Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motion Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Steerable Hopping Six-Legged Robot

The figure depicts selected aspects of a six-legged robot that moves by hopping and that can be steered in the sense that it can be launched into a hop in a controllable direction. This is a prototype of hopping robots being developed for use in scientific exploration of rough terrain on remote planets that have surface gravitation less than that of Earth. Hopping robots could also be used on Earth, albeit at diminished hopping distances associated with the greater Earth gravitation. The upper end of each leg is connected through two universal joints to an upper and a lower hexagonal frame, such that the tilt of the leg depends on the relative position of the two frames. Two non-back-driveable worm-gear motor drives are used to control the relative position of the two frames along two axes 120 apart, thereby controlling the common tilt of all six legs and thereby, further, controlling the direction of hopping. Each leg includes an upper and a lower aluminum frame segment with a joint between them. A fiberglass spring, connected via hinges to both segments, is used to store hopping energy prior to launch into a hop and to cushion the landing at the end of the hop. A cable for loading the spring is run into each leg through the center of the universal joints and then down along the center lines of the segments to the lower end of the leg. A central spool actuated by a motor with a harmonic drive and an electromagnetic clutch winds in all six cables to compress all six springs (thereby also flexing all six legs) simultaneously. To ensure that all the legs push off and land in the same direction, timing- belt pulley drives are attached to the leg segments, restricting the flexing and extension of all six legs to a common linear motion. In preparation for a hop, the spool can be driven to load the spring legs by an amount corresponding to a desired hop distance within range. The amount of compression can be computed from the reading of a shaft-angle encoder that indicates the amount by which the spool has been turned. When the robot is ready to hop, the electromagnetic clutch disengages the motor from the spool, thus releasing the cable restraints on the springs and allowing the springs to extend all six legs simultaneously.

Younse, Paulo↗

Planetary Suit Hip Bearing Model for Predicting Design vs. Performance

Designing a planetary suit is very complex and often requires difficult trade-offs between performance, cost, mass, and system complexity. In order to verifying that new suit designs meet requirements, full prototypes must eventually be built and tested with human subjects. Using computer models early in the design phase of new hardware development can be advantageous, allowing virtual prototyping to take place. Having easily modifiable models of the suit hard sections may reduce the time it takes to make changes to the hardware designs and then to understand their impact on suit and human performance. A virtual design environment gives designers the ability to think outside the box and exhaust design possibilities before building and testing physical prototypes with human subjects. Reductions in prototyping and testing may eventually reduce development costs. This study is an attempt to develop computer models of the hard components of the suit with known physical characteristics, supplemented with human subject performance data. Objectives: The primary objective was to develop an articulating solid model of the Mark III hip bearings to be used for evaluating suit design performance of the hip joint. Methods: Solid models of a planetary prototype (Mark III) suit s hip bearings and brief section were reverse-engineered from the prototype. The performance of the models was then compared by evaluating the mobility performance differences between the nominal hardware configuration and hardware modifications. This was accomplished by gathering data from specific suited tasks. Subjects performed maximum flexion and abduction tasks while in a nominal suit bearing configuration and in three off-nominal configurations. Performance data for the hip were recorded using state-of-the-art motion capture technology. Results: The results demonstrate that solid models of planetary suit hard segments for use as a performance design tool is feasible. From a general trend perspective, the suited performance trends were comparable between the model and the suited subjects. With the three off-nominal bearing configurations compared to the nominal bearing configurations, human subjects showed decreases in hip flexion of 64%, 6%, and 13% and in hip abduction of 59%, 2%, and 20%. Likewise the solid model showed decreases in hip flexion of 58%, 1%, and 25% and in hip abduction of 56%, 0%, and 30%, under the same condition changes from the nominal configuration. Differences seen between the model predictions and the human subject performance data could be attributed to the model lacking dynamic elements and performing kinematic analysis only, the level of fit of the subjects with the suit, the levels of the subject s suit experience.

