Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLATES - COMPRESSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Possible mitigation of tokamak plasma–surface interactions using thermionic divertor plates with inverse sheaths

Recent studies demonstrate that when a plasma-facing surface emits a sufficient flux of electrons, it will form an inverse sheath. In this work, we consider a possibility of using thermionic target plates with inverse sheaths as an innovative divertor operating scenario. We derive an electron heat flux boundary condition for inverse sheaths and show that for given power exhaust into a tokamak scrape-off-layer, an inverse sheath leads to a much lower target plasma electron temperature than a conventional sheath. Low enough target plasma temperatures for radiative divertor detachment could therefore be achieved using inverse sheaths instead of the usual need to inject neutral atoms that compromise the core plasma. Other advantages of inverse sheath detachment over conventional sheath operating scenarios include (a) ion impact energies are as low as possible, minimizing sputtering and tritium implantation, (b) surface recombination heat flux is reduced due to ion flux reduction, and (c) arcs are inhibited due to the sign of the surface electric field. This paper outlines the basic properties of inverse sheath detachment and considers the feasibility of implementation. We offer recommendations for future modeling efforts needed to better understand the effects of thermionic emission in tokamaks and whether inverse sheaths present a viable divertor solution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress in the development of an ultrafast pulsed ponderomotive phase plate for cryo-electron tomography

Cryo-electron tomography (cryo-ET) is a powerful modality for resolving cellular structures in their native state. While single-particle cryo-electron microscopy excels in determining protein structures purified from recombinant or endogenous sources due to an abundance of particles, weak contrast issues are accentuated in cryo-ET by low copy numbers in crowded cellular milieux. Continuous laser phase plates offer improved contrast in cryo-ET; however, their implementation demands exceptionally high-peak optical intensities. Instead, a novel experimental approach to enhance contrast in cryo-ET is to manipulate the phase of scattered pulsed electrons using ultrafast pulsed photons. Here, we outline the experimental design of a proof-of-concept electron microscope and demonstrate synchronization between electron packets and laser pulses. Furthermore, we show ultrabright photoemission of electrons from an alloy field emission tip using femtosecond ultraviolet pulses. These experiments pave the way toward exploring the utility of the ponderomotive effect using pulsed radiation to increase phase contrast in cryo-ET of subcellular protein complexes in situ, thus advancing the field of cell biology.

Du, Daniel X. [Columbia Univ., New York, NY (Unite↗

A cryogenic continuously rotating half-wave plate mechanism for the POLARBEAR-2b cosmic microwave background receiver

In this report we present the design and laboratory evaluation of a cryogenic continuously rotating half-wave plate (CHWP) for the POLARBEAR-2b (PB-2b) cosmic microwave background receiver, the second installment of the Simons Array. PB-2b will observe at 5200 m elevation in the Atacama Desert of Chile in two frequency bands centered at 90 GHz and 150 GHz. In order to suppress atmospheric 1/f noise and mitigate systematic effects that arise when differencing orthogonal detectors, PB-2b modulates linear sky polarization using a CHWP rotating at 2 Hz. The CHWP has a 440 mm clear aperture diameter and is cooled to ≈50 K in the PB-2b receiver cryostat. It consists of a low-friction superconducting magnetic bearing and a low-torque synchronous electromagnetic motor, which together dissipate < 2 W. During cooldown, a grip-and-release mechanism centers the rotor to < 0.5 mm, and during continuous rotation, an incremental optical encoder measures the rotor angle with a noise level of 0.1 μrad/Hz. We discuss the experimental requirements for the PB-2b CHWP, the designs of its various subsystems, and the results of its evaluation in the laboratory. The presented CHWP has been deployed to Chile and is expected to see first light on PB-2b in 2020 or 2021.

