259 records · Page 15

Lunar Glovebox Balance with Wireless Technology

The most important equipment required for processing lunar samples is a high-quality mass balance for maintaining accurate weight inventory, security, and scientific study. After careful review, a Curation Office memo by Michael Duke in 1978 chose the Mettler PL200 to be used for sample weight measurements inside the gloveboxes (Fig. 3). These commercial off-the-shelf (COTS) balances did not meet the strict accepted material requirements in the Lunar lab. As a result, each balance housing, weighing pan, and wiring was custom retrofitted to meet Lunar Operating Procedure (LOP) 54 requirements [for material construction restrictions]. The original design drawings for the custom housings, readout support stands, and wiring were done by the JSC engineering directorate. The 1977- 1978 schematics, drawings, and files are now housed in the curation Data Center. Per the design specifications, the housing was fabricated from aluminum grade 6061 T6, seamless welds, and anodized per MIL-A-8625 type I, class I. The balance feet were TFE Teflon and any required joints were sealed with Viton A gaskets. The readout display and support stands outside the glovebox were fabricated from 300 series stainless steel with #4 finish and mounted to the glovebox with welded bolts. Wire harnesses that linked the balance with the outside display and power were encapsulated with TFE Teflon and transported through custom Deutsch wire bulk head pass-through systems from inside to outside the glovebox. These Deutsch connectors were custom fabricated with 316L stainless steel bodies, Viton A O-rings, aluminum 6061 with electroless nickel plating, Teflon (replacing the silicone), and gold crimp connectors (no soldering). Many of the Deutsch connectors may have been used in the Apollo program high vacuum complex in building 37 and date to about 1968 to 1970.

Zeigler, Ryan A.↗

Electrodynamic Dust Shield Housing for RASSOR Redesign and Fabrication

Abstract—An Electrodynamic Dust Shield (EDS) was to be mounted over the cameras of the Regolith Advanced Surface Systems Operations Robot (RASSOR) to mitigate the clouding effects and abrasive properties of lunar dust. This report discusses the redesign process and physical fabrication of the housing unit planned to attach the EDS to the RASSOR camera. The two-piece 3D-Printed design consists of a holder and cover unit. The EDS Holder seats the EDS near two live copper contacts that are to be wired into the main electronics housing. The EDS Cover seats two metal leaf spring tabs to bridge the connections between the copper contacts and EDS electrodes, as well as a centralized O-ring that is pressed flush against the EDS to mitigate dust intrusion. All components were modeled, printed, and checked for proper electrical contact and mechanical fit. The built-up assembly was subsequently tested in the Electrostatics and Surface Physics Laboratory (ESPL) and demonstrated good dust clearing performance.

Alexander Lacerna↗

The Challenger Tradgedy was Caused by an Apollo Mistake, Terminating Risk Analysis

NASA’s attitude toward risk changed drastically between the Apollo and Space Shuttle design. [1]Apollo engineers were seriously alarmed about riskbecause of the fatal Apollo 1 fire and the fact that the estimated probability of another fatal accident was extremely high. The predictions were so appalling thatmanagement terminated risk analysis to avoid public apprehension. Because risk analysis was not done, the Space Shuttle design accepted excessively high andunknown risk. The immediate cause of the Challengertragedy was the mistaken decision to launch in coldweather that impaired the O-ring seals, but the fundamental cause was the high risk of the shuttle design. Before Challenger, management asserted that the probability of a fatal accident was 1 in 100,000.Probabilistic Risk Analysis (PRA) found a roughly 1 in 100 chance of a shuttle failure.