Cowley, Matthew S.↗

The Effect of Anode Configuration on the Plasma Plume of a 25-A class Hollow Cathode

The effect of anode configuration on the plasma plume properties of a 25-A class hollow cathode are experimentally characterized. At a nominal operating condition of 20.8 A and 14.7 sccm of xenon, the cathode was operated with two axially-segmented anodes of different diameters at varying distance from the cathode. A fast, reciprocating motion stage was used to rapidly insert an ion saturation probe and an emissive probe on cathode centerline, and from those measurements, spatial profiles of plasma density, plasma potential, and electron temperature were calculated. For both anode diameters, maximum plasma potential and electron temperature increased with increasing anode distance. However, the 64-mm diameter anode was found to be significantly more sensitive to position, with measurements indicating that parameters changed continuously with position instead of an instantaneous mode change at a certain critical distance. The 254-mm diameter, in contrast, showed much more similar plasma property profiles across the range of anode positions tested and much smaller changes per unit increase in distance. These results are discussed in the context of assessing anode design for component-level cathode tests.

Space propulsion↗

The Effect of Anode Configuration on the Plasma Plume of a 25-A class Hollow Cathode

The effect of anode configuration on the plasma plume properties of a 25-A class hollow cathode are experimentally characterized. At a nominal operating condition of 20.8 A and 14.7 sccm of xenon, the cathode was operated with two axially-segmented anodes of different diameters at varying distance from the cathode. A fast, reciprocating motion stage was used to rapidly insert an ion saturation probe and an emissive probe on cathode centerline, and from those measurements, spatial profiles of plasma density, plasma potential, and electron temperature were calculated. For both anode diameters, maximum plasma potential and electron temperature increased with increasing anode distance. However, the 64-mm diameter anode was found to be significantly more sensitive to position, with measurements indicating that parameters changed continuously with position instead of an instantaneous mode change at a certain critical distance. The 254-mm diameter, in contrast, showed much more similar plasma property profiles across the range of anode positions tested and much smaller changes per unit increase in distance. These results are discussed in the context of assessing anode design for component-level cathode tests.

space propulsion↗

ROTATING MOTIONS AND MODELING OF THE ERUPTING SOLAR POLAR-CROWN PROMINENCE ON 2010 DECEMBER 6

A large polar-crown prominence composed of different segments spanning nearly the entire solar disk erupted on 2010 December 6. Prior to the eruption, the filament in the active region part split into two layers: a lower layer and an elevated layer. The eruption occurs in several episodes. Around 14:12 UT, the lower layer of the active region filament breaks apart: One part ejects toward the west, while the other part ejects toward the east, which leads to the explosive eruption of the eastern quiescent filament. During the early rise phase, part of the quiescent filament sheet displays strong rolling motion (observed by STEREO-B) in the clockwise direction (viewed from east to west) around the filament axis. This rolling motion appears to start from the border of the active region, then propagates toward the east. The Atmospheric Imaging Assembly (AIA) observes another type of rotating motion: In some other parts of the erupting quiescent prominence, the vertical threads turn horizontal, then turn upside down. The elevated active region filament does not erupt until 18:00 UT, when the erupting quiescent filament has already reached a very large height. We develop two simplified three-dimensional models that qualitatively reproduce the observed rolling and rotating motions. The prominence in the models is assumed to consist of a collection of discrete blobs that are tied to particular field lines of a helical flux rope. The observed rolling motion is reproduced by continuous twist injection into the flux rope in Model 1 from the active region side. Asymmetric reconnection induced by the asymmetric distribution of the magnetic fields on the two sides of the filament may cause the observed rolling motion. The rotating motion of the prominence threads observed by AIA is consistent with the removal of the field line dips in Model 2 from the top down during the eruption.

79 ASTRONOMY AND ASTROPHYSICS↗

Motion as perturbation. II. Development of the method for dosimetric analysis of motion effects with fixed-gantry IMRT

