Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Combined optimization of image-gathering optics and image-processing algorithm for edge detection

This paper investigates the relationships between the image-gathering and image-processing systems for minimum mean-squared error estimation of scene characteristics. A stochastic optimization problem is formulated in which the objective is to determine a spatial characteristic of the scene rather than a feature of the already blurred, sampled, and noisy image data. The Wiener filter for the sampled image case is obtained as a special case, where the desired characteristics is scene restoration. Optimal edge detection is investigated. It is shown that the optimal edge detector compensates for the blurring introduced by the image-gathering optics, and, notably, that it is not circularly symmetric. The lack of circular symmetry is largely due to the geometric effects of the sampling lattice used in image acquisition.

Halyo, N.↗

Optically detected magnetic resonance imaging

Optically detected magnetic resonance provides ultrasensitive means to detect and image a small number of electron and nuclear spins, down to the single spin level with nanoscale resolution. Despite the significant recent progress in this field, it has never been combined with the power of pulsed magnetic resonance imaging techniques. Here, we demonstrate how these two methodologies can be integrated using short pulsed magnetic field gradients to spatially encode the sample. This result in what we denote as an 'optically detected magnetic resonance imaging' technique. It offers the advantage that the image is acquired in parallel from all parts of the sample, with well-defined three-dimensional point-spread function, and without any loss of spectroscopic information. In addition, this approach may be used in the future for parallel but yet spatially selective efficient addressing and manipulation of the spins in the sample. Such capabilities are of fundamental importance in the field of quantum spin-based devices and sensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cusp-artifacts in high order Superresolution Optical Fluctuation Imaging

Superresolution optical fluctuation imaging (SOFI) is a simple and affordable super-resolution imaging technique, and attracted a growing community over the past decade. However, the theoretical resolution enhancement of high order SOFI is still not fulfilled. In this study, we identify “cusp artifacts” in high order SOFI images, and show that the high-order cumulants, odd-order moments and balanced-cumulants (bSOFI) are highly vulnerable to cusp artifacts. Our study provides guidelines for developing and screening for fluorescence probes, and improving data acquisition for SOFI. The new insight is important to inspire positive utilization of the cusp artifacts.

47 OTHER INSTRUMENTATION↗

Cusp-artifacts in high order superresolution optical fluctuation imaging

Superresolution optical fluctuation imaging (SOFI) is a simple and affordable super-resolution imaging technique, and attracted a growing community over the past decade. However, the theoretical resolution enhancement of high order SOFI is still not fulfilled. In this study, we identify “cusp artifacts” in high order SOFI images, and show that the high-order cumulants, odd-order moments and balanced-cumulants (bSOFI) are highly vulnerable to cusp artifacts. Our study provides guidelines for developing and screening for fluorescence probes, and improving data acquisition for SOFI. The new insight is important to inspire positive utilization of the cusp artifacts.

47 OTHER INSTRUMENTATION↗

Non-destructive IC defect localization using optical beam-based imaging.

Optical beam failure analysis methods provide unique capabilities to identify and localize defect types that would be difficult or impossible by other methods. by understanding the physics of signal generation, the user gains the insight necessary to optimize technique performance.

42 ENGINEERING↗

DUST IN COMET C/2007 N3 (LULIN)

We report optical imaging, optical and near-infrared polarimetry, and Spitzer mid-infrared spectroscopy of comet C/2007 N3 (Lulin). Polarimetric observations were obtained in R (0.676 {mu}m) at phase angles from 0.{sup 0}44 to 21{sup 0} with simultaneous observations in H (1.65 {mu}m) at 4.{sup 0}0, exploring the negative branch in polarization. Comet C/2007 N3 (Lulin) shows a typical negative polarization in the optical as well as a similar negative branch at near-infrared wavelengths. The 10 {mu}m silicate feature is only weakly in emission and, according to our thermal models, is consistent with emission from a mixture of silicate and carbon material. We argue that large, low-porosity (akin to ballistic particle cluster aggregates), rather absorbing aggregate dust particles best explain both the polarimetric and the mid-infrared spectral energy distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

