Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Integrated-Optic Oxygen Sensors

Compact optical oxygen sensors with self-calibration capabilities are undergoing development. A sensor of this type features a single-chip, integrated-optic design implemented by photolithographic fabrication of optical waveguides in a photosensitive porous glass. The porosity serves as both a matrix for retention of an oxygen-sensitive fluorescent indicator chemical and a medium for diffusion of oxygen to the chemical from the ambient air to be monitored. Each sensor includes at least one such waveguide exposed to the atmosphere and at least one covered with metal for isolation from the atmosphere. The covered one serves as a reference channel. In operation, the concentration of oxygen is deduced from the intensity and lifetime of the fluorescence in the exposed channel, with the help of calibration data acquired via the reference channel. Because the sensory chemical is placed directly in and throughout the cross section of the light path, approximately 99 percent of the light in the waveguide is available for interaction with the chemical, in contradistinction to only about 1 percent of the light in an optical sensor that utilizes evanescentwave coupling. Hence, a sensor of this type is significantly more sensitive.

Mendoza, Edgar A.↗

Optical calculation of correlation filters

A method is presented for designing optical correlation filters based on measuring intensity patterns in the Fourier plane. The method can be used in general to design any type of frequency plane filter but is especially attractive in the case of a binary phase only filter (BPOF). The method can produce a filter that is well matched to both the object, its transforming optical system and the spatial light modulator used in the correlator input plane. A working filter was produced using the technique, but the filter response was weak. The suspected causes of the weak output are imprecise Fourier plane positioning, nonlinearities in the recording process, and/or aliasing effects.

Knopp, Jerome↗

Analysis of a spatial tracking subsystem for optical communications

Spatial tracking plays a very critical role in designing optical communication systems because of the small angular beamwidth associated with the optical signal. One possible solution for spatial tracking is to use a nutating mirror which dithers the incoming beam at a rate much higher than the mechanical disturbances. A power detector then senses the change in detected power as the signal is reflected off the nutating mirror. This signal is then correlated with the nutator driver signals to obtain estimates of the azimuth and elevation tracking signals to control the fast scanning mirrors. A theoretical analysis is performed for a spatial tracking system using a nutator disturbed by shot noise and mechanical vibrations. Contributions of shot noise and mechanical vibrations to the total tracking error variance are derived. Given the vibration spectrum and the expected signal power, there exists an optimal amplitude for the nutation which optimizes the receiver performance. The expected performance of a nutator based system is estimated based on the choice of nutation amplitude.

Win, Moe Z.↗

Portable Inspection

The portable SpectroReflectometer, an instrument developed by AZ Technology, Inc. in partnership with NASA's Kennedy Space Center is now being manufactured and sold as a cost-effective solution to the development of scientific space flight hardware. This technology originated with the efforts to determine the degradation mechanisms of the space environment on space craft materials. AZ Technology's mission is to provide high quality products and services in electro-mechanical-optical design and hardware integration, advanced thermal and optical coatings and materials, and in the development of custom hardware systems for scientific measurements.

Source record↗

Intelligent Optical Systems Using Adaptive Optics

Until recently, the phrase adaptive optics generally conjured images of large deformable mirrors being integrated into telescopes to compensate for atmospheric turbulence. However, the development of smaller, cheaper devices has sparked interest for other aerospace and commercial applications. Variable focal length lenses, liquid crystal spatial light modulators, tunable filters, phase compensators, polarization compensation, and deformable mirrors are becoming increasingly useful for other imaging applications including guidance navigation and control (GNC), coronagraphs, foveated imaging, situational awareness, autonomous rendezvous and docking, non-mechanical zoom, phase diversity, and enhanced multi-spectral imaging. The active components presented here allow flexibility in the optical design, increasing performance. In addition, the intelligent optical systems presented offer advantages in size and weight and radiation tolerance.

