Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle accelerator facilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Measurements of displacement cross sections of metals for 120-GeV proton beam irradiation

The number of displacements per atom (dpa) is widely used as an indicator of irradiation damage of materials in proton accelerator facilities. Experiments have been carried out to validate the dpa of metallic materials for protons with energies below 3 GeV. However, measurements of the displacement cross-sections for high-energy protons above 3 GeV have not been carried out and the calculations have not been validated. To validate the displacement cross section of metals in high-energy region, electrical resistivity changes in wires of aluminum, copper and tungsten at 8 K were measured using protons with energies of 120-GeV. The results show that the Norgett-Robinson-Torrens dpa model of the Particle and Heavy Ion Transport Calculation Code overestimates the experimental data. On the other hand, the calculated results using the athermal recombination corrected dpa model were in agreement with the measured displacement cross sections. In the proton energy region above 1 GeV, the displacement cross section is almost constant, which is due to the fact that the damage energy of the material under 1 GeV proton irradiation is almost the same as under 120 GeV proton irradiation. Damage recovery of defects accumulated in the sample was also measured using isochronal annealing: At 80 K, approximately 60 % and 80 % of the damage remains for copper and tungsten, respectively. These results are the same as those obtained from other experiments on proton and neutron irradiation.

43 PARTICLE ACCELERATORS↗

FFA@CEBAF beam transport error and tolerance simulation studies

The Continuous Electron Beam Accelerator Facility (CEBAF) is a 12 GeV recirculating electron accelerator at the Thomas Jefferson National Accelerator Facility (JLAB). Major upgrades to the accelerator are being investigated which include a new 650 MeV injection beamline and state-of-the-art fixed-field alternating (FFA) gradient recirculation arcs. The upgrade will extend the energy of the electron beam to over 20 GeV. In this paper, we provide an error and tolerance simulation study of the amended beam optics transport of the existing accelerator tuned for 22 GeV operation. The study is conducted with the particle tracking codes elegant and Bmad in two parts. In the first part, we treat each section of the accelerator (electromagnetic arcs and linacs) modularly with ideal conditions at the beginning. The second part is a pseudo start-to-end (S2E) simulation with accumulated errors propagating from one beamline to the next.

Accelerator Physics↗

Continual Learning for Particle Accelerators

Particle accelerators operate under dynamically changing conditions, which often lead to data distribution drifts. These drifts pose significant challenges for Machine Learning (ML) models, which typically fail to maintain performance when faced with such non-stationary data. In particle accelerators, the primary sources of these data drifts include changes in accelerator settings and non-measured parameters such as machine degradation and environmental factors. Previous research has proposed conditional models to handle multiple beam configurations effectively; however, it is challenging to train the ML models on all possible configuration settings. Additionally, conditional models alone can not address performance degradation caused by drifts due to non-measured factors. These limitations contribute to a significant gap between ML development and its deployment in real-world operational settings. To bridge this gap, in this paper, we identify some of the key areas within particle accelerators where continual learning can help mitigate drift-induced performance degradation. In addition, we present a practical use case where a conditional Auto-Encoder model coupled with memory-based continual learning has been employed to demonstrate stable performance even when underlying data drifts.

Schram, Malachi [Thomas Jefferson National Acceler↗

Continual Learning for Particle Accelerators

Particle accelerators operate under dynamically changing conditions, which often lead to data distribution drifts. These drifts pose significant challenges for Machine Learning (ML) models, which typically fail to maintain performance when faced with such non-stationary data. In particle accelerators, the primary sources of these data drifts include changes in accelerator settings and non-measured parameters such as machine degradation and environmental factors. Previous research has proposed conditional models to handle multiple beam configurations effectively; however, it is challenging to train the ML models on all possible configuration settings. Additionally, conditional models alone can not address performance degradation caused by drifts due to non-measured factors. These limitations contribute to a significant gap between ML development and its deployment in real-world operational settings. To bridge this gap, in this paper, we identify some of the key areas within particle accelerators where continual learning can help mitigate drift-induced performance degradation. In addition, we present a practical use case where a conditional Auto-Encoder model coupled with memory-based continual learning has been employed to demonstrate stable performance even when underlying data drifts

Rajput, Kishansingh [Thomas Jefferson National Acc↗

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Source size of x rays from self-modulated laser wakefield accelerators

A comparative study of x-ray sources generated with different mechanisms from self-modulated laser wakefield acceleration (SM-LWFA) electrons was performed to compare the source size or spatial resolution for use in high energy density science applications. We examine the source size of betatron, inverse Compton scattering, and bremsstrahlung radiation with a Fresnel diffraction based formalism and a modified x-ray ray tracing model. We observe the dependence of source size on the radiation generation process, laser parameters, and compare to what is possible in other regimes of LWFA, as well as current methods. This information is significant as we begin to explore the use of light sources driven by SM-LWFA for use as a diagnostic at large-scale laser facilities where blowout regime LWFA is not possible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Corrosion-Resistant Non-Carbon Electrocatalyst Supports for PEFCS

