Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROSTATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

WE-EF-210-07: Development of a Minimally Invasive Photo Acoustic Imaging System for Early Prostate Cancer Detection

Purpose: The objective of this work is to design, implement and characterize a catheter-based ultrasound/photoacoustic imaging probe for early-diagnosis of prostate cancer and to aid in image-guided radiation therapy. Methods: The need to image across 6–10cm of tissue to image the whole prostate gland limits the resolution achievable with a transrectal ultrasound approach. In contrast, the urethra bisects the prostate gland, providing a minimally invasive pathway for deploying a high resolution ultrasound transducer. Utilizing a high-frequency (20MHz) ultrasound/photoacoustic probe, high-resolution structural and molecular imaging of the prostate tissue is possible. A custom 3D printed probe containing a high-frequency single-element ultrasound transducer is utilized. The diameter of the probe is designed to fit inside a Foley catheter and the probe is rotated around the central axis to achieve a circular B-scan. A custom ultrasound amplifier and receiver was set up to trigger the ultrasound pulse transmission and record the reflected signal. The reconstructed images were compared to images generated by traditional 5 MHz ultrasound transducers. Results: The preliminary results using the high-frequency ultrasound probe show that it is possible to resolve finely detailed information in a prostate tissue phantom that was not achievable with previous low-frequency ultrasound systems. Preliminary ultrasound imaging was performed on tissue mimicking phantom and sensitivity and signal-to-noise ratio of the catheter was measured. Conclusion: In order to achieve non-invasive, high-resolution, structural and molecular imaging for early-diagnosis and image-guided radiation therapy of the prostate tissue, a transurethral catheter was designed. Structural/molecular imaging using ultrasound/photoacoustic of the prostate tissue will allow for localization of hyper vascularized areas for early-stage prostate cancer diagnosis.

60 APPLIED LIFE SCIENCES↗

SU-F-J-171: Robust Atlas Based Segmentation of the Prostate and Peripheral Zone Regions On MRI Utilizing Multiple MRI System Vendors

Purpose: Automatically generated prostate MRI contours can be used to aid in image registration with CT or ultrasound and to reduce the burden of contouring for radiation treatment planning. In addition, prostate and zonal contours can assist to automate quantitative imaging features extraction and the analyses of longitudinal MRI studies. These potential gains are limited if the solutions are not compatible across different MRI vendors. The goal of this study is to characterize an atlas based automatic segmentation procedure of the prostate collected on MRI systems from multiple vendors. Methods: The prostate and peripheral zone (PZ) were manually contoured by an expert radiation oncologist on T2-weighted scans acquired on both GE (n=31) and Siemens (n=33) 3T MRI systems. A leave-one-out approach was utilized where the target subject is removed from the atlas before the segmentation algorithm is initiated. The atlas-segmentation method finds the best nine matched atlas subjects and then performs a normalized intensity-based free-form deformable registration of these subjects to the target subject. These nine contours are then merged into a single contour using Simultaneous Truth and Performance Level Estimation (STAPLE). Contour comparisons were made using Dice similarity coefficients (DSC) and Hausdorff distances. Results: Using the T2 FatSat (FS) GE datasets the atlas generated contours resulted in an average DSC of 0.83±0.06 for prostate, 0.57±0.12 for PZ and 0.75±0.09 for CG. Similar results were found when using the Siemens data with a DSC of 0.79±0.14 for prostate, 0.54±0.16 and 0.70±0.9. Contrast between prostate and surrounding anatomy and between the PZ and CG contours for both vendors demonstrated superior contrast separation; significance was found for all comparisons p-value < 0.0001. Conclusion: Atlas-based segmentation yielded promising results for all contours compared to expertly defined contours in both Siemens and GE 3T systems providing fast and automatic segmentation of the prostate. Funding Support, Disclosures, and Conflict of Interest: AS Nelson is a partial owner of MIM Software, Inc. AS Nelson, and A Swallen are current employees at MIM Software, Inc.

60 APPLIED LIFE SCIENCES↗

SU-F-T-40: Can CBCT Images Be Used for Volume Studies of Prostate Seed Implants for Boost Treatment?

