Search NASA⌕ Search

SEARCH · Search NASA

Results for “NSLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Design and Measurement of the NSLS II Quadrupole Prototypes

The design and measurement of the NSLS-II ring quadrupoles prototypes are presented. These magnets are part of a larger prototype program described in [1]. Advances in software, hardware, and manufacturing have led to some new level of insight in the quest for the perfect magnet design. Three geometric features are used to minimize the first three allowed harmonics by way of optimization. Validations through measurement and confidence levels in calculations are established.

43 PARTICLE ACCELERATORS↗

Accelerator Physics Challenges for the NSLS-II Project

The NSLS-II is an ultra-bright synchrotron light source based upon a 3-GeV storage ring with a 30-cell (15 super-period) double-bend-achromat lattice with damping wigglers used to lower the emittance below 1 nm. In this paper, we discuss the accelerator physics challenges for the design including: optimization of dynamic aperture; estimation of Touschek lifetime; achievement of required orbit stability; and analysis of ring impedance and collective effects.

43 PARTICLE ACCELERATORS↗

NSLS-II Lattice Optimization with Damping Wigglers

NSLS-II, the third-generation light source which will be built at BNL is designed and optimized for 3 GeV energy, ultra-small emittance and high intensity of 500 mA. It will provide very bright synchrotron radiation over a large spectral range from IR to hard X-rays. Damping wigglers (DWs) are deployed to reduce the emittance of 2 nm by factors of 2-4, as well as for intense radiation sources for users. The linear and nonlinear effects induced by the DWs are integrated into the lattice design. In this paper, we discuss the linear and nonlinear optimization with DWs, and present a solution satisfying the injection and lifetime requirements. Our approach could be applied to the other light sources with strong insertion devices.

43 PARTICLE ACCELERATORS↗

Alternative Designs for the NSLS-II Injection Straight Section

Brookhaven National Laboratory (BNL) is developing a state-of-the-art 3 GeV synchrotron light source, the NSLS-II [1]. The 9.3 meter-long injection straight section of its storage ring now fits a conventional injection set-up consisting of four kickers producing a closed bump, together with a DC septum and a pulsed septum. In this paper, we analyze an alternative option based on injection via a pulsed sextupole magnet. We discuss the dynamics of the injected and stored beams and, subsequently, the magnet's specifications and tolerances. We conclude by summarized the advantages and drawbacks of each injection scheme.

43 PARTICLE ACCELERATORS↗

Microwave Instability Simulations for NSLS-II

Potential-well distortion and the microwave instability in the NSLS-II storage ring are investigated. The longitudinal wakepotential is calculated as a sum of the contributions due to vacuum chamber components distributed around the ring. An approximation to the wakepotential for a 0.05-mm charge distribution length, much shorter than the 4.5-mm length of the unperturbed circulating bunch, is used as a pseudo-Green's function for beam dynamics simulations. Comparison of particle tracking simulations using the TRANFT code with the Haissinski solution shows good agreement below the instability threshold current. Above threshold two regimes are observed: (1) energy spread and bunch length are time-dependent (saw tooth behavior); (2) both are time-independent.

43 PARTICLE ACCELERATORS↗

Development of High Stability Supports for NSLS-II RF BPMS

The NSLS-II Light Source being built at Brookhaven National Laboratory is expected to provide submicron stability of the electron orbit in the storage ring in order to fully utilize the very small emittances of the electron beam. This requires high stability supports for BPM pickup electrodes located near insertion device sources. Here we provide details for the design and development of these supports as well as measurement of thermal and vibrational stability of a prototype support.

43 PARTICLE ACCELERATORS↗

Top-Off Safety Analysis for NSLS-II

Top-off injection will be adopted in NSLS-II. To ensure no injected beam can pass into experimental beamlines with open photon shutters during top-off injection, simulation studies for possible machine fault scenarios are required. We compare two available simulation methods, backward (H. Nishimura-LBL) and forward tracking (A. Terebilo-SLAC). We also discuss the tracking settings, fault scenarios, apertures and interlocks considered in the analysis.

