Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

MOD: An Instrument for the 2005 Mars Explorer Program HEDS Payload

The Mars Organic Detector (MOD) was recently selected for the definition phase of the HEDS '05 (originally scheduled for '03) lander instrument package for fundamental biology and in situ resource utilization. MOD is designed to detect organic compounds in rock and soil samples directly on the surface of Mars in order to assess the biological potential of the planet. In addition, a MOD Tunable Diode Laser Spectrometer (TDLS) will provide information on desorption and decomposition temperatures, as well as the release rates and quantities of water and carbon dioxide that can be liberated from regolith samples, thereby providing the parameters needed for the design of systems for the future large-scale in situ extraction of valuable consumable resources. A MOD TDLS will also measure the atmospheric water and carbon dioxide content, as well as the atmospheric carbon dioxide isotopic composition, in order to determine whether there is an isotopic offset between atmospheric and surface carbon.

Bada, J. L.↗

Interferometry in the Era of Very Large Telescopes

Research in modern stellar interferometry has focused primarily on ground-based observatories, with very long baselines or large apertures, that have benefited from recent advances in fringe tracking, phase reconstruction, adaptive optics, guided optics, and modern detectors. As one example, a great deal of effort has been put into development of ground-based nulling interferometers. The nulling technique is the sparse aperture equivalent of conventional coronography used in filled aperture telescopes. In this mode the stellar light itself is suppressed by a destructive fringe, effectively enhancing the contrast of the circumstellar material located near the star. Nulling interferometry has helped to advance our understanding of the astrophysics of many distant objects by providing the spatial resolution necessary to localize the various faint emission sources near bright objects. We illustrate the current capabilities of this technique by describing the first scientific results from the Keck Interferometer Nuller that combines the light from the two largest optical telescopes in the world including new, unpublished measurements of exozodiacal dust disks. We discuss prospects in the near future for interferometry in general, the capabilities of secondary masking interferometry on very large telescopes, and of nulling interferometry using outriggers on very large telescopes. We discuss future development of a simplified space-borne NIR nulling architecture, the Fourier-Kelvin Stellar Interferometer, capable of detecting and characterizing an Earth twin in the near future and how such a mission would benefit from the optical wavelength coverage offered by large, ground-based instruments.

Barry, Richard K.↗

X-Ray Diffractive Optics

X-ray optics were fabricated with the capability of imaging solar x-ray sources with better than 0.1 arcsecond angular resolution, over an order of magnitude finer than is currently possible. Such images would provide a new window into the little-understood energy release and particle acceleration regions in solar flares. They constitute one of the most promising ways to probe these regions in the solar atmosphere with the sensitivity and angular resolution needed to better understand the physical processes involved. A circular slit structure with widths as fine as 0.85 micron etched in a silicon wafer 8 microns thick forms a phase zone plate version of a Fresnel lens capable of focusing approx. =.6 keV x-rays. The focal length of the 3-cm diameter lenses is 100 microns, and the angular resolution capability is better than 0.1 arcsecond. Such phase zone plates were fabricated in Goddard fs Detector Development Lab. (DDL) and tested at the Goddard 600-microns x-ray test facility. The test data verified that the desired angular resolution and throughput efficiency were achieved.

Dennis, Brian↗

Estimation of Orbital Neutron Detector Spatial Resolution by Systematic Shifting of Differential Topographic Masks

We present a method and preliminary results related to determining the spatial resolution of orbital neutron detectors using epithermal maps and differential topographic masks. Our technique is similar to coded aperture imaging methods for optimizing photonic signals in telescopes [I]. In that approach photon masks with known spatial patterns in a telescope aperature are used to systematically restrict incoming photons which minimizes interference and enhances photon signal to noise. Three orbital neutron detector systems with different stated spatial resolutions are evaluated. The differing spatial resolutions arise due different orbital altitudes and the use of neutron collimation techniques. 1) The uncollimated Lunar Prospector Neutron Spectrometer (LPNS) system has spatial resolution of 45km FWHM from approx. 30km altitude mission phase [2]. The Lunar Rennaissance Orbiter (LRO) Lunar Exploration Neutron Detector (LEND) with two detectors at 50km altitude evaluated here: 2) the collimated 10km FWHM spatial resolution detector CSETN and 3) LEND's collimated Sensor for Epithermal Neutrons (SETN). Thus providing two orbital altitudes to study factors of: uncollimated vs collimated and two average altitudes for their effect on fields-of-view.