Purpose: In our clinic, the planning CT is used for definitive and boost low-dose-rate (LDR) brachytherapy treatments to determine the ultrasound volume in the operating room (OR) at the time of the implant. While the CT overestimation of OR volume is known, a larger estimation discrepancy has been observed for boost treatments. A possible reason is the prostate size reduction during EBRT for boost patients. Since cone-beam CT (CBCT) is often used as routine imaging guidance of EBRT, this prostate volume change may be captured. This study investigates if CBCT taken during EBRT includes the volume change information and therefore beats CT in estimating the prostate OR volumes. Methods: 9 prostate patients treated with EBRT (45Gy in 1.8Gy per fractions to the whole pelvis) and I-125 seed implants (108Gy) were involved in this study. During EBRT, CBCT image guidance was performed on a weekly basis. For each patient, the prostate volumes on the first and the last available CBCT images were manually contoured by a physician. These volumes were then compared to each other and with the contoured volumes from the planning CT and from the ultrasound images in the OR. Results: The first and the last CBCT images did not show significant prostate volume change. Their average +/− standard deviation of prostate volumes were 24.4cc+/−14.6cc and 29.9cc+/−16.1cc, respectively (T-test p=0.68). The ratio of the OR volume to the last CBCT (0.71+/−0.21) was not significantly different from the ratio of OR volumes to the planning CT (0.61+/−0.13) (p=0.25). Conclusion: In this study, CBCT does not show significant prostate volume changes during EBRT. CBCT and CT volumes are quite consistent and no improvement of volume estimation using CBCT is observed. The advantage of CBCT as a replacement of CT for volume study of boost LDR brachytherapy is limited.

60 APPLIED LIFE SCIENCES↗

SU-F-T-44: A Comparison of the Pre-Plan, Intra-Operative Plan, and Post-Implant Dosimetry for a Prostate Implant Case Using Prefabricated Linear Polymer-Encapsulated Pd-103

Purpose: To investigate the reproducibility and limitations of Pd-103 prostate brachytherapy using fixed length linear sources (CivaString). Methods: An LDR prostate brachytherapy case which was preplanned on MR images with prefabricated linear polymer-encapsulated Pd-103 sources (CivaString) was studied and compared with ultrasound based intra-operative planning and CT based post-implant dosimetry. We evaluated the following parameters among the three studies: prostate geometry (volume and cross sectional area), needle position and alignment deviations, and dosimetry parameters (D90). Results: The prostate volumes and axial cross sectional areas at center of prostate were measured as 41.8, 39.3 and 36.8 cc, and 14.9, 14.3, and 11.3 respectively on pre-plan MR, inter-op US, and post-implant CT studies. The deviation of prostate volumes and axial cross sectional areas measured on pre-planning MR and intra-operative US were within 5%. 17 out of 19 pre-planned needles were positioned within 5mm (the template grid size). One needle location was adjusted intra-operatively and another needle was removed due to proximity to urethra. The needle pathways were not always parallel to the trans-rectal probe due to the flexibility of CivaString. The angle of deviation was up to 10 degrees. Two pairs of needles were exchanged to better fit the length of prostate at the time of implant. This resulted in a prostate D90 of 153.8 Gy (124%) and 131.4 Gy (106.7%) for intra-op and PID respectively. Conclusion: Preplanning is a necessary part of implants performed with prefabricated linear polymer sources. However, as is often the case, there were real-time deviations from the pre-plan. Intra-op planning provides the ability conform to anatomy at the time of implant. Therefore, we propose to develop a systematic way to order extra strings of different length to provide the flexibility to perform intra-operative planning with fixed length strands.

60 APPLIED LIFE SCIENCES↗

SU-G-BRA-12: Development of An Intra-Fractional Motion Tracking and Dose Reconstruction System for Adaptive Stereotactic Body Radiation Therapy in High-Risk Prostate Cancer

