Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microfluidic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Microfluidic liquid sheets as large-area targets for high repetition XFELs

The high intensity of X-ray free electron lasers (XFELs) can damage solution-phase samples on every scale, ranging from the molecular or electronic structure of a sample to the macroscopic structure of a liquid microjet. By using a large surface area liquid sheet microjet as a sample target instead of a standard cylindrical microjet, the incident X-ray spot size can be increased such that the incident intensity falls below the damage threshold. This capability is becoming particularly important for high repetition rate XFELs, where destroying a target with each pulse would require prohibitively large volumes of sample. We present here a study of microfluidic liquid sheet dimensions as a function of liquid flow rate. Sheet lengths, widths and thickness gradients are shown for three styles of nozzles fabricated from isotropically etched glass. In-vacuum operation and sample recirculation using these nozzles is demonstrated. The effects of intense XFEL pulses on the structure of a liquid sheet are also briefly examined.

47 OTHER INSTRUMENTATION↗

A framework of computer vision-enhanced microfluidic approach for automated assessment of the transient sickling kinetics in sickle red blood cells

The occurrence of vaso-occlusive crisis greatly depends on the competition between the sickling delay time and the transit time of individual sickle cells, i.e., red blood cells from sickle cell disease (SCD) patients, while they are traversing the circulatory system. Many drugs for treating SCD work by inhibiting the polymerization of sickle hemoglobin (HbS), effectively delaying the sickling process in sickle cells (SS RBCs). Most previous studies on screening anti-sickling drugs, such as voxelotor, rely on in vitro testing of sickling characteristics, often conducted under prolonged deoxygenation for up to 1 hour. However, since the microcirculation of RBCs typically takes less than 1 minute, the results of these studies may be less accurate and less relevant for in vitro-in vivo correlation. In our current study, we introduce a computer vision-enhanced microfluidic framework designed to automatically capture the transient sickling kinetics of SS RBCs within a 1-min timeframe. Our study has successfully detected differences in the transient sickling kinetics between vehicle control and voxelotor-treated SS RBCs. This approach has the potential for broader applications in screening anti-sickling therapies.

59 BASIC BIOLOGICAL SCIENCES↗

Performance Evaluation of Fast Microfluidic Thermal Lysis of Bacteria for Diagnostic Sample Preparation

Development of new diagnostic platforms that incorporate lab-on-a-chip technologies for portable assays is driving the need for rapid, simple, low cost methods to prepare samples for downstream processing or detection. An important component of the sample preparation process is cell lysis. In this work, a simple microfluidic thermal lysis device is used to quickly release intracellular nucleic acids and proteins without the need for additional reagents or beads used in traditional chemical or mechanical methods (e.g., chaotropic salts or bead beating). On-chip lysis is demonstrated in a multi-turn serpentine microchannel with external temperature control via an attached resistive heater. Lysis was confirmed for Escherichia coli by fluorescent viability assay, release of ATP measured with bioluminescent assay, release of DNA measured by fluorometry and qPCR, as well as bacterial culture. Results comparable to standard lysis techniques were achievable at temperatures greater than 65 °C and heating durations between 1 and 60 s.

lab-on-a-chip↗

A microfluidic study of transient flow states in permeable media using fluorescent particle image velocimetry

Velocity fields in flow in permeable media are of great importance to many subsurface processes such as geologic storage of CO 2 , oil and gas extraction, and geothermal systems. Steady-state flow is characterized by velocity fields that do not change significantly over time. The flow field transitions to a new steady state once it experiences a disturbance such as a change in flow rate or in pressure gradient. This transition is often assumed to be instantaneous, which justifies the expression of constitutive relations as functions of instantaneous phase saturations. This work examines the evolution of velocity fields in a surrogate quasi-2D permeable medium using a microfluidic device, a microscopy system, and a high-speed camera. Tracer particles are injected into the medium along with DI water. The evolution of the velocity field is examined by tracing these particles in the captured images using the standard high-density particle image velocimetry algorithm founded on cross-correlation. The results suggest that the transition between steady states for an incompressible fluid takes a finite and non-negligible amount of time that is independent of the magnitude of the change in pressure gradient. The existence of transient states and the nature of the response during these states are readily interpreted by the principle of least action where flow gradually establishes an optimal configuration such that energy dissipation is 2 minimized. The findings provide evidence against the applicability of the assumption that flowing phases relax instantaneously to their steady states and, hence, against the accuracy of the classical multiphase extension of Darcy's law.