McClanahan, T. P.↗

Active Control Evaluation for Spacecraft (ACES)

The Air Force goal is to develop vibration control techniques for large flexible spacecraft by addressing sensor, actuator, and control hardware and dynamic testing. The Active Control Evaluation for Spacecraft (ACES) program will address the Air Force goal by looking at two leading control techniques and implementing them on a structural model of a flexible spacecraft under laboratory testing. The first phase in the ACES program is to review and to assess the High Authority Control/Low Authority Control (HAC/LAC) and Filter accomodated Model Error Sensitivity Suppression (FAMESS) control techniques for testing on the modified VCOSS structure. Appropriate sensors and actuators will be available for use with both techniques; locations will be the same for both techniques. The control actuators will be positioned at the midpoint and free end of the structure. The laser source for the optical sensor is mounted on the feed mast. The beam will be reflected from a mirror on the offset antenna onto the detectors mounted above the shaker table bay. The next phase is to develop an analysis simulation with the control algorithms implemented for dynamics verification. The third phase is to convert the control laws into high level computer language and test them in the NASA-MSFC facility. The final phase is to compile all analytical and test results for performance comparisons.

Pearson, J.↗

Robust Timing Synchronization in Aeronautical Mobile Communication Systems

This work details a study of robust synchronization schemes suitable for satellite to mobile aeronautical applications. A new scheme, the Modified Sliding Window Synchronizer (MSWS), is devised and compared with existing schemes, including the traditional Early-Late Gate Synchronizer (ELGS), the Gardner Zero-Crossing Detector (GZCD), and the Sliding Window Synchronizer (SWS). Performance of the synchronization schemes is evaluated by a set of metrics that indicate performance in digital communications systems. The metrics are convergence time, mean square phase error (or root mean-square phase error), lowest SNR for locking, initial frequency offset performance, midstream frequency offset performance, and system complexity. The performance of the synchronizers is evaluated by means of Matlab simulation models. A simulation platform is devised to model the satellite to mobile aeronautical channel, consisting of a Quadrature Phase Shift Keying modulator, an additive white Gaussian noise channel, and a demodulator front end. Simulation results show that the MSWS provides the most robust performance at the cost of system complexity. The GZCD provides a good tradeoff between robustness and system complexity for communication systems that require high symbol rates or low overall system costs. The ELGS has a high system complexity despite its average performance. Overall, the SWS, originally designed for multi-carrier systems, performs very poorly in single-carrier communications systems. Table 5.1 in Section 5 provides a ranking of each of the synchronization schemes in terms of the metrics set forth in Section 4.1. Details of comparison are given in Section 5. Based on the results presented in Table 5, it is safe to say that the most robust synchronization scheme examined in this work is the high-sample-rate Modified Sliding Window Synchronizer. A close second is its low-sample-rate cousin. The tradeoff between complexity and lowest mean-square phase error determines the rankings of the Gardner Zero-Crossing Detector and both versions of the Early-Late Gate Synchronizer. The least robust models are the high and low-sample-rate Sliding Window Synchronizers. Consequently, the recommended replacement synchronizer for NASA's Advanced Air Transportation Technologies mobile aeronautical communications system is the high-sample-rate Modified Sliding Window Synchronizer. By incorporating this synchronizer into their system, NASA can be assured that their system will be operational in extremely adverse conditions. The quick convergence time of the MSWS should allow the use of high-level protocols. However, if NASA feels that reduced system complexity is the most important aspect of their replacement synchronizer, the Gardner Zero-Crossing Detector would be the best choice.

Xiong, Fu-Qin↗

Interferometric phase velocity measurements in the auroral electrojet

A double-probe electric field detector and two spatially separated fixed-bias Langmuir probes were flown on a Taurus-Tomahawk sounding rocket launched from Poker Flat Research Range in March 1982. Interesting wave data have been obtained from about 10s of the downleg portion of the flight during which the rocket passed through the auroral electrojet. Here the electric field receiver and both density fluctuation (delta-n/n) receivers responded to a broad band of turbulence centered at 105 km-altitude and at frequencies generally below 4 kHz. Closer examination of the two delta-n/n turbulent waveforms reveals that they are correlated; from the phase difference between the two signals, the phase velocity of the waves in the rocket reference frame is inferred. The magnitude and direction of the observed phase velocity are consistent either with waves which travel at the ion sound speed or with waves which travel at the electron drift velocity. The observed phase velocity varies by about 50 percent over a 5 km altitude range, an effect which probably results from shear in the zonal neutral wind, although, unfortunately, no simultaneous neutral wind measurements exist to confirm this.

Labelle, J.↗

A 100Mbps coherent optical link demonstration using frequency stabilized solid state lasers

The design, implementation, and performance evaluation of a 100Mbps binary phase shift keying (BPSK) coherent optical link using frequency stabilized solid state lasers is described. In this demonstration, the transmitted data is binary phase modulated at 100Mbps using an external resonant cavity phase modulator. At the receiving end, the signal is detected using a balanced heterodyne detector. An auxiliary frequency tracking loop (FTL) is used to help the initial frequency acquisition before handing over to the carrier phase tracking loop. The FTL is implemented using a delay line discriminator, and the detected frequency error is fed back to the local oscillator laser to close the tracking loop. Phase coherent reception is achieved by synchronizing the carrier phase using a Costas tracking loop. The demonstration showed that a high data rate phase coherent optical link can be implemented using frequency stabilized solid state lasers.