Purpose: A clinical trial on stereotactic body radiation therapy (SBRT) for high-risk prostate cancer is undergoing at our institution. In addition to escalating dose to the prostate, we have increased dose to intra-prostatic lesions. Intra-fractional prostate motion deteriorates well planned radiation dose, especially for the small intra-prostatic lesions. To solve this problem, we have developed a motion tracking and 4D dose-reconstruction system to facilitate adaptive re-planning. Methods: Patients in the clinical trial were treated with VMAT using four arcs and 10 FFF beam. KV triggered x-ray projections were taken every 3 sec during delivery to acquire 2D projections of 3D anatomy at the direction orthogonal to the therapeutic beam. Each patient had three implanted prostate markers. Our developed system first determined 2D projection locations of these markers and then 3D prostate translation and rotation via 2D/3D registration of the markers. Using delivery log files, our GPU-based Monte Carlo tool (goMC) reconstructed dose corresponding to each triggered image. The calculated 4D dose distributions were further aggregated to yield the delivered dose. Results: We first tested each module in our system. MC dose engine were commissioned to our treatment planning system with dose difference of <0.5%. For motion tracking, 1789 kV projections from 7 patients were acquired. The 2D marker location error was <1 mm. For 3D motion tracking, root mean square (RMS) errors along LR, AP, and CC directions were 0.26mm, 0.36mm, and 0.01mm respectively in simulation studies and 1.99mm, 1.37mm, and 0.22mm in phantom studies. We also tested the entire system workflow. Our system was able to reconstruct delivered dose. Conclusion: We have developed a functional intra-fractional motion tracking and 4D dose re-construction system to support our clinical trial on adaptive high-risk prostate cancer SBRT. Comprehensive evaluations have shown the capability and accuracy of our system.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-09: Impact of Interfractional Motion On Hypofractionated Pencil Beam Scanning Proton Therapy for Prostate Cancer

Purpose: To investigate the impact of anatomy/setup variations on standard vs. hypofractionated anterolateral pencil beam scanning (PBS) proton therapy for prostate cancer. Methods: Six prostate cancer patients treated with double-scattering proton therapy, who underwent weekly verification CT scans were selected. Implanted fiducials were used for localization, and endorectal balloons for immobilization. New PBS plans using combination of lateral and anterior-oblique (AO) (±35 deg) beams were created. AO beams were added to spare the femoral heads during hypofractionation. Lateral beams delivered 50.4 Gy(RBE) to prostate plus 5-15mm of seminal vesicles and AO beams 28.8 Gy(RBE) to prostate, in 44 fractions. PTV was laterally expanded by 2.5% to account for range uncertainty. No range margins were applied for AO beams, assuming delivery with in-vivo range verification. Field-specific apertures with 1.2cm margin were used. Spot size was ∼9.5mm sigma for 172MeV @isocenter in air. Plans were optimized as single-field-uniform-dose with ∼5% maximum non-uniformity. The planned dose was recomputed on each weekly CT after aligning the fiducials with the simulation CT, scaled and accumulated via deformable image registration. Hypofractionated treatments with 12 and 5 fractions were considered. Equivalent doses were calculated for prostate (α/β= 1.5Gy), bladder and rectum (α/β= 3Gy). Results: The biological equivalent prostate dose was 86.2 and 92.9 Gyeq for the hypofractionation scenarios at 4.32 and 7.35 Gy/fx, respectively. The equivalent prostate D98 was degraded by on average 2.7 Gyeq for standard, and 3.1 and 4.0 Gyeq for the hypofractionated plans after accumulation. Differences between accumulated and planned Dmean/D2/EUD were generally reduced when reducing the number of fractions for bladder and rectum. The average Dmean/D2/EUD differences over all patients and organs-at-risk were 0.74/4.0/9.23, 0.49/3.64/5.51, 0.37/3.21/3.49 Gyeq for 44, 12 and 5 fractions. Conclusion: Hypofractionation makes proton therapy of prostate more susceptible to interfractional motion-induced target dose degradation compared to the standard fractionation.

