Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Nonequivalent Atomic Vibrations at Interfaces in a Polar Superlattice

In heterostructures made from polar materials, e.g., AlN–GaN–AlN, the nonequivalence of the two interfaces is long recognized as a critical aspect of their electronic properties; in that, they host different 2D carrier gases. Interfaces play an important role in the vibrational properties of materials, where interface states enhance thermal conductivity and can generate unique infrared-optical activity. The nonequivalence of the corresponding interface atomic vibrations, however, is not investigated so far due to a lack of experimental techniques with both high spatial and high spectral resolution. Herein, the nonequivalence of AlN–(Al 0.65 Ga 0.35 )N and (Al 0.65 Ga 0.35 )N–AlN interface vibrations is experimentally demonstrated using monochromated electron energy-loss spectroscopy in the scanning transmission electron microscope (STEM-EELS) and density-functional-theory (DFT) calculations are employed to gain insights in the physical origins of observations. It is demonstrated that STEM-EELS possesses sensitivity to the displacement vector of the vibrational modes as well as the frequency, which is as critical to understanding vibrations as polarization in optical spectroscopies. The combination enables direct mapping of the nonequivalent interface phonons between materials with different phonon polarizations. Furthermore, the results demonstrate the capacity to carefully assess the vibrational properties of complex heterostructures where interface states dominate the functional properties.

36 MATERIALS SCIENCE↗

X-ray near-field multi-slice ptychography for in-situ imaging

Abstract In-situ imaging of chemical reactions can provide valuable insight into nanoparticle growth and structural evolution. Hard X-ray imaging is an excellent tool for this purpose, as it combines high spatial resolution with high penetration depth, allowing for realistic reaction environments. While far-field ptychography is a well-established method at synchrotron radiation sources, its near-field analog has received less attention. In this work we show that near-field multi-slice ptychography is a competitive method for high-resolution in-situ imaging by studying the formation of gold nanocages via galvanic replacement. Our work extends near-field X-ray ptychography to sub-50 nm spatial resolution by using multilayer Laue lenses. These high numerical aperture optics enable to distinguish sample layers that are separated by less than 100 µm by multi-slicing techniques.

Science & Technology - Other Topics↗

Single-particle detection of enhanced polarizability in Au-decorated semiconducting nanorods via scanning dielectric microscopy

Hybrid nanostructures that combine semiconducting and metallic components offer great potential for photothermal therapy, optoelectronics, and sensing, by integrating tunable optical properties with enhanced light absorption and charge transport. Boosting the integrated performance of these hybrid systems demands techniques capable of probing local variations of the physical properties inaccessible to bulk analysis. Here, we report the single-particle dielectric characterization of hybrid, semiconducting bismuth sulfide (Bi 2 S 3 ) nanorods (NR) decorated with metallic Au nanoparticles (NP), employing scanning dielectric microscopy, which uses electrostatic force microscopy in combination with finite-element numerical simulations. We reveal a pronounced enhancement in the local dielectric response of Bi2S3 upon Au decoration, attributed to interfacial polarization and electron transfer from Au to the Bi 2 S 3 matrix, thus suggesting a enhanced metallic-like polarizability at the single-particle level. Numerical simulations show that the response is dominated by the vertical component of the permittivity and that the decorating metallic Au NP produce only moderate shielding of the semiconductor Bi 2 S 3 NR core, indicating that the large increase in the dielectric response originates primarily from intrinsic modifications within the NR. Overall, these findings provide direct insight into structure–property relationships at the single-particle level, supporting the rational design of advanced hybrid nanostructures with tailored electronic functionalities.

36 MATERIALS SCIENCE↗

Dynamical correlations and nonequilibrium sum rules in photodoped Hubbard ladders

Using matrix product state techniques we study the nonequilibrium dynamical response of the half-filled Hubbard ladder when subject to an optical pump. Optical pumping offers a way of producing and manipulating new strongly correlated phenomena by suppressing existing magnetic correlations. The ladder allows the effects of pump directionality to be investigated, and compared to a single chain it has strong spin-charge coupling and a fully gapped excitation spectrum, promising different nonequilibrium physics. We compute time-dependent correlations, including the nonequilibrium dynamical structure factors for spin and charge. By deriving a combined spin-charge sum rule that applies both in and out-of-equilibrium, we show that spectral weight is pumped directly from the antiferromagnetic spin response into a low energy 𝜔 ∼ 0 charge response below the Mott gap. The transfer of weight is pump direction dependent: pumping directed along the legs disrupts magnetic correlations more than pumping in the rung-direction, even if the post-pump energy density is similar. The charge correlation length is dramatically enhanced by the pump, whilst the spin correlations are most strongly suppressed at nearest- and next-nearest-neighbor spacings. After the pump the system is in a nonthermal correlated metallic state, with gapless charge excitations and approximately equal spin and charge correlation lengths, emphasizing the importance of treating these degrees of freedom on an equal footing in nonequilibrium systems.

