Mars׳ atmosphere from measurements obtained with SAM׳s quadrupole mass spectrometer. It provides empirical calibration constants for computing volume mixing ratios of the most abundant atmospheric species and analytical functions to correct for instrument artifacts and to characterize measurement uncertainties. Finally, we discuss differences in volume mixing ratios of the martian atmosphere as determined by SAM (Mahaffy et al., 2013) and Viking (Owen et al., 1977, Oyama and Berdahl, 1977) from an analytical perspective. Although the focus of this paper is atmospheric observations, much of the material concerning corrections for instrumental effects also applies to reduction of data acquired with SAM from analysis of solid samples.

quadropole mass spectometer↗

Higher Order Parametric Excitation Modes for Spaceborne Quadrupole Mass Spectrometers

This paper describes a technique to significantly improve upon the mass peak shape and mass resolution of spaceborne quadrupole mass spectrometers (QMSs) through higher order auxiliary excitation of the quadrupole field. Using a novel multiresonant tank circuit, additional frequency components can be used to drive modulating voltages on the quadrupole rods in a practical manner, suitable for both improved commercial applications and spaceflight instruments. Auxiliary excitation at frequencies near twice that of the fundamental quadrupole RF frequency provides the advantages of previously studied parametric excitation techniques, but with the added benefit of increased sensed excitation amplitude dynamic range and the ability to operate voltage scan lines through the center of upper stability islands. Using a field programmable gate array, the amplitudes and frequencies of all QMS signals are digitally generated and managed, providing a robust and stable voltage control system. These techniques are experimentally verified through an interface with a commercial Pfeiffer QMG422 quadrupole rod system.When operating through the center of a stability island formed from higher order auxiliary excitation, approximately 50% and 400% improvements in 1% mass resolution and peak stability were measured, respectively, when compared with traditional QMS operation. Although tested with a circular rod system, the presented techniques have the potential to improve the performance of both circular and hyperbolic rod geometry QMS sensors.

Gershman, D. J.↗

Ion-retarding lens improves the abundance sensitivity of tandem mass spectrometers

Ion-retarding lens which increases the abundance sensitivity of tandem magnetic-analyzer mass spectrometers measures isotopes of low abundance in mass positions adjacent to isotopes of high abundance. The lens increases the abundance sensitivity for isotopes lying farther from high abundance isotopes than the energy cutoff of the lens.

Kaiser, K. A.↗

Comparing the Performance of Hyperbolic and Circular Rod Quadrupole Mass Spectrometers with Applied Higher Order Auxiliary Excitation

This work applies higher order auxiliary excitation techniques to two types of quadrupole mass spectrometers (QMSs): commercial systems and spaceborne instruments. The operational settings of a circular rod geometry commercial system and an engineering test-bed for a hyperbolic rod geometry spaceborne instrument were matched, with the relative performance of each sensor characterized with and without applied excitation using isotopic measurements of Kr+. Each instrument was operated at the limit of the test electronics to determine the effect of auxiliary excitation on extending instrument capabilities. For the circular rod sensor, with applied excitation, a doubling of the mass resolution at 1% of peak transmission resulted from the elimination of the low-mass side peak tail typical of such rod geometries. The mass peak stability and ion rejection efficiency were also increased by factors of 2 and 10, respectively, with voltage scan lines passing through the center of stability islands formed from auxiliary excitation. Auxiliary excitation also resulted in factors of 6 and 2 in peak stability and ion rejection efficiency, respectively, for the hyperbolic rod sensor. These results not only have significant implications for the use of circular rod quadrupoles with applied excitation as a suitable replacement for traditional hyperbolic rod sensors, but also for extending the capabilities of existing hyperbolic rod QMSs for the next generation of spaceborne instruments and low-mass commercial systems.

auxiliary excitation↗

A global empirical model of thermospheric composition based on OGO-6 mass spectrometer measurements

The analysis of composition measurements made with the neutral mass spectrometer aboard the OGO-6 satellite leads to the following conclusions. The measured atomic oxygen densities are generally in good agreement with those deduced from drag. The molecular nitrogen densities in the annual and semiannual variations depart significantly from those predicted by drag models and suggest similar departures for exospheric temperatures. The helium densities generally tend to vary in an inverse manner to the nitrogen densities. These composition changes are consistent with dynamical processes associated with the global circulation in the thermosphere.