60 APPLIED LIFE SCIENCES↗

COMPACT CdZnTe-BASED GAMMA CAMERA FOR PROSTATE CANCER IMAGING

In this paper, we discuss the design of a compact gamma camera for high-resolution prostate cancer imaging using Cadmium Zinc Telluride (CdZnTe or CZT) radiation detectors. Prostate cancer is a common disease in men. Nowadays, a blood test measuring the level of prostate specific antigen (PSA) is widely used for screening for the disease in males over 50, followed by (ultrasound) imaging-guided biopsy. However, PSA tests have a high false-positive rate and ultrasound-guided biopsy has a high likelihood of missing small cancerous tissues. Commercial methods of nuclear medical imaging, e.g. PET and SPECT, can functionally image the organs, and potentially find cancer tissues at early stages, but their applications in diagnosing prostate cancer has been limited by the smallness of the prostate gland and the long working distance between the organ and the detectors comprising these imaging systems. CZT is a semiconductor material with wide band-gap and relatively high electron mobility, and thus can operate at room temperature without additional cooling. CZT detectors are photon-electron direct-conversion devices, thus offering high energy-resolution in detecting gamma rays, enabling energy-resolved imaging, and reducing the background of Compton-scattering events. In addition, CZT material has high stopping power for gamma rays; for medical imaging, a few-mm-thick CZT material provides adequate detection efficiency for many SPECT radiotracers. Because of these advantages, CZT detectors are becoming popular for several SPECT medical-imaging applications. Most recently, we designed a compact gamma camera using CZT detectors coupled to an application-specific-integrated-circuit (ASIC). This camera functions as a trans-rectal probe to image the prostate gland from a distance of only 1-5 cm, thus offering higher detection efficiency and higher spatial resolution. Hence, it potentially can detect prostate cancers at their early stages. The performance tests of this camera have been completed. The results show better than 6-mm resolution at a distance of 1 cm. Details of the test results are discussed in this paper.

36 MATERIALS SCIENCE↗

In silico identification of key genes and signaling pathways targeted by a panel of signature microRNAs in prostate cancer

Accumulating evidence have suggested that some microRNAs are aberrantly expressed in prostate cancer. In our previous work, we had identified a panel of four differentially expressed microRNAs in prostate cancer. In the present study, we have investigated common molecular targets of this panel of miRNAs (DEMs) and key hub genes that can serve as potential candidate biomarkers in the pathogenesis and progression of prostate cancer. A joint bioinformatics approach was employed to identify differentially expressed genes (DEGs) in prostate cancer. Gene enrichment analysis followed by the protein–protein interaction (PPI) network construction and selection of hub genes was further performed using String and Cytoscape, respectively. Gene ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway enrichment analysis of the identified hub genes was conducted using the Database for Annotation, Visualization and Integrated Discovery (DAVID) tool. In total, 496 genes were identified to be common targets of DEMs in prostate cancer and 13 key hub genes were identified from three modules of the PPI network of the DEGs. Further top five genes viz Rhoa, PI3KCA, CDC42, MAPK3, TP53 were used for Enrichment analysis which revealed their association with vital cellular and functional pathways in prostate cancer indicating their potential as candidate biomarkers in prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Syndecan-1 responsive microRNA-126 and 149 regulate cell proliferation in prostate cancer

Highlights: • Syndecan-1 is highly expressed in androgen independent prostate cancer cells, PC3. • Syndecan-1 regulates the expression of miR-126 and -149 in prostate cancer cells. • MiR-126 and 149 control cell growth via p21 induction and senescence mechanism. • MiR-126 and 149 promote cell proliferation by suppressing SOX2, NANOG, and Oct4. - Abstract: MicroRNAs (miRNAs) are short (19–24 nt), low molecular weight RNAs that play important roles in the regulation of target genes associated with cell proliferation, differentiation, and development, by binding to the 3′-untranslated region of the target mRNAs. In this study, we examined the expression of miRNA-126 (miR-126) and miR-149 in prostate cancer, and investigated the molecular mechanisms by which they affect syndecan-1 in prostate cancer. Functional analysis of miR-126 and miR-149 was conducted in the prostate cancer cell lines, PC3, Du145, and LNCaP. The expression levels of SOX2, NANOG, Oct4, miR-126 and miR-149 were evaluated by quantitative RT-PCR. After silencing syndecan-1, miR-126, and/or miR-149 in the PC3 cells, cell proliferation, senescence, and p21 induction were assessed using the MTS assay, senescence-associated β-galactosidase (SA-β-Gal) assay, and immunocytochemistry, respectively. Compared to the Du145 and LNCaP cells, PC3 cells exhibited higher expression of syndecan-1. When syndecan-1 was silenced, the PC3 cells showed reduced expression of miR-126 and miR-149 most effectively. Suppression of miR-126 and/or miR-149 significantly inhibited cell growth via p21 induction and subsequently, induced senescence. The mRNA expression levels of SOX2, NANOG, and Oct4 were significantly increased in response to the silencing of miR-126 and/or miR-149. Our results suggest that miR-126 and miR-149 are associated with the expression of syndecan-1 in prostate cancer cells. These miRNAs promote cell proliferation by suppressing SOX2, NANOG, and Oct4. The regulation of these factors by miR-126 and miR-149 is essential for syndecan-1-mediated development of androgen-refractory prostate cancer.

