Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIEZOELECTRICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Progress Toward Molten Salt Reactor Heat Exchanger On-Line Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

EGS Collab Experiment 2: Continuous Active Source Seismic Monitoring (CASSM)

The dataset contains continuous active-source seismic monitoring (CASSM) data collected during EGS Collab Experiment 2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to investigate enhanced geothermal systems through high-pressure fluid injections at depths of 1200-1500 meters. The seismic monitoring system included 16 three-component piezoelectric accelerometers and 24 hydrophones installed in boreholes around the injection zones, recording signals from piezoelectric seismic sources. Data were acquired using both continuous and triggered recording systems, with sampling rates of up to 100 kHz. The raw data are organized by timestamps and stored in .dat format, with accompanying log files. Calibration certificates for selected accelerometers are provided to aid in correcting sensor responses, though users are advised to consider possible effects of enclosures and installation on sensor performance. Users are strongly advised to consult the accompanying report, which outlines the experimental setup, data acquisition, sensor specifications, and recording systems.

15 GEOTHERMAL ENERGY↗

Determining the oxidation stability of SnSe under atmospheric exposure

Abstract Understanding surface stability becomes critical as 2D materials like SnSe are developed for piezoelectric and optical applications. SnSe thin films deposited by molecular beam epitaxy showed no structural changes after a two-year exposure to atmosphere, as confirmed by X-ray diffraction and Raman spectroscopy. X-ray photoelectron spectroscopy and reflectivity show a stable 3.5 nm surface oxide layer, indicating a self-arresting oxidative process. Resistivity measurements show an electrical response dominated by SnSe post-exposure. This work shows that SnSe films can be used in ambient conditions with minimal risk of long-term degradation, which is critical for the development of piezoelectric or photovoltaic devices. Graphical Abstract

Chin, Jonathan R. (ORCID:0000000273205678)↗

Microphonics Studies at STC in Fermilab

The spoke test cryostat is used to qualify the 325 MHz single spoke resonators at Fermilab (FNAL). During these tests a large detuning on the cavity was observed. The data acquisition for continuous captures were based on measurements from the piezoelectric actuators. A com-parison of the cavity vibrations measured with RF signal from the cavity and piezoelectric actuator signals are shown. The effects of microphonics on the cavity are discussed.

43 PARTICLE ACCELERATORS↗

Mesoscale Design of Magnetoelectric Heterostructures and Nanocomposites

Multiferroic materials have a coexistence of at least two ferroic orders. The coupling interaction between the different order parameters can produce new phenomena, such as the magnetoelectric (ME) effect. The ME response is the appearance of an electric polarization P upon applying a magnetic field H, and/or vice versa. Magnetoelectricity has been observed as an intrinsic effect in some natural materials at low temperature; however, such single phase materials suffer from extremely weak ME exchange. Better alternatives are two-phase composites consisting of magnetostrictive and piezoelectric phases, which have been shown to have large ME coefficients. Said composites exploit a unique product ME tensor property that depends upon the individual strictions of the piezoelectric and magnetostrictive phases, the elastic stiffness and integrity of the interphase interfaces, the phase distribution and the dimensionality of its connectivity, and any elastic constraint; amongst other things. This research program between D. Viehland PI and S.Priya at Virginia Tech investigated the mesoscale physics and chemistry of such two-phase ME heterostructures. The results of the proposed research are relevant to new generations of multifunctional materials involving heterogeneous components. How the product ME property be optimized? The answers lies with the interphase-interfaces, where the atomic layers coordinate stress transfer from one phase to another. It was the primary goal of this research program to discover such fundamental relationship for two phase ME heterostructures and nanocomposites. This research program integrated all the components required to fully investigate the ME phenomenon: starting from synthesis of nanomaterials with diversified interfacial characteristics; to full electrical, magnetic, and structural characterizations.

