A versatile high-average-power ultrafast infrared driver tailored for high-harmonic generation and vibrational spectroscopy

We report on an ultrafast infrared optical parametric chirped-pulse amplifier (OPCPA), pumped by a 200-W thin-disk Yb-based regenerative amplifier at a repetition rate of 100 kHz. The OPCPA is tunable in the spectral range 1.4–3.9 μm, generating up to 23 W of < 100-fs signal and 13 W of < 200-fs idler pulses for infrared spectroscopy, with additional spectral filtering capabilities for Raman spectroscopy. The OPCPA can also yield 19 W of 49-fs 1.75- μm signal or 5 W of 62-fs 2.8- μm idler pulses with active carrier-to-envelope-phase (CEP) stabilisation for high-harmonic generation (HHG). We illustrate the versatility of the laser design, catering to various experimental requirements for probing ultrafast science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aerosol Microphysics and Chemical Measurements at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024 UCSD Library Collection

This dataset includes guest instrument measurements and other PI products for aerosol microphysics and chemical measurements collected at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024. The measurements include the following instruments at Mt. Soledad: High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS, Aerodyne), Scanning Electrical Mobility Spectrometer (SEMS, Brechtel Manufacturing Inc.), Aerodynamic Particle Sizer (APS, Droplet Measurements Technologies), Single Particle Soot Photometer (SP2, Drople Measurements Technologies), Meteorological Station (WXT520, Vaisala), Ozone (Teco), and trace gas proxies (Teledyne). In addition, the analyses of particle filters collected at Mt. Soledad for three dry-diameter size cuts (<1 micron, <0.5 micron, <0.18 micron) and at Scripps Pier for one dry-diameter size cut (<1 micron) by Fourier Transform Infrared (FTIR) and X-ray Fluorescence (XRF) are reported. A differential mobility analyzer operated as a scanning mobility particle sizer (SMPS, TSI Inc.), a printed particle optical spectrometer (POPS, Grimm), and a continuous flow diffusion cloud condensation nuclei (CCN, DMT) counter provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. Measurements are reported for both sampling from an isokinetic aerosol inlet and from a Counterflow Virtual Impactor (CVI, Brechtel Manufacturing Inc.). The data are available at the following link: https://library.ucsd.edu/dc/collection/bb0898306q

54 ENVIRONMENTAL SCIENCES↗

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

Design and validation of a nanosecond short-wave infrared streak camera using gaseous detonation experiments

A custom short-wave infrared (SWIR) galvanometric streak camera was developed to provide nanosecond- scale, time-resolved optical diagnostics. The system was designed as a compact, mechanically driven alternative to traditional tube-based streak cameras, using a galvanometer mirror and multiple-reflection optical path to achieve high temporal resolution while maintaining electronic synchronization for trigger sequencing. Temporal resolution achieved 139.5 ns/px, allowing direct conversion of image-slope gradients to physical wave velocities. The instrument was validated using hydrogen-oxygen-argon detonations within a modular detonation tube, capturing transient emission structures and post-detonation decay behavior with microsecond precision. Although signal levels in filtered configurations were limited by lens transmission and detector sensitivity, the system successfully resolved intensity rise and decay characteristics across 10-60 % argon mixtures. The observed trends demonstrate the feasibility of compact galvanometer-based streak systems for high-speed SWIR imaging in reactive environments!

42 ENGINEERING↗

Deep drilling in the time domain with DECam: survey characterization

ABSTRACT This paper presents a new optical imaging survey of four deep drilling fields (DDFs), two Galactic and two extragalactic, with the Dark Energy Camera (DECam) on the 4-m Blanco telescope at the Cerro Tololo Inter-American Observatory (CTIO). During the first year of observations in 2021, >4000 images covering 21 deg2 (seven DECam pointings), with ∼40 epochs (nights) per field and 5 to 6 images per night per filter in g, r, i, and/or z have become publicly available (the proprietary period for this program is waived). We describe the real-time difference-image pipeline and how alerts are distributed to brokers via the same distribution system as the Zwicky Transient Facility (ZTF). In this paper, we focus on the two extragalactic deep fields (COSMOS and ELAIS-S1) characterizing the detected sources, and demonstrating that the survey design is effective for probing the discovery space of faint and fast variable and transient sources. We describe and make publicly available 4413 calibrated light curves based on difference-image detection photometry of transients and variables in the extragalactic fields. We also present preliminary scientific analysis regarding the Solar system small bodies, stellar flares and variables, Galactic anomaly detection, fast-rising transients and variables, supernovae, and active Galactic nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

New application of hyperspectral imaging to steady-state plasma observations

A new application of hyperspectral imaging (HSI) to steady-state plasma emission observations is proposed because of its prominent feature: an HSI camera records a two-dimensional image, and each spatial pixel contains spectral data typically with more than a hundred bands, while conventional digital cameras have only three bands. The characterization of an HSI camera (Specim IQ) has been performed during steady-state plasma–material interaction experiments using the linear plasma device PISCES-A. By easily subtracting the background/continuum emission in contrast to conventional filter cameras, two-dimensional images of multiple emission lines at different wavelengths are simultaneously obtained during a single measurement, demonstrating the advantage in plasma emission observations.

