Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

An improved method of measuring tropospheric NO2, NO3, HO2, and RO2 by Matrix Isolation and Electronic Spin Resonance (MIESR)

The MIESR method consists of two steps (1) collection of the radicals present in the ambient air at 77K in a polycrystalline D2O matrix and (2) identification and quantification of the different radicals in the laboratory by Electron Spin Resonance spectroscopy. In step (1), the sampling efficiency for sampling NO2 and RO2 was determined to be greater than or equal to 95 percent, with a measured accuracy of plus or minus 5 percent. In step (2), after collection, the samples are maintained at 77 K and spectra are recorded in the laboratory using a standard 9.5 GHz ESR system (Varian E-line). About 50 individual scans of each spectrum are recorded and digitally averaged in order to improve the signal-to-noise ratio. The ESR-spectra are analyzed with a recently developed numerical procedure which was demonstrated to allow speciation of NO2, NO3, HO2, CH3C(O)O2, and the sum of the alkylperoxy radicals. The detection limit is 5ppt for HO2, RO2, and NO2 and 3ppt for NO3 due to its narrower ESR-linewidth.

Source record↗

The Doubly Labeled Water Method for Measuring Human Energy Expenditure: Adaptations for Spaceflight

It is essential to determine human energy requirements in space, and the doubly labeled water method has been identified as the most appropriate means of indirect calorimetry to meet this need. The method employs naturally occurring, stable isotopes of hydrogen (H-2, deuterium) and oxygen (O-18) which, after dosing, mix with body water. The deuterium is lost from the body as water while the O-18 is eliminated as both water and CO2. The difference between the two isotope elimination rates is therefore a measure of CO2 production and hence energy expenditure. Spaceflight will present a unique challenge to the application of the doubly labeled water method. Specifically, interpretation of doubly labeled water results assumes that the natural abundance or 'background' levels of the isotopes remain constant during the measurement interval. To address this issue, an equilibration model will be developed in an ongoing ground-based study. As energy requirements of women matched to counterparts in the Astronauts Corps are being determined by doubly labeled water, the baseline isotope concentration will be changed by consumption of 'simulated Shuttle water' which is artificially enriched. One group of subjects will be equilibrated on simulated Shuttle water prior to energy determinations by doubly labeled water while the others will consume simulated Shuttle water after dosing. This process will allow us to derive a prediction equation to mathematically model the effect of changing background isotope concentrations.

Schulz, Leslie O.↗

Active microwave water equivalence

Measurements of water equivalence using an active FM-CW microwave system were conducted over the past three years at various sites in Colorado, Wyoming, and California. The measurement method is described. Measurements of water equivalence and stratigraphy are compared with ground truth. A comparison of microwave, federal sampler, and snow pillow measurements at three sites in Colorado is described.

Boyne, H. S.↗

Two-measured variable method for wall interference assessment/correction

An iterative method for wall interference assessment and/or correction is presented for transonic flow conditions in wind tunnels equipped with two component velocity measurements on a single interface. The iterative method does not require modeling of the test article and tunnel wall boundary conditions. Analytical proof for the convergence and stability of the iterative method is shown in the subsonic flow regime. The numerical solutions are given for both 2-D and axisymmetrical cases at transonic speeds with the application of global Mach number correction.

Lo, C. F.↗

The measurement system of pulse modulated carrier frequency stability and timing jitter

The definition of pulse modulated carrier frequency stability and timing jitter as well as the configuration and synchronous acquisition measurement method of its measurement system. Frequency stability of the pulse modulated carrier is measured with a discrimination technique. The pulse modulated carrier under testing is mixed with a reference frequency synthesizer. A delay line is used to convert the frequency fluctuation mixed IF signal to the voltage fluctuation. The system has the capability to make the phase noise measurement of two port devices on a pulsed carrier using a phase bridge. The noise voltage mentioned above is applied to the data acquisition and processing unit by PC to realize stability measurement. The data acquisition is in the form of pulse synchronization so that the measurement system accuracy is increased. The pulse width is more than 0.3 microseconds. The phase fluctuation variance, sigma, is less than 0.017. The time interval measuring system with high resolution is used to make interpulse timing and pulse width jitters automatic measurement. The pulse width is less than 0.2 ns. The resolution is 0.1 ns. The system is successfully applied to radar measurement.

