Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Development of limited-view tomography for measurement of Spray G plume direction and liquid volume fraction

Abstract The method for direct injection of fuel in the cylinder of an IC engines is important to high-efficiency and low-emission performance. Optical spray diagnostics plays an important role in understanding plume movement and interaction for multi-hole injectors, and providing baseline understanding used for computational optimization of fuel delivery. Traditional planar or line-of-sight diagnostics fail to capture the liquid distribution because of optical thickness concerns. This work proposes a high-speed (67 kHz) extinction imaging technique at various injector rotations coupled to computed tomography (CT) for time-resolved reconstruction of liquid volume fraction in three dimensions. The number of views selected and processing were based on synthetic (modeled) liquid volume fraction data where extinction and CT adequately reconstructed each plume. The exercise showed that for an 8-hole, symmetric-design injector (ECN Spray G), only three different views are enough to reproduce the direction of each plume, and particularly the mean plume direction. Therefore, the number of views was minimized for experiments to save expense. Measurements applying this limited-view technique confirm plume–plume variations also detected with mechanical patternation, while providing better spatial and temporal resolution than achieved previously. Uncertainties due to the limited view within pressurized spray chambers, the droplet size, and optically thick regions are discussed. Graphic abstract

42 ENGINEERING↗

Laser anemometry - Advances and applications 1991; Proceedings of the 4th International Conference, Cleveland, OH, Aug. 5-9, 1991. Vols. 1 & 2

The papers presented in this volume provide an overview of the latest advances in laser anemometry and optical flow diagnostics. Topics discussed include turbulence, jets, and chaos; novel optical techniques for velocity measurements; chemical reactions and combusting flows; and LDA/CFD interface. Attention is also given to particle image velocimetry, high speed flows and aerodynamic flows, internal flows, particle sizing, optics and signal processing, two-phase flows, and general fluid mechanics applications.

Dybbs, Alexander↗

The optically thick O III spectrum. I - Diagnostic ratios involving the intercombination lines

An escape-probability calculation of the optically thick O III spectrum is carried out to obtain the optical depth dependence of the intercombination doublet at 1663 A and of resonance lines between the 2p2, 2s2p3, and 2p4 configurations. The effect of optical depth on diagnostic ratios involving the intercombination lines is quantitatively established. The general question raised is whether such effects may occur in actual sources.

Kastner, S. O.↗

Measurement of the Energy Spread for CeC Project

The Coherent Electron Cooling requires small energy spread and uniformity of energy along the bunch. The diagnostics line is utilized for the measurement of the electron beam parameters. The beamline layout is shown in Fig. 1. Three quadrupoles after the linac are used to match beam into the common section. The main dipole is used to deflect beam towards common section. If it is switched off the beam goes to the diagnostics line. The beam optics in the diagnostics line is controlled by four quadrupoles. The deflecting cavity sweeping beam in the vertical direction follows the quadrupoles. Sector dipole is used for energy parameters measurement. It has deflection angle of 30 degrees. With diagnostics dipole switched off the beam propagated to the insertable slits system for emittance measurement. There are four profile monitors in the line, The first profile monitor (ACC YAG) is after the main dipole. The second profile monitor (YAG3) is in front of the diagnostics dipole after the deflecting cavity. YAG1 profile monitor is placed after the slits, and YAG2 profile monitor is placed after the diagnostics dipole. There is a solenoid between the deflecting cavity and YAG3. It is used for the beam energy measurement.

