Search NASA⌕ Search

SEARCH · Search NASA

Results for “Materials Test Module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Tensile and Microstructure Characterization of SNS Target Swirl Bubblers Fabricated by Additive Manufacturing

During operation the mercury facing surfaces of the Spallation Neutron Source target vessel are damaged by cavitation-induced erosion. One option to decrease the erosion damage to the SNS target vessel surfaces is to decrease the intensity of the pressure waves using small bubble mitigation. Injection of small diameter helium bubbles into mercury has been shown in decrease the intensity of proton-induced pressure waves and mitigate erosion damage to mercury/container interface surfaces. Several bubbler designs have been evaluated for implementation in the SNS target. One promising bubbler design is called a swirl bubbler, which is capable of producing a high density of very small diameter helium bubbles in flowing mercury. Due to the complexity of the swirl bubbler design and the geometric restrictions of conventional machining processes, additive manufacturing was considered for fabrication. But there was uncertainty with the mechanical properties of bubblers fabricated with additive manufacturing. A series of experiments were designed to characterize the tensile properties and microstructure of swirl bubblers fabricated using selective laser melting (SLM), both before and after consolidation via hot isostatic pressing (HIPing). This report summarizes the tensile and microstructural characterization of HIPed and non-HIPed swirl bubblers produced via the SLM process. The results show that the as-fabricated material contained appreciable porosity, lack-of-fusion defects, and inconsistent tensile properties with essentially zero ductility. But after a HIPing treatment the microstructure became fully consolidated, and the tensile properties surpassed the requirements specified in the material standard for steel-mill produced 316L plate material used to fabricate the SNS target vessel. While further testing is recommended to evaluate the material’s susceptibility to fatigue fracture, these results indicate 316L bubbler assemblies produced SLM and HIPed are promising candidates for implementation in a future SNS target module.

36 MATERIALS SCIENCE↗

Innovative Application of Maintenance-Free Phase-Change Thermal Energy Storage for Dish-Engine Solar Power Generation

This final report summarizes the final results of the Phase II Innovative Application of Maintenance-Free Phase-Change Thermal Energy Storage for Dish-Engine Solar Power Generation project being performed by Infinia Corporation for the U.S. Department of Energy under contract DE-FC36-08GO18157 during the project period of September 1, 2009 - August 30, 2012. The primary objective of this project is to demonstrate the practicality of integrating thermal energy storage (TES) modules, using a suitable thermal salt phase-change material (PCM) as its medium, with a dish/Stirling engine; enabling the system to operate during cloud transients and to provide dispatchable power for 4 to 6 hours after sunset. A laboratory prototype designed to provide 3 kW-h of net electrical output was constructed and tested at Infinia's Ogden Headquarters. In the course of the testing, it was determined that the system's heat pipe network - used to transfer incoming heat from the solar receiver to both the Stirling generator heater head and to the phase change salt - did not perform to expectations. The heat pipes had limited capacity to deliver sufficient heat energy to the generator and salt mass while in a charging mode, which was highly dependent on the orientation of the device (vertical versus horizontal). In addition, the TES system was only able to extract about 30 to 40% of the expected amount of energy from the phase change salt once it was fully molten. However, the use of heat pipes to transfer heat energy to and from a thermal energy storage medium is a key technical innovation, and the project team feels that the limitations of the current device could be greatly improved with further development. A detailed study of manufacturing costs using the prototype TES module as a basis indicates that meeting DOE LCOE goals with this hardware requires significant efforts. Improvement can be made by implementing aggressive cost-down initiatives in design and materials, improving system performance by boosting efficiencies, and by refining cost estimates with vendor quotes in lieu of mass-based approaches. Although the prototype did not fully demonstrate performance and realize projected cost targets, the project team believes that these challenges can be overcome. The test data showed that the performance can be significantly improved by refining the heat pipe designs. However, the project objective for phase 3 is to design and test on sun the field ready systems, the project team feels that is necessary to further refine the prototype heat pipe design in the current prototype TES system before move on to field test units, Phase 3 continuation will not be pursued.