Harry W Jones↗

Passive Water Assurance Delivery System

This report provides an analysis and evaluation of proposed design improvements to the internal water delivery system of NASA’s passive vegetable growing system. The VEGGIE system is designed to provide fresh vegetables and psychological benefits for astronauts aboard the International Space Station. Preliminary testing conducted by NASA for the VEGGIE system revealed flaws in the water delivery system. In these tests, the interface between the plants and the water reservoir failed to provide passive water delivery through the system both in microgravity experiments and experiments conducted on Earth. Our team’s goal was to fix this interface such that water can be passively delivered from the water reservoir to the plant rooting pillows to grow vegetative crops from seed to harvest. The system requirements outlined by NASA include: minimal total mass, on-demand passive water delivery, same dimensions as existing fixtures, minimal pressure on system to prevent leaking, zero mold growth, minimal swelling or clogging for non-flammable capillary materials, pressure stabilization between the water reservoir and plant pillow bags, even dispersal of water during initial priming, minimal bubble obstruction of capillary interface, maximum gas availability to plant roots, growth in a mixed artificial media (50:50 Arcillite:Fafard #2), and to avoid overwatering and drought conditions for plants. The major proposed design improvements are to use a single-interface capillary cord design to directly connect the water reservoir to the plant-rooting pillows, and to alter the water reservoir to model a propellant management device (PMD) in order to ensure consistent and long term watering for the VEGGIE system. The plant rooting pillow required minimal changes outside of replacing the capillary mat on the bottom of the pillow with O-ring insertion points the single-interface capillary system. - Research was conducted to determine which materials are able to uptake water through capillary action to grow Outredgeous Lettuce plants from seed to harvest. The primary requirements to be met by the team's design and evaluation of the capillary interface were: continuous passive watering for 90 days using non-flammable capillary materials and a peak water delivery rate of 30 mL/hr./0.15 m 2 . The results of the team's experimentation showed that the capillary material Nomex displayed the highest capillary water delivery potential with a maximum flow rate of 3.6 mL/hr. The Nomex capillary systems were the only capillary material to consistently grow Outredgeous Lettuce plants from seed to harvest, and displayed the highest average flow rate for multiple experiment sets. The Nomex material was previously incorporated into the VEGGIE system using a matted version of the capillary material, though the team recommends using a cord configuration in the single-interface capillary system for greater system stability. Nomex has proven to be a promising material, as it has passed both health and fire standards for use aboard the International Space Station. PMDs are made of materials that utilize surface tension and adhesive forces to overcome adverse accelerations to improve stability and ensure fluid delivery. PMDs are typically used in fuel tanks to ensure fuel delivery. The team recommends using a sponge PMD in order to mitigate bubble obstruction, decrease system weight, and ensure reliable water delivery to the capillary interface. The PMD water reservoir requires a rigid water reservoir and a vent tube for pressure stabilization. Since PMD’s cannot be tested in 1-G (Earth conditions), further theoretical modeling and testing is required for the proposed water reservoir design. The intent of this proposed system is to passively water plants in microgravity, though the technology is not limited to microgravity applications. The testing at The Ohio State University has proven that the design is highly effective on Earth, demonstrating that it could serve as a simple water delivery system in home and office applications. This would make vegetative crops more accessible in all indoor applications, thereby improving indoor air quality and occupant comfort. Additionally, this technology has great potential to be utilized in greenhouse plant production, cutting back on more sophisticated watering system energy and time requirements.

Alexandria Jensen↗

Accelerated Aging and Evaluation of Hose-In-Hose Transfer Lines in the Hanford Waste Transfer System - 20312

Nonmetallic materials are used in the United States Department of Energy's Hanford Site Tank Farm waste transfer system. These materials include the inner primary hoses in the hose-in-hose transfer lines (HIHTLs), Garlock{sup R} gaskets, ethylene propylene diene monomer (EPDM) O-rings, and other nonmetallic materials. These nonmetallic materials are exposed to β and γ radiation, caustic solutions as well as high temperature and pressure stressors. How the nonmetallic components react to each of these stressors individually has been well established. However, simultaneous exposure of these stressors has not been evaluated and is of great concern to Hanford Site engineers. Florida International University's Applied Research Center engineers worked closely with key Hanford's Washington River Protection Solutions personnel to develop an experimental test plan that determines how these nonmetallic components react to various simultaneous stressor exposures. In this paper, research on the experimental testing of the hose-in-hose transfer lines used in the Hanford tank farm waste transfer system under simultaneous stressor exposures is presented. The stressor exposure experiments consisted of various combinations of simultaneous stressor exposure of caustic solution, high temperature and high pressure stressors. Research efforts focused on evaluating the aging behavior of EPDM by exposing samples of HIHTLs as well as EPDM dog bone shaped specimens to a 25% NaOH solution at (38 deg. C), operating (54 deg. C) and design temperatures (77 deg. C) for 6 months and 12 months. In addition, HIHTL and the EPDM dog-bone specimens were exposed to only hot water at 77 deg. C for a duration of one year. The mechanical and material properties of the samples were characterized and compared with those of the unexposed samples (baseline). Evaluations included burst pressure tests of the EPDM hose-in-hose transfer lines and material tensile strength test of EPDM dog-bone coupons. Both the tensile strength of the EPDM material dog bones and the burst pressure of the HIHTLs significantly decreased with the increasing temperature and increasing exposure time. When compared with the baseline samples, the burst pressure decreased by 28.75% for the sample aged at 77 deg. C after 12 months, in comparison to sample aged at 38 deg. C and 54 deg. C which had about 1.34% and 5.70% loss in burst pressures, respectively, after 12-month exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NASA Engineering and Safety Center Technical Bulletins 2007-2023

An NESC Technical Bulletin captures critical knowledge in the form of new engineering information or best practices in a one-page format that have resulted from NESC independent testing, analysis, and assessments. This document contains all NESC Technical Bulletins from 2007 through 2023.

additive manufacturing, battery, braycote, capacit↗