43 PARTICLE ACCELERATORS↗

High level of integration of front-end imaging optics system for electron cyclotron emission imaging diagnostics on the DIII-D tokamak

The optics system of the Electron Cyclotron Emission Imaging (ECEI) diagnostics on the DIII-D tokamak has been developed and installed for high-resolution temperature fluctuations measurement in the previous decade. The System-on-Chip approach upgrade was finished in June 2019 with high integrated receiver array with 20 individual modules. In this paper, we design new optics with high-level integration. In the new optics system, there will be two mirrors from plasma to receiver array, including one replaceable curved mirror out of the vacuum and one fixed curved mirror in the vessel. There are two options with 1:1 and 1:2 magnifications for high poloidal resolution and larger poloidal window modes. Overall, the new optics system has multiple improvements, including lighter weight, smaller size, more flexible installation and alignment. The synthetic ECEI module is used to evaluate the new optics system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical property measurements as a diagnostic tool for control of materials processing in space and on Earth

A new method is described, including results, to measure, control, and follow containerless processing in ground based levitators. This technique enables instantaneous optical property measurements from a transient solid or liquid surface concurrent with true temperature measurement. This was used successfully as a diagnostic tool to follow processing of Al, Si, and Ti during electromagnetic levitation. Experiments on Al show the disappearance of the oxide (emittance 0.33) at ca. 1300 C leaving a liquid surface with an emittance of 0.06. Electromagnetic levitation of silicon shows a liquid with a constant emittance (0.2) but with a solid whose emittance decreases very rapidly with increasing temperature. Consequently, the processing of materials at high temperatures can be controlled quite well through the control of surface optical properties.

Krishnan, Shankar↗

The Low-redshift Lyman Continuum Survey. II. New Insights into LyC Diagnostics

The Lyman continuum (LyC) cannot be observed at the epoch of reionization (z ≳ 6) owing to intergalactic H I absorption. To identify LyC emitters (LCEs) and infer the fraction of escaping LyC, astronomers have developed various indirect diagnostics of LyC escape. Using measurements of the LyC from the Low-redshift Lyman Continuum Survey (LzLCS), we present the first statistical test of these diagnostics. While optical depth indicators based on Lyα, such as peak velocity separation and equivalent width, perform well, we also find that other diagnostics, such as the [O III ]/[O II ] flux ratio and star formation rate surface density, predict whether a galaxy is an LCE. The relationship between these galaxy properties and the fraction of escaping LyC flux suggests that LyC escape depends strongly on H I column density, ionization parameter, and stellar feedback. We find that LCEs occupy a range of stellar masses, metallicities, star formation histories, and ionization parameters, which may indicate episodic and/or different physical causes of LyC escape.

79 ASTRONOMY AND ASTROPHYSICS↗

Variable Active Galactic Nuclei in the Galaxy Evolution Explorer Time Domain Survey

We searched the northern hemisphere fields of the Galaxy Evolution Explorer Time Domain Survey for galaxies with UV variability indicative of active galactic nuclei (AGNs). We identified 48 high-probability candidate AGNs from a parent sample of 1819 galaxies in the NASA Sloan Atlas catalog. We further characterized these systems using optical spectroscopic diagnostics, Wide-field Infrared Survey Explorer IR color selection criteria, and spectral energy distribution modeling. Of the 48 candidates, eight were identified as AGNs from optical emission lines, two were identified by their IR colors, and 28 were identified through spectral energy decomposition. Observational biases of each selection method are discussed in connecting these AGN subsamples to another. By selecting AGNs based on UV variability, we also identified six low-mass AGN candidates, all of which would have been missed by spectroscopic selection.

79 ASTRONOMY AND ASTROPHYSICS↗

'Diamondlike' carbon films - Optical absorption, dielectric properties, and hardness dependence on deposition parameters

An RF plasma deposition system was used to prepare amorphous 'diamondlike' carbon films. The source gases for the RF system include methane, ethylene, propane, and propylene, and the parameters varied were power, dc substrate bias, and postdeposition anneal temperature. Films were deposited on various substrates. The main diagnostics were optical absorption in the visible and in the infrared, admittance as a function of frequency, hardness, and Auger and ESCA spectroscopy. Band gap is found to depend strongly on RF power level and band gaps up to 2.7 eV and hardness up to 7 Mohs were found. There appears to be an inverse relationship between hardness and optical band gap.