14 SOLAR ENERGY↗

Development of a Green Parabolic Trough Collector

This report describes in detail a research project that assesses the potential of a parabolic trough solar collector with a lumber construction to meet ambitious performance, cost, and durability goals. Instead of exploring lumber as a general question for solar collectors, the project focuses on the design optimization, laboratory testing, outdoor testing, and economic modeling of a particular scale of parabolic trough, namely, the 6m aperture and 12m long module that has become the standard in the utility-scale power plant market. As will be appreciated in the report, it is also a scale that matches well the capabilities of lumber as a structural material and the commonly available cross sections. The design and its analysis extend far beyond traditional considerations for wooden structures in the built environment, and includes a computationally efficient coupled structural-optical simulation and the empirical characterization of joint stiffness at small deformations. Laboratory testing is used to characterize cyclic joint behavior, accelerated weathering, and to validate the simulation used as the basis for building a full-scale prototype. The construction and outdoor testing of this prototype is described. A total installed cost model of the collector is presented and the impact of the cost is seen in the context of a full plant techno-economic model. The results of this model in combination with the experience with the first prototype suggest that with improvements to the design and assembly process, this collector type has the potential to lower the levelized cost of heat for industrial solar steam plants used for process heating or cogeneration.

14 SOLAR ENERGY↗

Standardized verification of the C YCLUS fuel cycle simulator

Many nuclear fuel cycle simulators can analyze transitions from once-through to advanced nuclear fuel cycles. Verification studies compare various fuel cycle analysis tools to test agreement and identify sources of difference. A recent verification study, Feng et al. (2016) established transition scenario test case specifications and accordingly evaluated national laboratory nuclear fuel cycle simulators, DYMOND, VISION, ORION, and MARKAL. This work verifies the performance of C YCLUS , the agent-based, open-source fuel cycle simulator, using the test case specifications in Feng et. al. We report, C YCLUS demonstrates agreement with the results from the previous verification study. Minor differences reflect intentional, detailed material tracking in the C YCAMORE reactor module. These results extend the example results in Feng et al. to further enable future verification of additional nuclear fuel cycle simulation tools.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Research Opportunities in Reliability of Photovoltaic Modules (Presentation)

The motivation for an increased scope and a more proactive effort in reliability research of photovoltaic modules and systems includes reducing the levelized cost of energy and gaining better confidence in the energy and financial payback for photovoltaic systems. This increased reliability and confidence will lead to greater penetration of photovoltaics in the energy portfolio and greateremployment in photovoltaics and related industries. Present research needs include the fundamental degradation mechanisms of polymers, connectors and other module components, mapping of failure mechanisms observed in the field to those in accelerated lifetime tests, determining the acceleration factors, and improving standards for modules such that tests can appropriately be assigned to evaluatetheir long term durability. Specific mechanisms discussed are corrosion in module components, metastability in thin-film active layers, delamination and loss of elastic properties in module polymeric materials, and inverter failure. Presently, there is hiring of reliability scientists and engineers at many levels of the value chain for photovoltaics.

14 SOLAR ENERGY↗

Investigation of Corrosion of 304 Stainless, Inconel 625, and Haynes 230 in a Chloride-Salt-Based Thermal Storage Medium

One of the critical challenges for latent heat thermal energy storage systems in concentrating solar power applications is corrosion of metallic alloys as containment and heat transfer fluid tube materials in corrosive salts at high temperatures. In this study, the effects of MgCl 2 on the corrosion of stainless steel 304, Inconel 625, and Haynes 230 alloys were investigated through embedded metal samples in the graphite foam/MgCl 2 storage medium. Four experimental testing modules were fabricated, and experimental tests were conducted under controlled environment by heating the testing modules to and keeping them at 750 °C for 100, 200, 500, and 1000 h. The estimated corrosion rates based on the weight losses for stainless steel 304, Inconel 625, and Haynes 230 were 94, 9, and 8 μm/year, respectively. The fitted equations for the loss of the thickness as functions of the exposure time show that the corrosion rates decrease with the exposure time. Additionally, the results on the corrosion zones or depths and chromium segregation ranges of the experimental samples are also presented.

36 MATERIALS SCIENCE↗

Development of low mass optical readout for high data bandwidth systems.

