Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The resolution of point sources of light as analyzed by quantum detection theory

The resolvability of point sources of incoherent light is analyzed by quantum detection theory in terms of two hypothesis-testing problems. In the first, the observer must decide whether there are two sources of equal radiant power at given locations, or whether there is only one source of twice the power located midway between them. In the second problem, either one, but not both, of two point sources is radiating, and the observer must decide which it is. The decisions are based on optimum processing of the electromagnetic field at the aperture of an optical instrument. In both problems the density operators of the field under the two hypotheses do not commute. The error probabilities, determined as functions of the separation of the points and the mean number of received photons, characterize the ultimate resolvability of the sources.

Helstrom, C. W.↗

Heat pipe flight experiments

OAO 3 heat pipe flight experiments to check out weightlessness behavior are reported. Tested were a hollow channel screen system with helical grooves, a heat pipe with a wicking system of horizontal grooves, and a spiral artery pipe with multichannel fluid return to the evaporator. Flight experiment data proved that all heat pipe geometries containing wicking systems provided uninterrupted fluid return to the condensators during weightlessness and sufficient cooling for isothermalizing optical instruments onboard OAO.

Ollendorf, S.↗

Optimum detection of an optical image on a photoelectric surface.

The image-detecting performance of an optimum counting detector is compared with that of a threshold detector and that of a detector basing its decisions on the total number of photoelectrons from a finite area of the image. The illuminance of the image is assumed to have a Gaussian spatial distribution. The optimum detector works with the pristine datum (and not with the photoelectric response) which is the spatiotemporal electromagnetic field at the aperture of the observing optical instrument. It is shown that little is to be gained by using details of the illuminance distribution beyond the crude knowledge of its breadth as embodied in a simple counter of emitted photoelectrons. All three detectors exhibit accordingly about the same reliability.

Helstrom, C. W.↗

Resolution of point sources of light as analyzed by quantum detection theory.

The resolvability of point sources of incoherent thermal light is analyzed by quantum detection theory in terms of two hypothesis-testing problems. In the first, the observer must decide whether there are two sources of equal radiant power at given locations, or whether there is only one source of twice the power located midway between them. In the second problem, either one, but not both, of two point sources is radiating, and the observer must decide which it is. The decisions are based on optimum processing of the electromagnetic field at the aperture of an optical instrument. In both problems the density operators of the field under the two hypotheses do not commute. The error probabilities, determined as functions of the separation of the points and the mean number of received photons, characterize the ultimate resolvability of the sources.

Helstrom, C. W.↗

Inexpensive lightweight mirror

Aluminized Mylar film is bonded to polyurethane foam mold; Mylar is then removed, leaving highly reflective coating of aluminum on foam. Mold may be used repeatedly to make mirrors for several optical instruments. Large mirrors of almost any shape may be made singularly or in quantity.

Badhwar, G. D.↗

Measurements of optical and midday auroras

Measurements made in the midday auroras are analyzed and compared to measurements from the nighttime auroras. Examples are given of coordinated programs in Alaska which involve satellites, radars, ground optical instrumentation, and other types of observing satellites for the study of auroras.

Sivjee, G. G.↗

Test program on the contamination of ultraviolet region mirrors by Apollo Telescope Mount materials

Results are presented of testing performed to measure the effects of material outgas products on the reflectances of ultraviolet-region mirrors. These tests were to provide data on changes of ultraviolet reflectances of first-surface mirrors which had been exposed to the outgas products of selected materials under specific time and thermal-vacuum conditions. The requirement for such data was based on the extreme sensitivity of the sophisticated optical instruments in the Skylab mission's Apollo Telescope Mount (ATM) to condensed outgas products from materials, and on the desire to insure that no serious hazard of contaminating these instruments existed.

Austin, J. D.↗

Optical devices

Report describes thirty concepts and techniques developed for optical instrumentation and light transmission and generation, including spectrometer components, telescopes and microscopes, and holographic cameras.

Source record↗

Optical devices: A compilation

Technological developments in the field of optics devices which have potential utility outside the aerospace community are described. Optical instrumentation, light generation and transmission, and laser techniques are among the topics covered. Patent information is given.

