Search NASA⌕ Search

SEARCH · Search NASA

Results for “PITTING CORROSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Cryo-based Structural Characterization and Growth Model of Salt Film on Metal

Metal salt films play a critical role in high rate dissolution processes such as within an active pit. However, structural and compositional characterization of salt films is challenging owing to the dynamic nature of the dissolving interface. Here, the salt film formed on SS304 one-dimensional artificial pit surface was directly characterized using flash freezing and cryo-based focused ion beam/scanning electron microscopy. The salt film exhibits a porous structure. Ni is co-located with Fe in the salt film, indicating the formation of co-precipitated salt containing Fe2+ and Ni2+. Additionally, a salt film growth model is presented based on ion transport.

Salt film, Pitting corrosion, Cryogenic, Cryo-FIB/↗

Correlation between corrosion resistance, anodic hydrogen evolution and microhardness in friction stir weldment of AA2198 alloy

Highlights: • There is a relationship between hardness, corrosion and H{sub 2} evolution in AA2198-T851 alloy friction stir weldment • Variation in the population density of T1 particles is the correlating factor for the relationship • The parent material is the region that is most susceptible to corrosion. • The weld zones of AA2198-T851 alloy friction stir weldment exhibit different forms of corrosion. - Abstract: Correlation between corrosion resistance, anodic hydrogen evolution and microhardness in the friction stir weldment of AA2198-T851 alloy has been investigated. Different microscopy techniques, scanning vibrating electrode technique (SVET) and potentiodynamic polarization tests were employed in the investigation. Unlike other 3rd generation Al-Cu-Li alloys where the regions that are most susceptible to corrosion are always within the weld region, the results reveal that the parent material is the most susceptible in this case. There is a direct correlation between corrosion resistance, anodic hydrogen evolution and microhardness in the weldment, and the T{sub 1} phase is associated with the direct correlation.

36 MATERIALS SCIENCE↗

Effect of V Content on Corrosion Behavior of Al-V Alloys Produced by Mechanical Alloying and Subsequent Spark Plasma Sintering

Al-V alloys produced via high-energy ball milling have been reported to show simultaneous improvement of corrosion resistance and mechanical properties compared to traditional Al alloys. In these alloys, V content plays a crucial role in increasing or decreasing the corrosion resistance. Therefore, the effect of V and microstructure on corrosion of high-energy ball milled and subsequently spark plasma sintered Al-xV alloys (x = 2, 5, 10 at%) has been studied. Cyclic potentiodynamic polarization tests and electrochemical impedance spectroscopic analysis revealed the increment of V content up to 5 at% enhanced the corrosion resistance of the alloy. However, highly heterogeneous microstructure in Al-10 at%V resulted in significant localized corrosion over the immersion time. The electrochemical impedance spectroscopy studies over 14 days of immersion revealed underlying corrosion mechanisms.

36 MATERIALS SCIENCE↗

STATISTICAL SAMPLING FOR IN-SERVICE INSPECTION OF LIQUID WASTE TANKS AT THE SAVANNAH RIVER SITE

Savannah River Remediation, LLC (SRR) is implementing a statistical sampling strategy for In-Service Inspection (ISI) of Liquid Waste (LW) Tanks at the United States Department of Energy's Savannah River Site (SRS) in Aiken, South Carolina. As a component of SRS's corrosion control program, the ISI program assesses tank wall structural integrity through the use of ultrasonic testing (UT). The statistical strategy for ISI is based on the random sampling of a number of vertically oriented unit areas, called strips, within each tank. The number of strips to inspect was determined so as to attain, over time, a high probability of observing at least one of the worst 5% in terms of pitting and corrosion across all tanks. The probability estimation to determine the number of strips to inspect was performed using the hypergeometric distribution. Statistical tolerance limits for pit depth and corrosion rates were calculated by fitting the lognormal distribution to the data. In addition to the strip sampling strategy, a single strip within each tank was identified to serve as the baseline for a longitudinal assessment of the tank safe operational life. The statistical sampling strategy enables the ISI program to develop individual profiles of LW tank wall structural integrity that collectively provide a high confidence in their safety and integrity over operational lifetimes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DEPOSITION TANK CORROSION TESTING FOR ENHANCED CHEMICAL CLEANING POST OXALIC ACID DESTRUCTION