42 ENGINEERING↗

Microfluidic ion mobility chromatograph

This paper describes the development of a microfluidic ion mobility chromatograph for small inorganic ion analysis.

microfluids separation ion chromatography↗

Preparation of Nucleic Acid Libraries for Personalized Sequencing Systems Using an Integrated Microfluidic Hub Technology (Seventh Annual Sequencing, Finishing, Analysis in the Future (SFAF) Meeting 2012)

Kamlesh (Ken) Patel from Sandia National Laboratories (Livermore, California) presents "Preparation of Nucleic Acid Libraries for Personalized Sequencing Systems Using an Integrated Microfluidic Hub Technology " at the 7th Annual Sequencing, Finishing, Analysis in the Future (SFAF) Meeting held in June, 2012 in Santa Fe, NM.

59 BASIC BIOLOGICAL SCIENCES↗

Robust Extraction Interface for Coupling Droplet-Based and Continuous Flow Microfluidics

Reliable and highly efficient extraction of droplets from oil to aqueous phase is key for downstream coupling with chemical separations and nonoptical detection methods such as amperometry and mass spectrometry. This paper presents an improved interface providing robust extraction for droplet-based poly(dimethylsiloxane) (PDMS) microfluidic devices. The extraction interface consists of an array of cylindrical posts with narrow apertures in between. The aqueous flow channel into which droplets coalesced was simply and selectively modified to be hydrophilic, while the continuous oil phase flow channel that contained encapsulated aqueous droplets retained a hydrophobic surface. The different surfaces on both sides of the extraction region form a highly stable liquid interface between the two immiscible phases, allowing rapid droplet transfer to the aqueous stream. Entire droplets could be completely extracted within broad ranges of aqueous and oil flow rates (0 - 1 and 0.1 - 1 uL/min, respectively). After extraction, the droplet contents could be transported electrophoretically or by pressure-driven flow to a monolithically integrated emitter for nano-electrospray ionization mass spectrometry (nanoESI-MS) analysis. This interface should be amenable to the separation and identification of droplet contents and on-line monitoring of in-droplet reactions.

Based↗

Microfluidic-Based Sample Chips for Radioactive Solutions

Historical nuclear fuel cycle process sampling techniques required sample volumes ranging in the tens of milliliters. The radiation levels experienced by analytical personnel and equipment, in addition to the waste volumes generated from analysis of these samples, have been significant. These sample volumes also impacted accountability inventories of required analytes during process operations. To mitigate radiation dose and other issues associated with the historically larger sample volumes, a microcapillary sample chip was chosen for further investigation. The ability to obtain microliter volume samples coupled with a remote automated means of sample loading, tracking, and transporting to the analytical instrument would greatly improve analytical efficiency while reducing both personnel exposure and radioactive waste volumes. Sample chip testing was completed to determine the accuracy, repeatability, and issues associated with the use of microfluidic sample chips used to supply µL sample volumes of lanthanide analytes dissolved in nitric acid for introduction to an analytical instrument for elemental analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microencapsulation of Chemicals through Microfluidic-based Design and Fabrication

This presentation provides an overview of the polymer encapsulation program being conducted at LLNL in which a number of "active" materials (absorbents, catalysts, etc.) are being encapsulated in microfluidic capsule producing systems which produce particles that are solidified via UV radiation.

