Performance of a Silicon-Drift Detector in 200kV TEM Environments

Silicon-drift detectors for energy-dispersive spectroscopy have gained increasing acceptance in the field principally because of their outstanding capabilities for high count-rate performance coupled with excellent resolution [1,2]. Improvements in design in the last few years have overcome some early disadvantages of the SDD in comparison to Si(Li) detectors, which have dominated the field for nearly 4 decades. Amongst these are detection efficiency in the low-energy regime, and a dropoff in detection efficiency at higher energies above 10keV. The former disadvantage has been largely overcome by generational design improvements to minimize the effective dead layer at the entrance window, so that present detectors provide better performance in the low-energy regime than Si(Li) detectors. In the latter case, higher energy peak detection performance has been improved by increasing the thickness of the detector. This is important primarily for the use of the SDD in a TEM environment, where very high count rates are not encountered due to the thin sample geometry. Also of importance for incorporation of an SDD into a TEM column is the lack of need for liquid nitrogen, since the SDD is chilled by a thermoelectric cooler. This is an advantage for SEM and microprobe operation also, but high-resolution TEMs (particularly aberration-corrected instruments) are more sensitive to vibration than SEMs or microprobes, so the much reduced form factor of an air-cooled SDD relative to a Si(Li) detector with a large LN2 dewar is desirable for use on the TEM. We have recently tested two Bruker C

200kV TEM↗

Copper uptake, intracellular localization, and speciation in marine microalgae measured by synchrotron radiation X-ray fluorescence and absorption microspectroscopy

Metal toxicity to aquatic organisms depends on the speciation of the metal and its binding to the critical receptor site(s) (biotic ligand) of the organism. The intracellular nature of the biotic ligand for Cu in microalgal cells was investigated using the high elemental sensitivity of microprobe synchrotron radiation X-ray fluorescence (SR-XRF) and X-ray absorption near-edge spectroscopy (XANES). The marine microalgae, Ceratoneis closterium , Phaeodactylum tricornutum , and Tetraselmis sp. were selected based on their varying sensitivities to Cu (72-h 50% population growth inhibitions of 8–47 μg Cu/L). Intracellular Cu in control cells was similar for all three species (2.5–3.2 × 10–15 g Cu/cell) and increased 4-fold in C. closterium and Tetraselmis sp. when exposed to copper, but was unchanged in P. tricornutum (72-h exposure to 19, 40, and 40 μg Cu/L, respectively). Whole cell microprobe SR-XRF identified endogenous Cu in the central compartment (cytoplasm) of control (unexposed) cells. After Cu exposure, Cu was colocated with organelles/granules dense in P, S, Ca, and Si and this was clearly evident in thin sections of Tetraselmis sp. XANES indicated coexistence of Cu(I) and Cu(II) in control and Cu-exposed cells, with the Cu ligand (e.g., phytochelatin) in P. tricornutum different from that in C. closterium and Tetraselmis sp. Here, this study supports the hypothesis that Cu(II) is reduced to Cu(I) and that polyphosphate bodies and phytochelatins play a significant role in the internalization and detoxification of Cu in marine microalgae.

54 ENVIRONMENTAL SCIENCES↗

High-Temperature Thermoelectric Properties of the Solid-Solution Zintl Phase Eu 11 Cd 6 Sb 12-x As x (x < 3)

