Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASTIC MATERIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Conductive plastics

Electrically conductive plastics fabrication and applications limitations, discussing plastic matrix materials loaded with various conductive fillers

Litant, I.↗

Use of thin plastic films at cryogenic temperatures

Commercially available plastic film materials that remain flexible at cryogenic temperatures and resist failures caused by folds and wrinkles created during expulsion were investigated for use in expulsion bladders for liquefied gases. Compatible adhesive systems, fabrication techniques, and results of impact and dynamic loading tests are summarized.

Lark, R. F.↗

Organic contamination analysis: High resolution mass spectrometric analysis of surface organics on selected areas of Surveyor 3

The mirror and middle shroud were extracted for organics by washing the surfaces with solvents. The techniques are discussed. Ion microprobe analyses of the primarily atomic species are presented. The sources of the organic contaminants are: (1) hydrocarbons from lubricating oils and general terrestrial contamination, (2) dioctyl phthalate, probably from polyethylene bagging material (the plasticizer), (3) carboxylic acids from decomposition of grease and general terrestrial contamination, (4) silicones from sources such as lubricating oil, (5) outgassing of electronics and plasticizer, (6) vinyl alcohol and styrene copolymer, probably from electronic insulation, and (7) nitrogenous compounds from the lunar module and possibly Surveyor 3 engine exhaust.

Simoneit, B. R.↗

White blood cell counting system

The design, fabrication, and tests of a prototype white blood cell counting system for use in the Skylab IMSS are presented. The counting system consists of a sample collection subsystem, sample dilution and fluid containment subsystem, and a cell counter. Preliminary test results show the sample collection and the dilution subsystems are functional and fulfill design goals. Results for the fluid containment subsystem show the handling bags cause counting errors due to: (1) adsorption of cells to the walls of the container, and (2) inadequate cleaning of the plastic bag material before fabrication. It was recommended that another bag material be selected.

Source record↗

Orbital and entry tracking accessory for globes

An orbital and entry tracking accessory or attachment is described which can be mounted on a globe to provide a rapid means of determining range requirements for entry vehicles returning from any orbit to any desired landing site with reasonable accuracy. The device is constructed of clear plastic strip material, and comprises a support ring, a calibrated orbital track member rigidly carried by the support ring, and a calibrated lateral range member pivotally coupled to the support ring at points such that the lateral range member is always oriented normally to the orbital track member. The assembly is mountable on the globe relatively snugly, but freely movable. At least one of the members has a detachable coupling which permits placement of the device on the globe.

Pritchard, E. B.↗

Parylene coating for circuit components

Inexpensive internal coating improves reliability of plastic-packaged parts. Coating protects device from effects of humidity and heat and acts as barrier between device and harmful substances generated by plastic-packaging material.

Berkebile, M. J.↗

Ceramic composite protection for turbine disc bursts

Ceramic composite turbine disc protection panels for the A300B were developed using armor technology. Analytical predictions for modifying the ballistic projectile armor system were verified by a test program conducted to qualify the rotor containment system. With only a slight change in the areal density of the armor system a more than two-fold increase in kinetic energy protection level was achieved. Thickness of the fiberglass reinforced plastic backing material was increased to achieve an optimum ratio of ceramic thickness to backing thickness for the different ballistic defeat condition.

Gardner, P. B.↗

Owens-Illinois liquid solar collector materials assessment

From the beginning, it was noted that the baseline drawings for the liquid solar collector exhibited a distinct weakness concerning materials specification where elastomers, plastics, and foam insulation materials were utilized. A relatively small effort by a competent design organization would alleviate this deficiency. Based on results obtained from boilout and stagnation tests on the solar simulator, it was concluded that proof testing of the collector tubes prior to use helps to predict their performance for limited service life. Fracture mechanics data are desirable for predicting extended service life and establishing a minimum proof pressure level requirement. The temperature capability of this collector system was increased as the design matured and the coating efficiency improved. This higher temperature demands the use of higher temperature materials at critical locations in the collector.

Nichols, R. L.↗