Parametric Analysis of Holdup in HEPA Filters

This technical document (TECH) contains an analysis of several conditions deemed credible for plutonium oxide buildup in high-efficiency air particulate (HEPA) filters to determine the effect of holdup inside the filter on reactivity. This document is performed in accordance with NCS-AP-005, R3 [Ref. (1)].

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Lithium Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility

One of the main goals of the Thermal/Epithermal eXperiments (TEX) project is to use existing Nuclear Criticality Safety Program (NCSP) assets to create critical experiment plutonium and uranium test beds for materials important to criticality safety that have insufficient benchmark evaluations. The plutonium test bed experiments were completed in 2018 and are published in the 2020 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The uranium test bed assemblies were completed in 2023 and accepted in the 2024 edition of the ICSBEP Handbook. The Nuclear Criticality Safety (NCS) group at Y-12 National Security Complex has identified programmatic need for validation cases for uranium electrorefining operations at Y-12. The electrorefining operation credits lithium enriched in 6 Li in addition to 35 Cl as absorbers in the design criticality safety evaluation for precluding criticality under upset conditions in the large and geometrically unfavorable electro-refiner. There is, however, inadequate experimental validation for the 6 Li absorbers. As an extension of the TEX uranium test bed, TEX-Cl critical experiments were performed with sodium chloride salt to address the 35 Cl thermal absorption as well as other validation needs at Los Alamos National Laboratory (LANL). These experiments were completed in 2024 and accepted into the 2025 ICSBEP Handbook. To continue the methodology used in TEX-Cl, TEX-Li aims to accomplish the same. The overall design of both experiments was to use commercially available, high purity, salts with polyethylene moderator and HEU plates to configure a critical assembly. Three experiments are planned for TEX-Li using encapsulated lithium carbonate (Li 2 CO 3 ), with natural 6 Li abundance. For all experiments, the highly enriched uranium (HEU) Jemima plates will be used as fissile material. Multiple layers will be stacked together with encapsulated Li 2 CO 3 alternated with polyethylene in standard configurations. Standard stacking was found to be optimal in matching the different sensitivity profiles provided by the Y-12 models. Three configurations are proposed with varying polyethylene moderation and a constant 1/4” absorber thickness. The first uses 11 layers of 5/4” polyethylene, the second uses 9 layers of 3/4” polyethylene, and the third uses 10 layers of 1/2” polyethylene. Calculations showed that some alternative forms of lithium-based materials provided slightly less-optimal sensitivity profiles when compared to lithium carbonate but come with other drawbacks. These alternatives included lithium aluminate (LiAlO 2 ), Aluminum-2050 alloy, Aluminum-8090, Aluminum-2095, lithium hydride (LiH), and lithium fluoride (LiF). Lithium aluminate and aluminum-2050 provided comparable sensitivity profiles when compared to lithium carbonate and can be used instead if lithium carbonate cannot be readily procured. After a broad material study, lithium carbonate outperformed any alternative material with a balance in affordability and workability. The assessment of experimental uncertainties of the non-absorber and absorber components was predicted to be 0.00089 and 0.00093 Δk eff , respectively. The largest uncertainties may be reduced with precision dimensional inspection of the components. Many of the parts and equipment for IER 575 have already been fabricated or procured for previous projects and therefore do not contribute significantly to the overall cost of this experiment. This includes the Jemima plates and Comet critical assembly machine, which are existing NCSP assets, as well as the aluminum platen and polyethylene reflector rings, which were fabricated and authorized for the TEX experiment involving HEU with polyethylene. Lithium carbonate containers will be procured by LANL and will be filled by LLNL. The total material costs for TEX-Li experiments are estimated to be on the order of $\$$47,400. Precision inspection, including dimensional, mass, density, and impurity, is recommended for all components for an estimated cost of $\$$12,000.

35Cl↗

Rapid and Efficient Deposition of Metal Oxide Coatings for Bearings and Gears in Harsh Environments

The objective of this project is to develop Tribocoating; an innovative, rapid, low-cost, energy-efficient, and environmentally friendly coating technology designed to enhance the performance and durability of bearings and gears operating under harsh conditions. Tribocoating creates protective metal-oxide tribofilms through in-situ tribosintering of nanocrystals (NCs). Components are simply run in a nano-enabled Tribocoating fluid prior to deployment; no surface pretreatment, coating equipment, or external energy input is required.