Insufficient durability of commercial catalysts is a persistent issue for PEFC applications.1 Herein, Pt on Nb-doped-TiO 2 is reported as a highly durable electrocatalyst on which the direct 4-electron reduction of oxygen to water is more facile compared to Pt/C. All performance metrics are reported comparing Pt/Nb-TiO2 with a 15% Pt loading, against a commercial Pt/C catalyst (46.5% Pt loading, Tanaka, K. K.). Nb-doped-TiO 2 with high surface area and high electronic conductivity was synthesized using the supercritical fluid method. Initially, the durability of the catalyst was characterized using accelerated stability tests (ASTs) involving 10,000 high potential cycles (DOE/FCCJ protocol) and the Pt/Nb-TiO 2 was found to retain 78% of its initial electrochemically active surface area (ECSA) compared to the 57.6 % retained by Pt/C. These observations were in excellent agreement with previous reports that the Pt particle size of Pt/C grew from 2nm to 8nm during the AST protocol along with severe corrosion and amorphization of the carbon surface.2, 3 TEM and XPS studies of the Pt-Nb-doped-TiO 2 catalyst showed that the Pt particle size grew from 3nm to 6nm and the Nb(IV) and Ti(III) in the support were oxidized to Nb(V) and Ti(IV) after the durability test. Thus, the improvement in Pt/Nb-TiO 2 ECSA retention was attributed to the lower extent of particle growth and lack of oxidative support loss upon oxidation as compared to Pt/C. The oxygen reduction reaction (ORR) performance was characterized by linear polarization using a rotating disk electrode (RDE). The electrochemical surface areas of Pt/Nb-TiO 2 and Pt/C were found to be 48m2·g -1 and 83m2·g -1 respectively, and the mass activity for the ORR at 0.9V vs. RHE were found to be 150 mA·mg-1Pt and 124 mA·mg-1Pt respectively. The improved mass activity on Pt/Nb-TiO 2 was attributed to strong metal support interaction (SMSI) between the Nb-TiO 2 support and the Pt catalyst based on the 625 meV decrease in the binding energy of the Pt4f x-ray photo-electron spectroscopy (XPS) peaks of Pt/Nb-TiO 2 compared to Pt/C. To quantify the impact of the SMSI, a kinetic model was applied to calculate the elementary reaction rate constants for the various steps of the ORR on both catalysts. The reaction rate constant (k1) for the direct 4-electron transfer pathway to produce H 2 O was significantly larger in Pt/Nb-TiO 2 as compared to Pt/C. Thus, the reduction in the electron binding energy as observed in the XPS was found to aid the facile filling of the higher energy 2p orbitals of O 2 thereby leading to improved 4-electron transfer kinetics and improved overall activity.

08 HYDROGEN↗

First operation of superconducting quantum bits as particle detectors

Transmon qubits are among the leading technologies for the development of future quantum computers. However these superconducting devices are sensitive to ionizing radiation, which reduces their coherence time and leads to correlated errors. This study represents the first quantitative estimation of cosmic rays and ambient radiation impact on transmon qubits. In the shielded underground facility at the Laboratori Nazionali del Gran Sasso (LNGS), errors induced by the interaction of a radioactive source were reconstructed with an efficiency of about 10%. In contrast, in the unshielded above-ground facility at the Fermi National Accelerator Laboratory (FNAL), cosmic and ambient radiation impacts were detected with an efficiency ranging from 10% to 20% by modifying the acquisition protocol. Lastly, the simultaneous readout of three transmons in coincidence was demonstrated, achieving an event reconstruction efficiency of 90% when the devices were illuminated with an LED.

Bonomo, Camilla [Rome U.; INFN, Rome]↗

Development of a versatile plate spectrometer for electron beam characterization

A new instrument for electron beam characterization has been developed, based on measuring the range of beam electrons in different thicknesses of aluminum, to determine both the current and energy of an electron beam traveling in open air. This instrument is referred to as a ‘plate spectrometer’ as the thickness of the spectrometer is adjusted by adding or removing aluminum plates. This spectrometer was assembled and then characterized at the Idaho Accelerator Center (IAC) with three different beam energies and with one beam energy at the University of Maryland Radiation Facilities. The plate spectrometer was able to match the median energies and provide a reasonable constraint to the beam distributions seen in the IAC magnetic spectrometer. Finally, in a separate experiment, the plate spectrometer was also seen to agree with a dosimetry characterization of the beam at the University of Maryland Radiation Facilities and improved upon the uncertainties of this measurement.