An Enhanced Chemical Cleaning (ECC) process is being developed to aid in the high level waste tank closure at the Savannah River Site. The ECC process uses an advanced oxidation process (AOP) to destroy the oxalic acid that is used to remove residual sludge from a waste tank prior to closure. The AOP process treats the dissolved sludge with ozone to decompose the oxalic acid through reactions with hydroxyl radicals. The effluent from this oxalic acid decomposition is to be sent to a Type III waste tank and may be corrosive to these tanks. As part of the hazardous simulant testing that was conducted at the ECC vendor location, corrosion testing was conducted to determine the general corrosion rate for the deposition tank and to assess the susceptibility to localized corrosion, especially pitting. Both of these factors impact the calculation of hydrogen gas generation and the structural integrity of the tanks, which are considered safety class functions. The testing consisted of immersion and electrochemical testing of A537 carbon steel, the material of construction of Type III tanks, and 304L stainless steel, the material of construction for transfer piping. Tests were conducted in solutions removed from the destruction loop of the prototype ECC set up. Hazardous simulants, which were manufactured at SRNL, were used as representative sludges for F-area and H-area waste tanks. Oxalic acid concentrations of 1 and 2.5% were used to dissolve the sludge as a feed to the ECC process. Test solutions included the uninhibited effluent, as well as the effluent treated for corrosion control. The corrosion control options included mixing with an inhibited supernate and the addition of hydroxide. Evaporation of the uninhibited effluent was also tested since it may have a positive impact on reducing corrosion. All corrosion testing was conducted at 50 C. The uninhibited effluent was found to increase the corrosion rate by an order of magnitude from less than 1 mil per year (mpy) for an inhibited waste to a range of 5 to 23.4 mpy, depending on sludge chemistry. F-area-based effluents were, in general, more corrosive. Effective corrosion control measures included evaporation, hydroxide additions and mixing with supernates containing a representative supernate chemistry (5 M hydroxide and 1.5 M nitrite). Corrosion rates with these measures were generally 0.2 mpy. The A537 carbon steel was found to be susceptible to pitting when the corrosion control measure involved mixing the ECC effluent with a supernate chemistry having minimal inhibitor concentrations (0.5 M hydroxide and 0.3 M nitrite). Corrosion rates in this case were near 1 mpy.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DETERMINATION OF CORROSION INHIBITOR CRITERIA FOR TYPE III/IIIA TANKS DURING SALT DISSOLUTION OPERATIONS SUMMARY DOCUMENT