17 WIND ENERGY↗

Evaluation of Candidate Theranostics for 227 Th/ 89 Zr Paired Radioimmunotherapy of Lymphoma

227 Th is a promising radioisotope for targeted α-particle therapy. It produces 5 α-particles through its decay, with the clinically approved 223 Ra as its first daughter. There is an ample supply of 227 Th, allowing for clinical use; however, the chemical challenges of chelating this large tetravalent f-block cation are considerable. Using the CD20-targeting antibody ofatumumab, we evaluated chelation of 227 Th 4+ for α-particle–emitting and radiotheranostic applications. Methods: We compared 4 bifunctional chelators for thorium radiopharmaceutical preparation: S-2-(4-Isothiocyanatobenzyl)-1,4,7,10-tetraazacyclododecane tetraacetic acid (p-SCN-Bn-DOTA), 2-(4-isothicyanatobenzyl)-1,2,7,10,13-hexaazacyclooctadecane-1,4,7,10,13,16-hexaacetic acid (p-SCN-Bn-HEHA), p-isothiacyanatophenyl-1-hydroxy-2-oxopiperidine-desferrioxamine (DFOcyclo*-p-Phe-NCS), and macrocyclic 1,2-HOPO N-hydroxysuccinimide (L804-NHS). Immunoconstructs were evaluated for yield, purity, and stability in vitro and in vivo. Tumor targeting of the lead 227 Th-labeled compound in vivo was performed in CD20-expressing models and compared with a companion 89 Zr-labeled PET agent. Results: 227 Th-labeled ofatumumab-chelator constructs were synthesized to a radiochemical purity of more than 95%, excepting HEHA. 227 Th-HEHA-ofatumumab showed moderate in vitro stability. 227 Th-DFOcyclo*-ofatumumab presented excellent 227 Th labeling efficiency; however, high liver and spleen uptake was revealed in vivo, indicative of aggregation. 227 Th-DOTA-ofatumumab labeled poorly, yielding no more than 5%, with low specific activity (0.08 GBq/g) and modest long-term in vitro stability (<80%). 227 Th-L804-ofatumumab coordinated 227 Th rapidly and efficiently at high yields, purity, and specific activity (8 GBq/g) and demonstrated extended stability. In vivo tumor targeting confirmed the utility of this chelator, and the diagnostic analog, 89 Zr-L804-ofatumumab, showed organ distribution matching that of 227 Th to delineate SU-DHL-6 tumors. Conclusion: Commercially available and novel chelators for 227 Th showed a range of performances. The L804 chelator can be used with potent radiotheranostic capabilities for 89 Zr/ 227 Th quantitative imaging and α-particle therapy.

227Th↗

A Subcritical Assembly for Training and Education Use at the Oak Ridge National Laboratory

A near-final design has been completed for a new subcritical assembly at Oak Ridge National Laboratory (ORNL). This subcritical assembly will support the Nuclear Criticality Safety Program (NCSP) training and education program to augment current subcritical assembly capabilities at Sandia National Laboratories (SNL) and at the National Criticality Experiments Research Center (NCERC). Other collaborations have been proposed with the Sunrise Consortium and others. This proposed subcritical assembly uses legacy AGN-201M research reactor fuel plates that are available from the Y-12 National Security Complex. This subcritical assembly contains approximately 620 grams of 235 U as UO 2 particulates distributed homogeneously in radiation-stabilized polyethylene. The fuel plates will have a graphite neutron reflector to obtain a core multiplication, M, from 10 to 50, corresponding to a k eff of 0.9 to 0.95, respectively. The subcritical assembly will be able to support at least four experiments for the training courses: (1) the addition of fissile material to increase neutron multiplication (mass), (2) a core separation experiment (interaction), (3) the effect of adding moderators to the core (moderation), and (4) the effect of adding neutron absorbers to the core (poison/absorption). The proposed ORNL subcritical assembly will provide additional student bandwidth to support NCSP training courses and to provide for some backup capacity if nuclear facility operations are disrupted at SNL or NCERC due to some unforeseen issue. The subcritical assembly will be designed to be an inherently safe subcritical assembly—subcritical under all normal and abnormal conditions—and it will provide the capability to conduct hands-on training to support NCSP and general nuclear criticality safety (NCS) staff training and qualification goals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ORNL Neutron Cross Section Measurements of 90 Zr NCSP ND-1 Task [Slides]