Chen, CHIEN-C.↗

Phase Change Material for Temperature Control of Loop Heat Pipe Compensation Chamber

The compensation chamber (CC) of a loop heat pipe (LHP) requires a stable temperature. In the current technology, the CC is commonly cold biased by exposing it to deep space, and active heater control is used to maintain its temperature stable. Heater power required for a typical LHP with a 300 W heat transport capacity is as much as 25 W. If multiple LHPs are used, heater power requirement could be a bigger issue. Also heater controller or temperature sensor failure could lead to a LHP or mission failure. This paper presents an innovative concept of using phase change material (PCM) for temperature control of LHP CC. Some of the electronics and/or detector assembly waste heat is stored in the PCM and transferred to the LHP CC by constant conductance heat pipes (CCHPs). Phase change of the PCM occurs at a constant temperature and maintains the LHP CC temperature stable. It eliminates heater power and active heater control for the CC. It also increases the reliability of LHP.

Choi, Michael K.↗

A method for unique identification of relativistic /greater than 0.5/ magnetic monopoles with a fast film Cerenkov detector

A magnetic monopole traversing a dielectric medium at a velocity greater than the phase velocity of light in that medium, will give rise to Cerenkov radiation with the electric field tangent to the cone generated by the photon wave propagation vector, and the magnetic field normal to that surface. This is the opposite polarization to that encountered with an electric charge. It is proposed that either by inserting a linearly polarizing layer between the radiator and the photographic emulsion, or by selecting a linearly polarizing material as the radiator, one could directly observe the field polarization by examining the photographic image and thus uniquely identify a magnetic monopole. The ability of the detector is further enhanced by the index of refraction dependence of the Cerenkov output from a magnetic monopole.

Pinsky, L. S.↗

Shuttle GPS R/PA evaluation analysis and performance tradeoff study

Primary responsibility was understanding and analyzing the various GPS receiver functions as they relate to the shuttle environment. These receiver functions included acquisition properties of the sequential detector, acquisition and tracking properties of the various receiver phase locked loops, and the techniques of sequential receiver operation. In addition to these areas, support was provided in the areas of oscillator stability requirements, antenna management, and navigation filter requirements, including preposition aiding.

Booth, R. W. D.↗

Muon content of gamma ray induced EAS from Cygnus X-3

During 1984 the Leeds group (Lambert et al, OG 2,1-6) have observed emission above 5 times 10 to the 14th power eV in July, September and October at phi approximately 0.6. These observations were made with an array which included the Nottingham 10 sq m muon detector. A search for muons in events at the phase peak and off source has yielded the following results: (1) for 42 on source events we find an average muon density of 0.63 muons m(-2) at a mean core distance Bar R = 32 m and mean primary energy approximately 25 times 10 to the 15th power eV; (2) for 21 off source events average muon density = 1.6 m(-2), Bar R = 32 m with mean primary energy approximately 2.0 x 10 to the 15th power eV; (3) for 11 of the 42 on source events, zero muons were recorded in the 10 sq ms. For these events Bar R = 41 m and mean primary energy approximately 1.5 x 10 to the 15th power eV; (4) for 8 of the 21 off source events, zero muons were recorded in the 10 sq ms. For these events Bar R = 37 m and mean primary energy approximately 1.5 times 10 to the 15th power eV. For all the events the mean zenith angle was approximately 16 deg. A more detailed comparison of on source and further off source events will be presented.

Blake, P. R.↗

Acquisition of a High Resolution Field Emission Scanning Electron Microscope for the Analysis of Returned Samples

This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to support our analytical facilities for extraterrestrial samples. After evaluating several instruments, we purchased a JEOL 6500F thermal field emission SEM with the following analytical accessories: EDAX energy-dispersive x-ray analysis system with fully automated control of instrument and sample stage; EDAX LEXS wavelength-dispersive x-ray spectrometer for high sensitivity light-element analysis; EDAX/TSL electron backscatter diffraction (EBSD) system with software for phase identification and crystal orientation mapping; Robinson backscatter electron detector; and an in situ micro-manipulator (Kleindiek). The total price was $550,000 (with $150,000 of the purchase supported by Carnegie institution matching funds). The microscope was delivered in October 2002, and most of the analytical accessories were installed by January 2003. With the exception of the wavelength spectrometer (which has been undergoing design changes) everything is working well and the SEM is in routine use in our laboratory.

