Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRESSURE PULSE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Formation of a spherical plasma liner for plasma-jet-driven magneto-inertial fusion

Plasma-jet-driven magneto-inertial fusion is an alternative approach to controlled nuclear fusion, which aims to utilize a line-replaceable dense plasma liner as a repetitive spherical compression driver. In this experiment, first measurements of the formation of a spherical argon plasma liner formed from 36 discrete pulsed plasma jets are obtained on the Plasma Liner Experiment. Properties including liner uniformity and morphology, plasma density, temperature, and ram pressure are assessed as a function of time throughout the implosion process and indicate an apparent transition from initial kinetic inter-jet interpenetration to collisional regime near stagnation times, in accordance with theoretical expectation. A lack of primary shock structures between adjacent jets during flight implies that arbitrarily smooth liners may be formed by way of corresponding improvements in jet parameters and control. The measurements facilitate the benchmarking of computational models and understanding the scaling of plasma liners toward fusion-relevant energy density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reversible structural transformations in supercooled liquid water from 135 to 245 K

Water has many anomalous properties compared to “simple” liquids, and these anomalies are typically enhanced in supercooled water.1-3 While numerous models have been proposed, including the liquid-liquid critical point,4,5 the singularity-free scenario,6 and the stability limit conjecture,1 a molecular-level understanding remains elusive. The main difficulty in determining which, if any, of these models is correct is the limited amount of data in the relevant temperature and pressure ranges. For water at ambient pressures, which is the focus of this work, data is largely missing from 160 – 232 K (“No Man’s Land”) due to rapid crystallization.2,3 Whether rapid crystallization is just an experimental obstacle, or a fundamental problem signaling the inability of water to thermally equilibrate prior to crystallization is also a major unanswered question.5,7 Here, we investigate the structural transformations of transiently-heated, supercooled water with nanosecond time resolution using infrared vibrational spectroscopy. The experiments demonstrate three key results. First, water’s structure relaxes from its initial configuration to a “steady-state” configuration prior to the onset of crystallization over a wide temperature range. Second, water’s steady-state structure can be reproduced by a linear combination of two, temperature-independent structures that correspond to a “high-temperature liquid” and a “low-temperature liquid.” Third, the observed structural changes are reversible over the full temperature range. Taken together, these results show that supercooled water can equilibrate prior to crystallization for temperatures from the homogeneous nucleation temperature, TH ~232 K,3 down to the glass transition temperature (Tg ~ 136 K). Second, the results provide support for the hypothesis that supercooled water can be described as a mixture of two, structurally-distinct, interconvertible liquids from 135 K to 245 K.5,8-18

Kringle, Loni M.↗

Direct comparison of wire, foil, and hybrid X-pinches on a 200 kA, 150 ns current driver

Wire X-pinches (WXPs) have been studied comprehensively as fast (~1 ns pulse width), small (~1 μm) x-ray sources, created by twisting two or more fine wires into an “X” to produce a localized region of extreme magnetic pressure at the cross-point. Recently, two alternatives to the traditional WXP have arisen: the hybrid X-pinch (HXP), composed of two conical electrodes bridged by a thin wire or capillary, and the laser-cut foil X-pinch (LCXP), cut from a thin foil using a laser. We present a comparison of copper wire, hybrid, and laser-cut foil X-pinches on a single experimental platform: UC San Diego’s ~200 kA, 150 ns rise time GenASIS driver. All configurations produced 1–2 ns pulse width, ≤5 μm soft x-ray (Cu L-shell, ~1 keV) sources (resolutions diagnostically limited) with comparable fluxes. WXP results varied with linear mass and wire count, but consistently showed separate pinch and electron-beam-driven sources. LCXPs produced the brightest (~1 MW), smallest (≤5 μm) Cu K-shell sources, and spectroscopic data showed both H-like Cu K α lines indicative of source temperatures ≥2 keV, and cold K α (~8050 eV) characteristic of electron beam generated sources, which were not separately resolved on other diagnostics (within 1–2 ns and ≤200 μm). HXPs produced minimal K-shell emission and reliably single, bright, and small L-shell sources after modifications to shape the early current pulse through them. Benefits and drawbacks for each configuration are discussed to provide potential X-pinch users with the information required to choose the configuration best suited to their needs.