60 APPLIED LIFE SCIENCES↗

Intensified autophagy compromises the efficacy of radiotherapy against prostate cancer

Introduction: Radiotherapy is an equivalent alternative or complement to radical prostatectomy, with high therapeutic efficacy. High risk patients, however, experience high relapse rates, so that research on radio-sensitization is the most evident route to improve curability of this common disease. Materials and methods: In the current study we investigated the autophagic activity in a series of patients with localized prostate tumors treated with radical radiotherapy, using the LC3A and the LAMP2a proteins as markers of autophagosome and lysosome cellular content, respectively. The role of autophagy on prostate cancer cell line resistance to radiation was also examined. Results: Using confocal microscopy on tissue biopsies, we showed that prostate cancer cells have, overall, high levels of LC3A and low levels of LAMP2a compared to normal prostate glands. Tumors with a ‘highLC3A/lowLAMP2a’ phenotype, suggestive of intensified lysosomal consumption, had a significantly poorer biochemical relapse free survival. The PC3 radioresistant cell line sustained remarkably its autophagic flux ability after radiation, while the DU145 radiosensitive one experiences a prolonged blockage of the autophagic process. This was assessed with aggresome accumulation detection and LC3A/LAMP2a double immunofluorescence, as well as with sequestrosome/p62 protein detection. By silencing the LC3A or LAMP2a expression, both cell lines became more sensitive to escalated doses of radiation. Conclusions: High base line autophagy activity and cell ability to sustain functional autophagy define resistance of prostate cancer cells to radiotherapy. This can be reversed by blocking up-regulated components of the autophagy pathway, which may prove of importance in the field of clinical radiotherapy. - Highlights: • High LC3A and low LAMP2a levels is a frequent expression pattern of prostate carcinoma. • This pattern of intensified autophagic flux relates with high relapse rates after radiotherapy. • The PC3 radio-resistant cell line sustains remarkably its autophagic flux ability after radiation. • Irradiation of the DU145 radio-sensitive cell line blocks the autophagic flux. • Intense autophagy activity defines prostate cancer radio-resistance, in vivo and in vitro.

60 APPLIED LIFE SCIENCES↗

FFAR1-and FFAR4-dependent activation of Hippo pathway mediates DHA-induced apoptosis of androgen-independent prostate cancer cells

Highlights: • DHA induces cell growth inhibition and apoptosis of human prostate cancer cells. • DHA promotes YAP phosphorylation in androgen-independent prostate cancer cell lines. • DHA induces cell growth inhibition and apoptosis of PC3 cells via YAP. • DHA promotes YAP phosphorylation via FFAR1/4-dependent activation of the Hippo pathway. Evidence indicates that diets enriched in Docosahexaenoic acid (DHA), a 22:6 n-3 polyunsaturated fatty acid, reduces the risk of prostate cancer, but the biochemical mechanisms are unclear. The Hippo pathway has been well established as a tumor suppressor pathway and is involved in many diverse biologic processes including cell growth, cell death, and organ size control in organisms. Here we showed that DHA induces cell growth inhibition and apoptosis of human androgen-independent prostate cancer cells dependent on the Hippo pathway. DHA inactivates YAP by promoting phosphorylation in androgen-independent prostate cancer cell lines, accompanied by increased YAP cytoplasm translocation. We also observed that DHA-induced YAP phosphorylation was reversed by both the LATS1 and MST1 siRNAs. Further experiments showed that the mechanism of DHA-induced YAP phosphorylation associated with FFAR1 and FFAR4. Down-regulation of FFAR1 and FFAR4 resulted in reduced YAP phosphorylation and reversed DHA-induced YAP phosphorylation. In addition, DHA-induced YAP phosphorylation was abolished by dominant negative Gαs and PKA inhibitor H-89. Overall, these findings define a mechanism by which FFAR1-and FFAR4-dependent activation of Hippo pathway mediates DHA-induced apoptosis of androgen-independent prostate cancer cells, thus providing a promising therapeutic target for prostate cancer.