Nittler, Larry R.↗

The Swift Gamma Ray Burst Mission

Swift is an international mission managed by NASA as part of its MIDEX program. It is a multiwavelength transient observatory for GRB astronomy that will launch in 2004. The goals of the mission are to determine the origin of GRBs and their afterglows and use bursts to probe the early Universe. A wide field gamma-ray camera will detect more than a hundred GRBs per year to 2-5 times fainter than BATSE. Sensitive narrow-field X-ray, and UV/optical telescopes will be pointed at the burst location in 20 to 75 sec by an autonomously controlled 'swift' spacecraft. For each burst, arcsec positions will be determined and optical/UV/x-ray/gamma-ray spectrophotometry performed. Measurements of redshift will be made for many of the bursts. The instrumentation is a combination of superb existing flight-spare hardware and design from XMM and Spectrum-X/JET-X contributed by collaborators in the UK and Italy and development of a coded-aperture camera with a large-area (approx. 0.5 square meter) CdZnTe detector array. The instruments have now completed their fabrication phase and are integrated on the observatory for final testing. Key components of the mission are vigorous follow-up and outreach programs to engage the astronomical community and public in Swift. The talk will describe the mission and its status and give a summary of our plans for GRB operations.

Gehrels, Neil↗

Heterodyne arrays at submillimeter wavelengths

Heterodyne receivers, which down-convert radio frequency (RF) signals to intermediate frequency (IF) signals - preserving the amplitude and phase information of the incoming radiation, are generally the detector of choice for high resolution spectroscopic studies in astrophysics and planetary remote sensing.

submillimeter wavelength↗

Laboratory Instruments Available to Support Space Station Researchers at Marshall Space Flight Center

A number of research instruments are available at NASA's Marshall Space Flight Center (MSFC) to support ISS researchers and their investigations. These modern analytical tools yield valuable and sometimes new informative resulting from sample characterization. Instruments include modern scanning electron microscopes equipped with field emission guns providing analytical capabilities that include angstron-level image resolution of dry, wet and biological samples. These microscopes are also equipped with silicon drift X-ray detectors (SDD) for fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations in crystalline alloys. Sample chambers admit large samples, provide variable pressures for wet samples, and quantitative analysis software to determine phase relations. Advances in solid-state electronics have also facilitated improvements for surface chemical analysis that are successfully employed to analyze metallic materials and alloys, ceramics, slags, and organic polymers. Another analytical capability at MSFC is a mganetic sector Secondary Ion Mass Spectroscopy (SIMS) that quantitatively determines and maps light elements such as hydrogen, lithium, and boron along with their isotopes, identifies and quantifies very low level impurities even at parts per billion (ppb) levels. Still other methods available at MSFC include X-ray photo-electron spectroscopy (XPS) that can determine oxidation states of elements as well as identify polymers and measure film thicknesses on coated materials, Scanning Auger electron spectroscopy (SAM) which combines surface sensitivity, spatial lateral resolution (approximately 20 nm), and depth profiling capabilities to describe elemental compositions in near surface regions and even the chemical state of analyzed atoms. Conventional Transmission Electron Microscope (TEM) for observing internal microstructures at very high magnifications and the Electron Probe Micro-analyzer (EPMA) for very precise microanalysis are available as needed by the researcher. Space Station researchers are invited to work with MSFC in analyzing their samples using these techniques.

Panda, Binayak↗

Simple Parametric Model for Intensity Calibration of Cassini Composite Infrared Spectrometer Data

Accurate intensity calibration of a linear Fourier-transform spectrometer typically requires the unknown science target and the two calibration targets to be acquired under identical conditions. We present a simple model suitable for vector calibration that enables accurate calibration via adjustments of measured spectral amplitudes and phases when these three targets are recorded at different detector or optics temperatures. Our model makes calibration more accurate both by minimizing biases due to changing instrument temperatures that are always present at some level and by decreasing estimate variance through incorporating larger averages of science and calibration interferogram scans.

Brasunas, J.↗

A Fast Evaluation of PDA Experimental Parameters Using Mie Scattering to Enhance the Measurement Accuracy of Droplet Size Distributions

The Phase Doppler technique (PDA) and its implementation generally relies on a geometric optics formulation for light scattering to estimate drop sizes from the measured phase differences between Doppler signals from two or more detectors. Although this limits experimental PDA scattering geometries to those where only one component of the geometric scatter is dominant, the calculations are relatively simple. This TM describes a fast method to evaluate PDA experimental parameters analytically using Mie scattering that provides a performance estimate of all possible configurations. The best configurations are fully tested using a Monte Carlo simulation to obtain a more accurate capability estimate for each one.

PDA↗