Li Cheng-Fu↗

Pressure and temperature measurement in supercharger investigations

With the further development of the supercharger, requirements with regard to measuring accuracy increase while at the same time the conditions under which the measurements must be carried out become more difficult. The present paper is a contribution toward the improvement and refinement of the measuring methods. For pressure measurements some suggestions are made with regard to design and location of the measuring stations. The question of temperature measurement in rapid air flow is discussed, new instruments for the direct measurement of the temperature in the rapid airstream are described and the results obtained with the various instruments presented.

Franz, A↗

A new method for measuring refractory corrosion of ceramics in glass

Abstract Nuclear waste glass vitrification furnaces are lined with refractory ceramic blocks to contain the molten glass. The refractory liner is susceptible to corrosion and has a finite service lifetime. For this reason, predicting the refractory corrosion in contact with molten glass is integral to estimating melter service lifetime. Standardized laboratory tests varying time and temperature are commonly performed to estimate refractory material loss as a function of glass composition. These data are time and resource‐intensive to collect and are susceptible to considerable measurement error. In order to accelerate glass formulation and design for nuclear waste vitrification, methods are needed to increase laboratory‐scale throughput while maintaining data quality. In this work, a method to remove the residual glass from a corroded coupon using hydrofluoric acid is presented that accelerates the throughput of sample analysis while simultaneously facilitating more accurate measurements.

Amoroso, Jake W. [Savannah River National Laborato↗

Bounded Linear Stability Analysis - A Time Delay Margin Estimation Approach for Adaptive Control

This paper presents a method for estimating time delay margin for model-reference adaptive control of systems with almost linear structured uncertainty. The bounded linear stability analysis method seeks to represent the conventional model-reference adaptive law by a locally bounded linear approximation within a small time window using the comparison lemma. The locally bounded linear approximation of the combined adaptive system is cast in a form of an input-time-delay differential equation over a small time window. The time delay margin of this system represents a local stability measure and is computed analytically by a matrix measure method, which provides a simple analytical technique for estimating an upper bound of time delay margin. Based on simulation results for a scalar model-reference adaptive control system, both the bounded linear stability method and the matrix measure method are seen to provide a reasonably accurate and yet not too conservative time delay margin estimation.

Nguyen, Nhan T.↗

How Useful are Conventional I–Vs for Performance Calibration of Single- and Two-Junction Perovskite Solar Cells? A Statistical Analysis of Performance Data on ≈200 Cells from 30 Global Sources

As perovskite photovoltaics (PV) advance from the laboratory to commercial prototypes, their accurate and reliable performance testing is becoming increasingly important. The well-documented dynamic response of perovskite solar cells to an external applied voltage has led to the development of steady-state performance measurement methods; however, these methods have not been widely adopted by the perovskite PV community. A key reason for this is that steady-state measurement methods take tens of minutes to complete, as opposed to conventional "fast" current-voltage (I-V) measurements usually lasting a few seconds. Fast I-Vs arise from a snapshot, almost always not a steady-state condition of the device; however, given their widespread use, the question arises: how do performance parameters of perovskite PV compare when measured with fast I-V and with a steady-state method? Results compiled from approximately 200 perovskite PV cells, including single junction, and two-terminal perovskite-perovskite and perovskite-Si tandems, show that fast I-Vs can provide a useful measure of the open-circuit voltage of the devices, while the short-circuit current and the overall efficiency can be widely misestimated. Here, the implications of these findings on performance testing protocols are discussed and possible options for fast and accurate testing of perovskite PV are proposed.

