Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASTIC SCINTILLATION DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The nuclear radiation monitor for the Spacelab/Shuttle

A 5 inch by 5 inch diameter sodium iodide scintillation crystal, viewed by a 5 inch photomultiplier was designed to be mounted near the center of the shuttle payload bay to quantitatively measure the neutron and gamma ray environment during the second Spacelab mission. The expected energy resolution is 8% FWHM at 662 keV. The detector will operate in an energy range from 0.1 to 20 MeV. A charged anticoincidence shield consisting of a 1 cm thick plastic scintillator viewed by three 2 inch photomultiplier tubes, covers the crystal detector which has nearly omnidirectional response.

Fishman, G. J.↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

Subcriticality Measurements with HEU (93.2) Metal Annular Storage Castings

These carefully performed and documented measurements with unreflected and unmoderated highly enriched uranium (HEU) castings can be used to benchmark calculational methods for the time decay of the fission chain multiplication process as measured with small (1 x 1 x 6 in. thick plastic scintillators with 1/4-in.-thick lead on all detector surfaces) detectors adjacent to the tightly fitting stainless steel cans that contained the HEU ({approx}93 wt%) metal. Prompt time decay measurements were performed stimulating the fission chain multiplication process with a timed, tagged Cf spontaneous fission source that emitted fission-spectrum neutrons and a time and directionally tagged 14.1-MeV neutrons from the DT reaction in a steady state generator with an embedded alpha detector. Time decay measurements were performed with HEU masses varying from 18 to 90 kg for a wide variety of source-detector-casting configurations. The use of a DT generator provided no addition information about the fission chain behavior beyond that provided by a time-tagged Cf spontaneous fission source. The main quantities obtained in the measurements were (1) the time distribution of the counts in a detector after a neutron fission in the Cf source or after the alpha detection coincident with the emission of a neutron from the DT generator (the equivalent of a pulsed neutron measurement with a randomly pulsed source) and (2) the time distribution of counts in one detector after a count in another detector (the equivalent of a two-detector Rossi-alpha measurement). Monte Carlo calculations using the MCNP-PoliMi coupled gamma-neutron transport code generally agreed with the measurement results except for some differences early in the fission chain decay process. The measurements that were performed with the HEU about 1 m above the floor were considerably affected by room return neutrons at times as early as 100 ns, and at times after 300 ns, a major portion of the time response was associated with the interaction of the HEU assemblies with the floor. This room-return effect increased with the size of the assembly because the larger assemblies subtend a larger solid angle to a neutron returning from the floor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PVT Analysis With A Deconvolution Algorithm

Polyvinyl Toluene (PVT) plastic scintillator is the most common gamma ray detector material used for large systems when only gross counting is needed because of its low cost, robustness, and relative sensitivity. PVT does provide some energy information about the incident photons, as has been demonstrated through the development of Energy Windowing analysis. There is a more sophisticated energy analysis algorithm developed by Symetrica, Inc., and they have demonstrated the application of their deconvolution algorithm to PVT with very promising results. The thrust of such a deconvolution algorithm used with PVT is to allow for identification and rejection of naturally occurring radioactive material, reducing alarm rates, rather than the complete identification of all radionuclides, which is the goal of spectroscopic portal monitors. Under this condition, there could be a significant increase in sensitivity to threat materials. The advantage of this approach is an enhancement to the low cost, robust detection capability of PVT-based radiation portal monitor systems. The success of this method could provide an inexpensive upgrade path for a large number of deployed PVT-based systems to provide significantly improved capability at a much lower cost than deployment of NaI(Tl)-based systems of comparable sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preliminary investigations on the determination of three-dimensional dose distributions using scintillator blocks and optical tomography