43 PARTICLE ACCELERATORS↗

Comparison of RF BPM Receivers for NSLS-II Project

The NSLS-II Light Source being built at Brookhaven National Laboratory requires submicron stability of the electron orbit in the storage ring in order to utilize fully very small emittances and electron beam sizes. This sets high stability requirements for beam position monitors and a program has been initiated for the purpose of characterizing RF beam position monitor (BPM) receivers in use at other light sources. Present state-of-the-art performance will be contrasted with more recently available technologies.

43 PARTICLE ACCELERATORS↗

Beam Based Calibration of Slow Orbit Bump in the NSLS Booster

The orbit bumps in NSLS booster are used to move the beam orbit within 2mm of the extraction septum aperture on a time scale of millisecond at extraction in order to reduce the requirement on the amplitude of the fast extraction kicker. This may cause charge losses since before extraction, the beam stays on the distorted orbit for thousands of revolutions. In order to find the optimal orbit bump setpoint, which brings the maximum distortion at the extraction position and minimum distortions everywhere else, we developed an extraction model and performed an experiment to validate it. Afterwards, the model was applied to optimize the extraction process.

43 PARTICLE ACCELERATORS↗

The NSLS-II Multilayer Laue Lens Deposition System

The NSLS-II[1] program has a requirement for an unprecedented level of x-ray nanofocusing and has selected the wedged multilayer Laue lens[2,3] (MLL) as the optic of choice to meet this goal. In order to fabricate the MLL a deposition system is required that is capable of depositing depth-graded and laterally-graded multilayers with precise thickness control over many thousands of layers, with total film growth in one run up to 100m thick or greater. This machine design expounds on the positive features of a rotary deposition system[4] constructed previously for MLLs and will contain multiple stationary, horizontally-oriented magnetron sources where a transport will move a substrate back and forth in a linear fashion over shaped apertures at well-defined velocities to affect a multilayer coating.

43 PARTICLE ACCELERATORS↗

Cryogenic Field Measurement of Pr2Fe14B Undulator and Performance Enhancement Options at the NSLS-II

Short period (14.5mm) hybrid undulator arrays composed of Praseodymium Iron Boron (Pr{sub 2}Fe{sub 14}B) magnets (CR53, NEOMAX, Inc.) and vanadium permendur poles have been fabricated at Brookhaven National Laboratory. Unlike Neodymium Iron Boron (Nd{sub 2}Fe{sub 14}B) magnets which exhibit spin reorientation at temperatures below 150K, PrFeB arrays monotonically increase performance with lower operating temperature. It opens up the posibility for use in operating a cryo-permanent magnet undulator (CPMU) in the range of 40K to 60K where very efficient cryocoolers are available. Magnetic flux density profiles were measured at various temperature ranges from room temperature down to liquid helium (LHe) using the Vertical Testing Facility (VTF) at the National Snchrotron Light Source-II (NSLS-II). Temperature variations of phase error have been characterized. In addition, we examined the use of textured Dysprosium (Dy) poles to replace permendur poles to obtain further improvement in performance.

36 MATERIALS SCIENCE↗

Responsivity of Diamond X-ray Photodiodes Calibrated at NSLS

Single crystal, high purity synthetic diamond is used as photoabsorption and carrier transport medium in x-ray photodiodes. While the thermal / mechanical robustness and high x-ray transmission of diamond make such devices attractive for synchrotron instrumentation, state-of-the-art quality material and electrical interfaces further make such detectors feasible. The present work develops methodology for attaining calculable responsivity (photocurrent yield) over a wide range of photon energies (0.2 to 28 keV) to within 5% accuracy. These methods achieve linear response for up to 0.2 W absorbed x-ray power and response time as low as 1 ns. Details of contact formation / robustness and bias configuration are explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NSLS-II biomedical beamlines for micro-crystallography, FMX, and for highly automated crystallography, AMX: New opportunities for advanced data collection