Natarajan, V.↗

Effects and mitigation of pulsed power radiation on optical fiber velocimetry

We report optical fiber diagnostics are extensively used in pulsed power experiments, such as the Sandia Z machine. However, radiation produced in a pulsed power environment can significantly affect these measurements. Catastrophic fiber darkening may be mitigated with shielding, but no flexible material can stop all radiation produced by the machine and/or target. Radiation-induced refractive index modulations are particularly challenging for optical interferometry. Several approaches for radiation-tolerant photonic Doppler velocimetry are discussed here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Holographic, particle imaging and data reduction at Spectron Development Laboratores

Spectron has been deeply involved in the development and use of a wide variety of particle and flow diagnostic, electro optical instruments. Holography and imaging systems have played an important role in this work, but the extraction of data from images and holograms have always presented a limit to their use. Systems and techniques were devised to speed up and automate the extraction of data from holographic and conventional interferograms, particle images and holograms, and other types of optical flow visualization techniques. An IBM/AI based image analyzer was developed that is capable of automatically analyzing many useful image types including interferograms. A key feature of this system is the low total cost of the required hardware. In the particle field work, a commercial diffraction field analyzer was adopted to the image reconstructed from a hologram. This could expand the use of holography in particle diagnostics greatly.

Trolinger, James D.↗

Optical depth of molecular gas in starburst galaxies - Is M82 the prototype?

An attempt is made to survey the CO(2-1) emission toward the centers of 17 IR-luminous galaxies which have previously been detected in CO(1-0). These galaxies span a wide range of size and L(FIR)/L(B) ratio, many have multiple-wavelength studies establishing them as starbursts, and some bear a morphological resemblance to M 82. Nine galaxies are detected and useful upper limits are placed on the remaining eight. Using the CO(2-1)/CO(1-0) ratio of antenna temperature as a diagnostic of optical depth, it is found that all of the galaxies contain predominantly optically thick molecular gas. This implies that the phase of starburst during which the molecular gas is optically thin, currently witnessed in M 82, is either uncommon or short-lived.

Verter, F.↗

RIC Advanced Sensors & Controls FWP: Novel Sensors for Boilers

Overview and brief project update on 3 tasks within the RIC Advanced Sensors & Controls FWP with direct applications to coal fired boiler temperature sensing. Task 32, Field demonstration of distributed temperature measurement with optical fiber for fossil energy power generation applications. Task 47, In-situ temperature measurements via reactive particles. Task 48, Ultrafast laser measurements for power generation environments.

coal boilers↗

Overview of Extractive and Optical PM Measurements from the NASA SE-5 High Pressure Flame Diagnostics Laboratory

Soot emissions measurements of multiphase non-premixed flames are sparse in the literature due to the complexities of sampling in such environments. We present an overview from on-going work at the NASA SE-5 High Pressure Flame Diagnostics laboratory focusing on soot and gaseous emissions at elevated pressures. SE-5 is a gaseous and liquid fueled high pressure flame tube facility capable of operating at pressures up to 880 psia, cooling capacity of 4,000,000 BTU/hr, liquid fuel flow rates up to 2 GPH, and an equivalence ratio range of 0.2 (fuel lean) to 4 (fuel rich). SE-5 provides optical access via four UV-grade fused silica optical windows of the primary reaction zone enabling non-intrusive optical diagnostics of the flame.

Soot↗

Continuum laser absorption spectroscopy of C 2 (a 3 Π u ) in a sublimating cloud of carbon black

A direct optical absorption diagnostic has been developed for rotationally resolved measurements of diatomic carbon (a 3 Π u →d 3 Π g (0,0) and (1,1)) at a repetition rate of 525 kHz and resolution of 7.3 pm over the range of 511.1–514.1 nm. The diagnostic utilizes a high-power pulsed continuum laser light source dispersed in a spectrograph and imaged by a high-speed camera. Measurements have been performed that capture the temporal evolution of C 2 number density and temperature of a cloud of carbon black sublimating in shock heated gas at high temperature and pressure (T = 5500 K, P = 3.7 atm). A simultaneous light absorption measurement of the condensed phase enables comparisons of the gaseous C 2 number density to the condensed phase mass. The continuum laser absorption diagnostic is applied to C 2 in this work but shows promise in being a simple “drop-in” system for absorption spectroscopy in the visible range at rapid repetition rates and high dispersion, filling an important gap for laser diagnostic systems.

