Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Method and apparatus for convection control of metallic halide vapor density in a metallic halide laser

An apparatus is disclosed in which a reservoir containing copper chloride is heated so that the copper chloride is maintained in a liquid form. The apparatus includes a means for flowing a buffer gas (which in the exemplary embodiment is neon) over the liquid copper chloride to provide a mixture of copper chloride vapor and neon above the liquid copper chloride. A conduit provides fluid communication between the reservoir containing the copper chloride vapor/neon mixture and the laser. The copper chloride vapor density in the laser is related to the liquid copper chloride temperature and the neon flow rate through the reservoir. In accordance with a further feature of the exemplary embodiment, neon is also provided directly to the laser in order to provide a further means of controlling the copper chloride vapor density in the laser.

Pivirotto, T. J.↗

On the interpretation and implications of nova abundances: An abundance of riches or an overabundance of enrichments

We reexamine the question of the frequency of occurrence of oxygen-neon-magnesium (ONeMg) degenerate dwarfs in classical nova systems, in light of recent observations which have been interpreted as suggesting that 'neon novae' can be associated with relatively low mass white dwarfs. Determinations of heavy-element concentrations in nova ejecta are reviewed, and possible interpretations of their origin are examined. We conclude that, of the 18 classical novae for which detailed abundance analyses are availble, only two (or possibly three) seem unambiguously to demand the presence of an underlying ONeMg white dwarf: V693 CrA 1981, V1370 Aql 1982, and possibly QU Vul 1984. Three other novae which exhibit significant neon enrichments, relative to their total heavy-element concentrations, are RR Pic 1925, V977, Sco 1989, and LMC 1990 No. 1. This result is entirely consistent with present frequency estimates, and our interpretation of the lower levels of enrichment in other systems explains, in a natural way, the existence of relatively low mass white dwarfs in some of the 'neon' novae.

Livio, Mario↗

Compact, Highly Stable Ion Atomic Clock

A mercury-ion clock now at the breadboard stage of development (see figure) has a stability comparable to that of a hydrogen-maser clock: In tests, the clock exhibited an Allan deviation of between 2 x 10(exp -13) and 3 x 10(exp -13) at a measurement time of 1 second, averaging to about 10(exp -15) at 1 day. However, the clock occupies a volume of only about 2 liters . about a hundredth of the volume of a hydrogen-maser clock. The ion-handling parts of the apparatus are housed in a sealed vacuum tube, wherein only a getter pump is used to maintain the vacuum. Hence, this apparatus is a prototype of a generation of small, potentially portable high-precision clocks for diverse ground- and space-based navigation and radio science applications. Furthermore, this new ion-clock technology is about 100 times more stable and precise than the rubidium atomic clocks currently in use in the NAV STAR GPS Earth-orbiting satellites. In this clock, mercury ions are shuttled between a quadrupole and a 16-pole linear radio-frequency trap. In the quadrupole trap, the ions are tightly confined and optical state selection from a Hg-202 radio-frequency-discharge ultraviolet lamp is carried out. In the 16-pole trap, the ions are more loosely confined and atomic transitions resonant at frequency of about 40.507 GHz are interrogated by use of a microwave beam at that frequency. The trapping of ions effectively eliminates the frequency pulling caused by wall collisions inherent to gas-cell clocks. The shuttling of the ions between the two traps enables separation of the state-selection process from the clock microwave- resonance process, so that each of these processes can be optimized independently of the other. The basic ion-shuttling, two-trap scheme as described thus far is not new: it has been the basis of designs of prior larger clocks. The novelty of the present development lies in major redesigns of its physics package (the ion traps and the vacuum and optical subsystems) to effect the desired reduction of size to a volume of no more than a couple of liters. The redesign effort has included selection of materials for the vacuum tube, ion trap, and ultraviolet windows that withstand bakeout at a temperature of approx.450 C in preparation for sealing the tube to contain the vacuum. This part of the redesign effort follows the approach taken in the development of such other vacuum-tube electronic components as flight traveling- wave-tube amplifiers having operational and shelf lives as long as 15 years. The redesign effort has also included a thorough study of residual-gas-induced shifts of the ion-clock frequency and a study of alternative gases as candidates for use as a buffer gas within the sealed tube. It has been found that neon is more suitable than is helium, which has been traditionally used for this purpose, in that the pressure-induced frequency pulling by neon is between a third and a half of that of helium. In addition, because neon diffuses through solids much more slowly than does helium, the loss of neon by diffusion over the operational lifetime is expected to be negligible.