Purpose: In this work, the feasibility of implementing a motion-perturbation approach to accurately estimate volumetric dose in the presence of organ motion—previously demonstrated for VMAT-–is studied for static gantry IMRT. The method's accuracy is improved for the voxels that have very low planned dose but acquire appreciable dose due to motion. The study describes the modified algorithm and its experimental validation and provides an example of a clinical application. Methods: A contoured region-of-interest is propagated according to the predefined motion kernel throughout time-resolved 4D phantom dose grids. This timed series of 3D dose grids is produced by the measurement-guided dose reconstruction algorithm, based on an irradiation of a staticARCCHECK (AC) helical dosimeter array (Sun Nuclear Corp., Melbourne, FL). Each moving voxel collects dose over the dynamic simulation. The difference in dose-to-moving voxel vs dose-to-static voxel in-phantom forms the basis of a motion perturbation correction that is applied to the corresponding voxel in the patient dataset. A new method to synchronize the accelerator and dosimeter clocks, applicable to fixed-gantry IMRT, was developed. Refinements to the algorithm account for the excursion of low dose voxels into high dose regions, causing appreciable dose increase due to motion (LDVE correction). For experimental validation, four plans using TG-119 structure sets and objectives were produced using segmented IMRT direct machine parameters optimization in Pinnacle treatment planning system (v. 9.6, Philips Radiation Oncology Systems, Fitchburg, WI). All beams were delivered with the gantry angle of 0°. Each beam was delivered three times: (1) to the static AC centered on the room lasers; (2) to a static phantom containing a MAPCHECK2 (MC2) planar diode array dosimeter (Sun Nuclear); and (3) to the moving MC2 phantom. The motion trajectory was an ellipse in the IEC XY plane, with 3 and 1.5 cm axes. The period was 5 s, with the resulting average motion speed of 1.45 cm/s. The motion-perturbed high resolution (2 mm voxel) volumetric dose grids on the MC2 phantom were generated for each beam. From each grid, a coronal dose plane at the detector level was extracted and compared to the corresponding moving MC2 measurement, using gamma analysis with both global (G) and local (L) dose-error normalization. Results: Using the TG-119 criteria of (3%G/3 mm), per beam average gamma analysis passing rates exceeded 95% in all cases. No individual beam had a passing rate below 91%. LDVE correction eliminated systematic disagreement patterns at the beams’ aperture edges. In a representative example, application of LDVE correction improved (2%L/2 mm) gamma analysis passing rate for an IMRT beam from 74% to 98%. Conclusions: The effect of motion on the moving region-of-interest IMRT dose can be estimated with a standard, static phantom QA measurement, provided the motion characteristics are independently known from 4D CT or otherwise. The motion-perturbed absolute dose estimates were validated by the direct planar diode array measurements, and were found to reliably agree with them in a homogeneous phantom.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NMR relaxation of the orientation of single segments in semiflexible dendrimers

We study the orientational properties of labeled segments in semiflexible dendrimers making use of the viscoelastic approach of Dolgushev and Blumen [J. Chem. Phys. 131, 044905 (2009)]. We focus on the segmental orientational autocorrelation functions (ACFs), which are fundamental for the frequency-dependent spin-lattice relaxation times T{sub 1}(ω). We show that semiflexibility leads to an increase of the contribution of large-scale motions to the ACF. This fact influences the position of the maxima of the [1/T{sub 1}]-functions. Thus, going from outer to inner segments, the maxima shift to lower frequencies. Remarkably, this feature is not obtained in the classical bead-spring model of flexible dendrimers, although many experiments on dendrimers manifest such a behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Component response to random vibratory motion of the carrier vehicle

Two physical models of component plus supporting substructure are considered. Each model consists of a rigid body attached to a moving base by means of linear springs and viscous dampers. The second model differs from the first in that its dampers are elastically supported. The first model receives the more extensive treatment. Base motion, assumed a random translational motion parallel to a fixed axis, is prescribed only to the extent that the power spectral density (PSD) of its acceleration is given; and, as given, its plot on log-log graph paper is a series of straight line segments, each segment having an extremity in common with the adjacent segment. Closed expressions are given for the mean squares of base acceleration, base velocity, and base displacement. The component is restricted to planar motion and allowed two degrees of freedom, one translational and one rotational. Integral expressions are given for the mean squares of component response variables, the transfer functions essential to mean square computation being available via the equations of motion. Closed expressions are given for mean squares of certain of the response variables for the case wherein the base acceleration PSD is constant.

Tuell, L. P.↗

A new pulsed laser deposition technique: Scanning multi-component pulsed laser deposition method

The scanning multi-component pulsed laser deposition (PLD) method realizes uniform depositions of desired coatings by a modified pulsed laser deposition process, preferably with a femto-second laser-system. Multi-component coatings (single or multilayered) are thus deposited onto substrates via laser induced ablation of segmented targets. This is achieved via horizontal line-scanning of a focused laser beam over a uniformly moving target's surface. This process allows to deposit the desired composition of the coating simultaneously, starting from the different segments of the target and adjusting the scan line as a function of target geometry. The sequence and thickness of multilayers can easily be adjusted by target architecture and motion, enabling inter/intra layer concentration gradients and thus functional gradient coatings. This new, simple PLD method enables the achievement of uniform, large-area coatings. Case studies were performed with segmented targets containing aluminum, titanium, and niobium. Under the laser irradiation conditions applied, all three metals were uniformly ablated. The elemental composition within the rough coatings obtained was fixed by the scanned area to Ti-Al-Nb = 1:1:1. Crystalline aluminum, titanium, and niobium were found to coexist side by side at room temperature within the substrate, without alloy formation up to 600 deg. C.