47 OTHER INSTRUMENTATION↗

X-ray imaging of Rayleigh–Taylor instabilities using Fresnel zone plate at the National Ignition Facility

Being able to provide high-resolution x-ray radiography is crucial in order to study hydrodynamic instabilities in the high-energy density regime at the National Ignition Facility (NIF). Current capabilities limit us to about 20 μm resolution using pinholes, but recent studies have demonstrated the high-resolution capability of the Fresnel zone plate optics at the NIF, measuring 2.3 μm resolution. Using a zinc Heα line at 9 keV as a backlighter, we obtained a radiograph of Rayleigh–Taylor instabilities with a measured resolution of under 3 μm. Two images were taken with a time integrated detector and were time gated by a laser pulse duration of 600 ps, and a third image was taken with a framing camera with a 100 ps time gate on the same shot and on the same line of sight. The limiting factors on image quality for these two cases are the motion blur and the signal to noise ratio, respectively. We also suggest solutions to increase the image quality.

Do, A. (ORCID:0000000174372147)↗

Effects of divertor electrical drifts on particle distribution and detachment near the divertor target plate in DIII-D

Strong impacts of drifts on the divertor plasma in–out asymmetry and detachment are demonstrated in DIII-D with an open divertor configuration. For forward toroidal field, B T , i.e., with the ion B × ∇B drift toward the divertor, the particle flux to the inner divertor, as represented by the Langmuir probe measured ion saturation current (J sat ), exhibits a double peak structure, with electron temperature, lower at the inner target. Reversing the B T direction reverses both the radial and poloidal E × B flows, leading to a broad particle flux profile in the outboard scrape-off layer (SOL) with a similar double-peak structure to that observed at the inner target with forward B T . The correlation of a double peak structure with divertor temperature profiles confirms physical coupling between the drift flow and sheath boundary condition and their strong impact on divertor profiles. In addition, under reversed B T conditions, increasing the density flattens the target temperature profile. However, J sat remains high away from the strike point, rendering it difficult to achieve an “effective” detached plasma, i.e., with effective reduction in both peak heat flux and peak temperature (in the far SOL). In contrast, divertor detachment with a cold and flat temperature profile can be achieved at both target plates with the forward B T .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced laser-energy coupling with small-spot distributed phase plates (SG5-650) in OMEGA DT cryogenic target implosions

Cryogenic deuterium–tritium ice target implosions on OMEGA with new small-spot (SG5-650) distributed phase plates (DPPs) achieved an (11 ± 4)% increase in energy coupling compared to implosions with larger-spot SG5-850 DPPs by decreasing the ratio of the laser spot diameter to the target diameter from 0.93 to 0.75. The SG5-650 DPPs provide a focus spot size of 674 μm, which is defined as the diameter that encircles 95% of the measured beam energy compared to 834 μm for the SG5-850, which are the standard DPPs in cryogenic target implosions on OMEGA. The hydrodynamic efficiency, defined as the ratio of the kinetic energy in the imploding shell to the laser energy, increased from 4.5% to 5.0% based on radiation-hydrodynamic calculations benchmarked to shell trajectory and bang-time measurements. Furthermore, the higher coupling came with a trade-off of an increased hot-electron production as well as increased hydrodynamic instabilities seeded by a larger mode-10 amplitude from the beam port geometry, both of which may have reduced the fusion neutron production and areal density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Contrast optimization of Fresnel zone plate imaging

Fresnel zone plates (FZPs) are circular diffractive elements that operate as a lens for x-rays. They have gained interest in the field of laser-plasma physics due to their ability to achieve higher spatial resolution than pinholes. Their design and implementation are complicated by the fact that a significant amount of the x-rays passing through the FZP will not diffract (zeroth order) and present a background to the measurement. This background can be large and inhomogeneous depending on the geometric setup of the experiment. Furthermore, we present calculations of the diffracted (first order) and un-diffracted (zeroth order) flux profiles, which makes it possible to optimize the contrast between the first order imaging rays and the zeroth order background. Calculations for the implementation of a central block in the FZP, designed to block the zeroth from the entire field of view, are also presented.