Willhardt, Colton Dean [Univ. of Illinois at Urban↗

Diffuse back-illumination temperature imaging (DBI-TI), a novel soot thermometry technique

To meet stringent emissions regulations on soot emissions, it is critical to further advance the fundamental understanding of in-cylinder soot formation and oxidation processes. Among several optical techniques for soot quantification, diffuse back-illumination extinction imaging (DBI-EI) has recently gained traction mainly due to its ability to compensate for beam steering, which if not addressed, can cause unacceptably high measurement uncertainty. Until now, DBI-EI has only been used to measure the amount of soot along the line of sight, and here, we extend the capabilities of a DBI-EI setup to also measure in-cylinder soot temperature. This proof of concept of diffuse back-illumination temperature imaging (DBI-TI) as a soot thermometry technique is presented by implementing DBI-TI in a single cylinder, heavy-duty, optical diesel engine to provide 2-D line-of-sight integrated soot temperature maps. The potential of DBI-TI to be an accurate thermometry technique for use in optical engines is analyzed. The achievable accuracy is due in part to simultaneous measurement of the soot extinction, which circumvents the uncertainty in dispersion coefficients that depend on the optical properties of soot and the wavelength of light utilized. Analysis shows that DBI-TI provides temperature estimates that are closer to the mass-averaged soot temperature when compared to other thermometry techniques that are more sensitive to soot temperature closer to the detector. Furthermore, uncertainty analysis and Monte Carlo (MC) simulations provide estimates of the temperature measurement errors associated with this technique. The MC simulations reveal that for the light intensities and optical densities encountered in these experiments, the accuracy of the DBI-TI technique is comparable or even better than other established optical thermometry techniques. Thus, DBI-TI promises to be an easily implementable extension to the existing DBI-EI technique, thereby extending its ability to provide comprehensive line-of-sight integrated information on soot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Erosion resistance test of SiC mirror sample for ITER divertor VUV spectrometer

A series of tests have been performed to validate the resistance of the Silicon Carbide (SiC) mirror as the first mirror material of ITER VUV spectrometers to all ITER environmental conditions. Here we focused on the erosion (and deposition) of the SiC mirror sample caused by high-energy neutral particles. The flux of neutral particles reaching the first mirror was calculated using the ZEMAX software with a simplified entrance duct model. In the calculation, the particle flux reaching the first wall is necessary and the previously reported values derived from the SOLPS calculations were used. Based on this estimated particle flux, the erosion resistance tests were performed to check the erosion effect due to the high-energy neutral particles on the first mirror of ITER divertor VUV spectrometer. In the experiment, erosion was induced by exposing the SiC mirror sample to hydrogen and deuterium plasmas (and ions). The target fluence of incident ions in experiment is based on the estimation of the flux of neutral particles in ITER. The surface shape, composition, erosion depth, and surface roughness were measured to check the damage of the mirror surface after erosion test. Based on simulations and erosion resistance tests, it was concluded that the SiC mirror can be used as the first mirror of ITER divertor VUV spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rovibronic molecular line list for the $N_2(C^3Π_u–B^3Π_g)$ second positive system

Here, a line list for the N second positive system, $B^3Π_g—C^3Π_u$, has been compiled using the PGOPHER spectral simulation software. The line list extends the number of vibrational states of the $B^3Π_g$ up to v=29 and a maximum rotational state of J=150 for simulation temperatures up to 7000 K. New electronic–vibrational transition moments were calculated using refined potential energy curves and a transition dipole moment with the DUO software. Comparisons to experimental data and the SPECAIR software have been used to validate the new line list. The results are available in ASCII ExoMol .state and .trans files and as a PGOPHER input file for use in spectral analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