36 MATERIALS SCIENCE↗

ADRIANO2 Calorimeter Performance from 2022 Test Beams

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration. The ADRIANO2 Calorimeter Prototype consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. Čerenkov light from the lead glass are exploited to for high resolution timing measurements, while high granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle detection for REDTOP as it is crucial for a calorimeter to detect the decay products of eta/eta-prime mesons. Measurements were collected on ADRIANO2 between February to December 2022 to evaluate the detector performance at Fermilab’s Test Beam Facility. The key metrics extracted from my analysis are the detector’s efficiency for various tile configuration and light-yield which will then be used as parameters for an upgraded REDTOP monte-carlo simulation campaign. An in-depth analysis of ADRIANO2 performance are detailed in this presentation.

43 PARTICLE ACCELERATORS↗

Multiplexing Focusing Analyzer for Efficient Stress-Strain Measurements

Statement of the problem or situation that is being addressed. Although thermal and cold neutron scattering is widely used and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed. We propose to design and demonstrate novel diffractive optical device, which will enable very efficient residual stress neutron diffractometers. The proposed device will be a multi-foil analyzer, where each foil is constructed of focusing bent single crystals of Si. Such device will enable polychromatic residual stress neutron diffraction. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast measurements for determining residual stress tensors, raster large samples or screen multiple samples. Commercial Applications and Other Benefits The outcome of this project would be the demonstration of commercial devices, novel neutron optical components, which could be utilized to improve the performance of existing instruments or build novel neutron scattering instruments at DOE neutron facilities and commercial laboratory neutron sources. These new devices will widen the scope of research conducted using neutrons and enable measurements not feasible at present. Summary for Members of Congress Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Industrial deposition of wavelength-shifting films for liquid argon photon detection systems

The Deep Underground Neutrino Experiment (DUNE) Phase-II Far Detector is considering an approximately 2000 m 2 photon detection system to achieve a target mean light yield of 180 PE/MeV. Meeting this requirement demands scalable, cost-effective, and high-quality wavelength-shifter (WLS) coatings capable of converting 127 nm liquid-argon scintillation light into visible photons with controlled and reproducible optical performance. We report on the successful realization of an industrial physical vapor deposition (PVD) process forp-terphenyl (pTP) coatings, adapted from vacuum deposition techniques developed for OLED display manufacturing, to produce uniform WLS layers on large-area inorganic substrates, a task traditionally challenged by adhesion and uniformity issues at organic-inorganic interfaces. Surface characterization by profilometry and spectroscopic measurements demonstrates edge-region thickness variation below 10% and emission spectra consistent with high-quality pTP reference samples. The industrial process demonstrates reproducibility, scalability, and significantly reduced production time compared to laboratory-based methods, while maintaining optical characteristics consistent with established pTP reference samples. These results establish a viable pathway for mass production of high-performance pTP coatings for DUNE FD3 and future neutrino experiments, from a coating manufacturing and process standpoint. Detector-level performance validation, including quantitative VUV conversion efficiency measurements at 127 nm, is identified as future work.

47 OTHER INSTRUMENTATION↗

Three phase spectral interferometry for recording high dynamic range optical waveforms with <1 ps resolution over >2 ns records applied to closed-loop pulse shaping

Herein we demonstrate, to our knowledge, a novel spectral interferometry technique that simultaneously captures three spectral interferograms of a signal waveform with a reference pulse. The measured performance is robust to nonidealities and ambient drifts by implementing a precisely calibrated 3 × 3 polarization maintaining (PM) splitter that provides three phase shift differences nominally spaced 120° apart. The system can achieve long record length by implementing three, high resolution, virtually imaged phase array (VIPA) spectrometers. Here, we experimentally implement this technique and demonstrate the measurement of waveforms with >2ns of record while maintaining <1ps resolution.