Source record↗

Correlated observations of several auroral substorms on February 17, 1971

The purpose of this study is to correlate in detail auroral activity with the corresponding disturbances in the magnetotail. The auroral data were recorded by optical instruments aboard an airplane flying over the Arctic Ocean along the Alaska meridian and by the Alaska meridian chain of all-sky cameras. The corresponding magnetotail observations were made by various instruments on Vela 6A and Imp 5; the interplanetary magnetic field was monitored concurrently by Explorer 35. Three successive substorms were observed on February 17, 1971. Each substorm was readily identified by the classical auroral and magnetic signatures which accompanied its onset. The observed variations of plasma and magnetic field in the magnetotail were consistent with the idea that a neutral line formed in the range X sub SM between -12 and -18 R sub E at the onset of each substorm expansive phase and then moved tailward past X sub SM = -18 R sub E some tens of minutes afterward. The Z component of the tail magnetic field decreased rather steadily for a period of 1-2 1/2 hours after each substorm and until the onset of the next expansive phase, reaching a minimum value just before each onset.

Hones, E. W., Jr.↗

Results of the asteroid-meteoroid particle experiment on Pioneer 11

The Asteroid-Meteoroid Detector, an electro-optical instrument that detects and measures particles in space by sensing the sunlight reflected from them, is part of the payload of both the Pioneer 10 and 11 spacecraft. The Pioneer 11 instrument is essentially identical to that on Pioneer 10, with some minor modifications. Reduction of the Pioneer 11 data was complicated by the failure of one of the four sensor channels at about 1.1 AU from the sun. Detailed analysis yielded 51 events between 1.0 and 3.5 AU, which were used to determine the particle concentration distribution in that region of space. Weighted curve-fitting of the results shows agreement with the concentrations derived from Pioneer 10 to within about a factor of two. As with the Pioneer 10 results, the exponent of the size dependency varies from about -1.7 for 100-micron radius particles to about -3.2 for 10-cm bodies. The instrument, its operation, and the method of data analysis are reviewed.

Soberman, R. K.↗

Laser probe for measuring 2-D wave slope spectra of ocean capillary waves

A laser-optical instrument for use in determining the two-dimensional wave-slope spectrum of ocean capillary waves is described. The instrument measures up to a 35-deg tip angle of the surface normal by measuring the position of a refracted laser beam directed vertically upward through a water surface. A telescope, a continuous two-dimensional Schottky barrier photodiode, and a pair of analog dividers render the signals independent of water height and insensitive to laser-beam intensity fluctuations. Calibration is performed entirely in the laboratory before field use. Sample records and wave-slope spectra are shown for one-dimensional wave-tank tests and for two-dimensional ocean tests. These are presented along with comparison spectra for calm and choppy water conditions. A mechanical wave follower was used to adjust the instrument position in the presence of large ocean swell and tides.

Palm, C. S.↗

Cosine-corrected optical diffuser

In solar energy utilization studies, correct measurements of flux arriving at other angles to optical axis must be given. Developed device (Cosine diffuser) significantly reduces measurement errors. In combination of radiation transmitter and diffuser co-operating with collimated optical instrument, relative aperture of instrument is filled.

Estey, R. S.↗

Real Time Dust Fall Monitor (RTDFM)

A prototype ultraviolet optical instrument designed and developed to monitor 300 level surface cleanliness is described. Size, weight, sensitivity, and simplicity design parameters were satisfied. Tests were conducted with various configurations of the detector array and sample surfaces. Circuit schematics are included. It is shown that output drift is due to effective lamp intensity variations. The instrument is intended to be a part of the integrated environmental contamination monitor of the space shuttle.

Claysmith, C. R.↗

Procedures for dealing with certain types of noise and systematic errors common to many Hadamard transform optical systems

Sources of noise and error correcting procedures characteristic of Hadamard transform optical systems were investigated. Reduction of spectral noise due to noise spikes in the data, the effect of random errors, the relative performance of Fourier and Hadamard transform spectrometers operated under identical detector-noise-limited conditions, and systematic means for dealing with mask defects are among the topics discussed. The distortion in Hadamard transform optical instruments caused by moving Masks, incorrect mask alignment, missing measurements, and diffraction is analyzed and techniques for reducing or eliminating this distortion are described.

Harwit, M.↗

Systematic errors in Hadamard transform optics

Error sources encountered in Hadamard transform optical instruments are discussed. Such errors are caused by factors including moving masks, incorrect mask alignment, defects in mask fabrication, missing data, drifts in background level, and diffraction. Techniques for error reduction and/or elimination are described for each of the cases considered. It is noted that the errors described occur in singly encoded spectrometers and imagers.

Sloane, N. J. A.↗

Measuring the thickness of plastic films

Optical instrument measures thickness of translucent and transparent sheets in thickness range from 2 to 8 microns by monitoring attenuation of light as it passes through sheet.

Donohoe, K. C.↗