60 APPLIED LIFE SCIENCES↗

Prostate Brachytherapy in Men {>=}75 Years of Age

Purpose: To evaluate cause-specific survival (CSS), biochemical progression-free survival (bPFS), and overall survival (OS) in prostate cancer patients aged {>=}75 years undergoing brachytherapy with or without supplemental therapies. Methods and Materials: Between April 1995 and August 2004, 145 consecutive patients aged {>=}75 years underwent permanent prostate brachytherapy. Median follow-up was 5.8 years. Biochemical progression-free survival was defined by a prostate-specific antigen level {<=}0.40 ng/mL after nadir. Patients with metastatic prostate cancer or hormone-refractory disease without obvious metastases who died of any cause were classified as dead of prostate cancer. All other deaths were attributed to the immediate cause of death. Multiple clinical, treatment, and dosimetric parameters were evaluated for impact on survival. Results: Nine-year CSS, bPFS, and OS rates for the entire cohort were 99.3%, 97.1%, and 64.5%, respectively. None of the evaluated parameters predicted for CSS, whereas bPFS was most closely predicted by percentage positive biopsies. Overall survival and non-cancer deaths were best predicted by tobacco status. Thirty-seven patients have died, with 83.8% of the deaths due to cardiovascular disease (22 patients) or second malignancies (9 patients). To date, only 1 patient (0.7%) has died of metastatic prostate cancer. Conclusions: After brachytherapy, high rates of CSS and bPFS are noted in elderly prostate cancer patients. Overall, approximately 65% of patients are alive at 9 years, with survival most closely related to tobacco status. We believe our results support an aggressive locoregional approach in appropriately selected elderly patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting Prostate Cancer Mortality Among Men With Intermediate to High-Risk Disease and Multiple Unfavorable Risk Factors

Purpose: To determine whether the number of unfavorable risk factors could be used to predict the risk of prostate cancer-specific mortality (PCSM) among men with intermediate- to high-risk prostate cancer. Methods and Materials: We studied 1,063 men who underwent radical prostatectomy (n = 559), external beam radiotherapy (n = 288), or radiotherapy plus androgen suppression therapy (n = 116) for prostate cancer between 1965 and 2002. Fine and Gray's regression analysis was used to determine whether an increasing number of unfavorable risk factors (prostate-specific antigen level >10 ng/mL, Gleason score of {>=}7, clinical Stage T2b or greater, or pretreatment prostate-specific antigen velocity >2.0 ng/mL/y) was associated with the interval to PCSM and all-cause mortality. Results: Median follow-up was 5.6 years. Compared with those with one risk factor, the adjusted hazard ratio for PCSM was 2.3 (95% confidence interval 1.1-4.8; p = 0.03) for two risk factors, 5.4 (95% confidence interval 2.7-10.7; p < 0.0001) for three risk factors, and 13.6 (95% confidence interval 6.3-29.2; p < 0.0001) for all four risk factors. The 5-year cumulative incidence of PCSM was 2.4% for one factor, 2.4% for two factors, 7.0% for three factors, and 14.7% for all four factors. Prostate cancer deaths as a proportion of all deaths was 19% for one factor, 33% for two factors, 53% for three factors, and 80% for four factors. Conclusion: The number of unfavorable risk factors was significantly associated with PCSM. Prostate cancer was the major cause of death in men with at least three risk factors. Therefore, these men should be considered for clinical trials designed to assess whether survival is prolonged with the addition of novel agents to current standards of practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiotherapy for Localized Prostate Cancer: Interim Results of a Prospective Phase II Clinical Trial