At Argonne National Laboratory the High Energy Physics and Center for Nanoscale Materials Divisions are working on a project to develop a new generation of detector readout using high speed data transfer optical devices that can be implemented in particle physics or for long distances. Free-space communications devices offer the potential for reductions in mass, power, and cost of data paths for on-board trigger and readout of tracking detectors. The project involves three areas of study: light modulation, the design and construction of MEMS optical devices, and the control systems for maintaining precise laser light positioning. We demonstrate an optical link in air over one meter and with low error rate at 1 Gb/s. We demonstrate steering of an optical beam over a meter with a precision of 5 micrometers utilizing a MEMS mirror and reflected light in the feedback loop. For early testing, light modulation tests with a fiber link using Li-Niobate modulators and a data generation and error checking chip are done at 1 Gb/s. Many companies and universities are developing modulators which will be incorporated into CMOS chips. We are doing radiation hardness studies for one of the materials involved. Laser light will need to be steered on to and kept centered on the detector in the presence of thermal or mechanical motion, etc. This steering will be controlled by MEMS mirrors. Polycrystalline and crystalline silicon based mirror designs are being studied. We review the current status of the project and outline plans for the future development of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parameter extraction approaches for compact modeling of thermoelectric modules

Thermoelectric (TE) cooling has experienced rapid advancements with the foundational understanding of TE materials. TE modules, compact and lightweight devices, have become the prevalent approach for implementing TE technologies. Accurately quantifying TE physical parameters (Seebeck coefficient α, thermal conductivity κ, and thermal resistance ρ) is challenging due to the dynamic temperature changes in operation. Furthermore, extracting lumped property parameters is crucial for designing energy systems using TE modules. Existing research has several limitations, such as lack of comparative analysis between prevalent formulae, reliance on potentially inaccurate vendor-supplied data, disregard for fundamental assumptions, and absence of empirical measurements. Further, this study addresses these gaps by conducting TE material characterization, comparing three existing formulae using vendor datasheets, designing a laboratory test facility for model validation and refinement, and outlining a structured data extraction procedure. The study's novelty lies in multiple key contributions: (1) a detailed comparative analysis of existing formulae for extracting TE property parameter; (2) executing experimental work in a laboratory setting to validate the model and elucidate its limitations; (3) highlighting potential risks; (4) clarifying possible assumptions from both material and engineering perspectives; and (5) considering temperature differential impacts. This comprehensive approach addresses the current research gaps and provides valuable insights into the design and application of TE modules in various energy systems.

36 MATERIALS SCIENCE↗

Measurement of third-order elastic constants using thermal modulation of ultrasonic waves

Third-order elastic constants (TOEC) play an important role in nonlinear material characterization, but measurements of TOEC are laborious with large error margins. This Letter presents the equations of wave velocity changes caused by homogeneous temperature variation and uniaxial stress in isotropic media and the expression of TOEC in terms of thermally induced velocity change and thermal strain. TOEC of an aluminum sample were experimentally determined by measuring ultrasonic wave velocity changes in the uniaxial loading test and the thermal modulation test. Experimental results showed good agreement between the two test methods. Owing to the simple test setup and high measurement sensitivity, the thermal modulation test is a potential experimental method to determine TOEC and absolute acoustic nonlinearity parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase I Trial of Pelvic Nodal Dose Escalation With Hypofractionated IMRT for High-Risk Prostate Cancer