42 ENGINEERING↗

Vanishing dynamic strength measured in a transient high-pressure phase of tin

This work reports two independent experimental estimations of the dynamic strength of the body-centered tetragonal (bct) 𝛾 phase of tin, which occurs at pressures above about 9 GPa and transforms promptly back to the ambient 𝛽 phase upon pressure release. Measuring strength in such a transient high-pressure phase is challenging. One measurement used free-surface Richtmyer-Meshkov instabilities generated with gas gun impact. Another set of measurements used ramp-release loading in a pulsed-power facility. Strength estimations came from comparison to simulations using a comprehensive multiphase modeling framework that includes equation of state, shear moduli, and strength separately for each phase, and treats mixed-phase regions. Both experimental methods found the 𝛾-phase strength to be very low, within experimental uncertainty of zero. The existing literature on other materials, by contrast, almost universally reports higher strength in transient high-pressure phases compared with ambient phases. Recent Molecular-Dynamics simulations on tin in the literature showed almost zero deviatoric strength during a deformation-induced bct → bct transformation in which one of the 𝛾-phase 𝑎 axes “flips” to the 𝑐 axis. This reorientation currently provides the most plausible explanation for the low observed strength in 𝛾-phase tin.

36 MATERIALS SCIENCE↗

Spatially enhanced electric field induced second harmonic (SEEFISH) generation for measurements of electric field distributions in high-pressure plasmas

Abstract The spatial resolution of the ps electric field induced second harmonic (EFISH) generation has been enhanced by using non-collinear pump laser beam arrangements. The pump laser beam (1064 nm, nominal pulse duration 150 ps, pulse energy 20–40 mJ) is separated into two coaxial or crossing beams, overlapping only near the focal point. The spatially enhanced EFISH (SEEFISH) signal is generated over a shorter beam overlap region compared to the collinear beam arrangement. Blocking of either of the two beams results in a complete suppression of the signal. The signal is spatially isolated from the ‘conventional’ EFISH signal and measured by a photomultiplier detector. Measurements of a known Laplacian field generated between two parallel cylinder electrodes in ambient air shows that SEEFISH improves the spatial resolution of the measurements by up to a factor of 2, such that the measurement results agree with the Laplacian field distribution. The spatial resolution is improved further by reducing the focal distance of the lens. The magnitude of the SEEFISH signal is significantly lower compared to that of the single-beam EFISH and decreases rapidly as the beam crossing angle is increased, due to the phase mismatch. This approach has a significant potential for measurements of electric field distributions in high-pressure plasmas, with an additional benefit of removing the stray second harmonic signal from the optical access windows.

Physics↗

A pulsed-power implementation of “Laser Gate” for increasing laser energy coupling and fusion yield in magnetized liner inertial fusion (MagLIF)

Magnetized Liner Inertial Fusion (MagLIF) at Sandia National Laboratories involves a laser preheating stage,where a few-ns laser pulse passes through a few-micron-thick plastic window to preheat gaseous fusion fuel contained within the MagLIF target. Interactions with this window reduce heating e ciency and mix window and target materials into the fuel. A recently proposed idea called \Laser Gate" involves removing the window well before the preheating laser is applied. In this article, we introduce experimental proof-of-principle results for a pulsed-power implementation of Laser Gate, where a thin current-carrying wire weakens the perimeter of the window, allowing the fuel pressure to push the window open and away from the preheating laser path. For this e ort, transparent targets were fabricated and a test facility capable of studying this version of Laser Gate was developed. A 12-frame bright- eld laser schlieren/shadowgraphy imaging system captured the window opening dynamics on microsecond timescales. The images exhibit that the window remains largely intact as it opens and detaches from the target. A column of escaping pressurized gas appears to prevent the detached window from inadvertently moving into the preheating laser path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

The effect of plasma shaping on high density H-mode SOL profiles and fluctuations in TCV