47 OTHER INSTRUMENTATION↗

Predicting 3D Motions from Single-Camera Optical Test Data

In a typical optical test, a stereo camera pair is required to measure the three-dimensional motion of a test article; one camera typically only measures motions in the image plane of the camera, and measurements in the out-of-plane direction are missing. Finite element expansion techniques provide a path to estimate responses from a test at unmeasured degrees of freedom. Treating the case of a single camera as a measurement with unmeasured degrees of freedom, a finite element model is used to expand to the missing third dimension of the image data, allowing a full-field, three-dimensional measurement to be obtained from a set of images from a single camera. The key to this technique relies on the mapping of finite element deformations to image deformations, creating a set of mode shape images that are used to filter the response in the image into modal responses. These modal responses are then applied to the finite element model to estimate physical responses at all finite element model degrees of freedom. The mapping from finite element model to image is achieved using synthetic images produced by a rendering software. Finally, the technique is applied first to a synthetic deformation image, and then is validated using an experimental set of images.

47 OTHER INSTRUMENTATION↗

Quantum interferometry and pathway selectivity in the nonlinear response of photosynthetic excitons

We propose a time–frequency resolved spectroscopic technique which employs nonlinear interferometers to study exciton–exciton scattering in molecular aggregates. A higher degree of control over the contributing Liouville pathways is obtained as compared to classical light. We show how the nonlinear response can be isolated from the orders-of-magnitude stronger linear background by either phase matching or polarization filtering. Both arise due to averaging the signal over a large number of noninteracting, randomly oriented molecules. We apply our technique to the Frenkel exciton model which excludes charge separation for the photosystem II reaction center. We show how the sum of the entangled photon frequencies can be used to select two-exciton resonances, while their delay times reveal the single-exciton levels involved in the optical process.

Science & Technology - Other Topics↗

Room temperature valley polarization via spin selective charge transfer

Abstract The two degenerate valleys in transition metal dichalcogenides can be used to store and process information for quantum information science and technology. A major challenge is maintaining valley polarization at room temperature where phonon-induced intervalley scattering is prominent. Here we demonstrate room temperature valley polarization in heterostructures of monolayer MoS 2 and naphthylethylammine based one-dimensional chiral lead halide perovskite. By optically exciting the heterostructures with linearly polarized light close to resonance and measuring the helicity resolved photoluminescence, we obtain a degree of polarization of up to −7% and 8% in MoS 2 /right-handed (R-(+)-) and left-handed (S-(-)-) 1-(1-naphthyl)ethylammonium lead iodide perovskite, respectively. We attribute this to spin selective charge transfer from MoS 2 to the chiral perovskites, where the perovskites act as a spin filter due to their chiral nature. Our study provides a simple, yet robust route to obtain room temperature valley polarization, paving the way for practical valleytronics devices.

36 MATERIALS SCIENCE↗

Temporal reflection from short pump pulses inside a dispersive nonlinear medium: the impact of pump parameters

We have studied, through a series of experiments and numerical simulations, how temporal reflection from an intense pump pulse inside a photonic crystal fiber is affected by parameters of the pump pulse used to form a moving high-index boundary. We used femtosecond pump pulses, which slow down inside the fiber as their spectrum red-shifts because of intrapulse Raman scattering. Temporal reflection of probe pulses occurs from such decelerating pump pulses. We changed the width and chirp of our pump pulses with a 4f pulse shaper capable of providing both spectral filtering and frequency chirping. We found that temporal refection exhibited novel features, to our knowledge, when pump pulses were made wider or chirped. In both cases, two or more reflected pulses were produced at different wavelengths in a specific range of the initial pump-probe delays. Furthermore, numerical simulations reveal that the origin of such novel features is related to the complex nonlinear evolution of pump pulses inside optical fibers.