Prestage, John↗

Compatibility of divertor detachment and ELM suppression in DIII-D high- β p plasmas with ITER-similar shape

Abstract Integration of transient and steady-state divertor heat fluxes control with a high-performance core is necessary for future fusion reactors. In recent DIII-D high- β p experiments, divertor detachment and simultaneous edge localized mode (ELM) suppression are demonstrated while the plasma confinement quality is maintained high in ITER-similar shape. By optimizing the neon injection in high- β p scenario with ITER-similar shape, deep detachment and ELM suppression are achieved with a high-performance core ( β N ∼ 2.8, β p ∼ 2.3) at q 95 ∼ 7.5. Partial divertor detachment and suppression of large ELMs are achieved at q 95 ∼ 6. The stability analyses suggest that with low neon injection, the density pedestal becomes higher and steeper and the T i profile also increases, therefore the increased edge pressure and higher current density destabilize the Peeling-Ballooning mode (PBM), which would lead to a large ELM collapse. With strong neon gas puffing, the significantly reduced pedestal pressure and current density, due to the degraded T e pedestal, lead to the stabilization of PBM and ELMs are suppressed. For both cases, the coupling between the large radius internal transport barrier (ITB) and edge pedestal is the key reason for maintaining high global performance. The formation of large radius ITB compensates for pedestal degradation. Such results could provide an attractive scenario to well control the transient and steady-state heat flux onto the divertor plates while maintaining good plasma performance, which is an important step toward the steady-state operation of future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data-driven method to estimate contamination from light ion beam transmutation at colliders

Collisions of relativistic light ions, such as oxygen, neon, and magnesium, have been proposed as a way to examine the system-size dependence of dynamics typically associated with the quark-gluon plasma produced in collisions of heavier ions such as xenon, gold, or lead. Recent efforts at both the Relativistic Heavy Ion Collider (RHIC) and Large Hadron Collider (LHC) have produced large datasets of proton-oxygen, oxygen-oxygen, and neon-neon collisions, catalyzing intense interest in experimental backgrounds associated with light-ion collisions. In particular, electromagnetic dissociation of light ions while they are circulating in a collider can result in beam contamination that is difficult to simulate precisely. Here we propose a data-driven method for evaluating the potential impact of beam contaminants on physics analyses. The method exploits the time dependence and smaller size of contaminant ion species to define control regions that can be used to quantify potential contamination effects. A simple model is used to illustrate the method and to study its robustness. Furthermore, this method can inform studies of recent LHC and RHIC data and could also be useful for future light-ion programs at the LHC and beyond.

Beam loss↗

Wind River Experimental Forest Subcanopy Tower Information Sheet

Wind River was one of three sites that collected 3d sonic anemometer data for an ICOS subcanopy observation study. The three sites were defined by the following features and terrain: a deciduous broadleaf forest in flat terrain (Lanžhot, Czech Republic), a coniferous forest in mountainous terrain (Renon, Italy), and a tall conifer forest in mountain-valley terrain (Wind River, USA). The Wind River subcanopy towers were deployed in a high LAI, old-growth evergreen conifer forest and collected approximately 11 months of data. The site is an ecologically rich temperate rainforest in the western Cascade Mountains, and the biological carbon sink and source strength has been measured since 1998 using eddy covariance on the top of a 74 m tall flux tower (currently called the Wind River NEON tower). Additionally, forest inventory records date back to the 1920s. In 2024, four subcanopy towers were installed near the Wind River NEON tower to measure wind flow in the understory canopy layer for better understanding canopy flow coupling and decoupling in the subcanopy and how this affects the interpretation of overstory fluxes. The subcanopy tower installation was done by Lawrence Livermore National Laboratory and Washington State University (WSU) with collaborations from the University of Utah and the National Ecological Observatory Network (NEON).

54 ENVIRONMENTAL SCIENCES↗

A data-driven method to estimate contamination from light ion beam transmutation at colliders

Collisions of relativistic light ions such as oxygen, neon, and magnesium, have been proposed as a way to examine the system-size dependence of dynamics typically associated with the quark-gluon plasma produced in collisions of heavier ions such as xenon, gold, or lead. Recent efforts at both the Relativistic Heavy Ion Collider (RHIC) and Large Hadron Collider (LHC) have produced large datasets of proton-oxygen, oxygen-oxygen, and neon-neon collisions, catalyzing intense interest in experimental backgrounds associated with light ion collisions. In particular, electromagnetic dissociation of light ions while they are circulating in a collider can result in beam contamination that is difficult to simulate precisely. Here we propose a data-driven method for evaluating the potential impact of beam contaminants on physics analyses. The method exploits the time-dependence and smaller size of contaminant ion species to define control regions that can be used to quantify potential contamination effects. A simple mode

Accelerator Physics (physics.acc-ph)↗

Lunar atmosphere measurements.