Purpose: The radiobiology of prostate cancer favors a hypofractionated dose regimen. We report results of a prospective Phase II clinical trial of stereotactic body radiotherapy (SBRT) for localized prostate cancer. Methods and Materials: Forty-one low-risk prostate cancer patients with 6 months' minimum follow-up received 36.25 Gy in five fractions of 7.25 Gy with image-guided SBRT alone using the CyberKnife. The early (<3 months) and late (>6 months) urinary and rectal toxicities were assessed using validated quality of life questionnaires (International Prostate Symptom Score, Expanded Prostate Cancer Index Composite) and the Radiation Therapy Oncology Group (RTOG) toxicity criteria. Patterns of prostate-specific antigen (PSA) response are analyzed. Results: The median follow-up was 33 months. There were no RTOG Grade 4 acute or late rectal/urinary complications. There were 2 patients with RTOG Grade 3 late urinary toxicity and none with RTOG Grade 3 rectal complications. A reduced rate of severe rectal toxicities was observed with every-other-day vs. 5 consecutive days treatment regimen (0% vs. 38%, p = 0.0035). A benign PSA bounce (median, 0.4 ng/mL) was observed in 12 patients (29%) occurring at 18 months (median) after treatment. At last follow-up, no patient has had a PSA failure regardless of biochemical failure definition. Of 32 patients with 12 months minimum follow-up, 25 patients (78%) achieved a PSA nadir {<=}0.4 ng/mL. A PSA decline to progressively lower nadirs up to 3 years after treatment was observed. Conclusions: The early and late toxicity profile and PSA response for prostate SBRT are highly encouraging. Continued accrual and follow-up will be necessary to confirm durable biochemical control rates and low toxicity profiles.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Study of Pelvic Proton Radiotherapy for High-Risk Prostate Cancer

Purpose: To compare dose distributions in targeted tissues (prostate, seminal vesicles, pelvic regional nodes) and nontargeted tissues in the pelvis with intensity-modulated radiotherapy (IMRT) and forward-planned, double-scattered, three-dimensional proton radiotherapy (3D-PRT). Methods and Materials: IMRT, IMRT followed by a prostate 3D-PRT boost (IMRT/3D-PRT), and 3D-PRT plans were created for 5 high-risk prostate cancer patients (n = 15 plans). A 78-CGE/Gy dose was prescribed to the prostate and proximal seminal vesicles and a 46-CGE/Gy was prescribed to the pelvic nodes. Various dosimetric endpoints were compared. Results: Target coverage of the prostate and nodal planning target volumes was adequate for all three plans. Compared with the IMRT and IMRT/3D-PRT plans, the 3D-PRT plans reduced the mean dose to the rectum, rectal wall, bladder, bladder wall, small bowel, and pelvis. The relative benefit of 3D-PRT (vs IMRT) at reducing the rectum and rectal wall V5-V40 was 53% to 71% (p < 0.05). For the bladder and bladder wall, the relative benefit for V5 to V40 CGE/Gy was 40% to 63% (p < 0.05). The relative benefit for reducing the volume of small bowel irradiated from 5 to 30 CGE/Gy in the 3D-PRT ranged from 62% to 69% (p < 0.05). Use of 3D-PRT did not produce the typical low-dose 'bath' of radiation to the pelvis seen with IMRT. Femoral head doses were higher for the 3D-PRT. Conclusions: Use of 3D-PRT significantly reduced the dose to normal tissues in the pelvis while maintaining adequate target coverage compared with IMRT or IMRT/3D-PRT. When treating the prostate, seminal vesicles, and pelvic lymph nodes in prostate cancer, proton therapy may improve the therapeutic ratio beyond what is possible with IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effectiveness of Using Fewer Implanted Fiducial Markers for Prostate Target Alignment

Purpose: To evaluate the impact of the number and location of intraprostatic fiducial markers on the accuracy and reproducibility of daily prostate target alignment and to evaluate the migration of such markers. Methods and Materials: Three gold fiducial markers were implanted transrectally under ultrasound guidance near the apex, middle, and base of the prostate in 10 prostate cancer patients. The patients had pretreatment in-room computed tomography (CT) scans three times a week, for approximately 25 CT scans per patient during the 8-week treatment course. A total of 1280 alignments were performed using different alignment scenarios: whole-prostate soft tissue alignment (the gold standard), bone alignment, and seven permutations of alignments using one, two, or three fiducial markers. The results of bone alignment and fiducial alignment were compared with the results of whole-prostate alignment. Fiducial migration was also evaluated. Results: Single-fiducial-marker alignment was more accurate and reproducible than bone alignment. However, due to organ deformation, single fiducial markers did not always reliably represent the position of the entire prostate. The use of two-fiducial combinations was more accurate and reproducible than single-fiducial alignment, and use of all three fiducials was the best. Use of an apex fiducial together with a base fiducial rivaled the use of all three fiducials markers together. Fiducial migration was minimal. Conclusions: The number and the location of implanted fiducial markers affect the accuracy and reliability of daily prostate target alignment. The use of two or more fiducial markers is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Health-Related Quality of Life up to Six Years After {sup 125}I Brachytherapy for Early-Stage Prostate Cancer