14 SOLAR ENERGY↗

A lipidomics platform to analyze the fatty acid compositions of non-polar and polar lipid molecular species from plant tissues: Examples from developing seeds and seedlings of pennycress (Thlaspi arvense)

The lipidome comprises the total content of molecular species of each lipid class, and is measured using the analytical techniques of lipidomics. Many liquid chromatography-mass spectrometry (LC-MS) methods have previously been described to characterize the lipidome. However, many lipidomic approaches may not fully uncover the subtleties of lipid molecular species, such as the full fatty acid (FA) composition of certain lipid classes. Here, we describe a stepwise targeted lipidomics approach to characterize the polar and non-polar lipid classes using complementary LC-MS methods. Our “polar” method measures 260 molecular species across 12 polar lipid classes, and is performed using hydrophilic interaction chromatography (HILIC) on a NH2 column to separate lipid classes by their headgroup. Our “non-polar” method measures 254 molecular species across three non-polar lipid classes, separating molecular species on their FA characteristics by reverse phase (RP) chromatography on a C30 column. Five different extraction methods were compared, with an MTBE-based extraction chosen for the final lipidomics workflow. A state-of-the-art strategy to determine and relatively quantify the FA composition of triacylglycerols is also described. This lipidomics workflow was applied to developing, mature, and germinated pennycress seeds/seedlings and found unexpected changes among several lipid molecular species. During development, diacylglycerols predominantly contained long chain length FAs, which contrasted with the very long chain FAs of triacylglycerols in mature seeds. Potential metabolic explanations are discussed. The lack of very long chain fatty acids in diacylglycerols of germinating seeds may indicate very long chain FAs, such as erucic acid, are preferentially channeled into beta-oxidation for energy production.

59 BASIC BIOLOGICAL SCIENCES↗

Statistical Performance Analysis on Approximately 320 Perovskite Single- and Two-Junction Solar Cells and Modules from >30 Global Sources

As perovskite photovoltaics (PV) advance from the laboratory to commercial prototypes, their accurate and reliable performance testing is becoming increasingly important. The well documented dynamic response of perovskite solar cells to an external applied voltage has led to the development of steady-state performance measurement methods; however, these methods have not been widely adopted by the perovskite PV community. A key reason for this is that steady-state measurement methods take tens of minutes to complete, as opposed to conventional "fast" current-voltage (I-V) measurements usually lasting a few seconds. Fast I-Vs arise from a snapshot, almost always not a steady-state condition of the device; however, given their widespread use, the question arises: how do performance parameters of perovskite PV compare when measured with fast I-V and with a steady-state method? We compile results from ca. 320 perovskite PV cells and modules, including single junction, and two-terminal perovskite-perovskite and perovskite-Si tandems, and show that fast I-Vs can provide a useful measure of the open-circuit voltage of the devices, while the short-circuit current and the overall efficiency can be widely misestimated. We discuss implications of these findings on performance testing protocols and propose possible options for fast and accurate testing of perovskite PV.

asymptotic↗

A new method to measure homogeneous nucleation rates in shock tubes

The centered expansion wave of a shock tube is utilized to expand and supersaturate a condensable vapor in small concentration in an inert carrier gas. The supersaturated state, located at the rear of the expansion wave, is preserved for a controlled period and then terminated by a recompressing shock wave. During the period of supersaturation, condensation nuclei are formed homogeneously. The nucleation rate is measured as a function of supersaturation by a Mie-light scattering technique. The method is tested using water and the results are compared with classical nucleation theory.

Peters, F.↗

Two color holographic interferometry for microgravity application

Holographic interferometry is a primary candidate for the measurement of temperature and concentration in various crystal growth experiments destined for space. The method measures refractive index changes in the experiment test cell. A refractive index change can be caused by concentration changes, temperature changes, or a combination of temperature and concentration changes. If the refractive index changes are caused by temperature and concentration changes occurring simultaneously in the experiment test cell, the contributions by the two effects cannot be separated by conventional measurement methods. By using two wavelengths, two independent interferograms can be produced from the reconstruction of the hologram. The two interferograms will be different due to dispersion properties of fluid materials. These differences provide the additional information that allows the separation of simultaneously occurring temperature and concentration gradients. There is no other technique available that can provide this type of information. The primary objectives of this effort are to experimentally verify the mathematical theory of two color holographic interferometry and to determine the practical value of this technique for space application. To achieve these objectives, the accuracy and sensitivity of the technique must be determined for geometry's and materials that are relevant to the Materials Processing in the Space program of NASA. This will be achieved through the use of a specially designed two-color holographic interferometry breadboard optical system. In addition to experiments to achieve the primary goals, the breadboard will also provide inputs to the design of an optimum space flight system.