Clark, Natalie↗

Micro-Spec: An Ultra-Compact, High-Sensitivity Spectrometer for Far-Infrared and Sub-Millimeter Astronomy

High-performance, integrated spectrometers operating in the far-infrared and sub-millimeter promise to be powerful tools for the exploration of the epochs of reionization and initial galaxy formation. These devices, using high-efficiency superconducting transmission lines, can achieve the performance of a meter-scale grating spectrometer in an instrument implemented on a four-inch silicon wafer. Such a device, when combined with a cryogenic telescope in space, provides an enabling capability for studies of the early universe. Here, the optical design process for Micro-Spec (mu-Spec) is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the stigmatization and minimization of the light path function in this bounded region, which results in an optimized geometrical configuration. A point design with an efficiency of approx. 90% has been developed for initial demonstration, and can serve as the basis for future instruments. Design variations on this implementation are also discussed, which can lead to lower efficiencies due to diffractive losses in the multimode region.

spectroscopic instrumentation↗

Designing Eccentric Aperture Optical Systems

Computer program aids in design of eccentric aperture optical systems by predicting vector aberration that occurs in optical system having tilted or decentered optical elements. Computer program incorporates vector theory of aberrations.

Rogers, J. R.↗

Free-space laser communication technologies III; Proceedings of the Meeting, Los Angeles, CA, Jan. 21, 22, 1991

The present volume on free-space laser communication technologies discusses system analysis, performance, and applications, pointing, acquisition, and tracking in beam control, laboratory demonstration systems, and transmitter and critical component technologies. Attention is given to a space station laser communication transceiver, meeting intersatellite links mission requirements by an adequate optical terminal design, an optical approach to proximity-operations communications for Space Station Freedom, and optical space-to-ground link availability assessment and diversity requirements. Topics addressed include nonmechanical steering of laser beams by multiple aperture antennas, a free-space simulator for laser transmission, heterodyne acquisition and tracking in a free-space diode laser link, and laser terminal attitude determination via autonomous star tracking. Also discussed are stability considerations in relay lens design for optical communications, liquid crystals for lasercom applications, and narrowband optical interference filters.

Begley, David L.↗

Laboratory Testing and Performance Verification of the CHARIS Integral Field Spectrograph

The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an integral field spectrograph (IFS) that has been built for the Subaru telescope. CHARIS has two imaging modes; the high-resolution mode is R82, R69, and R82 in J, H, and K bands respectively while the low-resolution discovery mode uses a second low-resolution prism with R19 spanning 1.15-2.37 microns (J+H+K bands). The discovery mode is meant to augment the low inner working angle of the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) adaptive optics system, which feeds CHARIS a coronagraphic image. The goal is to detect and characterize brown dwarfs and hot Jovian planets down to contrasts five orders of magnitude dimmer than their parent star at an inner working angle as low as 80 milliarcseconds. CHARIS constrains spectral crosstalk through several key aspects of the optical design. Additionally, the repeatability of alignment of certain optical components is critical to the calibrations required for the data pipeline. Specifically the relative alignment of the lens let array, prism, and detector must be highly stable and repeatable between imaging modes. We report on the measured repeatability and stability of these mechanisms, measurements of spectral crosstalk in the instrument, and the propagation of these errors through the data pipeline. Another key design feature of CHARIS is the prism, which pairs Barium Fluoride with Ohara L-BBH2 high index glass. The dispersion of the prism is significantly more uniform than other glass choices, and the CHARIS prisms represent the first NIR astronomical instrument that uses L-BBH2as the high index material. This material choice was key to the utility of the discovery mode, so significant efforts were put into cryogenic characterization of the material. The final performance of the prism assemblies in their operating environment is described in detail. The spectrograph is going through final alignment, cryogenic cycling, and is being delivered to the Subaru telescope in April 2016. This paper is a report on the laboratory performance of the spectrograph, and its current status in the commissioning process so that observers will better understand the instrument capabilities. We will also discuss the lessons learned during the testing process and their impact on future high-contrast imaging spectrographs for wavefront control.