Purpose: Toxicity concerns have limited pelvic nodal prescriptions to doses that may be suboptimal for controlling microscopic disease. In a prospective trial, we tested whether image-guided intensity-modulated radiation therapy (IMRT) can safely deliver escalated nodal doses while treating the prostate with hypofractionated radiotherapy in 5 Vulgar-Fraction-One-Half weeks. Methods and Materials: Pelvic nodal and prostatic image-guided IMRT was delivered to 53 National Comprehensive Cancer Network (NCCN) high-risk patients to a nodal dose of 56 Gy in 2-Gy fractions with concomitant treatment of the prostate to 70 Gy in 28 fractions of 2.5 Gy, and 50 of 53 patients received androgen deprivation for a median duration of 12 months. Results: The median follow-up time was 25.4 months (range, 4.2-57.2). No early Grade 3 Radiation Therapy Oncology Group or Common Terminology Criteria for Adverse Events v.3.0 genitourinary (GU) or gastrointestinal (GI) toxicities were seen. The cumulative actuarial incidence of Grade 2 early GU toxicity (primarily alpha blocker initiation) was 38%. The rate was 32% for Grade 2 early GI toxicity. None of the dose-volume descriptors correlated with GU toxicity, and only the volume of bowel receiving {>=}30 Gy correlated with early GI toxicity (p = 0.029). Maximum late Grades 1, 2, and 3 GU toxicities were seen in 30%, 25%, and 2% of patients, respectively. Maximum late Grades 1 and 2 GI toxicities were seen in 30% and 8% (rectal bleeding requiring cautery) of patients, respectively. The estimated 3-year biochemical control (nadir + 2) was 81.2 {+-} 6.6%. No patient manifested pelvic nodal failure, whereas 2 experienced paraaortic nodal failure outside the field. The six other clinical failures were distant only. Conclusions: Pelvic IMRT nodal dose escalation to 56 Gy was delivered concurrently with 70 Gy of hypofractionated prostate radiotherapy in a convenient, resource-efficient, and well-tolerated 28-fraction schedule. Pelvic nodal dose escalation may be an option in any future exploration of potential benefits of pelvic radiation therapy in high-risk prostate cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-D-17A-04: Magnetically Focused Proton Irradiation of Small Volume Targets

Purpose: To explore the advantages of magnetic focusing for small volume proton irradiations and the potential clinical benefits for radiosurgery targets. The primary goal is to create narrow elongated proton beams of elliptical cross section with superior dose delivery characteristics compared to current delivery modalities (eg, collimated beams). In addition, more general beam shapes are also under investigation. Methods: Two prototype magnets consisting of 24 segments of samarium-cobalt (Sm2Co17) permanent magnetic material adhered into hollow cylinders were manufactured for testing. A single focusing magnet was placed on a positioning track on our Gantry 1 treatment table and 15 mm diameter proton beams with energies and modulation relevant to clinical radiosurgery applications (127 to 186 MeV, and 0 to 30 mm modulation) were delivered to a terminal water tank. Beam dose distributions were measured using a PTW diode detector and Gafchromic EBT2 film. Longitudinal and transverse dose profiles were analyzed and compared to data from Monte Carlo simulations analogous to the experimental setup. Results: The narrow elongated focused beam spots showed high elliptical symmetry indicating high magnet quality. In addition, when compared to unfocused beams, peak-to-entrance depth dose ratios were 11 to 14% larger (depending on presence or extent of modulation), and minor axis penumbras were 11 to 20% smaller (again depending on modulation) for focused beams. These results suggest that the use of rare earth magnet assemblies is practical and could improve dose-sparing of normal tissue and organs at risk while delivering enhanced dose to small proton radiosurgery targets. Conclusion: Quadrapole rare earth magnetic assemblies are a promising and inexpensive method to counteract particle out scatter that tends to degrade the peak to entrance performance of small field proton beams. Knowledge gained from current experiments will inform the design of a prototype treatment nozzle that incorporates similar focusing magnets. This project was sponsored in part by funding from the Department of Defense (DOD# W81XWH-BAA-10-1)

60 APPLIED LIFE SCIENCES↗

Upgraded cavities for the CEBAF cryomodule rework program

The CEBAF cryomodule rework program has been a successful tool to recover and maintain the energy reach of the original baseline 6 GeV accelerator. The weakest original modules with eight five-cell cavities assembled in four ?pairs?, with a specification when new of 20 MV per cryomodule (5 MV/m), are disassembled, re-cleaned with modern techniques and re-qualified to at least 50 MV (12.5 MV/m), (leading to the acronym ?C50?). The cost per recovered MV is much less than building new modules. However over time the stock of weak modules is being used up and the voltage gain per rework cycle is diminishing. In an attempt to increase the gain per cycle it is proposed to rework the cavities by replacing the original accelerating cells with new ones of an improved shape and better material. The original CEBAF HOM and FPC end groups are retained. The goal is to achieve up to 75 MV (18.75 MV/m) for the reworked module (?C75?). We report on the fabrication experience and test results of the first trial pair, containing two such reworked cavities.