42 ENGINEERING↗

Generation of Neutron Airy Beams

The Airy wave packet is a solution to the potential-free Schrödinger equation that exhibits remarkable properties such as self-acceleration, nondiffraction, and self-healing. Although Airy beams are now routinely realized with electromagnetic waves and electrons, the implementation with neutrons has remained elusive due to small transverse coherence lengths, low fluence rates, and the absence of neutron lenses. In this Letter, we overcome these challenges through a holographic approach and present the first experimental demonstration of neutron Airy beams. The presented techniques pave the way for fundamental physics studies with Airy beams of nonelementary particles, the development of novel neutron optics components, and the realization of neutron Airy-vortex beams. Published by the American Physical Society 2025

Sarenac, Dusan (ORCID:0000000185753367)↗

Detection of Critical Surface Features in PTLs and GDLs for Improved Device Performance and Manufacturing Reliability

High points, or features that protrude above the surface of the material, on porous transport layers (PTLs) and gas diffusion layers (GDLs) can be critical features that may affect the manufacturing process and the performance of the device containing the feature. High points on PTLs and GDLs may stress the membrane of a polymer electrolyte membrane (PEM) during lamination and cell operation of a PEM electrolyzer or fuel cell. Additionally, high points on GDLs may impact the reliability of the manufacturing process. Thus, understanding these critical features and developing procedures to detect them are a key part of developing quality control techniques for PTLs and GDLs. This work evaluates the effectiveness of the Keyence VR6200 benchtop-scale structured light optical profilometer for detection of surface protrusions on PTLs and GDLs. Standard testing procedures for detecting and measuring high points were created for use on both material types. These procedures were evaluated using Gage Repeatability and Reproducibility (Gage R&R), where the repeatability, reproducibility, and effectiveness of the system to detect and measure high points were quantified. We have shown with high statistical power that the system is very effective in detection and measurement of high points, with Gage R&R contributions measured to be 2.2% and 3.6% for PTLs and GDLs, respectively.

36 MATERIALS SCIENCE↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

An experimental and computational investigation of the structure and spectroscopic signatures of α -UO 3

α-UO 3 is a common intermediate compound found in the nuclear fuel cycle, yet the exact crystal structure of this material has long been debated. Inconsistent computational and experimental data in previous works has led to varying conclusions between authors. Furthermore, to ensure the validity of our results in this work, the structural and spectroscopic signatures of pure phase α-UO 3 are investigated using powder X-ray diffraction and optical vibrational spectroscopy (infrared and Raman). Rietveld refinement of powder X-ray diffraction data on pure phase α-UO 3 collected in this work allows us to propose an alteration to the currently accepted C2mm structure (a = 3.9705 Å, b = 6.8553 Å, c = 4.15955 Å, α = β = γ = 90°) for α-UO 3 with no uranyl [UO 2 2+ ] bonds. Raman spectra collected using two excitation wavelengths (two instruments using 532 nm and one 785 nm) are presented, and differences with recently published results are discussed. Infrared spectra from two instruments used here agree well with recently published results, but the spectral range encompassed in our data extends past what has been reported with modern techniques. Additionally, we provide tentative vibrational mode assignments based on density functional perturbation theory calculations and resulting phonon eigenvector visualizations. Unexpected features in the optical vibrational spectra of α-UO 3 are explained by unique features in the structure we present.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Heat affected zone liquation cracking evaluation on FeMnAl alloys

FeMnAl steels are currently generating a lot of interest with potential applications for structural parts in armored vehicles due to their lower density and outstanding mechanical properties. Despite the extensive mechanical performance and heat treatment exploration of this alloy class, further weldability investigation is required for future large-scale deployment. In the present study, the liquation cracking of four heats of cast FeMnAl alloys was investigated by the spot-Varestraint technique. The study focuses primarily on the effect of the major elements of the FeMnAl system: C, Mn and Al. Optical and electron microscopy were employed to investigate the microstructural features, and CALPHAD was employed to aid the discussion regarding the alloy’s composition differences and their effect on the liquation cracking susceptibility. The study was able to identify that compositions with the higher Mn, C, and lower Al presented the highest liquation cracking susceptibility. Conversely, composition presenting lower Mn, C, and Al showed the most resistant behavior. Furthermore, lower Al content promoted a fully-γ microstructure at low temperatures, which encouraged the appearance of longer cracks as a γ-matrix is more susceptible to HAZ cracking than a fully ferritic (α) or duplex (α + γ) microstructure.