Zintl phases are compounds that have shown promise for thermoelectric applications. The title solid–solution Zintl compounds were prepared from the elements as single crystals using a tin flux for compositions x = 0, 1, 2, and 3. Eu 11 Cd 6 Sb 12–x As x (x < 3) crystallize isostructurally in the centrosymmetric monoclinic space group C2/m (no. 12, Z = 2) as the Sr 11 Cd 6 Sb 12 structure type (Pearson symbol mC58). Efforts to make the As compositions for x exceeding ~3 resulted in structures other than the Sr 11 Cd 6 Sb 12 structure type. Single-crystal X-ray diffraction indicates that As does not randomly substitute for Sb in the structure but is site specific for each composition. The amount of As determined by structural refinement was verified by electron microprobe analysis. Electronic structures and energies calculated for various model structures of Eu 11 Cd 6 Sb 10 As 2 (x = 2) indicated that the preferred As substitution pattern involves a mixture of three of the six pnicogen sites in the asymmetric unit. In addition, As substitution at the Pn4 site opens an energy gap at the Fermi level, whereas substitution at the other five pnicogen sites remains semimetallic with a pseudo gap. Thermoelectric properties of these compounds were measured on hot-pressed, fully densified pellets. Samples show exceptionally low lattice thermal conductivities from room temperature to 775 K: 0.78–0.49 W/mK for x = 0; 0.72–0.53 W/mK for x = 1; and 0.70–0.56 W/mK for x = 2. Eu 11 Cd 6 Sb 12 shows a high p-type Seebeck coefficient (from +118 to 153 μ V/K) but also high electrical resistivity (6.8 to 12.8 mΩ·cm). The value of zT reaches 0.23 at 774 K. The properties of Eu 11 Cd 6 Sb 12–x As x are interpreted in discussion with the As site substitution.

Kazem, Nasrin↗

Deposition of uranium precipitaties in dolomitic gravel fill

Uranium-containing precipitates have been observed in a dolomitic gravel fill near the Department of Energy (DOE) S-3 Ponds former waste disposal site as a result of exposure to acidic (pH 3.4) groundwater contaminated with U (33 mg L{sup -1}), Al{sup 3+} (900 mg L{sup -1}), and NO{sub 3}{sup -} (14000 mg L{sup -1}). The U containing precipitates fluoresce a bright green under ultraviolet (UV) short-wave light which identify U-rich coatings on the gravel. Scanning electron microscopy (SEM) microprobe analysis show U concentration ranges from 1.6-19.8% (average of 7%) within the coatings with higher concentrations at the interface of the dolomite fragments. X-ray absorption near edge structure spectroscopy (XANES) indicate that the U is hexavalent and extended X-ray absorption fine structure spectroscopy (EXAFS) shows that the uranyl is coordinated by carbonate. The exact nature of the uranyl carbonates are difficult to determine, but some are best described by a split K{sup +}-like shell similar to grimselite [K{sub 4}Na(UO{sub 2})(CO{sub 3}){sub 3} {center_dot} H{sub 2}O] and other regions are better described by a single Ca{sup 2+}-like shell similar to liebigite [Ca{sub 2}(UO{sub 2})(CO{sub 3}){sub 3} {center_dot} 11(H{sub 2}O)] or andersonite [Na{sub 2}CaUO{sub 2}(CO{sub 3}){sub 3} {center_dot} 6H{sub 2}O]. The U precipitates are found in the form of white to light yellow cracked-formations as coatings on the dolomite gravel and as detached individual precipitates, and are associated with amorphous basalumnite [Al{sub 4}(SO{sub 4})(OH){sub 10} {center_dot} 4H{sub 2}O].

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Distinct Fracture Mineralogy That is Out of Equilibrium With Modern Groundwaters Provides Important Context for Subsurface Life

Rock fracture surfaces in the crust are essential habitat for microorganisms. Fracture‐groundwater interfaces provide physical substrates for biofilm growth and are sources of carbon, nutrients, and electron donors and acceptors. To better understand geochemical processes impacting fracture surfaces and the subsurface microbiome, we identified fractures in archived rock cores from the Soudan formation, which is known to host saline groundwaters and isolated microbial communities dependent on rock‐water interactions. Cores with open fractures were thin sectioned and studied via electron microprobe and synchrotron X‐ray fluorescence microprobe. Most fracture surfaces had mineralogy distinct from that of the bulk rock. Chlorite minerals were abundant on fracture surfaces and had elemental compositions suggesting deposition during late‐stage hydrothermal alteration. Fracture‐lining chlorites likely limit access to iron oxide and sulfide minerals that are active in subsurface biogeochemical cycles. Calcium‐rich rinds were also observed along fracture edges. These rinds were too thin and poorly ordered to be identified via light microscopy or X‐ray diffraction; however, Ca K‐edge micro‐X‐ray absorption near‐edge structure spectroscopy identified them as carbonates, minerals not observed in the bulk rock. Thermodynamic modeling shows that carbonate precipitation is largely unfavorable in Soudan groundwaters, indicating that fracture edge conditions differed from those in modern water samples. Because of the low carbon concentrations in Soudan groundwaters, carbonate rinds likely play an important role in subsurface carbon cycling and may mark fracture surfaces that once hosted biofilms. Overall, this study suggests that fracture alteration can both play an active role in and suppress rock‐water interactions essential to subsurface life.