47 OTHER INSTRUMENTATION↗

Quantum teleportation coexisting with classical communications in optical fiber

The ability for quantum and conventional networks to operate in the same optical fibers would aid the deployment of quantum network technology on a large scale. Quantum teleportation is a fundamental operation in quantum networking, but has yet to be demonstrated in fibers populated with high-power conventional optical signals. Here we report, to the best of our knowledge, the first demonstration of quantum teleportation over fibers carrying conventional telecommunications traffic. Quantum state transfer is achieved over a 30.2-km fiber carrying 400-Gbps C-band classical traffic with a Bell state measurement performed at the fiber’s midpoint. To protect quantum fidelity from spontaneous Raman scattering noise, we use optimal O-band quantum channels, narrow spectro-temporal filtering, and multi-photon coincidence detection. Fidelity is shown to be well maintained with an elevated C-band launch power of 18.7 dBm for the single-channel 400-Gbps signal, which we project could support multiple classical channels totaling many terabits/s aggregate data rates. These results show the feasibility of advanced quantum and classical network applications operating within a unified fiber infrastructure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

KIPM Detector Characterization in QUIET

Kinetic Inductance Phonon‑Mediated (KIPM) detectors are superconducting microwave resonators on silicon that sense bursts of energy through tiny shifts in their resonance. In this work, we installed new devices in the QUIET facility's cryogenic test setup and used a network analyzer to drive them across a range of power levels. At each setting, we measured the transmitted signal and fit it to a simple notch‑filter model, allowing us to extract key performance metrics. And despite the increased noise at low power, our model consistently captured the resonance behavior. We observed that the resonant frequency stayed stable across most powers, the device s internal quality factor improved with stronger signals, and its coupling strength peaked mid‑range before leveling off. Overall, these findings confirm the detector s performance, laying groundwork for future work on energy calibration with pulsed optical sources.

Savitala, Akash [Washington U., Seattle; Fermilab]↗

Characterizing x-ray transmission through filters used in high energy density physics diagnostics

We report on the design and implementation of a new system used to characterize the energy-dependent x-ray transmission curve, Θ(E), through filters used in high-energy density physics diagnostics. Using an Amptek X-123-CdTe x-ray spectrometer together with a partially depleted silicon surface barrier detector, both the energy spectrum and total emission of an x-ray source have been accurately measured. By coupling these detectors with a custom PROTO-XRD x-ray source with interchangeable cathodes, accurate characterizations of Θ(E) for filters of varying materials and thicknesses have been obtained. The validity of the technique has been confirmed by accurately reproducing areal densities for high-purity filters with known x-ray transmission properties. In this paper, the experimental setup is described and the results of absorption calibrations performed on a variety of different filters are presented.

47 OTHER INSTRUMENTATION↗

Topographic hydro-conditioning to resolve surface depression storage and ponding in a fully distributed hydrologic model

Land surface depressions play a central role in the transformation of rainfall to ponding, infiltration and runoff, yet digital elevation models (DEMs) used by spatially distributed hydrologic models that resolve land surface processes rarely capture land surface depressions at spatial scales relevant to this transformation. Methods to generate DEMs through processing of remote sensing data, such as optical and light detection and ranging (LiDAR) have favored surfaces without depressions to avoid adverse slopes that are problematic for many hydrologic routing methods. Here, in this study, we present a new topographic conditioning workflow, Depression-Preserved DEM Processing (D2P) algorithm, which is designed to preserve physically meaningful surface depressions for depression-integrated and efficient hydrologic modeling. D2P includes several features: (1) an adaptive screening interval for delineation of depressions, (2) the ability to filter out anthropogenic land surface features (e.g., bridges), (3) the ability to blend river smoothing (e.g., a general downslope profile) and depression resolving functionality. From a case study in the Goodwin Creek Experimental Watershed, D2P successfully resolved 86% of the ponds at a DEM resolution of 10 m. Topographic conditioning was achieved with minimum impact as D2P reduced the number of modified cells from the original DEM by 51% compared to a conventional algorithm. Furthermore, hydrologic simulation using a D2P processed DEM resulted in a more robust characterization on surface water dynamics based on higher surface water storage as well as an attenuated and delayed peak streamflow.

54 ENVIRONMENTAL SCIENCES↗

On-chip spectrometers using stratified waveguide filters

We present an ultra-compact single-shot spectrometer on silicon platform for sparse spectrum reconstruction. It consists of 32 stratified waveguide filters (SWFs) with diverse transmission spectra for sampling the unknown spectrum of the input signal and a specially designed ultra-compact structure for splitting the incident signal into those 32 filters with low power imbalance. Each SWF has a footprint less than 1 µm × 30,µm, while the 1 × 32 splitter and 32 filters in total occupy an area of about 35 µm × 260 µm, which to the best of our knowledge, is the smallest footprint spectrometer realized on silicon photonic platform. Experimental characteristics of the fabricated spectrometer demonstrate a broad operating bandwidth of 180 nm centered at 1550 nm and narrowband peaks with 0.45 nm Full-Width-Half-Maximum (FWHM) can be clearly resolved. This concept can also be implemented using other material platforms for operation in optical spectral bands of interest for various applications.