Cold cathode ionization gauges were left on the lunar surface during Apollo missions 14 and 15 to measure the amount of lunar gas. The observed nighttime concentration is very low, about 200,000 per cu cm, which is less than the neon concentration that might be expected from the solar wind. This suggests that the lunar surface is not saturated with solar wind neon, and hence that less neon is being released from the surface than impinges upon it. The low nighttime concentration shows that contaminant gases from the Apollo operations freeze out at night or become adsorbed on the cold lunar surface. Observed daytime concentrations have been two orders of magnitude greater than the nighttime values and appear to be due mainly to contamination in the landing area. The rate at which the contamination is decreasing is characterized by a time constant of a few months. Gas clouds have been seen at times and these appear to have been released from Apollo hardware left on the lunar surface.

Johnson, F. S.↗

Study of spark chambers filled with various gas mixtures

The performance is reported of the four layer spark chamber filled with alcohol vapors at 45 torr, very pure neon at 1 to 4.6 atm and also filled with only very pure neon at 1 to 2.9 atm. The curves of particles recording efficiency vs. the delay time in the chamber pulse supply and the number of operations are given. This efficiency decreases with an increase in the delay time; any addition of alcohol vapors increases the drop in the efficiency with time. However, alcohol vapors improve the localization of tracks along which the particles move and make them three to four times as narrow compared to the tracks inside the chamber filled with very pure neon.

Akopyan, G. S.↗

Correlation of self-contamination experiments in orbit and scattering return flux calculations

Gaseous emissions from a spacecraft modify the orbital environment degrade the observations of distant radiation sources, and provide contamination fluxes induced by self-scattering and scattering with ambient particles. Experiments were carried out on the orbiting Atmospheric Explorer-D satellite (AE-D) to verify the calculated return fluxes of a neon source. Known rates of neon were emitted in the direction of the velocity on command to the Molecular Return Measurement Unit (MRMU). At 250 km, the neutral mass spectrometer indicated a total neon return flux of .0246 times the emitted flux. The calculated fraction was .0123, including .00354 for the ambient scatter and .00354 for the altitude independent self-scatter. The pressure gages indicated return pressure less than .000933Pa .000007 at altitudes from 161 to 210 km. The maximum return pressure for 161-km orbit was calculated as 7.3 x 10-7 including a self scattering contribution of .000024 Pa .000000018.

Scialdone, J. J.↗

Comparison of satellite self-contamination experiments and scattering return flux calculations

Gaseous emissions from a spacecraft modify the orbital environment and degrade the observations of distant radiation sources. These emissions also provide contamination fluxes induced by self-scattering and scattering with ambient particles. Experiments were carried out on the orbiting Atmosphere Explorer D satellite (AE-D) to verify the calculated return fluxes of a neon source. Known rates of neon were emitted in the direction of the velocity vector on command from the MRMU (molecular return measurement unit). At 250 km the neutral mass spectrometer indicated a total neon return flux of 0.0246 times the emitted flux. The calculated fraction was 0.0123, including 0.00914 for the ambient scatter and 0.00354 for the altitude-independent self-scatter. The pressure gages indicated pressures less than 7 microtorr at altitudes from 161 to 210 km. The maximum pressure for the 161-km orbit was calculated as 0.74 microtorr.

Scialdone, J. J.↗

Interstellar cloud material - Contribution to planetary atmospheres

A statistical analysis of the properties of dense interstellar clouds indicates that the solar system has encountered at least a dozen clouds of sufficient density to cause planets to accumulate nonnegligible amounts of some isotopes. The effect is most pronounced for neon. This mechanism could be responsible for much of the neon in Earth's atmosphere. For Mars, the predicted amount of neon added by cloud encounters greatly exceeds the present abundance.

Butler, D. M.↗

Solar and terrestrial noble gases in magnetospheric precipitation

Metal-foil collectors were installed on the external structure of Skylab to entrap precipitating magnetospheric particles. The foils were retrieved, and the entrapped helium, neon, and argon were isotopically analyzed in a high-resolution mass spectrometer. Solar and terrestrial helium and neon and terrestrial argon were detected. As expected, the isotopic composition of neon and argon in the high atmosphere was found to be strongly fractionated. Special techniques were used to estimate the initial particle energy of He-3. The measured He-3 flux is consistent with the assumption that precipitating solar He-3 is the major source of terrestrial He-3.