36 MATERIALS SCIENCE↗

Identification and physiological comparison of plant species that show positive or negative co-occurrence with selenium hyperaccumulators

Abstract In these studies we identified and compared the properties of plant species that showed positive or negative co-occurrence with selenium (Se) hyperaccumulators in their natural habitat. The main questions addressed were: which species are most abundant directly adjacent to hyperaccumulators, and which are absent? How do Se accumulation and tolerance compare in species found to positively or negatively co-occur with hyperaccumulators? Approaches included field surveys, X-ray microprobe analysis of field samples, and a lab Se tolerance and accumulation study. When 54 hyperaccumulators across two naturally seleniferous sites were surveyed for their five nearest neighboring species, and the relative abundance of these species around hyperaccumulators compared to that in the overall vegetation, some species were identified to positively or negatively co-occur with hyperaccumulators. Several positively co-occurring species showed high Se accumulation capability (up to 900 mg Se per kg dry weight), which may reflect Se tolerance. Leaf X-ray microprobe analysis found relatively more organic forms of Se in two positively co-occurring species than in a negatively co-occurring one. There were elevated soil Se levels around Se hyperaccumulators, and neighbors of Se hyperaccumulators had a higher tissue Se concentration as compared to when the same species grew elsewhere in the area. The elevated soil Se levels around Se hyperaccumulators – likely resulting from litter deposition- may significantly affect the local plant community, facilitating Se-tolerant plant community members but lowering the fitness of Se-sensitive members.

Reynolds, R. Jason B.↗

On the Applications of IBA Techniques to Biological Samples Analysis: PIXE and RBS

The analytical techniques based on ion beams or IBA techniques give quantitative information on elemental concentration in samples of a wide variety of nature. In this work, we focus on PIXE technique, analyzing thick target biological specimens (TTPIXE), using 3 MeV protons produced by an electrostatic accelerator. A nuclear microprobe was used performing PIXE and RBS simultaneously, in order to solve the uncertainties produced in the absolute PIXE quantifying. The advantages of using both techniques and a nuclear microprobe are discussed. Quantitative results are shown to illustrate the multielemental resolution of the PIXE technique; for this, a blood standard was used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Commissioning and Performance of the Soft X-ray Micro-characterization Beamline at the Canadian Light Source

The Soft X-ray Micro-characterization Beamline (SXRMB) is a medium energy, bending magnet based beamline, designed to cover an energy range of 1.7-10 keV using two sets of crystals--InSb(111) and Si(111). The design goal is to deliver a flux of 2x10{sup 11} photons sec{sup -1}/100 mA with a resolution up to 10,000 for X-ray Absorption Spectroscopy. A KB mirror stage is designed to provide microprobe capability, with a spot size of 10x10 {mu}m{sup 2} and a flux of >10{sup 9} at the microprobe station. The beamline has been in the commissioning phase since 2008, and access to the X-ray absorption endstation is now open to general users. The optical commissioning and performance of the beamline is presented with some early experimental results.

43 PARTICLE ACCELERATORS↗

Synchrotron X-ray microscopy and spectroscopy analysis of iron in hemochromatosis liver and intestines

Hemochromatosis is a genetic disorder that causes body to store excess iron in organs such as heart or liver. Distribution of iron, as well as copper, zinc and calcium, and chemical identity of iron in hemochromatosis liver and intestine were investigated by X-ray microprobe experiments, which consist of X-ray microscopy and micro-X-ray absorption fine structure. Our results show that iron concentration in hemochromatosis liver tissue is high, while much less Fe is found in intestinal tissue. Moreover, chemical identity of Fe in hemochromatosis liver can be identified. X-ray microprobe experiments allows for examining elemental distribution at an excellent spatial resolution. Moreover, chemical identity of element of interest can be obtained.