Luiz Leal's idea to integrate the experimental uncertainties, covariances, and sensitivities in the ND workflow and to centralize the process at one location created a cohesive tool for data testing. It has been practiced for more than two decades by the NCS and ND groups at ORNL. The development and use of the ORNL codes TSUNAMI and TSURFER within SCALE made it possible. Today, it has been extended to SAMINT, which enables the coupling of differential and integral data evaluation in a continuous-energy framework.

43 PARTICLE ACCELERATORS↗

A Subcritical Assembly for Training and Education Use at the Oak Ridge National Laboratory [Abstract]

A near-final design has been completed for a new subcritical assembly at Oak Ridge National Laboratory (ORNL). This subcritical assembly will support the Nuclear Criticality Safety Program (NCSP) training and education program to augment current subcritical assembly capabilities at Sandia National Laboratories (SNL) and at the National Criticality Experiments Research Center (NCERC). Other collaborations have been proposed with the Sunrise Consortium and others. This proposed subcritical assembly uses legacy AGN-201M research reactor fuel plates that are available from the Y-12 National Security Complex. This subcritical assembly contains approximately 620 grams of 235 U as UO 2 particulates distributed homogeneously in radiation-stabilized polyethylene. The fuel plates will have a graphite neutron reflector to obtain a core multiplication, M, from 10 to 50, corresponding to a k eff of 0.9 to 0.95, respectively. The subcritical assembly will be able to support at least four experiments for the training courses: (1) the addition of fissile material to increase neutron multiplication (mass), (2) a core separation experiment (interaction), (3) the effect of adding moderators to the core (moderation), and (4) the effect of adding neutron absorbers to the core (poison/absorption). The proposed ORNL subcritical assembly will provide additional student bandwidth to support NCSP training courses and to provide for some backup capacity if nuclear facility operations are disrupted at SNL or NCERC due to some unforeseen issue. The subcritical assembly will be designed to be an inherently safe subcritical assembly—subcritical under all normal and abnormal conditions—and it will provide the capability to conduct hands-on training to support NCSP and general nuclear criticality safety (NCS) staff training and qualification goals.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CHALLENGES IN THE DEVELOPMENT OF THE ELECTROREFINING PROCESS AT Y-12

In order to ensure future capabilities of the Y-12 site as older buildings retire, a new process was developed, the Metal Purification Process. The purpose of this new process is to provide a simpler and more efficient uranium metal purification that the previous multi-staged, complex chemical processes. The basis for this technology currently exists in the US DOE complex, but it has not been utilized on a large scale for uranium at higher enrichments. The system requires larger-geometry vessels and furnaces in order to meet the through-put requirements. The crux of the process is the electrorefining cell, consisting of several concentric liners and an unfavorable geometry cylindrical crucible. Within the crucible, a molten Li-CL-KCL-UCL3 salt electrolyte is present. ‘Dirty’ metal is placed into a loading basket and loaded into an electrorefining cell. Here, the metal reacts into the molten salt within the cell to form UCL3, while ‘clean’ metal simultaneously plates out from the salt electrolyte in the form of metal dendrites. These dendrites are then collected and removed from the cell. After removal from the cell, the dendrites are taken to a furnace to remove adhered salts. Then, the salt-free dendrites are moved to a separate furnace for consolidation into the final product form. The development of the Criticality Safety Evaluation for this complex system brought with it many NCS Challenges and lessons learned. These challenges include: design decisions for ensuring subcriticalty in the electrorefining cell during abnormal conditions, the interface of the main glovebox system with auxiliary systems such as the purification system and designated storage, implementation of mass tracking, and concerns from production and operation regarding the movement of material within the system.