Dissolution of salt from Type III/IIIA waste tanks at the Savannah River Site may create solutions with inhibitor concentrations below those currently required (0.6M OH{sup -} and 1.1M OH{sup -} + NO{sub 2}{sup -}) per the Corrosion Control Program for high nitrate salt solutions (5.5 to 8.5M NO{sub 3}{sup -}). An experimental program was conducted to evaluate the corrosion susceptibility of grade A537 carbon steel for waste simulants containing 4.5-8.5M NaNO{sub 3} with maximum inhibitor concentrations of 0.6M NaOH and 0.2M NaNO{sub 2}. These maximum inhibitor concentrations used in this program are at a reduced level from those currently required. Current requirements were initially established for the Types I, II and IV tanks made of A285 carbon steel. The experimental program involved corrosion testing to evaluate the pitting and stress corrosion stress corrosion cracking (SCC) susceptibility of the Type III/IIIA waste tank materials. The program was conducted in two phases; the results of the first phase were reported previously (WSRC-STI-2006-00029). In this second phase, the corrosion specimens were modified to represent the 'as-fabricated' condition of the tank wall, and included specimens with mill scale, ground welds and stress-relief heat treatments. The complete description of the corrosion testing and the results are reported herein. The collective corrosion test results for A537 carbon steel in high nitrate waste simulants (4.5 - 8.5M) with the maximum inhibitor concentrations of 0.6M NaOH and 0.2M NaNO{sub 2} were as follows: (1) In long-term non-polarized U-bend testing, heat treatment, similar to the waste tank stress relief regime, reduced the incidence of cracking over the 18-month test period. Vapor space SCC was found to initiate on non-heat treated U-bend coupons. (2) In polarized U-bend testing, cracking occurred on U-bend coupons that had welds prepared similar to those in the waste tanks, i.e. ground and heat treated. (3) In electrochemical testing, pitting occurred on all coupons independent of heat treatment, inhibitor concentration, temperature, surface preparation, or welding. (4) In slow strain rate testing, cracking occurred on samples tested in solutions containing up to the maximum inhibitor concentration. The primary conclusion derived from this experimental program is that A537 carbon steel exposed to high nitrate (> 5.5M) solutions at inhibitor levels below the current specifications (0.6M OH{sup -} and 1.1M OH{sup -} + NO{sub 2}{sup -}) are susceptible to localized corrosion in the form of pitting and stress corrosion cracking. Long-term storage (e.g., greater than 100 days) of dissolved salt solutions not meeting the current inhibitor specifications for high nitrate salt chemistries in Type III waste tanks shall be avoided. Short term storage (e.g., less than 100 days) at low temperatures (e.g., less than 50 C) in these tanks is permissible for waste removal purposes. The stress relief process reduces the risk of SCC in the Type III waste tanks. On the other hand, the current inhibitor specifications should be strictly followed for the Type I, II and IV waste chemistry to prevent initiation of localized corrosion mechanisms. These tanks were not stress relieved and are more susceptible to SCC.

36 MATERIALS SCIENCE↗

FY24 Progress Report: Disposition of Cracks & Features Observed in the Inner Can Closure Weld Region (ICCWR) of the 3013 Package

The long-term integrity of the 3013 containers is of interest for the safe storage of Pu materials. Although the 3013 standard embodies multiple barrier concept, the integrity of the inner container is considered to be crucial since it protects the Safety Class outer container from its contents. The container is designed to withstand high pressures that could result from the complete radiolysis of the maximum water content permissible by the 3013 standard. Shelf-life studies and destructive examination have not found high gas pressures but have found that corrosive gases are generated. Pitting and stress corrosion cracking (SCC) are considered to be critical corrosion modes for the performance of the inner container and have been observed during destructive examinations. Considerable research has been conducted on the possibility of aqueous electrolytes condensing on the inner container that can promote SCC. These studies indicate the uncertainties surrounding the formation of corrosive environments and the corrosion behavior of container materials. In this initial report, a Bayesian network (BN) model is described that can consider the uncertainties and the causal connections between various factors influencing the corrosion modes of the inner container. The BN model is preliminary and provides an initial framework to identify the necessary information. The report also provides initial experimental results on the electrochemical behavior of stainless steels in anticipated condensed environments from gas phase migration of acidic gases. The experimental results are consistent with the corrosion model. Recommendation for further work on the BN model include assembling an expert group to provide input to the BN structure and quantification of the conditional probability matrix, experimental studies to characterize the microstructure of the container, electrochemical studies to identify critical potentials for localized corrosion and SCC, and crack growth rate studies

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AN ASSESSMENT OF THE SERVICE HISTORY AND CORROSION SUSCEPTIBILITY OF TYPE IV WASTE TANKS