Abstract The impact of plasma shaping on the properties of high density H-mode scrape-off layer (SOL) profiles and transport at the outer midplane has been investigated on Tokamakà configuration variable. The experimental dataset has been acquired by evolving the upper triangularity while keeping the other parameters constant. The scan comprises δ u p values between 0.0 and 0.6, excluding negative triangularity scenarios. Within this study, a transition from type-I edge localised modes to the quasi-continuous exhaust regime takes place from low to high δ u p . The modification of the upstream SOL profiles has been assessed, in terms of separatrix quantities, within the α t turbulence control parameter theoretical framework (Eich et al 2020 Nucl. Fusion 60 056016). The target parallel heat load and the upstream near-SOL density profiles have been shown to broaden significantly for increasing α t . Correspondingly, in the far SOL a density shoulder formation is observed when moving from low to high δ u p . These behaviours have been correlated with an enhancement of the SOL fluctuation level, as registered by wall-mounted Langmuir probes as well as the thermal helium beam diagnostic. Specifically, both the background and the filamentary-induced fluctuating parts of the first wall ion saturation current signal are larger at higher δ u p , with filaments being ejected more frequently into the SOL. Comparison of two pulses at the extremes of the δ u p scan range, but with otherwise same input parameters, shows that the midplane neutral pressure does not change much during the H-mode phase of the discharge. This indicates that indirect effects of the change in geometry, linked to first wall recycling sources, should not play a significant role. The total core radiation increases at high δ u p , on account of a stronger plasma–wall interaction and resulting larger carbon impurity intake from the first wall. This is likely associated to the enhanced first wall fluctuations, as well as a smaller outer gap and the close-to-double-null magnetic topology at high shaping.

Stagni, A. (ORCID:0000000180841544)↗

Pump Development for Fusion-Based Neutron Generators

Tritium usage in fusion-based neutron generators is low for each pulse. This requires the deuterium/tritium mixture to be evacuated and recycled during downtime or to remove the helium buildup. Because of the pressure ranges and to minimize space, turbomolecular pumps are being considered for the tritium recirculation pumps. Two main types were initially considered: Agilent TwisTorr and Osaka TG-MR.

Angelette, Lucas M. [Savannah River National Labor↗

Evaluating Transfer and Pumping of Slurries from Pulsed Jet Mixed Vessels

Due to gravity, solids in slurries will settle if density differences between the solids and liquid are positive (i.e., particle has a negative buoyant force) unless rheological properties and flow conditions are adequate to overcome the gravitational effects. The rate of settling depends on the force balance of the particle, which includes the surface forces associated with fluid rheology. Given the same fluid and solid properties, particles that are larger and denser tend to settle faster. When pumping slurry into a vessel at concentrations precluding hindered settling with insufficient mixing, particle and density distributions can result in preferential settling, creating stratification in the solids concentration within the vessel. For vessels with transfer line inlets located in the lower portion of the tank, the stratified solids concentration may be detrimental to the transfer system performance. Elevated concentrations of solids in the slurry entrained at the inlet to the transfer line can result in the effective viscosity or slurry bulk density exceeding the design limits of the pump. These conditions could result in plugging of the transfer line or onset of cavitation of the pumps because of excessive pressure drop. These conditions can be exacerbated with periodic inlet conditions existing at the transfer line inlet. Periodic conditions can result when vessel mixing is intermittent such as with pulsed jet mixers (PJM). The transfer line inlet conditions are impacted by the periodic nature of the PJM operations with respect to suspension of solids and their transport to the inlet of the transfer line. A scaling approach is presented, and corresponding test requirements are developed for assessing the prevention of plugging the pipeline. Line plugging mechanisms are addressed that do not include plugging due to steady-state high-density slurry entering the transfer line and reducing the net positive suction head available (NPSHA) at the pump inlet to below that required for pump operation. Items considered include the transition to reduced relative flow velocities, such that the critical pipe velocity for solids deposition, Ucd, is not maintained, and segregation of heavy solids during the transport. The recommended requirements to prevent plugging include: • Limits for viscosity and density for entrained slurry to prevent the pressure drop in the pipeline from exceeding pump capacity. • Limits for viscosity and density for entrained slurry to prevent the net positive suction head available (NPSHA) from falling below the net positive suction head required (NPSHR) for operating the pump. • Transfer line velocity and flow rate requirements to maintain solids in suspension, while avoiding line plugging that results from deposition of solids within the transfer line. This paper describes the development of the scaling and testing requirements to verify that proposed approaches for transfer and pump out are appropriately developed