36 MATERIALS SCIENCE↗

Domestic and international consensus standards for nuclear criticality safety – overview & status [Abstract]

The domestic and international consensus standards for nuclear criticality safety (NCS) were developed as the lessons-learned from process criticality accidents. These consensus standards were developed to reduce the rate of process criticality accidents in facilities that process, store, handle or transport fissionable materials by hand. After a significant increase in criticality accidents through the mid-1960’s, the rate of criticality accidents decreased due to these standards and the criticality accident rate is extremely low from an industrial safety perspective.

ANS↗

Nuclear Data Libraries Sensitivity Studies for ORSA Using SCALE

Subcritical assemblies offer valuable training capabilities in nuclear criticality safety (NCS) for individuals handling fissile material. At Oak Ridge National Laboratory(ORNL), the Oak Ridge Subcritical Assembly (ORSA), a new experimental facility, is being established to provide hands-on training for the Nuclear Criticality Safety Program (NCSP).It is essential to accurately determine the neutron multiplication factor (keff) to ensure that ORSA remains subcritical and safe during operations. This study investigated the sensitivity of keff to variations across Evaluated Nuclear Data File (ENDF/B) libraries, consisting of ENDF/B-VII.1, ENDF/B-VIII.0, and ENDF/B-VIII.1. The analysis was conducted using the CSAS6 sequence in the SCALE-6.3 code system. Individual isotopes in the ORSA model were replaced one at a time with ENDF/B-VII.1 as the base library and changing to ENDF/B-VIII.0or ENDF/B-VIII.1. The results demonstrated that the changes in keffof the nuclides associated with the ORSA model were mostly within the uncertainty of the base model (~24 pcm), except for primary nuclides like Uranium-235and H-poly with few other nuclides. The relative delta keff values of Uranium-235 and H-poly, expressed in pcm, were +280 and -212 in ENDF/B-VIII.0 and +332 and -275 in ENDF/B-VIII.1, respectively, which were notable changes in reactivity. These results demonstrated that ORSA was largely insensitive to variations across these nuclear data libraries.

Hong, Evan [North Carolina State University]↗

Solvent Hold Tank Sample Results for MCU-19-557- 558-559 (July 2019), MCU-19-560-561-562 (August 2019), MCU-19-566-567-568 (September 2019) (Quarterly Report)

In late FY13, MCU implemented the Next Generation Solvent (NGS) flow sheet. Facility personnel added a non-radioactive, NGS “cocktail” containing the new Extractant (MaxCalix) and a new Suppressor (TiDG) to the SHT heel to implement the NGS flow sheet. The resulting “blend” solvent (“NGS blend solvent”) is essentially NGS with residual amounts of calix[4]arene-bis(tert-octylbenzo-crown-6) (BOBCalixC6) and trioctylamine (TOA). For process monitoring, SHT samples are sent to Savannah River National Laboratory (SRNL) to examine solvent composition changes over time. With the exception of Isopar™ L which is regularly added to the SHT due to its high vapor pressure, this report shows the cumulative chemical composition data, including impurities like mercury, of three SHT samples: MCU-19-557-558-559, MCU- 19-560-561-562, and MCU-19-566-567-568. A summary report for each of the SHT monthly samples was issued previously. This report examines the cumulative results from these and several past monthly reports.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CAAS-3S Radiation Testing for Y-12 and UPF with Godiva-IV

The Y-12 National Security Complex and the Uranium Processing Facility (UPF) selected the Mirion CAAS-3S as the Criticality Accident Alarm System for UPF and for Y-12 facilities replacing their legacy CAAS as part of efforts to extend the facility lifespans. As part of this process, the CAAS-3S system was exposed to a high radiation dose and dose rate during reactor testing with the Godiva-IV fast burst reactor. The reactor testing was designed around preliminary analyses that determined Y-12 and UPF requirements, and simulations of the radiation field within the reactor facility were used to determine reactor operating parameters, CAAS equipment locations, and the design of a neutron shield wall. This paper presents the design and results of the testing, and discusses how the test results were interpreted by criticality safety engineers at Y-12 and UPF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