47 OTHER INSTRUMENTATION↗

The Simons Observatory: Cryogenic half wave plate rotation mechanism for the small aperture telescopes

We present the requirements, design, and evaluation of the cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory (SO). SO is a cosmic microwave background polarization experiment at Parque Astronómico de Atacama in northern Chile that covers a wide range of angular scales using both small (Ø0.42 m) and large (Ø6 m) aperture telescopes. In particular, the small aperture telescopes (SATs) focus on large angular scales for primordial B-mode polarization. To this end, the SATs employ a CHWP to modulate the polarization of the incident light at 8 Hz, suppressing atmospheric 1/f noise and mitigating systematic uncertainties that would otherwise arise due to the differential response of detectors sensitive to orthogonal polarizations. The CHWP consists of a 505 mm diameter achromatic sapphire HWP and a cryogenic rotation mechanism, both of which are cooled down to ~50 K to reduce detector thermal loading. Under normal operation, the HWP is suspended by a superconducting magnetic bearing and rotates with a constant 2 Hz frequency, controlled by an electromagnetic synchronous motor. We find that the number of superconductors and the number of magnets that make up the superconducting magnetic bearing are important design parameters, especially for the rotation mechanism’s vibration performance. The rotation angle is detected through an angular encoder with a noise level of 0.07 μrad √ $\overline{s}$. During a cooldown process, the rotor is held in place by a grip-and-release mechanism that serves as both an alignment device and a thermal path. In this paper, we provide an overview of the SO SAT CHWP: its requirements, hardware design, and laboratory performance.

47 OTHER INSTRUMENTATION↗

Acoustoelastic characterization of plates using zero group velocity Lamb modes

Acoustoelasticity, a characteristic of material anharmonicity, gives rise to a link between wave propagation velocity and the stress state in materials. Ultrasonic techniques to monitor this coupling, particularly with high sensitivity and in a noncontact manner, can have widespread application both in the quantification of applied and residual stress and in the characterization of nonlinear material behavior through measurement of higher order elastic constants. Here, we use a laser ultrasonic technique to excite and detect zero group velocity (ZGV) Lamb wave resonances in aluminum plates under uniaxial loading. A laser line source is used to excite these resonances at different orientations with respect to the applied load, and the signals are detected using an interferometer. The effects of stress and source orientation on ZGV resonance frequencies are validated using the theory of acoustoelastic Lamb wave propagation. In addition, a model-based inversion technique is used to extract Murnaghan's third-order elastic constants from measurements of the stress dependence of the first two ZGV modes generated parallel and perpendicular to the applied load. Laser generation and detection of ZGV resonances is shown to be an effective and powerful approach for the noncontact and nondestructive acoustoelastic characterization of elastic waveguides.

36 MATERIALS SCIENCE↗

Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates

Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.

Instruments & Instrumentation↗

Characterization of the image plate multi-scan response to mono-energetic x-rays

Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.

Instruments & Instrumentation↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

LAMOST Time-Domain survey: first results of four K2 plates

From Oct. 2019 to Apr. 2020, LAMOST performed a time-domain (TD) spectroscopic survey of four K2 plates with both low- and medium-resolution observations. The low-resolution spectroscopic survey acquired 282 exposures ( ≈ 46.6 h) over 25 nights, yielding a total of about 767 000 spectra, and the medium-resolution survey took 177 exposures ( ≈ 49.1 h) over 27 nights, collecting about 478 000 spectra. More than 70%/50% of low-resolution/medium-resolution spectra have signal-to-noise ratio higher than 10. We determine stellar parameters (e.g., T eff , log g, [Fe/H]) and radial velocity (RV) with different methods, including LASP, DD-Payne and SLAM. In general, these parameter estimations from different methods show good agreement, and the stellar parameter values are consistent with those of APOGEE. We use the Gaia DR2 RV values to calculate a median RV zero point (RVZP) for each spectrograph exposure by exposure, and the RVZP-corrected RVs agree well with the APOGEE data. The stellar evolutionary and spectroscopic masses are estimated based on the stellar parameters, multi-band magnitudes, distances and extinction values. Finally, we construct a binary catalog including about 2700 candidates by analyzing their light curves, fitting the RV data, calculating the binarity parameters from medium-resolution spectra and cross-matching the spatially resolved binary catalog from Gaia EDR3. In conclusion, the LAMOST TD survey is expected to represent a breakthrough in various scientific topics, such as binary systems, stellar activity, stellar pulsation, etc.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-Anode Square Microchannel Plate Photomultiplier Tube

Photek has developed a high performance 4096-anode photomultiplier tube using microchannel plates as the gain medium. Additionally, the detector has been designed in a square format to maximise the active area and allow for easy tiling to cover large areas using multiple units. This paper analyses the detector performance in terms of gain and photocathode uniformity, single photon timing accuracy, count rate capability, cross talk and magnetic field susceptibility.