Type IV waste tanks were designed and built to store waste that does not require auxiliary cooling. Each Type IV tank is a single-shell tank constructed of a steel-lined pre-stressed concrete tank in the form of a vertical cylinder with a concrete domed roof. There are four such tanks in F-area, Tanks 17-20F, and four in H-Area, Tanks 21-24H. Leak sites were discovered in the liners for Tanks 19 and 20F in the 1980's. Although these leaks were visually observed, the investigation to determine the mechanism by which the leaks had occurred was not completed at that time. Therefore, a concern was raised that the same mechanism which caused the leak sites in the Tanks in F-area may also be operable in the H-Area tanks. Data from the construction of the tanks (i.e., certified mill test reports for the steel, no stress-relief), the service history (i.e., waste sample data, temperature data), laboratory tests on actual wastes and simulants (i.e., electrochemical testing), and the results of the visual inspections were reviewed. The following observations and conclusions were made: (1) Comparison of the compositional and microstructural features indicate that the A212 material utilized for construction of the H-Area tanks are far more resistant to SCC than the A285 materials used for construction of the F-Area tanks. (2) A review of the materials of construction, temperature history, service histories concluded that F-Area tanks likely failed by caustic stress corrosion cracking. (3) The environment in the F-Area tanks was more aggressive than that experienced by the H-Area tanks. (4) Based on a review of the service history, the H-Area tanks have not been exposed to an environment that would render the tanks susceptible to either nitrate stress corrosion cracking (i.e., the cause of failures in the Type I and II tanks) or caustic stress corrosion cracking. (5) Due to the very dilute and uninhibited solutions that have been stored in Tank 23H, vapor space corrosion has occurred on some of areas of the liner. The mild pitting that was observed is broad and shallow and has no structural impact. Further significant pit growth has not been observed since the 1980's.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating the Impact of Redox Potential on the Corrosion of Q125, 316L, and C276 Steel in Low-Temperature Geothermal Systems

Time series experiments were used to explore the fluid redox impact on the corrosion of Q125, 316L, and C276 steels in low-ionic-strength and neutral water at temperature and pressure conditions associated with low-temperature geothermal systems. After exposing polished samples of each steel grade to an oxidizing (H2O2) and a reducing (Zn-doped) fluid for intervals of 24 h, 1 week, and 6 weeks, the atomic force microscopy results revealed general corrosion for Q125, while 316L and C276 exhibited pitting, crevice expansion, and edge attack corrosion. Secondary depositional features are frequently found as topographic highs, adjacent to pitting corrosion. These features may be identified as there is a very strong spatial correlation between the height retrace and phase retrace surface maps. All steels became progressively rougher over time after exposure to both fluids, while the corrosion rates were more complex. Samples exposed to the reducing fluid experienced an increase in the corrosion rate over time, while C276 and 316L experienced a decrease in the corrosion rate. Finally, a novel data validation technique was developed to address the intrinsic scalability of corrosion. The results indicate that the AFM scan area does not affect the measured surface roughness over nearly three orders of magnitude.

Bowman, Samuel (ORCID:000000021510174X)↗

Evaluation Of Corrosion-Resistant Alloys for Use in Acidic and Marine Launch Environments at NASA Kennedy Space Center: 20-Year Study

After the completion of an initial three-year study to qualify corrosion-resistant stainless steel tubing for use in NASA Kennedy Space Center’s acidic and marine launch environment, test specimens remained exposed at the KSC Beachside Atmospheric Corrosion Test Site for long-term exposure. NASA KSC’s lifetime requirement for most ground support equipment is twenty years. After twenty-one years of marine exposure, NASA KSC took the unique opportunity to reevaluate the tubing after long-term exposure to better understand the corrosion resistance of these alloys as they reached their expected lifetime requirement. Metallurgical and corrosion analysis was performed on the CRES tubing components and the alloys were rated on performance. A summary of CRES alloy tubing corrosion-related performance after 20 years of exposure in a marine launch environment is presented in this work.

