Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Quantum data gathering

Measurement of a quantum system – the process by which an observer gathers information about it – provides a link between the quantum and classical worlds. The nature of this process is the central issue for attempts to reconcile quantum and classical descriptions of physical processes. Here, we show that the conventional paradigm of quantum measurement is directly responsible for a well-known disparity between the resources required to extract information from quantum and classical systems. We introduce a simple form of quantum data gathering, ‘‘coherent measurement’’, that eliminates this disparity and restores a pleasing symmetry between classical and quantum statistical inference. To illustrate the power of quantum data gathering, we demonstrate that coherent measurements are optimal and strictly more powerful than conventional one-at-a-time measurements for the task of discriminating quantum states, including certain entangled many-body states (e.g., matrix product states).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental estimation of one-parameter qubit gates in the presence of phase diffusion

We address estimation of one-parameter qubit gates in the presence of phase diffusion. We evaluate the ultimate quantum limits to precision, seek optimal probes and measurements, and demonstrate an optimal estimation scheme for polarization encoded optical qubits. An adaptive method to achieve optimal estimation in any working regime is also analyzed in detail and experimentally implemented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultra-high Bandwidth, Ultra-high Dynamic Range X-Ray Shock Characterization via Photonic Integrated Circuit

Nuclear weapon component assessment tests at the Z Machine rely on accurate X-ray yield measurements for model validation, design and analysis of component survivability, and source optimization. Yield measurement devices currently used do not provide the requisite certainty to enable accurate and efficient data analysis of test results, which leads to an increase in Z-shots required for evaluation, longer device development times, and higher operation costs. Additionally, current X-ray flux detectors lack high temporal resolution at the tails. Similarly, shock measurement techniques used for component assessment often lack the ability to spatially resolve wave behavior thereby limiting the ability to measure shock propagation dynamics needed to design the next generation of ND components. Here we present the development of a photonic micro-calorimeter and shock sensor consisting of meter-long waveguide spirals that are optomechanically coupled to X-ray absorbing layers to characterize yield and shock propagation at nanosecond timescales.

42 ENGINEERING↗

Reduced state feedback gain computation

Because application of conventional optimal linear regulator theory to flight controller design requires the capability of measuring and/or estimating the entire state vector, it is of interest to consider procedures for computing controls which are restricted to be linear feedback functions of a lower dimensional output vector and which take into account the presence of measurement noise and process uncertainty. Therefore, a stochastic linear model that was developed is presented which accounts for aircraft parameter and initial uncertainty, measurement noise, turbulence, pilot command and a restricted number of measurable outputs. Optimization with respect to the corresponding output feedback gains was performed for both finite and infinite time performance indices without gradient computation by using Zangwill's modification of a procedure originally proposed by Powell. Results using a seventh order process show the proposed procedures to be very effective.

Kaufman, H.↗

Some test/analysis issues for the space station structural characterization experiment

The Space Station Structural Characterization Experiment (SSSCE) 1,2 is an early space flight experiment that uses the space station as a generic structure to study the dynamic characteristics of Large Space Structures (LSS). On-orbit modal testing will be conducted to determine natural frequencies, mode shapes and damping of dominant structural modes of the space structure assembly. This experiment will utimately support the development of system identification and analytical modeling techniques for Large Space Structures. In order to ensure the success of SSSCE (in-space validation of modeling techniques for LSS), adequate measurement and instrumentation requirements have to be established during the experiment-definition study. Among the issues affecting these requirements, spatial and modal coverages of the modal test data are of particular interest. Topics such as total number of sensors, type of measurements (translation and rotation), optimal sensor locations (measurement degrees-of-freedom), selection of target modes, effects of modal superposition and truncation, separation of global and local modes, etc., are all a fundamental importance and must be investigated.

