At least 271 records · Page 15

Clock Precision beyond the Standard Quantum Limit at 10 −18 Level

Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1 × 10 −18 for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.

cavity quantum electrodynamics↗

An Improved Algorithm for Estimating Surface Shortwave Radiation: Preliminary Evaluation With MODIS Products

Cloud parameters, as key inputs in radiative transfer algorithms, have a critical impact on surface shortwave radiation (SSR) computation. By introducing a parameterization of cloud transmittance and reflectance, based on radiative transfer simulations, this study improves the accuracy of an existing physically based model which severely underestimates SSR under thick cloud conditions. The cloud parameterization adopts the single-layer cloud model and simulates cloud transmittances and reflectances by varying cloud optical thickness, cloud particle size, and solar zenith angle. The revised model is applied to estimate instantaneous SSR using Moderate-resolution Imaging Spectroradiometer (MODIS) atmospheric and land products. The retrieved SSR is evaluated against observation data from 41 Baseline Surface Radiation Network (BSRN) stations and is also compared with the MODIS official SSR product. The root mean square error (RMSE) of the estimated instantaneous radiation is approximately 52 and 98 W m -2 under clear-sky and all-sky conditions, respectively. The accuracy of the improved parameterization is higher than that of the original model, and there is no obvious underestimation of SSR in the case of high cloud optical thickness. Therefore, the new algorithm improves the accuracy of SSR estimates in the presence of thick clouds. Retrievals with the improved model also achieve higher accuracy than the MODIS official SSR product (MCD18A1). To conclude, the reliable performance of the scheme at most BSRN stations illustrates that the improved model can be used to map SSR on a global scale.

42 ENGINEERING↗

Integrating Radio-Over-Fiber Communication System and BOTDR Sensor System

In this paper, we propose and experimentally demonstrate for the first time, the integration of a radio-over-fiber (RoF) communication system and a Brillouin optical time-domain reflectometry (BOTDR) distributed sensor system using a single optical fiber link. In this proof-of-concept integrated system, the communication system is composed of three modulation formats of quadrature phase-shift keying (QPSK), 16-quadrature amplitude modulation (16-QAM) and 64-QAM, which are modulated onto an orthogonal frequency division multiplexing (OFDM) signal. Whereas, the BOTDR sensor system is used for strain and/or temperature monitoring over the fiber distance with a spatial resolution of 5 m using a 25 km single-mode silica fiber. The error vector magnitude (EVM) is analyzed in three modulation formats in the presence of various BOTDR input pump powers. Using QPSK modulation, optimized 18 dBm sensing and 10 dBm data power, the measured EVM values with and without bandpass filter are 3.5% and 14.5%, respectively. The proposed system demonstrates a low temperature measurement error (±0.49 °C at the end of 25 km) and acceptable EVM values, which were within the 3GPP requirements. The proposed integrated system can be effectively applied for practical applications, which significantly reduces the fiber infrastructure cost by effective usage of a single optical fiber link.

42 ENGINEERING↗

Optimizing qubit control pulses for state preparation

In the burgeoning field of quantum computing, the precise design and optimization of quantum pulses are essential for enhancing qubit operation fidelity. This study focuses on refining the pulse engineering techniques for superconducting qubits, employing a detailed analysis of square and Gaussian pulse envelopes under various approximation schemes. We evaluated the effects of coherent errors induced by naive pulse designs. Furthermore, we identified the sources of these errors in the Hamiltonian model’s approximation level. We mitigated these errors through adjustments to the external driving frequency and pulse durations, thus implementing a pulse scheme with stroboscopic error reduction. Our results demonstrate that these refined pulse strategies improve performance and reduce coherent errors. Moreover, the techniques developed herein are applicable across different quantum architectures, such as ion-trap, atomic, and photonic systems.

Chirp modulation↗

Nonlinear optics from hybrid dispersive orbits

Here in this paper we expand the technique of characterizing nonlinear optics from off-energy closed orbits (NOECO) to cover harmonic sextupoles in storage rings. The existing NOECO technique has been successfully used to correct the chromatic sextupole errors on the MAX-IV machine (Olsson et al., 2020), however, it does not account for harmonic sextupoles, which are still widely used on many other machines. By generating vertical dispersion with chromatic skew quadrupoles, a measurable chromatic function dependence on harmonic sextupoles can be observed on hybrid dispersive orbits. Proof of concept of this technique was accomplished by simulations and beam measurements on the National Synchrotron Light Source II (NSLS-II) storage ring.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Generalised hyper-Ramsey spectroscopy of two-level atoms in an optically dense medium