36 MATERIALS SCIENCE↗

Rubidium-82 PET imaging is feasible in a rat myocardial infarction model

Background: Small-animal myocardial infarct models are frequently used in the assessment of new cardioprotective strategies. A validated quantification of perfusion using a non-cyclotron-dependent PET tracer would be of importance in monitoring response to therapy. We tested whether myocardial PET perfusion imaging is feasible with Rubidium-82 ({sup 82}Rb) in a small-animal scanner using a rat myocardial infarct model. Methods: 18 Sprague-Dawley rats underwent permanent coronary artery ligation (infarct group), and 11 rats underwent ischemia-reperfusion (reperfusion group) procedure. {sup 82}Rb-PET and magnetic resonance imaging (MRI) were conducted before and after the intervention. Perfusion was compared to both left ventricle ejection fraction (LVEF) and infarct size assessed by MRI. Results: Follow-up global {sup 82}Rb-uptake correlated significantly with infarct size (infarct group: r = −0.81, P < 0.001 and reperfusion group: r = −0.61, P = 0.04). Only {sup 82}Rb-uptake in the infarct group correlated with LVEF. At follow-up, a higher segmental {sup 82}Rb-uptake in the infarct group was associated with better wall motion (β = 0.034, CI [0.028;0.039], P < 0.001, R{sup 2} = 0.30), and inversely associated with scar transmurality (β = −2.4 [−2.6; −2.2], P < 0.001, R{sup 2} = 0.59). The associations were similar for the reperfusion group. Conclusion: {sup 82}Rb-PET is feasible in small animal scanners despite the long positron range and enables fast and time-efficient myocardial perfusion imaging in rat models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Charging and Release Mechanisms of Flexible Macromolecules in Droplets

We study systematically the charging and release mechanisms of a flexible macromolecule, modeled by poly(ethylene glycol) (PEG), in a droplet by using molecular dynamics simulations. We compare how PEG is solvated and charged by sodium Na{sup +} ions in a droplet of water (H{sub 2}O), acetonitrile (MeCN), and their mixtures. Initially, we examine the location and the conformation of the macromolecule in a droplet bearing no net charge. It is revealed that the presence of charge carriers do not affect the location of PEG in aqueous and MeCN droplets compared with that in the neutral droplets, but the location of the macromolecule and the droplet size do affect the PEG conformation. PEG is charged on the surface of a sodiated aqueous droplet that is found close to the Rayleigh limit. Its charging is coupled to the extrusion mechanism, where PEG segments leave the droplet once they coordinate a Na{sup +} ion or in a correlated motion with Na{sup +} ions. In contrast, as PEG resides in the interior of a MeCN droplet, it is sodiated inside the droplet. The compact macro-ion transitions through partially unwound states to an extended conformation, a process occurring during the final stage of desolvation and in the presence of only a handful of MeCN molecules. For charged H{sub 2}O/MeCN droplets, the sodiation of PEG is determined by the H{sub 2}O component, reflecting its slower evaporation and preference over MeCN for solvating Na{sup +} ions. We use the simulation data to construct an analytical model that suggests that the droplet surface electric field may play a role in the macro-ion–droplet interactions that lead to the extrusion of the macro-ion. This study provides the first evidence of the effect of the surface electric field by using atomistic simulations. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Bare-tether cathodic contact through thermionic emission by low-work-function materials

A new material, C12A7:e{sup -} electride, which might present a work function as low as 0.6 eV and moderately high temperature stability, was recently proposed as coating for floating bare tethers. Arising from heating under space operation, current is emitted by thermionic emission along a thus coated cathodic segment. A preliminary study on the space-charge-limited (SCL) double layer in front of the cathodic segment is presented using Langmuir's SCL electron current between cylindrical electrodes and orbital-motion-limited ion-collection sheath. A detailed calculation of current and bias profiles along the entire tether length is carried out with ohmic effects and the transition from SCL to full Richardson-Dushman emission included. Analysis shows that in the simplest drag mode, under typical orbital and tether conditions, thermionic emission leads to a short cathodic section and may eliminate the need for an active cathodic device and its corresponding gas feed requirements and power subsystem, which results in a truly 'propellant-less' tether system for such basic applications as de-orbiting low earth orbit satellites.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An optimal Space Shuttle ascent trajectory for the first orbital flight test