43 PARTICLE ACCELERATORS↗

Synchrotron X-rays reveal the modes of Fe binding and trace metal storage in the brown algae Laminaria digitata and Ectocarpus siliculosus

Abstract Iron is accumulated symplastically in kelp in a non-ferritin core that seems to be a general feature of brown algae. Microprobe studies show that Fe binding depends on tissue type. The sea is generally an iron-poor environment and brown algae were recognized in recent years for having a unique, ferritin-free iron storage system. Kelp (Laminaria digitata) and the filamentous brown alga Ectocarpus siliculosus were investigated using X-ray microprobe imaging and nanoprobe X-ray fluorescence tomography to explore the localization of iron, arsenic, strontium, and zinc, and micro-X-ray absorption near-edge structure (μXANES) to study Fe binding. Fe distribution in frozen hydrated environmental samples of both algae shows higher accumulation in the cortex with symplastic subcellular localization. This should be seen in the context of recent ultrastructural insight by cryofixation–freeze substitution that found a new type of cisternae that may have a storage function but differs from the apoplastic Fe accumulation found by conventional chemical fixation. Zn distribution co-localizes with Fe in E. siliculosus, whereas it is chiefly located in the L. digitata medulla, which is similar to As and Sr. Both As and Sr are mostly found at the cell wall of both algae. XANES spectra indicate that Fe in L. digitata is stored in a mineral non-ferritin core, due to the lack of ferritin-encoding genes. We show that the L. digitata cortex contains mostly a ferritin-like mineral, while the meristoderm may include an additional component.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a High-Rate Front-End ASIC for X-Ray Spectroscopy and Diffraction Applications

We developed a new front-end application-specific integrated circuit (ASIC) to upgrade the Maia X-ray microprobe. The ASIC instruments 32 configurable channels that perform either positive or negative charge amplification, pulse shaping, peak amplitude, and time extraction along with buffered analog storage. At a gain of 3.6 V/fC, 1-μs peaking time, and a temperature of 248 K, an electronic resolution of 13 and 10 e- rms was measured with and without a silicon drift detector (SDD) sensor, respectively. A spectral resolution of 170-eV full-width at half-maximum (FWHM) at 5.9 keV was obtained with an 55Fe source. The channel linearity was better than ± 1% with rate capabilities up to 40 kcps. The ASIC was fabricated in a commercial 250-nm process with a footprint of 6.3 mm × 3.9 mm and dissipates 167 mW of static power.

Vernon, Emerson↗

Viscosities and working region predictions for bismuth aluminoborosilicate glasses

Bismuth aluminoborosilicate glasses were prepared using a standard melt-quench technique, and the viscosity and thermal properties were measured and analyzed. Electron microprobe analysis was used to examine glass homogeneity. Fragility was calculated based on Mauro–Yue–Ellison–Gupta–Allan model fits to the viscosity curves. The system is characterized by an open structure with high fragility (44-59). Based on microanalysis and differential scanning calorimetry results, the addition of network intermediate Al2O3 appears to mitigate both phase separation and crystallization. From thermal property data, mixture models were created to predict the glass transition temperatures and softening temperatures as functions of composition. Based on K-fold validation findings, the first-order mixture model predictions of glass transition and softening appear to approximate actual values better than models with any additional second-order terms.

Gardner, Levi↗

Copper and angiogenesis : unravelling a relationship key to cancer progression.