Utilizing Highly Scattered Light for Intelligence through Aerosols

This communication is the final report for the project Utilizing Highly Scattered Light for Intelligence through Aerosols funded by the Laboratory Directed Research and Development (LDRD) program at Sandia National Laboratories and lasting six months in 2019. Aerosols like fog reduce visibility and cause down-time that for critical systems or operations are unacceptable. Information is lost due to the random scattering and absorption of light by tiny particles. Computational diffuse optical imaging methods show promise for interpreting the light transmitted through fog, enabling sensing and imaging to improve situational awareness at depths 10 times greater than current methods. Developing this capability first requires verification and validation of diffusion models of light propagation in fog. For this reason, analytical models were developed and compared to experimental data captured at the Sandia National Laboratory Fog Chamber facility. A methodology was developed to incorporate the propagation of scattered light through the imaging optics to a pixel array. The diffusion approximation to the radiative transfer equation was found to predict light propagation in fog under the appropriate conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automated inspection of solder joints for surface mount technology

Researchers at NASA/GSFC evaluated various automated inspection systems (AIS) technologies using test boards with known defects in surface mount solder joints. These boards were complex and included almost every type of surface mount device typical of critical assemblies used for space flight applications: X-ray radiography; X-ray laminography; Ultrasonic Imaging; Optical Imaging; Laser Imaging; and Infrared Inspection. Vendors, representative of the different technologies, inspected the test boards with their particular machine. The results of the evaluation showed limitations of AIS. Furthermore, none of the AIS technologies evaluated proved to meet all of the inspection criteria for use in high-reliability applications. It was found that certain inspection systems could supplement but not replace manual inspection for low-volume, high-reliability, surface mount solder joints.

Savage, Robert M.↗

Positron emission tomography and optical tissue imaging

A mobile compact imaging system that combines both PET imaging and optical imaging into a single system which can be located in the operating room (OR) and provides faster feedback to determine if a tumor has been fully resected and if there are adequate surgical margins. While final confirmation is obtained from the pathology lab, such a device can reduce the total time necessary for the procedure and the number of iterations required to achieve satisfactory resection of a tumor with good margins.

47 OTHER INSTRUMENTATION↗

Concept of Operations for OSIRIS-REx Optical Navigation Image Planning

Optical navigation (OpNav) is a critical subsystem of the OSIRIS-REx asteroid sample return mission, which operated in the vicinity of near-Earth asteroid (101955) Bennu from August 2018 through April 2021. A substantial amount of mission resources across multiple subsystems and institutions is required to ensure that the OpNav data are successfully acquired. The KinetX OpNav team, part of the Flight Dynamics System (FDS), is responsible for performing required analysis to develop the OpNav operations plans; requesting, reviewing and verifying the plans; and ultimately using the image data for critical navigation operations. The FDS team, responsible for the mission navigation, is operated by KinetX Aerospace with management and operations support from NASA’s Goddard Space Flight Center. The Science Processing and Operations Center (SPOC), located at the University of Arizona’s Lunar and Planetary Laboratory, is responsible for generating the planning products for all science and most OpNav data. These plans are integrated into the spacecraft sequences, tested, and commanded by the Mission Support Area (MSA) at Lockheed Martin Space. To ensure mission-critical navigation image data are successfully acquired, the plan is developed through a waterfall of planning cycles over the course of 3 months prior to onboard plan execution. During the initial strategic planning for a mission phase, detailed analysis is performed by the OpNav team to conceptualize the concept of operations (ConOps) for image data collection. This phase OpNav Narrative is included along with other strategic planning documents for the key ground segment stakeholders to review and provide feedback. The detailed OpNav plans get defined in the tactical planning cycle, which spans 8 to 3 weeks before the week-long integrated sequence is executed on-board the spacecraft. During the tactical cycle, the initial OpNav Request is submitted along with the science requests, kicking off development of the science and OpNav plans. Once the initial plan is drafted, interfaces are exercised so that the plan can be reviewed and iterated, if necessary. A rigorous schedule is followed by the planning teams during the implementation cycle, spanning the last 18 days before uplink, to ensure all the necessary integration, testing, and reviewing can occur on time. The development of the OpNav planning ConOps, including responsibilities, interfaces, timelines, and procedures, took extensive collaboration across mission elements and institutions. The process was robust throughout the 137 weeks of continuous Optical Navigation Operations at Bennu, which concluded on April 9th, 2021.