Purpose: Clinical QA in teletherapy as well as the characterization of experimental radiation sources for future medical applications requires effective methods for measuring three-dimensional (3D) dose distributions generated in a water-equivalent medium. Current dosimeters based on ionization chambers, diodes, thermoluminescence detectors, radiochromic films, or polymer gels exhibit various drawbacks: High quality 3D dose determination is either very sophisticated and expensive or requires high amounts of effort and time for the preparation or read out. New detectors based on scintillator blocks in combination with optical tomography are studied, since they have the potential to facilitate the desired cost-effective, transportable, and long-term stable dosimetry system that is able to determine 3D dose distributions with high spatial resolution in a short time.Methods: A portable detector prototype was set up based on a plastic scintillator block and four digital cameras. During irradiation the scintillator emits light, which is detected by the fixed cameras. The light distribution is then reconstructed by optical tomography, using maximum-likelihood expectation maximization. The result of the reconstruction approximates the 3D dose distribution. First performance tests of the prototype using laser light were carried out. Irradiation experiments were performed with ionizing radiation, i.e., bremsstrahlung (6 to 21 MV), electrons (6 to 21 MeV), and protons (68 MeV), provided by clinical and research accelerators.Results: Laser experiments show that the current imaging properties differ from the design specifications: The imaging scale of the optical systems is position dependent, ranging from 0.185 mm/pixel to 0.225 mm/pixel. Nevertheless, the developed dosimetry method is proven to be functional for electron and proton beams. Induced radiation doses of 50 mGy or more made 3D dose reconstructions possible. Taking the imaging properties into account, determined dose profiles are in agreement with reference measurements. An inherent drawback of the scintillator is the nonlinear light output for high stopping-power radiation due to the quenching effect. It impacts the depth dose curves measured with the dosimeter. For single Bragg peak distributions this leads to a peak to plateau ratio of 2.8 instead of 4.5 for the reference ionization chamber measurement. Furthermore, the transmission of the clinical bremsstrahlung beams through the scintillator leads to the saturation of one camera, making dose reconstructions in that case presently not feasible.Conclusions: It is shown that distributions of scintillation light generated by proton or electron beams can be reconstructed by the dosimetry system within minutes. The quenching apparent for proton irradiation, and the yet not precisely determined position dependency of the imaging scale, require further investigation and corrections. Upgrading the prototype with larger or inorganic scintillators would increase the detectable proton and electron energy range. The presented results show that the determination of 3D dose distributions using scintillator blocks and optical tomography is a promising dosimetry method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive neutron coincidence counting with plastic scintillators for the characterization of radioactive waste drums

The quantification of radioactive material is essential in the fields of safeguards, criticality control of nuclear processes, dismantling of nuclear facilities and components, or radioactive waste characterization. The Nuclear Measurement Laboratory (LMN) of CEA is involved in the development of time-correlated neutron detection techniques using plastic scintillators. Usually, 3He proportional counters are used for passive neutron coincidence counting owing to their high thermal neutron capture efficiency and gamma insensitivity. However, the global {sup 3}He shortage in the past few years has made these detectors extremely expensive. In addition, contrary to {sup 3}He counters for which a few tens of microseconds are needed to thermalize fast neutrons, in view to maximize the {sup 3}He(n,p){sup 3}H capture cross section, plastic scintillators are based on elastic scattering and therefore the light signal is formed within a few nanoseconds, correlated pulses being detected within a few dozen- or hundred nanoseconds. This time span reflects fission particles time of flight, which allows reducing accordingly the duration of the coincidence gate and thus the rate of random coincidences, which may totally blind fission coincidences when using {sup 3}He counters in case of a high (α,n) reaction rate. However, plastic scintillators are very sensitive to gamma rays, requiring the use of a thick metallic shield to reduce the corresponding background. Cross talk between detectors is also a major issue, which consists on the detection of one particle by several detectors due to elastic or inelastic scattering, leading to true but undesired coincidences. Data analysis algorithms are tested to minimize cross-talk in simultaneously activated detectors. The distinction between useful fission coincidences and the correlated background due to cross-talk, (α,n) and induced (n,2n) or (n,n'γ) reactions, is achieved by measuring 3-fold coincidences. The performances of a passive neutron coincidence counting system for radioactive waste drums using plastic scintillators have been studied using the Monte Carlo radiation transport code MCNPX-PoliMi v2.0 coupled to data processing algorithms developed with ROOT data analysis software. In addition to the correlated background, accidental coincidences are taken into account in the simulation by randomly merging pulses from different calculations with fission and (α,n) sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COCOA: A compact Compton camera for astrophysical observation of MeV-scale gamma rays

COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.

79 ASTRONOMY AND ASTROPHYSICS↗

Charged pion production in $\nu_\mu$ interactions on hydrocarbon at $\langle E_{\nu}\rangle$= 4.0 GeV

Charged pion production via charged-current νμ interactions on plastic scintillator (CH) is studied using the MINERvA detector exposed to the NuMI wideband neutrino beam at Fermilab. Events with hadronic invariant mass W < 1.4 GeV and W < 1.8 GeV are selected in separate analyses: the lower W cut isolates single pion production, which is expected to occur primarily through the Δ(1232) resonance, while results from the higher cut include the effects of higher resonances. Cross sections as functions of pion angle and kinetic energy are compared to predictions from theoretical calculations and generator-based models for neutrinos ranging in energy from 1.5–10 GeV. The data are best described by calculations which include significant contributions from pion intranuclear rescattering. As a result, these measurements constrain the primary interaction rate and the role of final state interactions in pion production, both of which need to be well understood by neutrino oscillation experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies of air showers produced by primaries 10(16) eV using a combined scintillation and water-Cerenkov array

An array of 8 x 1.0 sq m plastic scintillation counters and 13 water-Cerenkov detectors (1 to 13.5 sq m) were operated at the center of the Haverah Park array to study some features of air showers produced by 10(16) eV primaries. Measurements of the scintillator lateral distribution function, the water-Cerenkov lateral distribution function, and of the distance dependence of the Cerenkov/scintillator ratio are described.