periodic flow, mixing, pipeline plugging, scaling,↗

Microsized Pore Structure Determination in EPDM Rubbers Using High-Pressure 129 Xe NMR Techniques

Microsized pore parameters, such as pore size and distance between pores in a series of model EPDM rubbers, were determined in situ under the pressure of 500 psi using 129 Xe nuclear magnetic resonance (NMR) techniques: spin–lattice (T 1 ) and spin–spin (T 2 ) relaxation measurements, pulsed-field gradient (PFG) NMR, and two-dimensional exchange spectroscopy (2D EXSY). The T 1 /T 2 (>>1) ratio for the xenon confined in the pores is larger than that for nonconfined free xenon. This suggests that almost the entire pore surface interacts with xenon atoms like a closed pore. While these pores still connect each other through very narrow diffusion/exchange channels, it is possible to observe the echo decay in PFG-NMR and cross-peaks in 2D EXSY. The results show that both diffusion (D pore ≈ 2.1 × 10 –10 m 2 /s) and exchange (exchange rate, τ exch = a few tens of milliseconds) of xenon between a pore within the material and outer surface are prolonged. The exchange distances (l), which correspond to the xenon gas penetration depth, were estimated to be 70–100 μm based on the measured diffusion coefficients and exchange rate (1/τ exch ). NMR diffraction analysis reveals that pore size (a) and pore distance (b) are on the order of magnitude of micrometers and tens of micrometers, while the diffusion coefficients of xenon gas in the diffusion channels (D eff ) are about 10 –8 m 2 /s. Overall, this study suggests that the pores with a few micrometers connected through very narrow flowing channels with the length of several tens of micrometers are developed 70 to 100 μm below the rubber surface. Furthermore, the overall steady-state diffusion of xenon is slower, approximately 2 orders of magnitudes, than the diffusion in the channel between the pores. Finally, the pore and exchange distances correlated with the composition of rubbers showed that the properties of EPDM rubber as a high-pressure gas barrier could be improved by reducing the size of cracks and the depth of gas penetration by the addition of both carbon black and silica fillers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Techniques for studying materials under extreme states of high energy density compression