NASA KSC↗

Determining the Efficiency of Nitrogen Blanketing to Mitigate Corrosion in Hanford’s Transfer Line System

The Hanford site stores large quantities of radioactive waste in underground, carbon-steel, double-shell tanks. The waste is transferred between the tanks using piping that consists of carbon-steel pipes and carbon-steel encasements. The transfer lines have shown extensive corrosion on both the interior of the casing and exterior of the carrier pipes. Nitrogen blanketing, used to displace the oxygen in the transfer lines, was hypothesized to reduce the corrosion of the transfer lines. Experimental studies were conducted to investigate the effect of oxygen concentration on the corrosion rate and the initiation of pitting on carbon steel. The results indicated that controlling the oxygen concentration to 0% effectively mitigates corrosion. However, at 5 vol% oxygen, a significant increase in the general corrosion rate and pitting corrosion is observed.

Atmospheric Corrosion↗

Risk Based Corrosion Studies at SRS

Elizabeth Hoffman presents an overview of risk based corrosion studies done at SRS with the goals of improved control in the processes and tank design. .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE SENSITIVITY OF CARBON STEELS' SUSCEPTIBILITY TO LOCALIZED CORROSION TO THE PH OF NITRATE BASED NUCLEAR WASTES

The Hanford tank reservation contains approximately 50 million gallons of liquid legacy radioactive waste from cold war weapons production, which is stored in 177 underground storage tanks. The tanks will be in use until waste processing operations are completed. The wastes tend to be high pH (over 10) and nitrate based. Under these alkaline conditions carbon steels tend to be passive and undergo relatively slow uniform corrosion. However, the presence of nitrate and other aggressive species, can lead to pitting and stress corrosion cracking. This work is a continuation of previous work that investigated the propensity of steels to suffer pitting and stress corrosion cracking in various waste simulants. The focus of this work is an investigation of the sensitivity of the steels' pitting and stress corrosion cracking susceptibility tosimulant pH. Previous work demonstrated that wastes that are high in aggressive nitrate and low in inhibitory nitrite are susceptible to localized corrosion. However, the previous work involved wastes with pH 12 or higher. The current work involves wastes with lower pH of 10 or 11. It is expected that at these lower pHs that a higher nitrite-to-nitrate ratio will be necessary to ensure tank integrity. This experimental work involved both electrochemical testing, and slow strain rate testing at either the free corrosion potential or under anodic polarization. The results of the current work will be discussed, and compared to work previously presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Behavior of Fe-7Cr-1Mo-12Zr Metal Waste Form Alloy in Simulated Repository Environment

Metal waste forms (MWF) are solid metallic waste categorized as high-level radioactive waste generated during pyro-reprocessing of spent metallic fuels and geologically disposed off. This waste form generated requires an excellent corrosion resistance in a geological repository environment. In the present work, Fe-7Cr-1Mo-12Zr MWF alloy was developed by casting in an arc melting furnace. The x-ray diffraction analysis revealed the formation of stable phases of α-Fe solid solution and the intermetallic phases of Fe{sub 2}Zr and Fe{sub 23}Zr{sub 6}. The corrosion behavior of Fe-7Cr-1Mo-12Zr alloy was investigated using electrochemical techniques in aggressive (highly acidic with Cl{sup −}) and nominal repository pH environment. Cyclic potentiodynamic polarization studies indicated the shift in corrosion potential toward cathodic potential in highly acidic solution with Cl{sup −}. The corrosion mechanism of pitting is associated with acidified pH medium with more Cl{sup −}, whereas uniform corrosion or transpassive dissolution is resultant of mild acidity or mild alkaline medium. The passive region is wider in pH 5 and 8 when compared to pH 1 and 3. Electrochemical impedance spectroscopic (EIS) analysis revealed the lowering of passive film stability in the highly acidic medium in the presence of Cl{sup −}. The role of passive oxide layers on the corrosion resistance of the Fe-7Cr-1Mo-12Zr MWF alloy is discussed.