We present the final design of the x-ray optics and experimental stations of two macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source-II. The microfocusing FMX beamline will deliver a flux of ∼5×10{sup 12} ph/s at 1 Å into a 1 – 20 µm spot, its flux density surpassing current MX beamlines by up to two orders of magnitude. It covers an energy range from 5 – 30 keV. The highly automated AMX beamline is optimized for high throughput, with beam sizes from 4 – 100 µm, an energy range of 5 – 18 keV and a flux at 1 Å of ∼10{sup 13} ph/s. A focus in designing the beamlines lay on achieving high beam stability, for example by implementing a horizontal bounce double crystal monochromator at FMX. A combination of compound refractive lenses and bimorph mirror optics at FMX supports rapid beam size changes. Central components of the in-house developed experimental stations are horizontal axis goniometers with a target sphere of confusion of 100 nm, piezo-slits for dynamic beam size changes during diffraction experiments, dedicated secondary goniometers for data collection from specimen in crystallization plates, and next generation pixel array detectors. FMX and AMX will support a broad range of biomedical structure determination methods from serial crystallography on micron-sized crystals, to structure determination of complexes in large unit cells, to rapid sample screening and room temperature data collection of crystals in trays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Remote Access to the PXRR Macromolecular Crystallography Facilities at the NSLS

The most recent surge of innovations that have simplified and streamlined the process of determining macromolecular structures by crystallography owes much to the efforts of the structural genomics community. However, this was only the last step in a long evolution that saw the metamorphosis of crystallography from an heroic effort that involved years of dedication and skill into a straightforward measurement that is occasionally almost trivial. Many of the steps in this remarkable odyssey involved reducing the physical labor that is demanded of experimenters in the field. Other steps reduced the technical expertise required for conducting those experiments.

59 BASIC BIOLOGICAL SCIENCES↗

Simulation and optimization of the NSLS-II SRX beamline combining ray-tracing and wavefront propagation

The Sub-micron Resolution X-ray spectroscopy (SRX) beamline will benefit from the ultralow emittance of the National Synchrotron Light Source II to address a wide variety of scientific applications studying heterogeneous systems at the sub-micrometer scale. This work focuses on the KB branch ({Delta}E: 4.65-28 keV). Its main optical components include a horizontally focusing mirror forming an adjustable secondary source, a horizontally deflecting monochromator and two sets of Kirkpatrick-Baez mirrors as focusing optics of two distinct inline stations for operations requiring either high flux or high resolution. In the first approach, the beamline layout was optimized with ray-tracing calculations involving Shadowvui computer codes. As a result, the location and characteristics of optics were specified for achieving either the most intense or the smallest monochromatic beam possible on the target (10{sup 13} ph/s or 10{sup 12} ph/s respectively in a 500 nm or 65 nm focal spot). At the nanoprobe station, the diffraction limited focusing of X-rays is governed by the beam coherence. Hence, a classical geometric approach is not anymore adapted. To get reliable estimates of the Nanoprobe performances, a wavefront propagation study was performed using Synchrotron Radiation Workshop (SRW) code. At 7.2 keV, calculations show an intense (10{sup 12} ph/s) 67 nm wide diffraction limited spot achieved with actual metrological data of mirrors.

43 PARTICLE ACCELERATORS↗

NSLS-II RF Cryogenic System

The National Synchrotron Light Source II is a 3 GeV X-ray user facility commissioned in 2014. A new helium refrigerator system has been installed and commissioned to support the superconducting RF cavities in the storage ring. Special care was taken to provide very stable helium and LN2 pressures and flow rates to minimize microphonics and thermal effects at the cavities. Details of the system design along with commissioning and early operations data will be presented.

43 PARTICLE ACCELERATORS↗

Timing Jitter Characterization at the NSLS SDL

Two novel timing jitter measurement techniques with a 100 fs resolution are presented in this paper. The first technique based on the Schottky effect, is used to measure the timing jitter between the photoinjector drive laser and the RF system; and it was employed to characterize the environment effects on the timing jitter. The I/Q beam monitor based on a stripline beam position monitor (BPM) is used to characterize the electron beam arrival time jitter.

43 PARTICLE ACCELERATORS↗