Rimmer, Robert↗

PEM Electrolyzer Incorporating an Advanced Low-Cost Membrane

Electrolysis of water, particularly in conjunction with renewable energy sources, is potentially a cost-effective and environmentally friendly method of producing hydrogen at dispersed forecourt sites, such as automotive fueling stations. However, state-of-the-art proton-exchange-membrane (PEM) electrolyzer systems have not been economically competitive for forecourt hydrogen production due to their high capital and operating costs, particularly the cost of the electricity used by the electrolyzer stack. The forecourt hydrogen application requires an electrolyzer that produces 1500 kg/day (62.5 kg/hr) hydrogen. At the present time, the markets for PEM electrolyzers are for much smaller units, typically less than 5 kg/hr. Although larger stacks have been developed they have not been commercialized. Thus, PEM electrolyzer systems are generally quite small. The primary feedstock for an electrolyzer is electricity, which could be produced by renewable sources such as wind or solar that do not produce carbon dioxide or other greenhouse gas emissions. In this project, Giner, Inc. (Giner) developed a low-cost, high-efficiency PEM electrolysis stack and system for hydrogen production at moderate pressures of 300 to 400 psig (2170 to 2860 kPa). The electrolyzer stack operates at differential pressure, with hydrogen produced at moderate pressure while oxygen is evolved at near-atmospheric pressure, reducing the cost of the water feed and oxygen handling subsystems. The project included research on catalysts and membranes to improve the efficiency of the electrolysis reaction, as well as development of advanced materials and component fabrication methods to reduce the capital cost of the electrolyzer stack and system. The project culminated in the delivery of a prototype electrolyzer module to the National Renewable Energy Laboratory for testing at the National Wind Technology Center. Electrolyzer stack efficiency of 74% LHV (87%HHV), meeting DOE 2012 targets, was demonstrated using an advanced high-strength membrane. Giner significantly reduced the capital cost of a PEM electrolyzer stack through development of low-cost components and fabrication methods, including a 60% reduction in stack cost. The estimated cost of the present stack design in large-scale production is less than $\$$350/kW. In addition, Giner demonstrated improved lifetimes of the advanced membrane and cell components that can exceed 60,000 hours of operation. An Economic analysis indicates that hydrogen, prior to delivery costs, could be produced for $\$$3.64 per gge (gasoline-gallon equivalent) at an electricity cost of $\$$0.04/kWh utilizing the lower-cost PEM electrolyzer developed in this project assuming high-volume production of large-scale systems.

08 HYDROGEN↗

Critical Research for Cost-Effective Photoelectrochemical Production of Hydrogen

The objective of this project is to develop critical technologies required for cost-effective production of hydrogen from sunlight and water using a-Si triple junction solar cell based photo-electrodes. In this project, Midwest Optoelectronics, LLC (MWOE) and its collaborating organizations utilize triple junction a-Si thin film solar cells as the core element to fabricate photoelectrochemical (PEC) cells. Triple junction a-Si/a-SiGe/a-SiGe solar cell is an ideal material for making cost-effective PEC system which uses sun light to split water and generate hydrogen. It has the following key features: 1) It has an open circuit voltage (Voc ) of ~ 2.3V and has an operating voltage around 1.6V. This is ideal for water splitting. There is no need to add a bias voltage or to inter-connect more than one solar cell. 2) It is made by depositing a-Si/a-SiGe/aSi-Ge thin films on a conducting stainless steel substrate which can serve as an electrode. When we immerse the triple junction solar cells in an electrolyte and illuminate it under sunlight, the voltage is large enough to split the water, generating oxygen at the Si solar cell side (for SS/n-i-p/sunlight structure) and hydrogen at the back, which is stainless steel side. There is no need to use a counter electrode or to make any wire connection. 3) It is being produced in large rolls of 3ft wide and up to 5000 ft long stainless steel web in a 25MW roll-to-roll production machine. Therefore it can be produced at a very low cost. After several years of research with many different kinds of material, we have developed promising transparent, conducting and corrosion resistant (TCCR) coating material; we carried out extensive research on oxygen and hydrogen generation catalysts, developed methods to make PEC electrode from production-grade a-Si solar cells; we have designed and tested various PEC module cases and carried out extensive outdoor testing; we were able to obtain a solar to hydrogen conversion efficiency (STH) about 5.7% and a running time about 480 hrs, which are very promising results; we have also completed a techno-economic analysis of our PEC system, which indicates that a projected hydrogen generation cost of $2/gge is achievable with a 50 Ton-per-day (TPD) scale under certain conditions.