Chou, Chaur-Ming↗

Low-Flow-Rate Dry-Powder Feeder

Apparatus feeds small, precise flow of dry powder through laser beam of optical analyzer measuring patterns of light created by forward scattering (Fraunhofer diffraction) of laser beam from powder particles. From this optical measurement, statistical distribution of sizes of powder particles computed. Rates of flow optimized for measurement of particle-size distributions. Developed for analyzing particle-size distributions of solid-propellant powders. Also adapted to pharmaceutical industry, in manufacture of metal powder, and in other applications where particle-size distributions of materials used to control rates of chemical reactions and/or physical characteristics of processes.

Ramsey, Keith E.↗

Optimization of FRAM precision for isotopic measurements on large samples of low-burnup PuO2

The gamma ray spectrum of plutonium contains measurable gamma rays ranging in energy from 60 keV to above 1 MeV. The FRAM gamma ray isotopic analysis code can analyze data from all types of HPGe detectors in this energy range typically using planar detectors in the energy range 60-210 keV or 120-451 keV and using coaxial detectors in the energy ranges 120-451 keV or 200-1001 keV. The statistical measurement precision depends upon the detector/energy range combination as well as the characteristics of the sample and any addition filters. In this paper we carry out the optimization of measurement precision for the important case of a multi-kg sample of low bumup PuO{sub 2} contained in a DOE 3013 Standard-compatible long-teml storage container.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

INVESTIGATION ON THE OSCILLATING GAS FLOW ALONG AN INERTANCE TUBE BY EXPERIMENTAL AND CFD METHODS

To investigate the oscillating gas flow along an inertance tube used in pulse tube coolers, a CFD model is set up for FLUENT and an experimental measuring cell is designed and optimized by CFD results. Some characteristics of oscillating flow are demonstrated and discussed. Then, the flow status along an inertance tube is measured by the optimized measuring cell. The experimental results validate the simulating results.

42 ENGINEERING↗

Quantitative evaluation of statistical errors in small-angle X-ray scattering measurements

A new model is proposed for the measurement errors incurred in typical small-angle X-ray scattering (SAXS) experiments, which takes into account the setup geometry and physics of the measurement process. The model accurately captures the experimentally determined errors from a large range of synchrotron and in-house anode-based measurements. Its most general formulation gives for the variance of the buffer-subtracted SAXS intensity σ 2 ( q ) = [ I ( q ) + const.]/( kq ), where I ( q ) is the scattering intensity as a function of the momentum transfer q ; k and const. are fitting parameters that are characteristic of the experimental setup. The model gives a concrete procedure for calculating realistic measurement errors for simulated SAXS profiles. In addition, the results provide guidelines for optimizing SAXS measurements, which are in line with established procedures for SAXS experiments, and enable a quantitative evaluation of measurement errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-TeP3-11: Radiobiological-Cum-Dosimetric Quality Assurance of Complex Radiotherapy Plans

Purpose: Dosimetric gamma-analysis used for QA of complex radiotherapy plans tests the dosimetric equivalence of a delivered plan with the treatment planning system (TPS) optimized plan. It does not examine whether a dosimetric difference results in any radiobiological difference. This study introduces a method to test the radiobiological and dosimetric equivalence between a delivered and the TPS optimized plan. Methods: Six head and neck and seven lung cancer VMAT or IMRT plans optimized for patient treatment were calculated and delivered to an ArcCheck phantom. ArcCheck measured dose distributions were compared with the TPS calculated dose distributions using a 2-D gamma-analysis. Dose volume histograms (DVHs) for various patient structures were obtained by using measured data in 3DVH software and compared against the TPS calculated DVHs using 3-D gamma analysis. DVH data were used in the Poisson model to calculate tumor control probability (TCP) for the treatment targets and in the sigmoid dose response model to calculate normal tissue complication probability (NTCP) for the normal structures. Results: Two-D and three-D gamma passing rates among six H&N patient plans differed by 0 to 2.7% and among seven lung plans by 0.1 to 4.5%. Average ± SD TCPs based on measurement and TPS were 0.665±0.018 and 0.674±0.044 for H&N, and 0.791±0.027 and 0.733±0.031 for lung plans, respectively. Differences in NTCPs were usually negligible. The differences in dosimetric results, TCPs and NTCPs were insignificant. Conclusion: The 2-D and 3-D gamma-analysis based agreement between measured and planned dose distributions may indicate their dosimetric equivalence. Small and insignificant differences in TCPs and NTCPs based on measured and planned dose distributions indicate the radiobiological equivalence between the measured and optimized plans. However, patient plans showing larger differences between 2-D and 3-D gamma-analysis can help us make a more definite conclusion through our ongoing research with a larger number of patients.