42 ENGINEERING↗

COOL-LAMPS. VII. Quantifying Strong-lens Scaling Relations with 177 Cluster-scale Strong Gravitational Lenses in DECaLS

Abstract We estimate the Einstein-radius-enclosed total mass for 177 cluster-scale strong gravitational lenses identified by the ChicagO Optically selected Lenses Located At the Margins of Public Surveys (COOL-LAMPS) collaboration with lens redshifts ranging from 0.2 ⪅ z ⪅ 1.0 using the brightest-cluster-galaxy (BCG) redshift and an observable proxy for the Einstein radius. We constrain the Einstein-radius-enclosed luminosity and stellar mass by fitting parametric spectral energy distributions to aperture photometry from the Dark Energy Camera Legacy Survey (DECaLS) in the g -, r -, and z -band Dark Energy Camera filters. We find that the BCG redshift, enclosed total mass, and enclosed luminosity are strongly correlated and well described by a planar relationship in 3D space. We find that the enclosed total mass and stellar mass are correlated with a logarithmic slope of 0.50 0 − 0.031 + 0.029 , and the enclosed total mass and stellar-to-total mass fraction are correlated with a logarithmic slope of − 0.49 5 − 0.033 + 0.032 . In tandem with the small radii within which these slopes are constrained, this may suggest invariance in baryon conversion efficiency and feedback strength as a function of cluster-centric radii in galaxy clusters. Additionally, the correlations described here should have utility in ranking strong-lensing candidates in upcoming imaging surveys—such as Rubin/Legacy Survey of Space and Time—in which an algorithmic treatment of strong lenses will be needed due to the sheer volume of data these surveys will produce.

Mork, Simon D. (ORCID:0000000255739131)↗

Hyperdimensional Imaging Contrast Using an Optical Fiber

Fluorescence properties of a molecule can be used to study the structural and functional nature of biological processes. Physical properties, including fluorescence lifetime, emission spectrum, emission polarization, and others, help researchers probe a molecule, produce desired effects, and infer causes and consequences. Correlative imaging techniques such as hyperdimensional imaging microscopy (HDIM) combine the physical properties and biochemical states of a fluorophore. Here we present a fiber-based imaging system that can generate hyper-dimensional contrast by combining multiple fluorescence properties into a single fluorescence lifetime decay curve. Fluorescence lifetime imaging microscopy (FLIM) with controlled excitation polarization and temporally dispersed emission can generate a spectrally coded, polarization-filtered lifetime distribution for a pixel. This HDIM scheme generates a better contrast between different molecules than that from individual techniques. This setup uses only a single detector and is simpler to implement, modular, cost-efficient, and adaptable to any existing FLIM microscope. We present higher contrast data from Arabidopsis thaliana epidermal cells based on intrinsic anthocyanin emission properties under multiphoton excitation. This work lays the foundation for an alternative hyperdimensional imaging system and demonstrates that contrast-based imaging is useful to study cellular heterogeneity in biological samples.

47 OTHER INSTRUMENTATION↗

Semiconductor-dielectric-metal solar absorbers with high spectral selectivity

An ideal solar thermal absorber has a sharp transition between high and low absorptance at the wavelength where the blackbody emissive power begins to exceed the solar irradiance. However, most real selective absorbers have a fairly broad transition, leading to both solar absorption and thermal emission losses. Here, we model, fabricate, and characterize a highly selective semiconductor-dielectric-metal (Ga0.46In0.54As - MgF2 - Ag) solar absorber with an extremely sharp transition from high to low absorptance. The thin semiconductor serves as a selective filter, absorbing photons with wavelengths shorter than the bandgap and transmitting those with longer wavelengths. The highly reflective dielectric-metal rear mirror allows the structure to have very low emittance for longer wavelengths. These characteristics provide the absorber with a measured solar absorptance >91% below the bandgap wavelength and infrared emittance <5% at 100 degrees C above the bandgap wavelength. This transition wavelength can be tuned by modifying the semiconductor composition, and modeling indicates that the absorber's optical properties should be stable at high temperatures, making the structure a good candidate for unconcentrated to highly concentrated solar thermal energy conversion.