Coronagraphic High Angular Resolution Imaging Spec↗

OSA Spotlight Summary: Designing Miniature X-ray Optics for the SmallSat Lunar Science Mission Concept CubeX

The scientific demand for extended field X-Ray remote sensing for mapping of planetary bodies has produced the CubeSat X-ray Telescope (CubeX) lunar mission concept. Orbiting the Moon at 6,000 km for 1 year sometime during the mid-decade solar maximum, the primary objectives of CubeX are to map lunar surface elemental abundances and to assess feasibility of x-ray pulsar timing navigation. CubeX’s Miniature X-ray Optics (MiXO) design builds on heritage of existing X-ray imaging designs using new electroformed NiCo alloy replication (ENR) to create shells of 1 mm thickness. MiXO will provide 1 arcmin resolution X-Ray imaging for an extended instantaneous field of view, at various energy range sensitivities. Based on the classic Wolter-Type I design (using a paraboloid/hyperboloid grazing mirror pair), mirror parameters were expanded to allow both shell length and focal-plane offsets to vary independently. The design was optimized with a merit function that factored together four sub-merits: PSF sharpness (measured as half-power diameter), consistency across the field, minimized scattering, and maximized effective area. Monte Carlo analysis was used to predict final performance, including surface scatter effects. The demonstrated configurations include a compact 34 shell design with a diameter of 105 mm more efficient at higher energies, and a larger 130 mm/24 shell version with a larger overall effective area at lower energies. The compact design carries more expensive fabrication and assembly cost (with more shells) as well as a more challenging alignment (with denser packing). Both have overall resolution <1’ up to 26’ off-axis and <1.5’ up to 33’ off-axis, whereas a conventional design’s image quality degrades quickly beyond 15’ off-axis. This opens up new possibilities for future SmallSat missions that could use two different configurations for wide energy ranges or midsized instruments using multiple identical modules for larger collecting area.

x-ray↗

Interferometric Characterization of the Earth's Atmosphere from Lagrange Point 2

Part of the NASA plans for future Earth Science missions calls for observations using novel vantage points that can produce science products otherwise unobtainable. Observations of the Earth from the Lagrange-2 point, L-2, (1.5 million km behind the Earth on the Earth-Sun line) affords a unique vantage point for atmospheric science. Spectral observation of the Earth's atmosphere using solar occultation techniques in the near infrared (1 to 4 microns) provides one of the most accurate methods of passively sensing attitude profiles of the major species (CO2, O3, O2, CH4, H2O N2O). While traditional polar orbiting occultation measurements can obtain about 14 measurements per day (2 per orbit), solar occultation observations from the Lagrange-2 point will yield hourly profile measurements at all latitudes. The expected spatial resolution is 2 km in altitude, 0.5 degrees in latitude, and 2 degrees in longitude. The result from 24 hours of observations will be a three-dimensional map of atmospheric composition. To accomplish this task from L-2 requires the development of a large moderate spectral resolution instrument whose entrance aperture is about 10 meters. Use of a standard telescope design with a 10-meter circular mirror or a 10-meter strip mirror would be prohibitively expensive and excessively massive. Instead, we are proposing the development of a 10-meter linear interferometer coupled to a Fourier transform imaging spectrometer. The result will be a highly efficient design with sufficient sensitivity, while having both spatial and spectral resolution to produce the desired results. Preliminary calculations show that seven species (CO2, O3, O2, CH4, H2O N2O) have clearly separated spectral features in the I to 4 microns range with sufficient absorption to produce profile information from near the Earth's surface to the middle stratosphere. For CO2 the estimated sensitivity to change is 0.33% or 1 part in 330. This should be sufficient to detect changes that are significant for the carbon cycle studies. Initial instrument design studies are underway to determine the optimum optical design for the interferometer-spectrometer as well as the necessary highly stable mechanical designs. Separate design studies are being conducted for the spacecraft. shuttle launch facility, low-light solar power design, thermal control, and unique navigation requirements to reach and maintain the tight halo orbit about L-2.