Purpose: Health-related quality of life (HRQOL) after prostate brachytherapy has been extensively described in published reports but hardly any long-term data are available. The aim of the present study was to prospectively assess long-term HRQOL 6 years after {sup 125}I prostate brachytherapy. Methods and Materials: A total of 127 patients treated with {sup 125}I brachytherapy for early-stage prostate cancer between December 2000 and June 2003 completed a HRQOL questionnaire at five time-points: before treatment and 1 month, 6 months, 1 year, and 6 years after treatment. The questionnaire included the RAND-36 generic health survey, the cancer-specific European Organization for Research and Treatment of Cancer core questionnaire (EORTCQLQ-C30), and the tumor-specific EORTC prostate cancer module (EORTC-PR25). A change in a score of >=10 points was considered clinically relevant. Results: Overall, the HRQOL at 6 years after {sup 125}I prostate brachytherapy did not significantly differ from baseline. Although a statistically significant deterioration in HRQOL at 6 years was seen for urinary symptoms, bowel symptoms, pain, physical functioning, and sexual activity (p <.01), most changes were not clinically relevant. A statistically significant improvement at 6 years was seen for mental health, emotional functioning, and insomnia (p <.01). The only clinically relevant changes were seen for emotional functioning and sexual activity. Conclusion: This is the first study presenting prospective HRQOL data up to 6 years after {sup 125}I prostate brachytherapy. HRQOL scores returned to approximately baseline values at 1 year and remained stable up to 6 years after treatment. {sup 125}I prostate brachytherapy did not adversely affect patients' long-term HRQOL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation Between Pre- and Postimplant Dosimetry for Iodine-125 Seed Implants for Localized Prostate Cancer

Purpose: In order to evaluate implant quality for permanent prostate brachytherapy in patients with localized prostate cancer, American Brachytherapy Society and ESTRO guidelines recommend that postimplant dosimetry should be performed. To understand more about the relationship between pre- and postimplant dosimetry, a comparison was made of patients who received iodine-125 ({sup 125}I) brachytherapy between March 1995 and the end of 2004, using a preplan technique. Methods and Materials: CT postimplant dosimetry was available for 707 patients. Detailed dose volume analysis was performed using both preimplant ultrasound and postimplant CT data sets for a subgroup of 445 patients. The following parameters were compared: prostate volume covered by 100% of the prescription dose (Vp100), Vp150, and Vp200 and dose to 90% (D90) of the prostate. In addition, volume implanted (Vi) parameters were used to compare pre- and postimplant dosimetry. Vi parameters describe dose levels inside the patient, based on number of seeds, seed activity, and their spatial distribution relative to each other, without reference to the actual prostate volume or position. Results: The mean {+-} standard deviation values of preimplant (34.7 {+-} 8.9 cm{sup 3}) and postimplant (36.7 {+-} 9.4 cm{sup 3}) prostate volumes were similar. The mean ({+-}standard deviation) planned D90 was 183.4 ({+-}12.1) Gy while the D90 that was achieved was 145.5 ({+-}20.4) Gy. Over the study period, there was a steady increase of the average D90. Postimplant CT D90 and Vp100 values correlated significantly (R = 0.84; p < 0.001). The Vi and Vp parameters all showed a strong correlation. Conclusions: In this study, we showed that there is a strong correlation between transrectal ultrasound-based preimplant and CT-based postimplant dosimetry. The excellent correlation between prostate D90 and V100 values demonstrates they are both equally valid quality indices. Vi parameters are an additional measure that can be used to assess the quality of the implant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