Coralie D. Adam↗

Adaptive Optics For Imaging Bright Objects Next To Dim Ones

Adaptive optics used in imaging optical systems, according to proposal, to enhance high-dynamic-range images (images of bright objects next to dim objects). Designed to alter wavefronts to correct for effects of scattering of light from small bumps on imaging optics. Original intended application of concept in advanced camera installed on Hubble Space Telescope for imaging of such phenomena as large planets near stars other than Sun. Also applicable to other high-quality telescopes and cameras.

Shao, Michael↗

From optical to X-ray ghost imaging

Recent advances in ghost imaging techniques and X-ray sources such as synchrotrons and, more recently, X-ray free-electron lasers (XFEL) have made X-ray ghost imaging a growing topic of interest. One specific type of ghost imaging utilizes thermal radiation and the measurement of intensity fluctuation correlation to form a true image without the need of a lens. This technique allows for much higher resolution than traditional X-ray imaging for a mesoscopic or even a microscopic object. In addition to this benefit of not requiring a lens, a surprising experiment has shown that, when set up correctly, this type of ghost imaging can provide clear images through the measurement of intensity fluctuation correlation when traditional images through measurements of intensity are blurred due to optical turbulence and vibrations. This turbulence-free technique will help maintain the high resolution of X-ray ghost imaging. How is an image formed from fluctuations in light? And what makes it turbulence-free? Using the concept of two-photon interference, this article provides an introduction to these fundamentally interesting concepts and X-ray ghost imaging.

ghost imaging↗

SU-E-T-296: Dosimetric Analysis of Small Animal Image-Guided Irradiator Using High Resolution Optical CT Imaging of 3D Dosimeters

Purpose: To verify the dosimetric characteristics of a small animal image-guided irradiator using a high-resolution of optical CT imaging of 3D dosimeters. Methods: PRESAEGE 3D dosimeters were used to determine dosimetric characteristics of a small animal image-guided irradiator and compared with EBT2 films. Cylindrical PRESAGE dosimeters with 7cm height and 6cm diameter were placed along the central axis of the beam. The films were positioned between 6×6cm{sup 2} cubed plastic water phantoms perpendicular to the beam direction with multiple depths. PRESAGE dosimeters and EBT2 films were then irradiated with the irradiator beams at 220kVp and 13mA. Each of irradiated PRESAGE dosimeters named PA1, PA2, PB1, and PB2, was independently scanned using a high-resolution single laser beam optical CT scanner. The transverse images were reconstructed with a 0.1mm high-resolution pixel. A commercial Epson Expression 10000XL flatbed scanner was used for readout of irradiated EBT2 films at a 0.4mm pixel resolution. PDD curves and beam profiles were measured for the irradiated PRESAGE dosimeters and EBT2 films. Results: The PDD agreements between the irradiated PRESAGE dosimeter PA1, PA2, PB1, PB2 and the EB2 films were 1.7, 2.3, 1.9, and 1.9% for the multiple depths at 1, 5, 10, 15, 20, 30, 40 and 50mm, respectively. The FWHM measurements for each PRESAEGE dosimeter and film agreed with 0.5, 1.1, 0.4, and 1.7%, respectively, at 30mm depth. Both PDD and FWHM measurements for the PRESAGE dosimeters and the films agreed overall within 2%. The 20%–80% penumbral widths of each PRESAGE dosimeter and the film at a given depth were respectively found to be 0.97, 0.91, 0.79, 0.88, and 0.37mm. Conclusion: Dosimetric characteristics of a small animal image-guided irradiator have been demonstrated with the measurements of PRESAGE dosimeter and EB2 film. With the high resolution and accuracy obtained from this 3D dosimetry system, precise targeting small animal irradiation can be achieved.

60 APPLIED LIFE SCIENCES↗