Herman, Jay R.↗

8 Meter Advanced Technology Large-Aperture Space Telescope (ATLAST-8m)

ATLAST-8m (Advanced Technology Large Aperture Space Telescope) is a proposed 8-meter monolithic UV/optical/NIR space observatory (wavelength range 110 to 2500 nm) to be placed in orbit at Sun-Earth L2 by NASA's planned Ares V heavy lift vehicle. Given its very high angular resolution (15 mas @ 500 nm), sensitivity and performance stability, ATLAST-8m is capable of achieving breakthroughs in a broad range of astrophysics including: Is there life elsewhere in the Galaxy? An 8-meter UVOIR observatory has the performance required to detect habitability (H2O, atmospheric column density) and biosignatures (O2, O3, CH4) in terrestrial exoplanet atmospheres, to reveal the underlying physics that drives star formation, and to trace the complex interactions between dark matter, galaxies, and intergalactic medium. The ATLAST Astrophysics Strategic Mission Concept Study developed a detailed point design for an 8-m monolithic observatory including optical design; structural design/analysis including primary mirror support structure, sun shade and secondary mirror support structure; thermal analysis; spacecraft including structure, propulsion, GN&C, avionics, power systems and reaction wheels; mass and power budgets; and system cost. The results of which were submitted by invitation to NRC's 2010 Astronomy & Astrophysics Decadal Survey.

Stahl, H. Philip↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

Measurements of Temperature and Enthalpy in NASA Ames 60-MW Arcjet using Atomic Oxygen and Atomic Nitrogen Absorption

We report on measurements of temperature and enthalpy in the 60-MW Interaction Heating Facility (IHF) Arcjet at the NASA Ames Research Center. These quantities were measured at sub-second temporal resolution using tunable diode laser absorption spectroscopy, employing four Distributed Feedback (DFB) lasers to simultaneously probe the arcjet flow. Optical access was achieved through a specially-designed optical disk mounted in series with the modules of the arc heater in the add-air plenum of the column, which is positioned between the downstream electrodes and the nozzle. Gas at this measurement location serves as the reservoir condition for the ensuing supersonic expansion. Conditions in the reservoir are extreme, with temperatures between 5000-8000 K and pressures between 1-9 atm. Absorption from the 5S state of atomic oxygen at 777.2 nm and the 4P state of atomic nitrogen at 868.0 nm, two electronically-excited quantum states, formed the basis of the flow characterization measurements. Fiber-coupled laser light was pitched through the IHF via 1/8" ports in the optical disks, permitting optical access with minimal intrusion to the flow. Data was collected at 3 nominal conditions, a Low condition (1600 A, 2000 V, 0.13 kg/s), a Medium condition (3500 A, 5700 V, 0.61 kg/s), and a High condition (5900 A, 6800 V, 0.84 kg/s). Measurements suggest agreement within 1-2% between excited oxygen and excited nitrogen thermometry, indicating approximate thermal and chemical equilibration of the arcjet reservoir state, a result in keeping with long-standing assumptions of CFD modelling. Spatial gradients are found in the flow due to enthalpy loss to the facility walls, but the measured spatial non-uniformities are consistent with axi-symmetry. Measurements of specific enthalpy in the reservoir are also made utilizing excited oxygen and excited nitrogen absorption under the assumption of chemical equilibration.

Peter M. Finch↗

Polarization aberrations in the solar activity measurements experiments (SAMEX) solar vector magnetograph

An optical design and polarization analysis of the Air Force/NASA Solar Activity Measurements Experiments solar vector magnetograph optical system is performed. Polarization aberration theory demonstrates that conventional telescope coating designs introduce unacceptably high levels of polarization aberrations into the optical system. Several ultralow polarization mirror and lens coatings designs for this instrument are discussed. Balancing of polarization aberrations at different surfaces is demonstrated.

Mcguire, James P., Jr.↗

Space Telescope optical telescope assembly

The optical quality and stability requirements of the Space Telescope optical design rely on state-of-the-art developments in optics, structures, and sensors. This paper describes key elements of the design implementation of the Space Telescope's performance requirements.

Mccarthy, D. J.↗