47 OTHER INSTRUMENTATION↗

Target development using the method of High-Intensity Vibrational Powder Plating (HIVIPP) at the Center for Accelerator Target Science (CATS) at Argonne National Laboratory (ANL)

One of the primary goals of the Center for Accelerator Target Science (CATS) is to provide targets and foils in support of the ATLAS User Facility and the Low-Energy community at large. While a wide array of target production techniques are available at CATS, new methods that must be explored invariably arise. One such technique, the High-Intensity Vibrational Powder Plating (HIVIPP), was first reported in 1997 by Isao Sugai. It was developed to produce targets and stripper foils that were difficult to make by standard methods. At Argonne National Laboratory (ANL), we have successfully constructed and tested a simple system for this purpose. We have produced targets of carbon and titanium on various metal backings using the HIVIPP method. We are currently in the exciting phase of exploring the production of other elements, including isotopically enriched and radioactive material. This work is in progress and will be further detailed with specific examples.

47 OTHER INSTRUMENTATION↗

Comprehensive earthquake catalogue update and spatiotemporal distribution analysis for Iraq and surrounding regions, northeastern Arabian Plate

The updated earthquake catalogue for Iraq covers the period from 1900 to the end of 2021 and includes over 37 000 recorded earthquakes. To create this comprehensive catalogue, five key steps were taken: compiling bulletins, calculating moment magnitudes, harmonizing magnitudes, establishing empirical conversion relations and evaluating the completeness of the catalogue. A notable enhancement in this update is the direct calculation of moment magnitudes for approximately 2800 earthquakes, achieved through the coda envelope technique and waveform data from the Mesopotamian Seismological Network (MPSN) in Iraq. This updated catalogue serves as a valuable resource for examining the spatiotemporal distribution of earthquakes, with respect to earthquake density, maximum moment magnitude and seismogenic depths. Additionally, the Gutenberg–Richter relationship was applied to calculate the a- and b-values specific to Iraq. The findings show that the Zagros Fold-Thrust Belt has a seismogenic layer (source) that ranges from 2 to 33 km deep and experiences high seismic activity. In contrast, the Mesopotamian Foredeep has a seismogenic layer ranging from 1 to 25 km deep and has lower seismic activity. The greatest seismic activity is concentrated around the Mandili-Badra-Teeb fault, which has experienced significant ruptures over time. The Outer Arabian Platform is identified as the main area of seismic activity, while additional activity occurs on the Inner Arabian Platform. Three major tectonic boundaries define the distribution of earthquakes in the northeastern Arabian Plate. These boundaries are defined by the Main Zagros Reverse Fault, the Zagros Foredeep Fault and the Anah Graben and Abu Jir-Euphrates Fault Zone. These boundaries highlight variations in seismicity levels and the spatial distribution of deformation in the region. The updated earthquake catalogue presented in this study is expected to play a vital role in regional seismicity assessments and seismic hazard analyses for Iraq and its surrounding areas.

58 GEOSCIENCES↗

On the nature of apparent transient sources on the National Geographic Society–Palomar Observatory Sky Survey glass copy plates

Abstract We examine critically recent claims for the presence of above-atmosphere optical transients in publicly available digitized scans of Schmidt telescope photographic plate material derived from the National Geographic Society–Palomar Observatory Sky Survey. We employ the publicly available SuperCOSMOS Sky Survey catalogues to examine statistically the morphology of the sources. We develop a simple, objective, and automated image classification scheme based on a random forest decision tree classifier. We find that the putative transients are likely to be spurious artefacts of the photographic emulsion. We suggest a possible cause of the appearance of these images as resulting from the copying procedure employed to disseminate glass copy survey atlas sets in the era before large-scale digitization programmes.

Hambly, N. C. (ORCID:0000000299019064)↗