Lind, D. L.↗

Detection of the Ne III 36 micron forbidden line in the planetary nebula NGC 6543

The first observation of the Ne III 36.02 micron forbidden line in a planetary nebula, NGC 6543, is presented. Since the dominant form of neon in medium-excitation to high-excitation planetary nebulae is Ne III, the abundance of this ion is important in determining the total neon abundance. Use of the 36 micron line for an abundance determination has the advantage of insensitivity to temperature uncertainties. However, current atomic parameters lead to a Ne III abundance in NGC 6543 which is 4.5 times the cosmic neon abundance and 2.6 times the abundance from optical line studies. Although such a high abundance cannot be ruled out immediately, inaccuracies in the infrared level collision strengths are suspected because resonances were neglected in their calculation. The 36 micron line is also useful as a temperature probe when combined with the Ne III 3868-A forbidden line. When compared to Ne III 15.56 micron forbidden line fluxes, a temperature-insensitive density estimate may be obtained. The utility of these line ratios depends upon the actual infrared level collision strengths, which will affect the density range over which they are sensitive.

Shure, M. A.↗

Grain abundance in the primordial atmosphere of the earth

For models of planetary accumulation in the presence of solar nebular gas, the initial surface temperature of the earth is controlled by the grain opacity of the atmosphere. The surface temperature in turn controls the quantity of neon dissolved and trapped within the interior of the earth. To compare accumulation theory with observation, calculations have been made of the grain opacity expected to be associated with accumulation in a gaseous nebula. There are two parameters that are in principle determined by the theory, but actually are at present uncertain: the mean eccentricity(e) of the planetesimal swarm, and the fraction (xi) of the accretional energy that is expended in the release of grains into the atmosphere by ablation of the incoming planetesimal. It is found that if e is low (0.001), rather low values of xi (0.00001) are required to match the observed neon data. In contrast higher values of xi (0.1) are required for the most probable case with e = 0.01. For the high-eccentricity case (e = 0.1), xi must be greater than 0.01. The results show that avoidance of excess trapped neon of solar composition places restrictive, but not necessarily impossible, conditions on the parameters of the accumulation theory.

Mizuno, H.↗

Ionization Chamber Measures Extreme Ultraviolet

Ionization chamber operates in nearly total photon absorption as stable, self-calibrating detector of ionizing extreme ultraviolet radiation. Working gas of instrument is neon; photoionization properties well known and readily applicable to absolute measurements. Designed for measurements of solar ultraviolet flux aboard sounding rocket, instrument used on Earth to measure ultraviolet radiation in vacuum systems. Ionization chamber collects positive neon ions and electrons produced by irradiation of neon gas by ultraviolet photons. Approximately one ion produced by each photon; consequently, photoionization current nearly proportional to photon flux.

Carlson, Robert W.↗

Solar, planetary, and other inert gases in two sieve fractions of a disaggregated Allende sample - A study by stepwise heating extraction

Inert gases released by stepwise heating of unaltered, strongly magnetic, and weakly magnetic samples from the 0-64 micron and the 105-250 micron fractions of a disaggregated and sieved sample of the Allende meteorite reveal the occurrence of both solar and planetary neon. The origin of the solar neon is thought to be implantation of solar wind ions. The origin of the planetary neon remains unresolved. Heavy isotope enriched components of krypton and xenon have been detected and there are some indications that a light krypton component may also be present. Other than a larger concentration of Xe-129 in the weakly magnetic samples, the signatures of the magnetic separates are isotopically very similar.

Palma, R. L.↗

One dimensional heavy ion beam transport: Energy independent model

Attempts are made to model the transport problem for heavy ion beams in various targets, employing the current level of understanding of the physics of high-charge and energy (HZE) particle interaction with matter are made. An energy independent transport model, with the most simplified assumptions and proper parameters is presented. The first and essential assumption in this case (energy independent transport) is the high energy characterization of the incident beam. The energy independent equation is solved and application is made to high energy neon (NE-20) and iron (FE-56) beams in water. The numerical solutions is given and compared to a numerical solution to determine the accuracy of the model. The lower limit energy for neon and iron to be high energy beams is calculated due to Barkas and Burger theory by LBLFRG computer program. The calculated values in the density range of interest (50 g/sq cm) of water are: 833.43 MeV/nuc for neon and 1597.68 MeV/nuc for iron. The analytical solutions of the energy independent transport equation gives the flux of different collision terms. The fluxes of individual collision terms are given and the total fluxes are shown in graphs relative to different thicknesses of water. The values for fluxes are calculated by the ANASTP computer code.

Farhat, Hamidullah↗