Angiogenesis, the formation of new capillaries from existing vasculature, is a critical process in normal physiology as well as several physiopathologies. A desire to curb the supportive role angiogenesis plays in the development and metastasis of cancers has driven exploration into anti-angiogenic strategies as cancer therapeutics. Key to this, angiogenesis additionally displays an exquisite sensitivity to bioavailable copper. Depletion of copper has been shown to inhibit angiogenesis in a wide variety of cancer cell and xenograft systems. Several clinical trials using copper chelation as either an adjuvant or primary therapy have been conducted. Yet, the biological basis for the sensitivity of angiogenesis remains unclear. Numerous molecules important to angiogenesis regulation have been shown to be either directly or indirectly influenced by copper, yet a clear probative answer to the connection remains elusive. Measurements of copper in biological systems have historically relied on techniques that, although demonstrably powerful, provide little or no information as to the spatial distribution of metals in a cellular context. Therefore, several new approaches have been developed to image copper in a biological context. One such approach relies on synchrotron-derived X-rays from third-generation synchrotrons and the technique of high resolution X-ray fluorescence microprobe (XFM) analysis. Recent applications of XFM approaches to the role of copper in regulating angiogenesis have provided unique insight into the connection between copper and cellular behaviour. Using XFM, copper has been shown to be highly spatially regulated, as it is translocated from perinuclear areas of the cell towards the tips of extending filopodia and across the cell membrane into the extracellular space during angiogenic processes. Such findings may explain the heightened sensitivity of this cellular process to this transition metal and set a new paradigm for the kinds of regulatory roles that the spatial dynamics of cellular transition metals may play.

43 PARTICLE ACCELERATORS↗

The strain-dependent spatial evolution of garnet in a high- P ductile shear zone from the Western Gneiss Region (Norway): a synchrotron X-ray microtomography study

Reaction and deformation microfabrics provide key information to understand the thermodynamic and kinetic controls of tectono-metamorphic processes, however they are usually analysed in two dimensions, omitting important information regarding the third spatial dimension. We applied synchrotron-based X-ray microtomography to document the evolution of a pristine olivine gabbro into a deformed omphacite-garnet eclogite in four dimensions, where the 4th dimension is represented by the degree of strain. In the investigated samples, which cover a strain gradient into a shear zone from the Western Gneiss Region (Norway), we focused on the spatial transformation of garnet coronas into elongated clusters of garnets with increasing strain. Our microtomographic data allowed quantification of garnet volume, shape and spatial arrangement evolution with increasing strain. We combined microtomographic observations with light microscope- and backscatter electron images as well as electron microprobe- (EMPA) and electron backscatter diffraction (EBSD) analysis to correlate mineral composition and orientation data with the X-ray absorption signal of the same mineral grains. With increasing deformation, the garnet volume almost triples. In the low strain domain, garnets form a well interconnected large garnet aggregate that develops throughout the entire Page 1 of 52 sample. We also observed that garnet coronas in the gabbros never completely encapsulate olivine grains. In the most highly deformed eclogites, the oblate shapes of garnet clusters reflect a deformational origin of the microfabrics. We interpret the aligned garnet aggregates to direct synkinematic fluid flow and consequently influence the transport of dissolved chemical components. EBSD analyses reveal that garnet show a near-random crystal preferred orientation that testifies no evidence for crystal plasticity. There is, however evidence for minor fracturing, neo-nucleation and overgrowth. Microprobe chemical analysis revealed that garnet compositions progressively equilibrate to eclogite facies, becoming more almandine-rich. We interpret these observations as pointing to a mechanical disintegration of the garnet coronas during strain localisation, and their rearrangement into individual garnet clusters through a combination of garnet coalescence and overgrowth while the rock was deforming.

garnet↗

Fast Charging of Li-Ion Cells: Part I. Using Li/Cu Reference Electrodes to Probe Individual Electrode Potentials

Increasing the charge rate of Li-ion cells over 1–2C (full charge in 30–60 min) would be highly desirable, but high currents flowing through the active materials push these cells to their endurance limits. In this article, we aim to understand how such high-current regimes affect electrochemical properties of the cells. Formation of Li metal deposits is a recognized hazard of high-rate charging, as Li plating can overtake lithium intercalation in the negative electrode. Here we demonstrate how microprobe Li/Cu reference electrodes can be used to characterize the graphite anode and layered oxide (NCM523) cathode during constant-current (≤ 6C) voltage-limited (4.39 V) charging of Li-ion cells. These reference electrodes are used to monitor the onset of Li plating conditions in situ during cell charging. As the current increases over 3C, the anode potentials decrease below -40 mV causing lithium nucleation. Surprisingly, this nucleation (at least, initially) does not result in capacity fade or a higher anode impedance even in strongly polarized cells, so it appears that the nascent Li nuclei are isolated from electrolyte by the pre-existing solid electrolyte interphase. Our study shows that microprobe reference electrodes are an important diagnostic tool to characterize full-cell behavior in the high-current regimes.