08 HYDROGEN↗

Ultralight Door Design, Development and Demonstration Project (Final Scientific Report)

The project objectives associated with the Ultralight Door Project were to develop a lightweight driver's side door, 42.5% lighter than a current model year high-volume baseline door, at an incremental cost not to exceed $ \$ $ 5 per pound saved, while maintaining equivalent functionality, safety, corrosion, durability and sound transmission performance of the baseline vehicle. The project approach included the selection of a door architecture, development of a key performance target matrix and incremental cost model. Several unique door structures were developed and evaluated using computer-aided engineering (CAE) and cost modeling tools. The aluminum-intensive door structure was the only design capable of meeting both the performance and cost criteria objectives. The door module, glass, interior trim, latch and electrical subsystems were functionally integrated with the aluminum door structure, enabling additional mass reduction beyond material substitution. The lightweight door design was prototyped, integrated with baseline vehicles and tested to validate equivalent functionality and performance. The project results demonstrate a mass reduction of 15.2 kg (40%) at an incremental cost of $ \$ $2.81 per pound saved, while maintaining functionality and performance of the baseline door. The environmental benefit associated with the Ultralight Door enables a 6g CO 2 eq. per kilometer environmental benefit, for a 4-door vehicle powered by a downsized fuel injected gasoline combustion engine. The project results were presented and published in the 2018 SAE International Conference proceedings and in the Journal of Life Cycle Assessment.

36 MATERIALS SCIENCE↗

Time series anomaly detection in power electronics signals with recurrent and ConvLSTM autoencoders

The anomalies in the high voltage converter modulator (HVCM) remain a major down time for the spallation neutron source facility, that delivers the most intense neutron beam in the world for scientific materials research. In this work, we propose neural network architectures based on Recurrent AutoEncoders (RAE) to detect anomalies ahead of time in the power signals coming from the HVCM. Bi-directional gated recurrent unit, bi-directional long-short term memory (LSTM), and convolutional LSTM (ConvLSTM) are developed, trained, and tested using real experimental signals from the HVCM module. The results show a good performance of the proposed RAE models, achieving precision up to 91%, recall up to 88%, false omission rate as low as 20% (i.e. 80% of the anomalies were detected), and area under the ROC curve up to 0.9. The three RAE models provide very comparable performance, with LSTM showing slightly better performance than GRU and ConvLSTM. The RAE models are benchmarked against other anomaly detection methods, including isolation forest, support vector machine, local outlier factor, feedforward and convolutional autoencoders, and others; showing a better performance. Here, the results of this study demonstrate the promising potential of RAE in anomaly detection for real-world power systems, and for increasing the reliability of the HVCM modules in the spallation neutron source.

42 ENGINEERING↗

Parametric Study of X-ray Energy Modulation for Depth Sensitive Backscatter Imaging

The technique of X-ray backscatter imaging has been studied for its applications in both medical imaging and nondestructive testing. The geometry and dimensionality of the detector system and photon source affect acquisition time, resolution, and signal to noise ratio (SNR) but the end result is still, at most, a 2D image. This is similar to transmission radiography with the difference being that the backscatter image has the benefit of requiring only single sided access to the object. Despite these physical limitations to the dimensions of a backscatter image, Towe and Jacobs showed that it is possible to obtain depth sensitive information (the third dimension in this case) by acquiring multiple images, each at a different X-ray tube voltage. By changing the average energy of the X-ray source, the penetration depth and therefore the signal which is generated from a backscatter design changes depending on the materials present in the object of interest. In order to further investigate the capabilities of depth sensitive X-ray backscatter imaging, a parametric study has been conducted on X-ray energy and its associated backscatter signal depth for materials relevant to medical imaging and non-destructive testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