The peculiarities of Ramsey resonance and its sensitivity to the light shift from an optically dense medium of cold atoms are investigated. Different composite pulse protocols for clock spectroscopy, including hyper-Ramsey, modified and generalised hyper-Ramsey schemes, are compared. Error signals change significantly due to the processes of absorption and dispersion in the atomic medium. The dependence of the position of the central fringe resonance with a residual uncompensated light shift of the atomic transition is studied with the attenuation of the radiation intensity in the medium taken into account. It is shown that using a combination of generalised hyper-Ramsey error signals allows one to suppress the sensitivity to the light shift for any length of the medium. (laser cooling of atoms)

74 ATOMIC AND MOLECULAR PHYSICS↗

Squeezed light quantum imaging - experiment

This year, we focused on completing the light squeezing and building the imaging station. In this report, we present a detailed description of a quantum imaging experiment utilizing squeezed light. The entire experimental setup has two parts, namely, the squeezing station where we produce quantum-noise squeezed light where a light quadrature (either the amplitude of the phase) has reduced quantum error below the shot noise of coherent light, and the imaging station where the squeezed light is used to image an object. The squeezing station consists of an optical parametric oscillator operating below the laser threshold. We provide the status quo and the plans for the squeezing imaging experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear optics from hybrid dispersive orbits

In this paper we expand the technique of characterizing nonlinear optics from off-energy closed orbits (NOECO) to cover harmonic sextupoles in storage rings. The existing NOECO technique has been successfully used to correct the chromatic sextupole errors on the MAX-IV machine [Olsson et al., Phys. Rev. Accel. Beams 23, 102803], however, it does not account for harmonic sextupoles, which are still widely used on many other machines. By generating vertical dispersion with chromatic skew quadrupoles, a measurable chromatic function dependence on harmonic sextupoles can be observed on hybrid dispersive orbits. Proof of concept of this technique was accomplished by simulations and beam measurements on the National Synchrotron Light Source II (NSLS-II) storage ring.

43 PARTICLE ACCELERATORS↗

Pressure-Driven Fiber-Optic Sensor for Online Corrosion Monitoring

For many industrial applications, corrosion is a life-limiting phenomenon and therefore requires careful consideration and rigorous experimental testing before structural materials can be reliably deployed, particularly in harsh chemical environments. The traditional approach to measuring corrosion requires exposing many samples to the intended environment and then extracting them individually at discrete intervals for postexposure characterization. This approach does not provide a high degree of temporal resolution, nor does it provide any real-time information regarding dynamic changes in corrosion rates. Additionally, developing an online corrosion monitor capable of surviving harsh chemical environments could provide valuable information regarding the structural health of components and changing process conditions that could accelerate corrosion. To this end, a corrosion sensor was developed based on a pressure-driven Fabry-Pérot cavity (FPC). This sensor uses a pressure control system to internally pressurize the FPC formed between the sensor’s housing and a metal-embedded singlemode optical fiber. Simultaneous measurement of the change in FPC length using low-coherence interferometry and the applied pressure enables the calculation of the relative changes in the sensor’s diaphragm thickness due to corrosion on its outer surface. Measurements were made in situ while actively corroding the sensor and were validated against surveillance specimens that were corroded simultaneously. The uncertainties in the measured corrosion were analyzed using error propagation of the uncertainties in the measured pressures and displacements and were found to be <1% of the initial diaphragm thickness.

42 ENGINEERING↗

Distributed fiber optic strain sensing of bending deformation of a well mockup in the laboratory

Well integrity is critical to the safety and success of subsurface energy exploration and management, as leakage of fluids from subsurface reservoirs is often induced by compromised wells. This study investigates bending deformation of a mockup of an oil/gas well that is subjected to loads expected in deviated wells under reservoir compaction and assesses the feasibility of utilizing distributed fiber optic strain sensing to monitor the deformation. Here, a well mockup, which consists of outer and inner steel pipes with a cemented annulus, is tested under three-point bending loading and its strain and curvature development is monitored by Brillouin optical time domain reflectometry/analysis (BOTDR/A) as well as optical frequency domain reflectometry (OFDR). The primary objective of this research is to assess the strain sensing performance of newly fabricated fiber optic cables and to identify key cable characteristics which could improve the quality of distributed strain measurements with BOTDR/A. Results show that the tight-buffered cable is best suited for strain sensing as its maximum errors in the strain measurement were -36% and -24% against conventional sensors at the maximum elastic and plastic bending loads, respectively, whereas those of the non-tight-buffered cable were -45% and -71%, respectively. Similar trends were obtained in the bending curvature measurement. The detailed design of the tight-buffered cable is presented to elucidate key characteristics of such a cable, which will facilitate accurate distributed strain sensing in oil and gas wells.