60 APPLIED LIFE SCIENCES↗

Computation of output feedback gains for linear stochastic systems using the Zangnill-Powell Method

Because conventional optimal linear regulator theory results in a controller which requires the capability of measuring and/or estimating the entire state vector, it is of interest to consider procedures for computing controls which are restricted to be linear feedback functions of a lower dimensional output vector and which take into account the presence of measurement noise and process uncertainty. To this effect a stochastic linear model has been developed that accounts for process parameter and initial uncertainty, measurement noise, and a restricted number of measurable outputs. Optimization with respect to the corresponding output feedback gains was then performed for both finite and infinite time performance indices without gradient computation by using Zangwill's modification of a procedure originally proposed by Powell. Results using a seventh order process show the proposed procedures to be very effective.

Kaufman, H.↗

Computation of output feedback gains for linear stochastic systems using the Zangwill-Powell method

Because conventional optimal linear regulator theory results in a controller which requires the capability of measuring and/or estimating the entire state vector, it is of interest to consider procedures for computing controls which are restricted to be linear feedback functions of a lower dimensional output vector and which take into account the presence of measurement noise and process uncertainty. To this effect a stochastic linear model has been developed that accounts for process parameter and initial uncertainty, measurement noise, and a restricted number of measurable outputs. Optimization with respect to the corresponding output feedback gains was then performed for both finite and infinite time performance indices without gradient computation by using Zangwill's modification of a procedure originally proposed by Powell.

Kaufman, H.↗

Bridge Testing With Ground-Based Interferometric Radar: Experimental Results

The research of innovative non-contact techniques aimed at the vibration measurement of civil engineering structures (also for damage detection and structural health monitoring) is continuously directed to the optimization of measures and methods. Ground-Based Radar Interferometry (GBRI) represents the more recent technique available for static and dynamic control of structures and ground movements.Dynamic testing of bridges and buildings in operational conditions are currently performed: (a) to assess the conformity of the structure to the project design at the end of construction; (b) to identify the modal parameters (i.e. natural frequencies, mode shapes and damping ratios) and to check the variation of any modal parameters over the years; (c) to evaluate the amplitude of the structural response to special load conditions (i.e. strong winds, earthquakes, heavy railway or roadway loads). If such tests are carried out by using a non-contact technique (like GBRI), the classical issues of contact sensors (like accelerometers) are easily overtaken.This paper presents and discusses the results of various tests carried out on full-scale bridges by using a Stepped Frequency-Continuous Wave radar system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Housing Stock Characterization Study: An Innovative Approach to Measuring Retrofit Impact

A residential energy efficiency retrofit loan program depends on a self-sustaining finance option and optimized retrofit measures that recoup their unsubsidized costs through energy bill savings alone within the useful life of the retrofit. A first step in evaluating retrofit options is to measure and verify their energy savings. This report evaluates Orlando Utilities Commission (OUC)residential energy-efficiency demand side management (DSM) programs to assess their relative energy and economic performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Housing Stock Characterization Study: An Innovative Approach to Measuring Retrofit Impact

A residential energy efficiency retrofit loan program depends on a self-sustaining finance option and optimized retrofit measures that recoup their unsubsidized costs through energy bill savings alone within the useful life of the retrofit. A first step in evaluating retrofit options is to measure and verify their energy savings. This report evaluates Orlando Utilities Commission (OUC) residential energy-efficiency demand side management (DSM) programs to assess their relative energy and economic performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

THE COSMIC INFRARED BACKGROUND EXPERIMENT (CIBER): A SOUNDING ROCKET PAYLOAD TO STUDY THE NEAR INFRARED EXTRAGALACTIC BACKGROUND LIGHT

