Quantitative Rainbow Schlieren Deflectometry as a Temperature Diagnostic for Spherical Flames
Numerical analysis and experimental results are presented to define a method for quantitatively measuring the temperature distribution of a spherical diffusion flame using Rainbow Schlieren Deflectometry in microgravity. First, a numerical analysis is completed to show the method can suitably determine temperature in the presence of spatially varying species composition. Also, a numerical forward-backward inversion calculation is presented to illustrate the types of calculations and deflections to be encountered. Lastly, a normal gravity demonstration of temperature measurement in an axisymmetric laminar, diffusion flame using Rainbow Schlieren deflectometry is presented. The method employed in this paper illustrates the necessary steps for the preliminary design of a Schlieren system. The largest deflections for the normal gravity flame considered in this paper are 7.4 x 10(-4) radians which can be accurately measured with 2 meter focal length collimating and decollimating optics. The experimental uncertainty of deflection is less than 5 x 10(-5) radians.