36 MATERIALS SCIENCE↗

SRNL SHELF LIFE STUDIES - SCC STUDIES AT ROOM TEMPERTURE [stress corrosion cracking ]

Phase II, Series 2 corrosion testing performed by the Savannah River National Laboratory (SRNL) for the Department of Energy 3013 container has been completed. The corrosion tests are part of an integrated plan conducted jointly by Los Alamos National Laboratory and the Savannah River Site. SRNL was responsible for conducting corrosion studies in small-scale vessels to address the influence of salt composition, water loading, and type of oxide/salt contact on the relative humidity inside a 3013 container and on the resulting corrosion of Type 304L and 316L stainless steel (304L and 316L). This testing was conducted in two phases: Phase I evaluated a broad spectrum of salt compositions and initial water loadings on the salt mixtures exposed to 304L and 316L and the resulting corrosion; Phase II evaluated the corrosion of 304L at specific water loadings and a single salt composition. During Phase I testing at high initial moisture levels (0.35 to 1.24 wt%)a, the roomtemperature corrosion of 304L exposed to a series of plutonium oxide/chloride salt mixtures ranged from superficial staining to pitting and stress corrosion cracking (SCC). 304L teardrop coupons that exhibited SCC were directly exposed to a mixture composed of 98 wt % PuO2, 0.9 wt % NaCl, 0.9 wt % KCl, and 0.2 wt % CaCl2. Cracking was not observed in a 316L teardrop coupon. Pitting was also observed in this environment for both 304L and 316L with depths ranging from 20 to 100 μm. Neither pitting nor SCC was observed in mixtures with a greater chloride salt concentration (5 and 28 wt%). These results demonstrated that for a corrosive solution to form a balance existed between the water loading and the salt chloride concentration. This chloride solution results from the interaction of loaded water with the hydrating CaCl2 salt. In Phase II, Series 1 tests, the SCC results were shown to be reproducible with cracking occurring in as little as 85 days. The approximate 0.5 wt% moisture level was found to result in an initial relative humidity of ~55% within the small-scale vessels. Pits were found to be associated with cracks and appeared to act as initiators for the cracking. In a vapor-space only exposure, the weld oxide, which results from the TIG closure weld used to fabricate the teardrop coupon, was also shown to be more susceptible to pitting corrosion than a surface free from weld oxide. This result has important implications for the closure weld of the 3013 inner can since the weld oxide on the can internal surface cannot be removed. The results from the Phase II, Series 2 tests further demonstrated the significance of forming a solution with a critical chloride concentration for corrosion to proceed. 304L teardrop coupons were found to corrode only by pitting with a similar oxide/salt mixture as used in Series 1 testing but with a lower water loading of 0.2 wt%, which resulted in an initial relative humidity of 35-38%. These tests ran twice as long as those for Series 1 testing. The exposure condition was also found to impact the corrosion with salt-exposed surfaces showing lower corrosion resistance. Additional analyses of the Series 2 coupons are recommended especially for determining if cracks emanate from the bottom of pits. Data generated under the 2009 3013 corrosion test plan, as was presented here, increased the understanding of the corrosion process within a sealed 3013 container. Along with the corrosion data from destructive evaluations of 3013 containers, the inner can closure weld region (ICCWR) has been identified as the most vulnerable area of the inner can where corrosion may lead to corrosive species leaking to the interior surface of the outer container, thereby jeopardizing the integrity of the 3013 container. A new corrosion plan has been designed that will characterize the corrosion at the ICCWR of 3013 DEs as well as parameters affecting this corrosion.

3013 plutonium storage, stress corrosion cracking,↗

EVIDENCE OF CORROSIVE GAS FORMED BY RADIOLYSIS OF CHLORIDE SALTS IN PLUTONIUM-BEARING MATERIALS

Corrosion and pitting have been observed in headspace regions of stainless steel containers enclosing plutonium oxide/salt mixtures. These observations are consistent with the formation of a corrosive gas, probably HCl, and transport of that gas to the headspace regions of sealed containers. The NH{sub 4}Cl films found on the walls of the sealed containers is also indicative of the presence of HCl gas. Radiolysis of hydrated alkaline earth salts is the probable source of HCl.

36 MATERIALS SCIENCE↗