Brooke, G.↗

Novel usage of deep learning and high-performance computing in long-baseline neutrino oscillation experiments

Mención Internacional en el título de doctorDeep-learning methods are playing a crucial role in numerous scientific and industrialapplications. Over the past two decades, these techniques have helped in the collection,reconstruction, and analysis of large data samples in particle physics experiments. Themain topic of this PhD research is the study of deep-learning techniques in long-baselineneutrino oscillation experiments. Neutrinos are mysterious light elementary particles,and their investigation is essential to shed light on some of the remaining open questionsin physics. The work presented here describes an algorithm based on a convolutionalneural network developed to provide highly accurate and efficient selections of electronneutrino and muon neutrino interactions in the Deep Underground Neutrino Experiment(DUNE). With this algorithm, the electron neutrino (antineutrino) selection efficiencypeaks at 90% (94%) and exceeds 85% (90%) for reconstructed neutrino energies between2-5 GeV. The selection efficiency for muon neutrino (antineutrino) interactions is foundto have a maximum of 96% (97%) and exceeds 90% (95%) efficiency for reconstructedneutrino energies above 2 GeV. When considering all electron neutrino and antineutrinointeractions as signal (both those appearing from oscillations and those intrinsic tothe beam), a selection purity of 90% is achieved. These event selections are criticalto maximise the sensitivity of the experiment to CP-violating effects, key to furtherunderstand the matter-antimatter asymmetry of the Universe.In high-energy physics experiments, deep learning has also been explored for producingfast simulations and physically-motivated manipulations of simulated images. Some ofthose simulations, such as the light production and detection, are very computationallyexpensive and require novel methods to produce the necessary samples while controllingthe varied underlying physics model parameters. To do so, we invented the model-assistedgenerative adversarial network (MAGAN), first validated on simple generic case studiesand then successfully applied to the DUNE photon-detector simulation.Moreover, we also developed graph neural networks for 3D-voxel classification ofambiguities and optical crosstalk for a different particle physics experiment, most preciselyfor the proposed SuperFGD. This novel 3D-granular plastic-scintillator neutrino detectorwill be used to upgrade the near detector of the T2K neutrino oscillation experiment, and our method reports efficiencies and purities of 94-96% per event in the classificationof particle track voxels.Due to the growth and complexity of deep neural networks, researchers have beeninvestigating techniques to train those networks in a more computationally-efficient way.Many efforts have been made by the community to optimise deep-learning models byparallelising or distributing their training computation across multiple devices. In thisthesis, we study an approach based on data locality for those neural networks that cannotbenefit from scaling their computation due to a significant bottleneck in the data I/O.The research also includes a detailed study on the performance of deep neural networkson hardware accelerator boards.Los métodos de aprendizaje profundo son cada vez más utilizados en numerosas aplicacionescientíficas e industriales hoy en día. Durante las dos últimas décadas, estastécnicas se han empleado en la recolección, reconstrucción y análisis de la gran cantidadde datos generados por experimentos de física de partículas. El tema principal de estatesis doctoral es el uso de estos modelos de aprendizaje profundo en experimentos defísica de neutrinos, en concreto en los experimentos de larga distancia DUNE y T2K. Losneutrinos, partículas fundamentales neutras, de las más ligeras del Universo, pueden serclave para explicar algunas de las cuestiones todavía sin resolver en física fundamental.Entre las diferentes contribuciones que esta tesis ha hecho a su estudio, cabe destacar eldesarrollo de un algoritmo basado en una red de neuronas convolucional para seleccionarcon gran eficiencia y precisión las interacciones de neutrinos electrónicos y muónicos enel Deep Underground Neutrino Experiment (DUNE). La eficiencia de selección obtenidapara neutrinos (antineutrinos) electrónicos alcanza un máximo del 90% (94%) y supera el85% (90%) para neutrinos con energías reconstruidas en el rango 2-5 GeV. La selección deneutrinos (antineutrinos) muónicos tiene una eficiencia máxima del 96% (97%) y excedeel 90% (95%) para neutrinos con energías reconstruidas de más de 2 GeV. Considerandocomo señal todas las interacciones de neutrinos y antineutrinos electrónicos (procedentestanto de oscilaciones como intrínsecos en el haz inicial), se logra una pureza en la seleccióndel 90%. Dichas selecciones de eventos son fundamentales para maximizar la sensibilidaddel experimento a los efectos de violació...