36 MATERIALS SCIENCE↗

Final Report on Characterization of Irradiated Sensors and Coupling Adhesive Bonds

This report summarizes characterization via scanning/transmission electron microscopy of the microstructures of the unirradiated and irradiated piezoelectric ultrasonic sensor/aluminum substrate assemblies using four commercially available inorganic coupling adhesives to bond two types of piezoelectric crystals to the substrates. The sample assemblies were irradiated in the PULSTAR reactor at NC State University and ultrasonic data was collected in-situ. ORNL LAMDA Laboratory capabilities were utilized to perform pre- and post-irradiation examination of the sensor assemblies. This document summarizes the PIE performed at the ORNL LAMDA laboratory. The results of the PIE described in this report are consistent with the ultrasonic data collected during irradiation – in particular, high temperature epoxy adhesive seemed to provide the best coupling as compared to the refractory ceramic adhesives. It was determined that the quality of the sensor-adhesive-substrates governed the ultrasonic performance of the sensors. It was also apparent that irradiation did not significantly affect bond quality, which is also supported by the ultrasonic data collected during irradiation. A more comprehensive DOE NSUF Final Report including details of materials selection, sample fabrication, initial ultrasonic testing, irradiation and in-situ ultrasonic testing, positron annihilation lifetime spectroscopy and doppler broadening spectroscopy performed at EPRI and NC State University will be published at the conclusion of the project.

36 MATERIALS SCIENCE↗

A Theoretical Analysis on the Dynamic Behavior and Electromechanical Response of PZT

Piezoelectric materials are used as a power source in stockpile components for safety and reliability assurances. The objective of this project is to gain insights into the fundamental pressure-induced behavior and electromechanical response of lead zirconate titanate (PZT). Specifically, to establish the basis for an accurate, physics-based material model for robust model-based design to rapidly optimize PZT-based materials and components for performance studies. Established ab-initio methods are used to interrogate and understand the dynamic behavior of PZT as a function of composition (50/50, 65/35, 80/20, 95/5) and dopants (La, Nb) to overcome the costly and time-consuming experimental methodologies. New cold curves for pure and doped single-crystal PZT are obtained as the reference equation-of-state (EOS). A negligible change in the pressure responses was observed for the systems and strains studied. Dielectric and piezoelectric responses of pure and doped single-crystal PZT were also calculated as a function of pressure. For undoped PZT, there is a clear and orderly pressure and composition dependence. For doped PZT, there is a significant increase in the responses, but the behavior is very disordered and inconclusive.

36 MATERIALS SCIENCE↗

Vertical Etching of Scandium Aluminum Nitride Thin Films Using TMAH Solution

A wide bandgap, an enhanced piezoelectric coefficient, and low dielectric permittivity are some of the outstanding properties that have made Sc x Al 1-x N a promising material in numerous MEMS and optoelectronics applications. One of the substantial challenges of fabricating Sc x Al 1-x N devices is its difficulty in etching, specifically with higher scandium concentration. In this work, we have developed an experimental approach with high temperature annealing followed by a wet etching process using tetramethyl ammonium hydroxide (TMAH), which maintains etching uniformity across various Sc compositions. The experimental results of etching approximately 730 nm of Sc x Al 1-x N (x = 0.125, 0.20, 0.40) thin films show that the etch rate decreases with increasing scandium content. Nevertheless, sidewall verticality of 85°~90° (±0.2°) was maintained for all Sc compositions. Based on these experimental outcomes, it is anticipated that this etching procedure will be advantageous in the fabrication of acoustic, photonic, and piezoelectric devices.

36 MATERIALS SCIENCE↗

Irradiation Testing of Ultrasonic Transducers

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of numerous parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 (E> 0.1 MeV). This test will be an instrumented lead test; and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. By characterizing magnetostrictive and piezoelectric transducer survivability during irradiation, test results will enable the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers

Daw, J.↗

Systems, methods and patches for monitoring a structural health of a connector in overhead transmission lines

Systems, methods and piezoelectric patches are provided for monitoring the structural health of connectors in overhead transmission lines. A plurality of piezoelectric patches is mounted to different locations on the connector. At least one of the patches is actuated using an AC voltage and certain electrical properties either from the same patch or of a different patch are evaluated over time to determine the structural health of the connectors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

System and method of phase-locked fiber interferometry

A system and method are provided for optical homodyne detection in an optical fiber interferometer. A detection signal is obtained by interfering an optical data signal with a phase-modulated optical reference signal. The modulator for the optical reference signal is phase-locked to an oscillatory modulation waveform. In embodiments, the modulator includes a piezoelectric element. In more specific embodiments, the modulator is a piezoelectric optical fiber-stretcher.