36 MATERIALS SCIENCE↗

Robust Quantum Control via Multipath Interference for Thousandfold Phase Amplification in a Resonant Atom Interferometer

We introduce a novel technique for enhancing the robustness of light-pulse atom interferometers against the pulse infidelities that typically limit their sensitivities. The technique uses quantum optimal control to favorably harness the multipath interference of the stray trajectories produced by imperfect atom-optics operations. We apply this method to a resonant atom interferometer and achieve thousandfold phase amplification, representing a 50-fold improvement over the performance observed without optimized control. Moreover, we find that spurious interference can arise from the interplay of spontaneous emission and many-pulse sequences and demonstrate optimization strategies to mitigate this effect. Given the ubiquity of spontaneous emission in quantum systems, these results may be valuable for improving the performance of a diverse array of quantum sensors. We anticipate our findings will significantly benefit the performance of matter-wave interferometers for a variety of applications, including dark matter, dark energy, and gravitational wave detection.

47 OTHER INSTRUMENTATION↗

Circularly Polarized Attosecond Pulses Enabled by an Azimuthal Phase and Polarization Grating

High-harmonic generation (HHG) is an extreme nonlinear optical process that can map the properties of an infrared driving laser beam onto short wavelength attosecond pulse trains. However, current techniques for generating circularly polarized high harmonics for probing magnetic materials and chiral systems have limitations: two-color collinear counter-rotating driving lasers result in a low cutoff photon energy, while single-color non-collinear counter-rotating schemes suffer from low conversion efficiency. In this work, we generate circularly polarized attosecond pulse trains by using a structured laser driver which has a rotating polarization and phase grating along the azimuthal coordinate. Furthermore, our experimental and numerical results demonstrate the production of left and right circularly polarized harmonics, which naturally separate upon propagation. Our approach uses a single laser color in a collinear geometry, that can be scaled for high efficiency. Simulations show this scheme can extend into the soft x-ray region when driven by mid-infrared driving lasers, while preserving the same high phase-matching cutoff photon energy as for linearly-polarized high harmonics.

attosecond science↗

High-Power Clock Laser Spectrally Tailored for High-Fidelity Quantum State Engineering

Highly frequency-stable lasers are ubiquitous tools for optical-frequency metrology, precision interferometry, and quantum information science. While making a universally applicable laser is unrealistic, spectral noise can be tailored for specific applications. Here we report a high-power 698-nm clock laser with a maximum output of 4W and minimized frequency noise up to a few kHz Fourier frequency, together with long-term instability of 3.5 × 10 −17 at one to thousands of seconds. The laser-frequency noise is precisely characterized with atom-based spectral analysis that employs a pulse sequence designed to suppress sensitivity to intensity noise. This method provides universally applicable tunability of the spectral response and analysis of quantum sensors over a wide frequency range. With the optimized laser system characterized by this technique, we achieve an average single-qubit Clifford gate fidelity of up to 𝐹$^2_1$ = 0.999⁢64⁢(3) when simultaneously driving 3000 optical qubits with a homogeneous Rabi frequency ranging from 10 Hz to 1 kHz. This result represents the highest single optical-qubit-gate fidelity for a large number of atoms.

atomic gases↗

High-Q cavity interface for color centers in thin film diamond

Quantum information technology offers the potential to realize unprecedented computational resources via secure channels distributing entanglement between quantum computers. Diamond, as a host to optically-accessible spin qubits, is a leading platform to realize quantum memory nodes needed to extend such quantum links. Photonic crystal (PhC) cavities enhance light-matter interaction and are essential for an efficient interface between spins and photons that are used to store and communicate quantum information respectively. Here, we demonstrate one- and two-dimensional PhC cavities fabricated in thin-film diamonds, featuring quality factors (Q) of 1.8 × 10 5 and 1.6 × 10 5 , respectively, the highest Qs for visible PhC cavities realized in any material. Importantly, our fabrication process is simple and high-yield, based on conventional planar fabrication techniques, in contrast to the previous with complex undercut processes. We also demonstrate fiber-coupled 1D PhC cavities with high photon extraction efficiency, and optical coupling between a single SiV center and such a cavity at 4 K achieving a Purcell factor of 18. The demonstrated photonic platform may fundamentally improve the performance and scalability of quantum nodes and expedite the development of related technologies.

97 MATHEMATICS AND COMPUTING↗