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron-Lined Multitube Neutron Proportional Counter Test

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional counters, 2) Boron-lined proportional counters, 3) Lithium-loaded glass fibers, and 4) Coated non-scintillating plastic fibers. In addition, a few other companies have detector technologies that might be competitive in the near term as an alternative technology. Reported here are the results of tests of a boron-lined, “multitube” proportional counter manufactured by Centronic Ltd. (Surry, U.K. and Houston, TX). This testing measured the required performance for neutron detection efficiency and gamma-ray rejection capabilities of the detector.

3He↗

Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional counters, 2) Boron-lined proportional counters, 3) Lithium-loaded glass fibers, and 4) Coated non-scintillating plastic fibers. In addition, a few other companies have detector technologies that might be competitive in the near term as an alternative technology. Reported here are the results of tests of a boron-lined, multichamber proportional counter manufactured by LND, Inc. Also reported are results obtained with an earlier design of conventional, boron-lined, proportional counters from LND. This testing measured the required performance for neutron detection efficiency and gamma-ray rejection capabilities of the detectors.

3He↗

3He and BF3 Neutron Detector Pressure Effect and Model Comparison

Paper for SORMA conference Radiation detection systems for homeland security applications must possess the capability of detecting both gamma rays and neutrons. The radiation portal monitor (RPM) systems that are currently deployed use a plastic scintillator for detecting gamma rays and 3He gas-filled proportional counters for detecting neutrons. Proportional counters filled with 3He are the preferred neutron detectors for use in RPMs because 3He has a large neutron cross section, is relatively insensitive to gamma-rays, is neither toxic nor corrosive, can withstand extreme environments, and can be operated at a lower voltage than some of the alternative proportional counters. The amount of 3He required for homeland security and science applications has depleted the world supply and there is no longer enough available to fill the demand. Thus, alternative neutron detectors are being explored. Two possible temporary solutions that could be utilized while a more permanent solution is being identified are reducing the 3He pressure in the proportional counters and using boron trifluoride (BF3) gas-filled proportional counters. Reducing the amount of 3He required in each of the proportional counters would decrease the rate at which 3He is being used, not enough to solve the shortage but perhaps enough to increase the amount of time available to find a working replacement. BF3 is not appropriate for all situations as these detectors are less sensitive than 3He, BF3 gas is corrosive, and a much higher voltage is required than what is used with 3He detectors. Measurements of the neutron detection efficiency of 3He and BF3 as a function of tube pressure were made. The experimental results were also used to validate models of the RPMs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting sub-MeV neutrons in solid plastic scintillator with gamma-ray discrimination

We report on recent efforts to design a solid plastic scintillation hodoscope to measure neutron production cross sections at low energies. Our program includes not only the development of the detector itself, but also a set of auxiliary measurements which will help characterize its low-energy response. A novel scintillation counter has been developed to detect sub-MeV neutrons while rejecting gamma-ray backgrounds with good efficiency. The detector uses multiple layers of thin solid scintillator, with optical isolation between the adjacent layers. Incident low-energy neutrons produce ionizing recoil particles which remain within just one of the scintillator layers, while background gamma rays create electrons which most often cross the boundary between layers. By observing the trigger pattern within the layers, most gamma-ray backgrounds can be distinguished from the low-energy neutrons of interest. We report on the results of our Monte Carlo studies of this design, as well as on the operation of a prototype detector unit. We also have undertaken a new measurement of the neutron-proton total cross section below 1 MeV. Calculations of the efficiency for detecting low energy neutrons in plastic scintillator rely on accurate low energy n-p cross sections, yet surprisingly few such data currently exist. New measurements which span the region from 150 to 800 keV neutron (lab) energy are reported and discussed. Additionally, we have measured the light response of BC 418 scintillator for recoil proton energies as low as 100 keV. Recoil protons are produced at a known energy in the scintillator by placing it in a neutron beam and detecting in coincidence the elastically scattered neutrons at fixed angle. Our new results extend the energy range of previous measurements of the light response of solid organic scintillators, and may indicate a significantly modified response at the lowest observed energies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technology Transfer from Fermi Research Alliance to Itasca Plastics for the purpose of Commercializing Scintillator Material