An optimal solution of the ascent trajectory of the Space Shuttle for the first orbital flight test is presented; the optimization is a minimum propellant, four-control problem in yaw angle, roll angle, pitch angle and vacuum thrust of each Space Shuttle main engine. Piecewise linear segments with juncture points treated as parameters are employed to model the controls. Equations of motion for a three-dimensional flight with pitch plane moment balance about an oblate are integrated numerically with a fourth-order Runge-Kutta method; two- and one-dimensional cubic spline function curve fits of aerodynamic coefficients are used during the first and second stages, respectively. The constraint minimization problem is solved with the Davidon-Fletcher-Powell function method.

Johnson, I. L., Jr.↗

Spatial vision within egocentric and exocentric frames of reference

It is remarkable that we are able to perceive a stable visual world and judge the directions, orientations, and movements of visual objects given that images move on the retina, the eyes move in the head, the head moves on the body, and the body moves in space. An understanding of the mechanisms underlying perceptual stability and spatial judgements requires precise definitions of relevant coordinate systems. An egocentric frame of reference is defined with respect to some part of the observer. There are four principal egocentric frames of reference, a station-point frame associated with the nodal point of the eye, an retinocentric frame associated with the retina, a headcentric frame associated with the head, and a bodycentric frame (torsocentric) associated with the torso. Additional egocentric frames can be identified with respect to any segment of the body. An egocentric task is one in which the position, orientation, or motion of an object is judged with respect to an egocentric frame of reference. A proprioceptive is a special kind of egocentric task in which the object being judged is also part of the body. An example of a proprioceptive task is that of directing the gaze toward the seen or unseen toe. An exocentric frame of reference is external to the observer. Geographical coordinates and the direction of gravity are examples of exocentric frames of reference. These various frames are listed in tabular form, together with examples of judgements of each type.

Howard, Ian P.↗

Design of a High Resolution Hexapod Positioning Mechanism

This paper describes the development of a high resolution, six-degree of freedom positioning mechanism. This mechanism, based on the Stewart platform concept, was designed for use with the Developmental Comparative Active Optics Telescope Testbed (DCATT), a ground-based technology testbed for the Next Generation Space Telescope (NGST). The mechanism provides active control to the DCATT telescope's segmented primary mirror. Emphasis is on design decisions and technical challenges. Significant issues include undesirable motion properties of PZT-inchworm actuators, testing difficulties, dimensional stability and use of advanced composite materials. Supporting test data from prototype mechanisms is presented.

Britt, Jamie↗

Design of a High Resolution Hexapod Positioning Mechanism

This paper describes the development of a high resolution, six-degree of freedom positioning mechanism. This mechanism, based on the Stewart platform concept, was designed for use with the Developmental Comparative Active Optics Telescope Testbed (DCATT), a ground-based technology testbed for the Next Generation Space Telescope (NGST). The mechanism provides active control to the DCATT telescope's segmented primary mirror. Emphasis is on design decisions and technical challenges. Significant issues include undesirable motion properties of PZT-inchworm actuators, testing difficulties, dimensional stability, and use of advanced composite materials. Supporting test data from prototype mechanisms is presented.

Britt, Jamie↗

Pursuit Eye Movements

When viewing objects, primates use a combination of saccadic and pursuit eye movements to stabilize the retinal image of the object of regard within the high-acuity region near the fovea. Although these movements involve widespread regions of the nervous system, they mix seamlessly in normal behavior. Saccades are discrete movements that quickly direct the eyes toward a visual target, thereby translating the image of the target from an eccentric retinal location to the fovea. In contrast, pursuit is a continuous movement that slowly rotates the eyes to compensate for the motion of the visual target, minimizing the blur that can compromise visual acuity. While other mammalian species can generate smooth optokinetic eye movements - which track the motion of the entire visual surround - only primates can smoothly pursue a single small element within a complex visual scene, regardless of the motion elsewhere on the retina. This ability likely reflects the greater ability of primates to segment the visual scene, to identify individual visual objects, and to select a target of interest.

Krauzlis, Rich↗