20 FOSSIL-FUELED POWER PLANTS↗

Creating microfluidic channels functionalized with micro- and nano-scale features via femtosecond laser surface processing

We demonstrate the ability to create functionalized microfluidic channels using femtosecond laser surface processing (FLSP). FLSP is an emerging advanced manufacturing technology used to modify the surface properties of materials directly and permanently by producing self-organized quasi-periodic micro- and nano-scale surface features along with surface and subsurface chemical and grain structure changes. We demonstrate on Hastelloy X that by controlling the laser fluence and pulse count, the depth of the microchannels and height of the FLSP microstructures within the microchannels can be controlled independently.

Ultrashort pulse laser applications, micro- and na↗

3D Printing of Compositional Gradients Using the Microfluidic Circuit Analogy

3D printing of structures with compositional gradients requires accurate dispensing control to achieve desired profiles. Here, empirical data are used with a model based on the microfluidic circuit analogy (MCA) to project dispense rate profiles that yield improved compositional accuracy in the printed part. Since minor variation in the experimental setup for each printing session can result in significant changes, a calibration procedure is developed to measure the system response. This calibration enables the extraction of the empirical MCA model parameters specific to each print session. Using the empirical parameters, the MCA model then can be used to predict appropriate dispense rates for the desired composition profile and toolpath of interest. Here, the MCA model is validated experimentally by direct ink write 3D printing of compositional gradients using viscoelastic polydimethylsiloxane inks and is shown to improve accuracy to desired profile by a factor of 2–5. This approach enables a new route to 3D print structures with arbitrarily complex compositional gradients.

36 MATERIALS SCIENCE↗

Towards microfluidic reactors for cell-free protein synthesis at the point-of-care

Cell-free protein synthesis (CFPS) is a powerful technology that allows for optimization of protein production without maintenance of a living system. Integrated within micro- and nano-fluidic architectures, CFPS can be optimized for point-of care use. Here, we describe the development of a microfluidic bioreactor designed to facilitate the production of a single-dose of a therapeutic protein, in a small footprint device at the point-of-care. This new design builds on the use of a long, serpentine channel bioreactor and is enhanced by integrating a nanofabricated membrane to allow exchange of materials between parallel reactor and feeder channels. This engineered membrane facilitates the exchange of metabolites, energy, and inhibitory species, prolonging the CFPS reaction and increasing protein yield. Membrane permeability can be altered by plasma-enhanced chemical vapor deposition and atomic layer deposition to tune the exchange rate of small molecules. This allows for extended reaction times and improved yields. Further, the reaction product and higher molecular weight components of the transcription/translation machinery in the reactor channel can be retained. As a result, we show that the microscale bioreactor design produces higher protein yields than conventional tube-based batch formats, and that product yields can be dramatically improved by facilitating small molecule exchange within the dual-channel bioreactor.

60 APPLIED LIFE SCIENCES↗

Design, Implementation, Simulation, and Visualization of a Highly Efficient RIM Microfluidic Mixer for Rapid Freeze-Quench of Biological Samples

Rapid freeze-quench (RFQ) trapping of short-lived reaction intermediates for spectroscopic study plays an important role in the characterization of biological reactions. Recently, there has been considerable effort to achieve sub-millisecond reaction deadtimes. We present here a new, robust, high-velocity microfluidic mixer that enables such rapid freeze-quenching. It is a based on the mixing method of two impinging jets commonly used in reaction injection molding of plastics. This method achieves efficient mixing by inducing chaotic flow at relatively low Reynolds numbers (Re = 140). We present the first mathematical simulation and microscopic visualization of mixing in such RFQ micromixers, the results of which show that the impinging solutions efficiently mix within the mixing chamber. These tests, along with a practical demonstration in an RFQ setup that involves copper wheels, show that this new mixer can in practice provide reaction deadtimes as low as 100 µs.