The Cosmic Infrared Background Experiment (CIBER) is a suite of four instruments designed to study the near infrared (IR) background light from above the Earth's atmosphere. The instrument package comprises two imaging telescopes designed to characterize spatial anisotropy in the extragalactic IR background caused by cosmological structure during the epoch of reionization, a low resolution spectrometer to measure the absolute spectrum of the extragalactic IR background, and a narrow band spectrometer optimized to measure the absolute brightness of the zodiacal light foreground. In this paper we describe the design and characterization of the CIBER payload. The detailed mechanical, cryogenic, and electrical design of the system are presented, including all system components common to the four instruments. We present the methods and equipment used to characterize the instruments before and after flight, and give a detailed description of CIBER's flight profile and configurations. CIBER is designed to be recoverable and has flown four times, with modifications to the payload having been informed by analysis of the first flight data. All four instruments performed to specifications during the subsequent flights, and the scientific data from these flights are currently being analyzed.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-201: Acceleration of Dose Optimization Process Using Dual-Loop Optimization Technique for Spot Scanning Proton Therapy

Purpose: The purpose was to demonstrate a developed acceleration technique of dose optimization and to investigate its applicability to the optimization process in a treatment planning system (TPS) for proton therapy. Methods: In the developed technique, the dose matrix is divided into two parts, main and halo, based on beam sizes. The boundary of the two parts is varied depending on the beam energy and water equivalent depth by utilizing the beam size as a singular threshold parameter. The optimization is executed with two levels of iterations. In the inner loop, doses from the main part are updated, whereas doses from the halo part remain constant. In the outer loop, the doses from the halo part are recalculated. We implemented this technique to the optimization process in the TPS and investigated the dependence on the target volume of the speedup effect and applicability to the worst-case optimization (WCO) in benchmarks. Results: We created irradiation plans for various cubic targets and measured the optimization time varying the target volume. The speedup effect was improved as the target volume increased, and the calculation speed increased by a factor of six for a 1000 cm3 target. An IMPT plan for the RTOG benchmark phantom was created in consideration of ±3.5% range uncertainties using the WCO. Beams were irradiated at 0, 45, and 315 degrees. The target’s prescribed dose and OAR’s Dmax were set to 3 Gy and 1.5 Gy, respectively. Using the developed technique, the calculation speed increased by a factor of 1.5. Meanwhile, no significant difference in the calculated DVHs was found before and after incorporating the technique into the WCO. Conclusion: The developed technique could be adapted to the TPS’s optimization. The technique was effective particularly for large target cases.

60 APPLIED LIFE SCIENCES↗

Evaluation of Missed Energy Saving Opportunity Based on Illinois Home Performance Program Field Data: Homeowner Selected Upgrades vs. Cost-Optimized Solutions; Chicago, Illinois (Fact Sheet)

Expanding on previous research by PARR, this study compares measure packages installed during 800 Illinois Home Performance with ENERGY STAR (IHP) residential retrofits to those recommended as cost-optimal by Building Energy Optimization (BEopt) modeling software. In previous research, cost-optimal measure packages were identified for fifteen Chicagoland single family housing archetypes, called housing groups. In the present study, 800 IHP homes are first matched to one of these fifteen housing groups, and then the average measures being installed in each housing group are modeled using BEopt to estimate energy savings. For most housing groups, the differences between recommended and installed measure packages is substantial. By comparing actual IHP retrofit measures to BEopt-recommended cost-optimal measures, missed savings opportunities are identified in some housing groups; also, valuable information is obtained regarding housing groups where IHP achieves greater savings than BEopt-modeled, cost-optimal recommendations. Additionally, a measure-level sensitivity analysis conducted for one housing group reveals which measures may be contributing the most to gas and electric savings. Overall, the study finds not only that for some housing groups, the average IHP retrofit results in more energy savings than would result from cost-optimal, BEopt-recommended measure packages, but also that linking home categorization to standardized retrofit measure packages provides an opportunity to streamline the process for single family home energy retrofits and maximize both energy savings and cost-effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