42 ENGINEERING↗

Effects of head modeling errors on the spatial frequency representation of MEG

Abstract Objectives. We aim to investigate the effects of head model inaccuracies on signal and source reconstruction accuracies for various sensor array distances to the head. This allows for the assessment of the importance of head modeling for next-generation magnetoencephalography (MEG) sensors, optically-pumped magnetometers (OPM). Approach. A 1-shell boundary element method (BEM) spherical head model with 642 vertices of radius 9 cm and conductivity of 0.33 S m −1 was defined. The vertices were then randomly perturbed radially up to 2%, 4%, 6%, 8% and 10% of the radius. For each head perturbation case, the forward signal was calculated for dipolar sources located at 2 cm, 4 cm, 6 cm and 8 cm from the origin (center of the sphere), and for a 324 sensor array located at 10 cm to 15 cm from the origin. Equivalent current dipole (ECD) source localization was performed for each of these forward signals. The signal for each perturbed spherical head case was then analyzed in the spatial frequency domain, and the signal and ECD errors were quantified relative to the unperturbed case. Main results. In the noiseless and high signal-to-noise ratio (SNR) case of approximately ≥6 dB, inaccuracies in our spherical BEM head conductor models lead to increased signal and ECD inaccuracies when sensor arrays are placed closer to the head. This is true especially in the case of deep and superficial sources. In the noisy case however, the higher SNR for closer sensor arrays allows for an improved ECD fit and outweighs the effects of head geometry inaccuracies. Significance. OPMs may be placed directly on the head, as opposed to the more commonly used superconducting quantum interference device sensors which must be placed a few centimeters away from the head. OPMs thus allow for signals of higher spatial resolution to be captured, resulting in potentially more accurate source localizations. Our results suggest that an increased emphasis on accurate head modeling for OPMs may be necessary to fully realize its improved source localization potential.

Yeo, Wan-Jin (ORCID:0000000241417123)↗

A Chip-Scale Oscillation-Mode Optomechanical Inertial Sensor Near the Thermodynamical Limits

Modern navigation systems integrate the global positioning system (GPS) with an inertial navigation system (INS), which complement each other for correct attitude and velocity determination. Here, the core of the INS integrates accelerometers and gyroscopes used to measure forces and angular rate in the vehicular inertial reference frame. With the help of gyroscopes and by integrating the acceleration to compute velocity and distance, precision and compact accelerometers with sufficient accuracy can provide small–error location determination. Solid–state implementations, through coherent readout, can provide a platform for high performance acceleration detection. In contrast to prior accelerometers using piezoelectric or capacitive readout techniques, optical readout provides narrow–linewidth high–sensitivity laser detection along with low–noise resonant optomechanical transduction near the thermodynamical limits. Here an optomechanical inertial sensor with an 8.2 µg Hz –1/2 velocity random walk (VRW) at an acquisition rate of 100 Hz and 50.9 µg bias instability is demonstrated, suitable for applications, such as, inertial navigation, inclination sensing, platform stabilization, and/or wearable device motion detection. Driven into optomechanical sustained–oscillation, the slot photonic crystal cavity provides radio–frequency readout of the optically–driven transduction with an enhanced 625 µg Hz –1 sensitivity. Measuring the optomechanically–stiffened oscillation shift, instead of the optical transmission shift, provides a 220× VRW enhancement over pre–oscillation mode detection.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Designing ITER motional Stark effect line shift (MSE-LS) spectrometers

As a part of ITER beam aided diagnostics, the design of Motional Stark Effect (MSE) diagnostic observing the emission from the Balmer-α line is underway. The physics of Stark splitting shows that the Stark manifold is polarization dependent, and the energy splitting results in a line shift proportional to the electric field. Due to the challenges of maintaining the calibration of the plasma facing mirrors in ITER, the conventional MSE polarimetry measurement technique is replaced with a spectral approach that is deemed more favorable in the ITER environment. The MSE line shift (LS) diagnostic is designed to quantify the Lorentz electric field magnitude by measuring the Stark manifold using visible spectroscopy. In the presence of large magnetic fields and high energy heating beams of 1 MeV, the expected Stark splitting is much larger than in typical devices. The MSE-LS design has unique challenges requiring careful consideration and modeling of its viewing geometry and photon budget. The MSE-LS approach on ITER is promising but has stringent demands on the allowable errors for the statistical and systematic fitting uncertainties. In this study, a full system model and numerical simulations of data for each sightline are completed. For a range of optical transmission fractions, photon noise analysis is conducted to determine the statistical uncertainties. This provides guidance on the spectrometer throughput, dispersion at the detector, optics, and other design choices. A conceptual design of a high throughput spectrometer with a volume phase transmission grating is presented.