59 BASIC BIOLOGICAL SCIENCES↗

Controlled Dispensing and Mixing of Pico- to Nanoliter Volumes Using On-Demand Droplet-Based Microfluidics

We present an integrated droplet-on-demand microfluidic platform for dispensing, mixing, incubating, extracting and analyzing by mass spectrometry pico- to nanoliter sized droplets. Droplet generation is accomplished using computer-controlled pneumatic valves. Controlled actuation of valves for different aqueous streams enables controlled dosing and rapid mixing of reagents within droplets in the droplet generation area or in a region with widening channel cross-section. Following incubation, which takes place while droplets travel in the oil stream, the droplet contents are extracted to an aqueous channel for subsequent ionization at an integrated nanoelectrospray emitter. As an initial demonstration of the platform, rapid enzymatic digestions of a model protein are performed in droplets and detected on-line by nanoelectrospray ionization mass spectrometry.

Environmental Molecular Sciences Laboratory↗

Electric field effects on current–voltage relationships in microfluidic channels presenting multiple working electrodes in the weak-coupling limit

While electrochemical methods are well suited for lab-on-a-chip applications, reliably coupling multiple, electrode-controlled processes in a single microfluidic channel remains a considerable challenge, because the electric fields driving electrokinetic flow make it difficult to establish a precisely known potential at the working electrode(s). The challenge of coupling electrochemical detection with microchip electrophoresis is well known; however, the problem is general, arising in other multielectrode arrangements with applications in enhanced detection and chemical processing. Here, we study the effects of induced electric fields on voltammetric behavior in a microchannel containing multiple in-channel electrodes, using a Fe(CN) 6 3/4- model system. When an electric field is induced by applying a cathodic potential at one inchannel electrode, the half-wave potential (E 1/2 ) for the oxidation of ferrocyanide at an adjacent electrode shifts to more negative potentials. The E 1/2 value depends linearly on the electric field current at a separate in-channel electrode. The observed shift in E 1/2 is quantitatively described by a model, which accounts for the change in solution potential caused by the iR drop along the length of the microchannel. The model, which reliably captures changes in electrode location and solution conductivity, apportions the electric field potential between iR drop and electrochemical potential components, enabling the study of microchannel electric field magnitudes at low applied potentials. In the system studied, the iR component of the electric field potential increases exponentially with applied current before reaching an asymptotic value near 80 % of the total applied potential. The methods described will aid in the development and interpretation of future microchip electrochemistry methods, particularly those that benefit from the coupling of electrokinetic and electrochemical phenomena at low voltages.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microfluidic Fabrication of Nanoparticles Based on Ethyl Acrylate-Functionalized Chitosan for Adsorption of Methylene Blue from Aqueous Solutions

The adsorption of nanoparticle (NP)-based adsorbents especially those made of polymers to remove dyes as toxic substances from pollutants is yet remained as a critical issue. The objective of this work was to prepare microfluidic (MF) fabrication of NPs based on ethyl acrylate (EA)-functionalized chitosan (CS) for methylene blue (MB) dye removal from aqueous solutions. For this purpose, a series of experiments such as FTIR, SEM alongside DLS, and UV–vis spectrophotometry were carried out to investigate the physicochemical properties of the samples. The FTIR spectra showed that the amine (–NH{sub 2}) and hydroxyl (–OH) groups on CS structure were replaced with EA, appropriately. The SEM and DLS results depicted that EA-functionalized CS NPs fabricated using MF technique had uniform shapes, and the diameters as small as 70 nm compared to those samples produced via bulk mixing (BM) method (~ 300 nm). Moreover, the surface charge of MF-assisted CS NPs after functionalization exhibited the lower zeta potential value (~ + 11) than that of samples based on BM (~ + 14) due to occurring the laminar flow through the micro-channels embedded in the MF chip, leading to an increase in the MB adsorption. Subsequently, at the optimized amounts of the dye concentration (89.12 mg L{sup −1}), the adsorbent concentration (1.38 g L{sup −1}), and pH (10.58) by means of Box-Behnken design (BBD) method, the maximum percentage of MB removal by the use of MF-fabricated EA-functionalized CS NPs was 98.4%. By fitting the obtained adsorption data to the isotherm models such as Lagmuir, Freundlich, and Temkin, it has been found that the adsorption mechanism followed the Langmuir model (maximum capacity of the adsorption 384.61 mg/g), which assumed a monolayer coverage of MB molecules as adsorbates over a homogeneous adsorbent surface.