Katzenmeyer, Aaron Michael↗

Surface acoustic wave sensor for refrigerant leakage detection

A SAW sensor is optimized for detection of refrigerant leakage in a refrigerant system or other gases, vapors, explosives or chemicals of interest. The SAW sensor includes a piezoelectric substrate; an interdigitated transducer deposited on the piezoelectric substrate, the interdigitated transducer having an input portion that receives input surface acoustic waves and an output portion that emits output surface acoustic waves; and a refrigerant sensor film located between the input portion and the output portion of the interdigitated transducer, the refrigerant sensor film including a sorbent material that is selected for preferential adsorption of a target refrigerant over atmospheric gases. Adsorption of the target refrigerant by the sorbent material results in a frequency shift of a frequency of the output surface acoustic waves relative to a frequency of the input surface acoustic waves. The sorbent material may be a metal organic framework (MOF) material, a covalent organic framework (COF) material, a porous organic cage or organic macrocyles such as calix [n] arene and its related derivatives.

Kunapuli, Raghuit Prasad↗

Localized strain profile in surface electrode array for programmable composite multiferroic devices

In this work, we investigate localized in-plane strains on the microscale, induced by arrays of biased surface electrodes patterned on piezoelectrics. Particular focus is given to the influence that adjacent electrode pairs have on one another to study the impact of densely packed electrode arrays. We present a series of X-ray microdiffraction studies to reveal the spatially resolved micrometer-scale strain distribution. The strain maps with micrometer-scale resolution highlight how the local strain profile in square regions up to 250 x 250 lm 2 in size is affected by the surface electrodes that are patterned on ferroelectric single-crystal [Pb(Mg 1/3 Nb 2/3 )O 3 ] x -[PbTiO 3 ] 1-x . The experimental measurements and simulation results show the influence of electrode pair distance, positioning of the electrode pair, including the angle of placement, and neighboring electrode pair arrangements on the strength and direction of the regional strain. Our findings are relevant to the development of microarchitected strain-mediated multiferroic devices. The electrode arrays could provide array-addressable localized strain control for applications including straintronic memory, probabilistic computing platforms, microwave devices, and magnetic-activated cell sorting platforms.

42 ENGINEERING↗

Recent Advances in 3D Printed Sensors: Materials, Design, and Manufacturing

Sensors are of great importance in different aspects of research and industry. Future sensors will require high-efficient and low-cost manufacturing, as well as high-performance functionality in areas, such as mechanical sensing, biomedical, and optical applications. Recent advances in 3D printing open a new paradigm for sensors fabrication as a precision, customizable, and seamless process. Here, in this article, the state-of-the-art 3D printing methods in sensors manufacturing is reviewed and the performance of the 3D printed sensing materials and devices is summarized. Special attention is paid to emerging multimaterial printing and 4D printing technologies, which will benefit the fabrication of a new generation of structures with multifunctionalities. The content on 3D printed sensors covers piezoelectric sensors, medical, and optical sensing devices. The performance of 3D printed sensors in comparison with the sensors made by traditional manufacturing is also covered. Finally, section 4 provides the viewpoints on the future development of 3D printed sensors.

36 MATERIALS SCIENCE↗

Applications of Strain-Coupled Magnetoelectric Composites

This article deals with research, development and future directions of magnetoelectric composites for practical devices applications. In the past 20 years there has been a surge of research in the area of multiferroics (MF) and magnetoelectrics (ME) due to their potential to replace existing technologies based only on ferroelectric or ferromagnetic materials. Some of the magnetoelectric composites show exceptionally high potential in the area of magnetic field sensors, however, work remains before commercialization can be realized. The cross coupling among various ferroic parameters in magnetoelectric composites is several orders higher than single phase magetoelectrics, which make its favorable for low detection (nT or pT) magnetic field sensors. Advances in both layered structures or controlled three-dimensional matrix composites for applications as magnetoelectric nonvolatile memory elements are both required. Robust cross-coupling among various parameters with more than four logic states and its compatibility with complementary-symmetry metal–oxide–semiconductor (CMOS) technology are the main requirements for heterostructure magnetoelectric thin films. The major hurdles in the area of magnetoelectric nonvolatile memory elements are poor interfacial properties and weak magnetoelectric coupling for high density fast read and write processes. Another potential area is strained coupled magneto-electric composites where magnetostriction mediated dimensional change in the magnetic layer effectively modulate the change in the dimension of piezoelectric layers via piezostriction, which leads to a strong ME coupling where their coupling magnitude is sufficient for magnetic field sensors. Energy harvesters based on magnetoelectric composites are also intriguing concepts to capture various types of waste energy, in the form mechanical vibration, pressure, wind energy, hydrothermal and waste temperature.