The properties of materials under extreme conditions of pressure and density are of key interest to a number of fields, including planetary geophysics, materials science, and inertial confinement fusion. In geophysics, the equations of state of planetary materials, such as hydrogen and iron, under ultrahigh pressure and density provide a better understanding of their formation and interior structure [Celliers et al., “Insulator-metal transition in dense fluid deuterium,” Science 361, 677–682 (2018) and Smith et al., “Equation of state of iron under core conditions of large rocky exoplanets,” Nat. Astron. 2, 591–682 (2018)]. The processes of interest in these fields occur under conditions of high pressure (100 GPa–100 TPa), high temperature (>3000 K), and sometimes at high strain rates (>103 s−1) depending on the process. With the advent of high energy density (HED) facilities, such as the National Ignition Facility (NIF), Linear Coherent Light Source, Omega Laser Facility, and Z, these conditions are reachable and numerous experimental platforms have been developed. To measure compression under ultrahigh pressure, stepped targets are ramp-compressed and the sound velocity, measured by the velocity interferometer system for any reflector diagnostic technique, from which the stress-density of relevant materials is deduced at pulsed power [M. D. Knudson and M. P. Desjarlais, “High-precision shock wave measurements of deuterium: Evaluation of exchange-correlation functionals at the molecular-to-atomic transition,” Phys. Rev. Lett. 118, 035501 (2017)] and laser [Smith et al., “Equation of state of iron under core conditions of large rocky exoplanets,” Nat. Astron. 2, 591–682 (2018)] facilities. To measure strength under high pressure and strain rates, experimenters measure the growth of Rayleigh–Taylor instabilities using face-on radiography [Park et al., “Grain-size-independent plastic flow at ultrahigh pressures and strain rates,” Phys. Rev. Lett. 114, 065502 (2015)]. The crystal structure of materials under high compression is measured by dynamic x-ray diffraction [Rygg et al., “X-ray diffraction at the national ignition facility,” Rev. Sci. Instrum. 91, 043902 (2020) and McBride et al., “Phase transition lowering in dynamically compressed silicon,” Nat. Phys. 15, 89–94 (2019)]. Medium range material temperatures (a few thousand degrees) can be measured by extended x-ray absorption fine structure techniques, Yaakobi et al., “Extended x-ray absorption fine structure measurements of laser-shocked V and Ti and crystal phase transformation in Ti,” Phys. Rev. Lett. 92, 095504 (2004) and Ping et al., “Solid iron compressed up to 560 GPa,” Phys. Rev. Lett. 111, 065501 (2013), whereas more extreme temperatures are measured using x-ray Thomson scattering or pyrometry. This manuscript will review the scientific motivations, experimental techniques, and the regimes that can be probed for the study of materials under extreme HED conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synthesis and composition control of epitaxial FeWO4 thin films using pulsed laser deposition

We report the growth of epitaxial FeWO4 thin films on c-plane sapphire via pulsed laser deposition using a Fe 2 O 3 /WO 3 target ablated in an O 2 atmosphere. At a constant O 2 pressure of 1 mTorr, x-ray diffraction (XRD) confirms FeWO 4 as the major crystalline phase for substrate temperatures from 500 to 800 °C. As temperature increases, x-ray fluorescence (XRF) shows the Fe/W ratio remains nearly constant at 0.90 ± 0.02, while x-ray photoelectron spectroscopy (XPS) shows Fe 3+ to Fe 2+ conversion increases from 20% to 35%. Morphological analysis reveals phase separation, likely of amorphous Fe 3+ oxide from crystalline FeWO 4 , increasing with Fe 3+ conversion. This is attributed to an O-rich laser ablated flux, where conversion is driven by the Arrhenius temperature dependence of Fe 3+ → Fe 2+ reduction on the film surface. At a constant substrate temperature of 750 °C, XRD confirms FeWO 4 formation for O 2 pressures from 0.5 to 10 mTorr. As pressure increases, XRF shows the Fe/W ratio decreases from 0.98 to 0.70, while XPS shows Fe 3+ conversion rises from 15% to 70%. Morphology shows phase separation decreasing with increasing Fe 3+ conversion. This is attributed to scattering, where higher O 2 pressure makes the laser ablated flux O-deficient relative to Fe and W, facilitating Fe 2+ formation. Films with Fe 3+ conversion above ∼30% and Fe/W ratios from 0.86 to 0.96 exhibit FeWO 4 optical and electronic properties suitable for photoanode applications.

36 MATERIALS SCIENCE↗

Size-tunable silver nanoparticle synthesis in glycerol driven by a low-pressure nonthermal plasma

Silver nanoparticles (NPs) are extensively used in electronic components, chemical sensors, and disinfection applications, in which many of their properties depend on particle size. However, control over silver NP size and morphology still remains a challenge for many synthesis techniques. Here, in this work, we demonstrate the surfactant-free synthesis of silver NPs using a low-pressure inductively coupled nonthermal argon plasma. Continuously forming droplets of silver nitrate (AgNO 3 ) precursor dissolved in glycerol are exposed to the plasma, with the droplet residence time being determined by the precursor flow rate. Glycerol has rarely been studied in plasma-liquid interactions but shows favorable properties for controlled NP synthesis at low pressure. We show that the droplet residence time and plasma power have strong influence on NP properties, and that improved size control and particle monodispersity can be achieved by pulsed power operation. Silver NPs had mean diameters of 20 nm with geometric standard deviations of 1.6 under continuous wave operation, which decreased to 6 nm mean and 1.3 geometric standard deviation for pulsed power operation at 100 Hz and 20% duty cycle. We propose that solvated electrons from the plasma and vacuum ultraviolet (VUV) radiation induced electrons produced in glycerol are the main reducing agents of Ag + , the precursor for NPs, while no significant change of chemical composition of the glycerol solvent was detected.