Hedin, A. E.↗

Characteristics and performance of several mass spectrometer residual gas analyzers

The operation and properties of various mass-spectrometer residual gas analyzers for use in vacuum measurements were analyzed in terms of efficiencies of ion extraction, ion separation and transmission, and ion collection. Types of instruments studied were magnetic sector, omegatron, quadrupole, and monopole. Experimental results presented include absolute sensitivity to argon, relative sensitivity to 10 gases, and cracking patterns for these gases. It is shown that the properties are strongly dependent on instrument range, resolution, and the particular voltages, currents, or field intensities used to control the instrument.

Hultzman, W. W.↗

Evidence for enhanced dynamic flow in ionospheric holes from the Pioneer Venus Orbiter Neutral Mass Spectrometer

Ion mode measurements made by the Pioneer Venus Orbiter Neutral Mass Spectrometer (ONMS) for two ionospheric holes on orbit numbers 530 and 531 were used to find evidence for enhanced dynamic flow in ionospheric holes. The analysis of the spin modulation has provided measurements of one component of the ion drift in the hole regions. It was found that, inside the holes, the He(+)/O(+) ratio is enhanced relative to that occurring outside the holes. The in drift direction in the ecliptic plane for the hole regions was found to be consistent with downward ion flow (i.e., toward the planet) and, for one orbit examined without a hole, with upward ion flow at the approach of ionopause. The ONMS measurements in the hole and near the ionopause suggest that both areas are regions of enhanced dynamic flow.

Kasprzak, W. T.↗

The Gas Chromatograph Mass Spectrometer for the Huygens Probe

Titan is unique in the solar system, the only moon that has a dense atmosphere. The major constituents of the atmosphere, nitrogen and methane, are continuously broken apart by a combination of solar UV, impinging electrons from Saturn s magnetosphere, and a steady flux of cosmic rays. The resulting molecular fragments recombine and form a variety of new species, many of which were detected for the first time by Voyager1 . The ubiquitous, surface- hiding aerosol blanket manifests the existence of still more complex compounds. In addition to hydrocarbons and nitriles, the atmosphere is known to contain CO, CO2 and externally delivered H2O. The Gas Chromatograph Mass Spectrometer (GCMS) on the Huygens Probe will measure the chemical composition of the atmosphere of Titan from 170 Km altitude (approximately 1hPa) to the surface (approximately 1500hPa) and determine the isotope ratios of the major constituents. The GCMS will also analyze gas samples from the Aerosol Collector Pyrolyser (ACP) and may be able to obtain compositional information of several surface materials. The GCMS consists of a quadrupole mass spectrometer (QP) with a secondary electron multiplier ion detector, a three-column gas chromatograph (GC) and an elaborate gas sampling system. The gas sampling system will provide atmospheric samples to the QP for nearly continuous analysis during the Probe descent and batch samples at several altitudes for GC analysis. It also contains a chemical scrubber for noble gas analysis and an enrichment cell for trace constituent enhancement. In addition to the sampling of the atmosphere periodic gas samples, derived from the pyrolysis of aerosols, will be transferred from the ACP to the GCMS for direct QP and full GCMS analysis. The QP can analyze molecular masses from 2 to 141Dalton. The nominal detection threshold is at a mixing ratio of 10E-8. Data rate is 885 bits/sec. The mass of the instrument is 17.3 kg and the energy required for operation during the descent is 110 Watt-hours.

Niemann, H. B.↗