36 MATERIALS SCIENCE↗

Ink-based laser powder bed fusion of barium titanate

Barium titanate (BTO) is a lead-free functional ceramic that is widely used in sensors, transducers, and actuators. The increasing demand for complex geometries and quick design iterations motivates the use of additive manufacturing techniques. Laser powder bed fusion (L-PBF) additive manufacturing technique enables the net-shape or near-net-shape fabrication of metals and alloys. Ceramic L-PBF remains challenging due to their high melting temperature. Here, to address this challenge, a nanoparticle ink feedstock was incorporated into the L-PBF process to allow low power melting of BTO. Key print parameters (i.e. laser power, scanning speed, and hatching spacing) were optimized to fabricate millimeter-scale BTO parts. The printed BTO samples possessed an inhomogeneous equiaxed-columnar-cellular microstructure. Semiconducting current-voltage behavior was observed in as-printed samples, which was attributed to the creation of oxygen vacancies. The piezoelectric d 33 coefficient was measured to be 4.6 pC/N.

Dielectrics↗

Core/Shell-Like Localized Emission at Atomically Thin Semiconductor–Au Interface

Localized emission in atomically thin semiconductors has sparked significant interest as single-photon sources. Despite comprehensive studies into the correlation between localized strain and exciton emission, the impacts of charge transfer on nanobubble emission remains elusive. Here, in this paper, we report the observation of core/shell-like localized emission from monolayer WSe 2 nanobubbles at room temperature through near-field studies. By altering the electronic junction between monolayer WSe 2 and the Au substrate, one can effectively adjust the semiconductor to metal junction from a Schottky to an Ohmic junction. Through concurrent analysis of topography, potential, tip-enhanced photoluminescence, and a piezo response force microscope, we attribute the core/shell-like emissions to strong piezoelectric potential aided by induced polarity at the WSe 2 –Au Schottky interface which results in spatial confinement of the excitons. Our findings present a new approach for manipulating charge confinement and engineering localized emission within atomically thin semiconductor nanobubbles. These insights hold implications for advancing the nano and quantum photonics with low-dimensional semiconductors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Revealing Antiferroelectric Switching and Ferroelectric Wakeup in Hafnia by Advanced Piezoresponse Force Microscopy

Hafnium oxide (HfO 2 )-based ferroelectrics offer remarkable promise for memory and logic devices in view of their compatibility with traditional silicon complementary metal oxide semiconductor (CMOS) technology, high switchable polarization, good endurance, and thickness scalability. These factors have led to a steep rise in the level of research on HfO 2 over the past number of years. While measurements on capacitors are promising for understanding macroscopic effects, many open questions regarding the emergence of ferroelectricity and electric field cycling behaviors remain. Continued progress requires information regarding the nanoscale ferroelectric behaviors on the bare surface (i.e., without encapsulation), which is notably absent. To overcome this barrier, we have applied complementary modes of piezoresponse force microscopy with the goal of directly and quantitatively sensing nanoscale ferroelectric behaviors in bare HfO 2 thin films. Our results on 8 nm Si-doped HfO 2 reveal nanoscale domains of local remnant polarization states exhibiting a weak piezoelectric coupling (deff) in the range 0.6–1.5 pm/V. While we observed localized enhancement of deff during progressive stressing of the bare HfO 2 thin film, we did not detect stable polarization switching which is a prerequisite of ferroelectric switching. We find that this result could be explained using polarization switching spectroscopy which revealed antiferroelectric-like switching in the form of pinched hysteresis loops as well as increasing remnant response with repeated cycling. As such, our results offer a promising route for material scientists who want to explore the nanoscale origins of antiferroelectricity and ferroelectric wakeup in HfO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