25 ENERGY STORAGE↗

Fast, High-Resolution X-ray Microfluorescence Imaging

X-ray micro fluorescence imaging refers to the use of an x-ray beam as a probe to excite XRF in a specimen and produce a spatially resolved image of the element distribution. The advantages of high sensitivity and low background, together with the nondestructive nature of the measurement, have lead to applications of x-ray microfluorescence analysis in biology, geology, materials science, as well as in the area of nondestructive evaluation. Previous reports have described the development of an x-ray microprobe which uses a conventional source of x-rays to produce a 10-μm beam. This paper describes improvements to the microprobe which have increased the beam power and the solid angle of detection. The data collection and display software have also been enhanced.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hyperspectral image reconstruction for x-ray fluorescence tomography

A penalized maximum-likelihood estimation is proposed to perform hyperspectral (spatio-spectral) image reconstruction for X-ray fluorescence tomography. The approach minimizes a Poisson-based negative log-likelihood of the observed photon counts, and uses a penalty term that has the effect of encouraging local continuity of model parameter estimates in both spatial and spectral dimensions simultaneously. The performance of the reconstruction method is demonstrated with experimental data acquired from a seed of arabidopsis thaliana collected at the 13-ID-E microprobe beamline at the Advanced Photon Source. The resulting element distribution estimates with the proposed approach show significantly better reconstruction quality than the conventional analytical inversion approaches, and allows for a high data compression factor which can reduce data acquisition times remarkably. In particular, this technique provides the capability to tomographically reconstruct full energy dispersive spectra without compromising reconstruction artifacts that impact the interpretation of results.

Fluorescence microscopy↗

Transition metals in the transition zone: Crystal chemistry of minor element substitution in wadsleyite

As the most abundant solid phase at depths of 410 to 525 km, wadsleyite constitutes a large geochemical reservoir in the Earth. In order to better understand the implications of minor element substitution and cation ordering in wadsleyite, we have synthesized wadsleyites coexisting with pyroxenes with about 3 wt% of either TiO 2 , Cr 2 O 3 , V 2 O 3 , CoO, NiO, or ZnO under hydrous conditions in separate experiments at 1300 °C and 15 GPa. We have refined the crystal structures of these wadsleyites by single-crystal X-ray diffraction, analyzed the compositions by electron microprobe, and estimated M3 vacancy concentration from b/a cell-parameter ratios. According to the crystal structure refinements, trivalent cations Fe 3+ , Cr 3+ and V 3+ , show a strong preference for M3 over M1 and M2 and significant substitution up to 2.7 % (atomic percent) at the tetrahedral site (T site). Divalent cations, Ni 2+ , Co 2+ , and Zn 2+ show site preferences similar to those of Fe2+ with M1≈ M3 > M2 > T. Transition metal site preferences appear to correlate with crystal field stabilization energies (CFSE) and are inconsistent with cation radius effects. The avoidance of Ni 2+ , Co 2+ and Fe 2+ for the M2 site in both wadsleyite and olivine can be influenced by CFSE, which has a positive correlation with site preferences at octahedral sites, indicating that avoidance of the lower-symmetry M2 site is stronger for cations having lower (greater absolute value) CFSE. Ti 4+ substitutes primarily into the M3 octahedron, rather than M1, M2, or T sites. Electron microprobe analysis reveals that Ti 4+ , Cr 3+ , and V 3+ have greater solubility in wadsleyite than in olivine. Furthermore these transition metal cations may be enriched in a melt or an accessory phase if hydrous melting occurs on upward convection across the wadsleyite-olivine boundary and may be useful as indicators of high pressure origin.