Instruments & Instrumentation↗

Towards robust laser beam propagation in atmospheric turbulence

High-fidelity optical propagation through the atmosphere is essential for free-space optical technologies, including laser-based remote sensing and optical communication. However, atmospheric turbulence severely distorts beams and compromises system performance. In this work, we employ hypergeometric-Gaussian (HyGG) vortex beams as probes to characterize and mitigate atmospheric turbulence. Using over 250,000 experimental and simulated frames, we show that refining the power spectrum density (PSD) can reduce numerical prediction errors by up to 79.8%. Concurrently, experimental observations supported by numerical simulations demonstrate that HyGG beams exhibit superior turbulence resilience across multiple metrics compared to conventional Gaussian beams, particularly in their ability to withstand over 5 times stronger turbulence while maintaining similar intensity fluctuations. These dual investigations, on both turbulence mitigation and robust beam solutions, converge to form a unified strategy for enhancing free-space optical system performance. Collectively, our findings provide new insights into light–turbulence interactions and highlight the practical utility of vortex beams under atmospheric conditions.

Zhang, Boyu↗

Statistical Tool Size Study for Computer-Controlled Optical Surfacing

Over the past few decades, computer-controlled optical surfacing (CCOS) systems have become more deterministic. A target surface profile can be predictably achieved with a combination of tools of different sizes. However, deciding the optimal set of tool sizes that will achieve the target residual error in the shortest run time is difficult, and no general guidance has been proposed in the literature. In this paper, we present a computer-assisted study on choosing the proper tool size for a given surface error map. First, we propose that the characteristic frequency ratio (CFR) can be used as a general measure of the correction capability of a tool over a surface map. Second, the performance of different CFRs is quantitatively studied with a computer simulation by applying them to guide the tool size selection for polishing a large number of randomly generated surface maps with similar initial spatial frequencies and root mean square errors. Finally, we find that CFR = 0.75 achieves the most stable trade-off between the total run time and the number of iterations and thus can be used as a general criterion in tool size selection for CCOS processes. To the best of our knowledge, the CFR is the first criterion that ties tool size selection to overall efficiency.

36 MATERIALS SCIENCE↗

Qubit control noise spectroscopy with optimal suppression of dephasing

Here, we extend quantum noise spectroscopy (QNS) of amplitude control noise to settings where dephasing noise or detuning errors make significant contributions to qubit dynamics. Previous approaches to characterize amplitude noise are limited by their vulnerability to low-frequency dephasing noise and static detuning errors, which can overwhelm the target control noise signal and introduce bias into estimates of the amplitude noise spectrum. To overcome this problem, we leverage optimal control to identify a family of amplitude control waveforms that optimally suppress low-frequency dephasing noise and detuning errors, while maintaining the spectral concentration in the amplitude filter essential for spectral estimation. The waveforms found via numerical optimization have surprisingly simple analytic forms, consisting of oscillating sine waves obeying particular amplitude and frequency constraints. In numerically simulated QNS experiments, these waveforms demonstrate superior robustness, enabling accurate estimation of the amplitude noise spectrum in regimes where existing approaches are biased by low-frequency dephasing noise and detuning errors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PtychoShelves , a versatile high-level framework for high-performance analysis of ptychographic data

Over the past decade, ptychography has been proven to be a robust tool for non-destructive high-resolution quantitative electron, X-ray and optical microscopy. It allows for quantitative reconstruction of the specimen's transmissivity, as well as recovery of the illuminating wavefront. Additionally, various algorithms have been developed to account for systematic errors and improved convergence. With fast ptychographic microscopes and more advanced algorithms, both the complexity of the reconstruction task and the data volume increase significantly. PtychoShelves is a software package which combines high-level modularity for easy and fast changes to the data-processing pipeline, and high-performance computing on CPUs and GPUs.

97 MATHEMATICS AND COMPUTING↗