36 MATERIALS SCIENCE↗

Temperature controlled transformations of giant unilamellar vesicles of amphiphilic triblock copolymers synthesized via microfluidic mixing

We report on a simple approach for synthesis of temperature-responsive giant unilamellar vesicles (GUVs) from poly(N-vinylcaprolactam) 15 -block-poly(dimethylsiloxane) 65 -block-poly(N-vinylcaprolactam) 15 (PVCL 15 -PDMS65-PVCL 15 ) triblock copolymer and non-temperature responsive small and giant vesicles from novel poly(N-vinylpyrrolidone)-block-poly(dimethylsiloxane)-block-poly(N-vinylpyrrolidone) (PVPON 15 -PDMS 65 -PVPON 15 and PVPON 6- PDMS 30- PVPON 6 ) triblock copolymers using microfluidic mixing at 25 °C. We show that temperature-responsive PVCL 15 -PDMS 65- PVCL 15 GUVs with the average diameter of 1.4 ± 0.2 µm while being stable at room temperature for at least 14 days, transformed irreversibly into small vesicles of 168 ± 40 nm after incubation of their aqueous solution at 42 °C for 24 h. We hypothesized that this transformation is induced by local compressive stresses of the vesicle membrane due to the collapse of PVCL blocks above the copolymer lower critical solution temperature (LCST) leading to the decrease of the vesicle membrane thickness. Consequently, we found that the temperature-induced size transformation of the PVCL-based GUVs at 42°C can be suppressed by substituting PVCL with its hydrophilic homologue PVPON, or by suppressing the PVCL's LCST behavior through hydrogen-bonding with tannic acid molecules. In the former case, novel PVPON n -PDMS m -PVPON n triblock copolymers (n = 15, m = 65 and n = 6, m = 30) assemble into vesicles stable from 25 °C to 55 °C as confirmed by optical and electron microscopy, dynamic light scattering (DLS) and small-angle neutron scattering (SANS). In the latter, hydrogen bonding interactions of PVCL with the polyphenol tannic acid (TA) at room temperature resulted in stable PVCL-based GUVs at 42°C as confirmed by optical, electron, and atomic force microscopies. We also found that physical crosslinking of the PVCL corona through hydrogen bonding with TA in PVCL 15- PDMS 65- PVCL 15 GUVs will delay their low pH-induced degradation at 37°C by 48 h compared to non-modified GUVs. Our findings open opportunities for the development of temperature-regulated stable micro-vehicles that would change their structural characteristics in the physiologically relevant temperature range from 25 to 42°C and can be utilized for cell mimicking studies. The developed GUVs also have potential in theranostic drug delivery as substitutes for polymer microcapsules and lipid microbubbles as well as for stimuli-triggered sensing, protection, and rapid response in an aqueous environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Relaxation of ultralarge VWF bundles in a microfluidic-AFM hybrid reactor

The crucial role of the biopolymer 'Von Willebrand factor' (VWF) in blood platelet binding is tightly regulated by the shear forces to which the protein is exposed in the blood flow. Under high-shear conditions, VWFs ability to immobilize blood platelets is strongly increased due to a change in conformation which at sufficient concentration is accompanied by the formation of ultra large VWF bundles (ULVWF). However, little is known about the dynamic and mechanical properties of such bundles. Combining a surface acoustic wave (SAW) based microfluidic reactor with an atomic force microscope (AFM) we were able to study the relaxation of stretched VWF bundles formed by hydrodynamic stress. We found that the dynamical response of the network is well characterized by stretched exponentials, indicating that the relaxation process proceeds through hopping events between a multitude of minima. This finding is in accordance with current ideas of VWF self-association. The longest relaxation time does not show a clear dependence on the length of the bundle, and is dominated by the internal conformations and effective friction within the bundle.

60 APPLIED LIFE SCIENCES↗