36 MATERIALS SCIENCE↗

Shock-induced twinning/detwinning and spall failure in Cu–Ta nanolaminates at atomic scales

Here, this study provides new insights into the role of interfaces on the deformation and failure mechanisms in shock-loaded Cu–Ta–Cu trilayer system. The thickness of the Ta layer, piston velocities, and shock pulse durations were varied to explore the impact of impedance mismatch and loading conditions on spallation behavior and twin formation. It was found that the interfaces play a crucial role in the dynamic response of these multilayered systems since secondary reflection waves generated at the interfaces significantly affected the peak stress and pressure profiles, influencing void nucleation and failure modes. In the trilayer systems, failure predominantly occurred at interfaces and within the Ta layer, with void nucleation sites and twinning behavior being markedly different compared to single-crystal Cu and Ta. Increasing the Ta layer thickness modified the wave interactions, leading to different failure locations. Higher piston velocities were associated with increased spall strength by enhancing wave interactions and void formation, particularly at the interfaces and within the Ta layer, under specific configurations. Additionally, shorter shock pulse durations facilitated earlier initiation of the release fan, reducing twin formation and altering the failure dynamics by accelerating twin annihilation and pressure release.

36 MATERIALS SCIENCE↗

Role of the Porras factor in phase matching of high-order harmonic generation driven by focused few-cycle laser pulses

We investigate the role of the Porras factor (or laser focusing effect) on the macroscopic high-order harmonic generation (HHG) driven by a focused broadband few-cycle laser beam. By employing a non-adiabatic phase-matching analysis method, we reveal that phase mismatch due to the induced-dipole phase varies with the Porras factor, which is dominant in phase matching at low gas pressure. We also find that in a strongly ionized medium when gas pressure is high, the nonlinear propagation is dominated by a plasma effect such that the focusing effect is mitigated, resulting in similar poor phase matching of HHG regardless of the Porras factor. Our results are expected to assist experimentalists identifying optimal conditions for HHG using ultrashort laser pulses.

Optics↗

Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. Here, we review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. Finally, we summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.

47 OTHER INSTRUMENTATION↗

Direct Injection of Biomineralizing Agents to Restore Injectivity and Wellbore Integrity

Summary In this manuscript, we describe the second of two field demonstrations of microbially induced calcium carbonate precipitation (MICP) performed in a failed waterflood injection well in Indiana. In 2012, fracture-related flow pathways developed in the wellbore cement, causing injection water to bypass the oil-bearing formation and enter a high-permeability sandstone thief zone, thereby substantially decreasing injection pressure. In the first field demonstration, our study team characterized the well's mode of failure and successfully applied MICP to decrease flow through the defective cement. However, because the MICP treatment was conducted using a bailer delivery system, the degree of permeability reduction achievable was not adequate to fully restore the historic injection pressure of 1,400 psi at 1 gal/min. For the second field demonstration (reported herein), a direct injection system was developed that substantially increased the injection volume of MICP-promoting fluids. Two strategies were implemented to produce more ureolytic microbes: resuspending concentrated frozen cells immediately before injection and scaling up the bioreactor growth capacity. Multiple pulses of microbes and urea-calcium media were pumped into a string of 1-in.-diameter tubing separated by brine spacers and injected continuously at a flow rate of 3.4 to 1.4 gal/min. During the third day of injection, an injection pressure of 1,384 psi at a flow rate of 1.4 gal/min was achieved, and the experiment was terminated. This study demonstrates that MICP can be successfully used in large-volume applications where the time frame for the delivery of reactants is limited. This finding has significant relevance for commercialization of the MICP biotechnology in the oil and gas industry.

Engineering↗