Trolinger, James D.↗

Correlation studies on surface particle detection methods

The accurate determination of dust levels on optical surfaces is necessary to assess sensor system performance. A comparison study was made on several particle measurement methods including those based on direct imaging and light scattering. The effectiveness of removing the particles from the surface prior to determining particle size distributions was also assessed. These studies revealed that some methods, especially those requiring particle removal before analysis, are subject to large systematic errors affecting particle size distributions. Thus, an understanding of the particle measurement methods employed is necessary before any surface cleanliness or obstruction value assignments are accepted as true representations of an optical surface contamination condition.

Peterson, Ronald V.↗

A Method to Measure and Estimate Normalized Contrast in Infrared Flash Thermography

The paper presents further development in normalized contrast processing used in flash infrared thermography method. Method of computing normalized image or pixel intensity contrast, and normalized temperature contrast are provided. Methods of converting image contrast to temperature contrast and vice versa are provided. Normalized contrast processing in flash thermography is useful in quantitative analysis of flash thermography data including flaw characterization and comparison of experimental results with simulation. Computation of normalized temperature contrast involves use of flash thermography data acquisition set-up with high reflectivity foil and high emissivity tape such that the foil, tape and test object are imaged simultaneously. Methods of assessing other quantitative parameters such as emissivity of object, afterglow heat flux, reflection temperature change and surface temperature during flash thermography are also provided. Temperature imaging and normalized temperature contrast processing provide certain advantages over normalized image contrast processing by reducing effect of reflected energy in images and measurements, therefore providing better quantitative data. Examples of incorporating afterglow heat-flux and reflection temperature evolution in flash thermography simulation are also discussed.

Koshti, Ajay M.↗

Resonant x-ray scattering method for measuring cation stoichiometry in BaSnO 3 thin films

In this study, we develop a resonant scattering technique to measure cation stoichiometry of lanthanum-doped BaSnO 3 (BSO) thin films on a DyScO 3 substrate. Samples are grown by a hybrid molecular beam epitaxy method and display high room-temperature carrier mobilities. The measured thin films are grown with widely differing cation arrival rates, with Ba being evaporated from an elemental source and Sn from a SnO 2 source. Differences in mobilities in these films may arise from differences in Ba/Sn cation stoichiometry. Owing to the similar scattering strength of the Ba and Sn cations, odd-order Bragg peaks of BSO are particularly sensitive to the material's cation stoichiometry, i.e., the Ba/Sn ratio. Sensitivity to cation stoichiometry is further enhanced using the technique of resonant x-ray scattering, which changes the scattering strength of a single element across the Ba L absorption edges. We determine that the Ba/Sn cation stoichiometry varies from unity by less than 1% for films of mobility ranging from 84.8 to 144 cm 2 /(V s) and conclude that the mobility of these films scales with film thickness and growth rate rather than stoichiometry.

36 MATERIALS SCIENCE↗

Determination of Cluster Distances from Chandra Imaging Spectroscopy and Sunyaev-Zeldovich Effect Measurements: Analysis Methods and Initial Results - I

X-ray and Sunyaev-Zeldovich Effect data ca,n be combined to determine the distance to galaxy clusters. High-resolution X-ray data are now available from the Chandra Observatory, which provides both spatial and spectral information, and interferometric radio measurements of the Sunyam-Zeldovich Effect are available from the BIMA and 0VR.O arrays. We introduce a Monte Carlo Markov chain procedure for the joint analysis of X-ray and Sunyaev-Zeldovich Effect data. The advantages of this method are the high computational efficiency and the ability to measure the full probability distribution of all parameters of interest, such as the spatial and spectral properties of the cluster gas and the cluster distance. We apply this technique to the Chandra X-ray data and the OVRO radio data for the galaxy cluster Abell 611. Comparisons with traditional likelihood-ratio methods reveal the robustness of the method. This method will be used in a follow-up paper to determine the distance of a large sample of galaxy clusters for which high-resolution Chandra X-ray and BIMA/OVRO radio data are available.

Bonamente, Massimiliano↗