Researchers at the Fermi National Accelerator Laboratory (Fermilab) developed extruded plastic scintillator in the late 1990s, which was first used in the D-Zero experiment. Extruded plastic scintillator is currently produced at Fermilab and is used in particle detectors worldwide. The purpose of this CRADA is to transfer the knowledge related to the Fermilab extrusion process to Itasca Plastics, Inc. (Itasca Plastics). Much of this knowledge is contained in documentation that is in the public domain, although it is distributed over several communications (papers, conference records, etc.) and over several years. Under this CRADA Fermilab will assemble the information, provide it to Itasca Plastics and provide limited consulting to complete the knowledge transfer. If the transfer is successful, Itasca Plastics will be able to establish a U.S. commercial manufacturing capability for extruded scintillator material that can be used for high energy physics and commercial applications.

36 MATERIALS SCIENCE↗

Scintillation counter and wire chamber front end modules for high energy physics experiments

This document describes two front-end modules developed for the proposed MIPP upgrade (P-960) experiment at Fermilab. The scintillation counter module was developed for the Plastic Ball detector time and charge measurements. The module has eight LEMO 00 input connectors terminated with 50 ohms and accepts negative photomultiplier signals in the range 0.25...1000 pC with the maximum input voltage of 4.0 V. Each input has a passive splitter with integration and differentiation times of {approx}20 ns. The integrated portion of the signal is digitized at 26.55 MHz by Analog Devices AD9229 12-bit pipelined 4-channel ADC. The differentiated signal is discriminated for time measurement and sent to one of the four TMC304 inputs. The 4-channel TMC304 chip allows high precision time measurement of rising and falling edges with {approx}100 ps resolution and has internal digital pipeline. The ADC data is also pipelined which allows deadtime-less operation with trigger decision times of {approx}4 {micro}s. The wire chamber module was developed for MIPP EMCal detector charge measurements. The 32-channel digitizer accepts differential analog signals from four 8-channel integrating wire amplifiers. The connection between wire amplifier and digitizer is provided via 26-wire twist-n-flat cable. The wire amplifier integrates input wire current and has sensitivity of 275 mV/pC and the noise level of {approx}0.013 pC. The digitizer uses the same 12-bit AD9229 ADC chip as the scintillator counter module. The wire amplifier has a built-in test pulser with a mask register to provide testing of the individual channels. Both modules are implemented as a 6Ux220 mm VME size board with 48-pin power connector. A custom europack (VME) 21-slot crate is developed for housing these front-end modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Report: Development of High Light Output Plastic Scintillating and Wavelength-Shifting Fibers

Scintillating plastic optical fibers have increasingly been used as radiation detectors in nuclear and high energy physics research since they were first made in 1965. It is proposed to make fibers which are at least a factor of 2 brighter and thereby improve detection efficiency, spatial resolution and energy resolution. When radiation strikes existing plastic scintillator only the singlet excited states rather than the triplet excited states are used to produce scintillation light. This means only 25% of the deposited energy is available to produce scintillation light. Utilization of phosphorescent molecules should therefore drastically improve the light output. This process has been called “triplet harvesting” and has been successfully demonstrated in improving the light output of “Organic Light Emitting Diodes, OLEDs”. The objective of this proposal is to produce a bright scintillating fiber using triplet harvesting and a light output time constant of a few nanoseconds. In addition, an increase in the light containment will be achieved by using a new low refractive index cladding material. In Phase 1, polystyrene plastic material will be used. Organo-metallic phosphorescent and conventional dyes will be dissolved in the plastic to demonstrate both the desired brightness and fast decay time. Photophysical properties will be measured. Scintillating fiber will be made. Commercial benefits of this new material include providing improved detection of rare events such as the HIGGS BOSON at the billion dollar high energy facilities. and monitoring stored radioactive material. The new material will also play an important role in making improved imaging detection facilities for protecting civilians and facilities against CBRN-E threats. In addition, the resolution will be improved for medical brachytherapy. The results of selected organic dyes dissolved in a polystyrene matrix performing as scintillating samples are presented. The proposed organo-metallic phosphorescent dyes were not used due to lengthy synthesis times and cost. Rather, an attempt was made to harvest triplet energy from polystyrene using appropriately wavelength-matched dyes. Samples studied include films and blocks. Fibers were not manufactured as a suitable set of dyes was not determined.

07 ISOTOPE AND RADIATION SOURCES↗

Scintillation detector with SiPM matrix as a photosensor

The results of a characterization study of the scintillation detector with SiPM matrices as multichannel photosensors are presented. The SiPM matrix attached to a plastic scintillator gives a snapshot of the glowing track of a charged particle traversing the scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