43 PARTICLE ACCELERATORS↗

Beam Test Characterization of an Irradiated Pixel-Strip Module for HL_LHC CMS Tracker Upgrade

A new tracker, for the CMS detector at The Large Hadron Collider, will be built to address the demands of the High Luminosity upgrade which aims to achieve peak instantaneous luminosities from 5 up to 7.5 10^34 cm^-2 s^-1 and an integrated luminosity of 3000 4000 fb^-1 at a center of mass energy of 14 TeV. To meet the resulting challenges, the CMS experiment is changing its outer tracker silicon modules to include tracking capabilities at the Level-1 trigger. As part of this upgrade effort, a prototype module, combining both pixel and strip sensors (PS-module), was irradiated and subsequently tested at the Fermilab Test Beam and Irradiation facilities. These tests evaluated the module's ability to maintain precise tracking, effective particle momentum discrimination, and consistent performance when exposed to the radiation levels expected in the High Luminosity LHC environment. Results from these studies are presented with a focus on comparing the module's performance before and after irradiation.

43 PARTICLE ACCELERATORS↗

Quadrupole forces between quark and gluon subsystems inside higher-spin particles

We generalize the mechanical interpretation of the forces between quark and gluon subsystems, previously studied for the nucleon, to arbitrary higher-spin particles. For spin-0 and spin-1/2 particles, this force is characterized by the nonconserved $\overline{𝑐}$⁡(𝑡) form factor. However, such an interpretation has not yet been established for higher-spin particles due to the intricate structure of the nonconserved energy-momentum tensor (EMT) form factors. By performing a multipole expansion, we identify the physically meaningful combinations of the nonconserved covariant EMT form factors and provide them with a clear mechanical interpretation.

Baryons↗

The ALTEA/ALTEINO projects: studying functional effects of microgravity and cosmic radiation

The ALTEA project investigates the risks of functional brain damage induced by particle radiation in space. A modular facility (the ALTEA facility) is being implemented and will be operated in the International Space Station (ISS) to record electrophysiological and behavioral descriptors of brain function and to monitor their time dynamics and correlation with particles and space environment. The focus of the program will be on abnormal visual perceptions (often reported as "light flashes" by astronauts) and the impact on retinal and brain visual structures of particle in microgravity conditions. The facility will be made available to the international scientific community for human neurophysiological, electrophysiological and psychophysics experiments, studies on particle fluxes, and dosimetry. A precursor of ALTEA (the 'Alteino' project) helps set the experimental baseline for the ALTEA experiments, while providing novel information on the radiation environment onboard the ISS and on the brain electrophysiology of the astronauts during orbital flights. Alteino was flown to the ISS on the Soyuz TM34 as part of mission Marco Polo. Controlled ground experiments using mice and accelerator beams complete the experimental strategy of ALTEA. We present here the status of progress of the ALTEA project and preliminary results of the Alteino study on brain dynamics, particle fluxes and abnormal visual perceptions. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

manned↗

Robotic Assembly of SRF Cavity Pair

Superconducting Radio Frequency (SRF) cavities for particle accelerators require tight tolerances, ultrahigh vacuum, and strict cleanliness during assembly. As in the semiconductor industry, defects such as particles and residues are deleterious to performance, possibly rendering a cavity unfit for use. This problem is addressed primarily through cleanroom assembly during sensitive steps and rigorous chemical processing to prevent and remove such defects. Human workers are often the largest source of contamination, even with proper gowning and practices. The semiconductor industry has long integrated robots in cleanroom operation, but this has not occurred for SRF cavity production; SRF cavities, unlike wafers, are complex shapes, require more hands-on mechanical assembly, and are low-volume production items. At Jefferson Laboratory, a co-operative robot (cobot) has been setup to overcome these problems. Cobots are safe for use alongside human workers and can integrate new tools such as a 3D camera part detection and gripper for item manipulation. Therefore, cobots represent a promising avenue for reducing particulate generated during a variety of assembly tasks. A mockup of a cavity pair and coupler was setup and the cobot programmed to automatically pick up the coupler and place on the mating cavity flange. Particle counting methods were setup to measure human vs cobot assembly particulate generation inside a cavity mockup. Other potential uses will be discussed for further improving SRF cavity assembly steps, where a cobot can replace or assist a human operator, and what potential gains are expected.

Duzik, Adam [Thomas Jefferson National Accelerator↗

Corona and solar wind

The Pinhole/Occulter Facility is a powerful tool for studying the physics of the extended corona and origins of the solar wind. Spectroscopic data acquired by the P/OF coronal instruments can greatly expand empirical information about temperatures, densities, flow velocities, magnetic fields, and chemical abundances in the corona out to r or approx. 10 solar radii. Such information is needed to provide tight empirical constraints on critical physical processes involved in the transport and dissipation of energy and momentum, the heating and acceleration of plasma, and the acceleration of energetic particles. Because of its high sensitivity, high spatial and temporal resolutions, and powerful capabilities for plasma diagnostics, P/OF can significantly increase our empirical knowledge about coronal streamers and transients and thereby advance the understanding of the physics of these phenomena. P/OF observations can be used to establish the role in solar wind generation, if any, of small-scale dynamical phenomena, such as spicules, macrospicules and coronal bullets, and the role of the fine-scale structures, such as polar plumes. Finally, simultaneous measurements by the P/OF coronal and hard X-ray instruments can provide critical empirical information concerning nonthermal energy releases and acceleration of energetic particles in the corona.

Withbroe, G. L.↗

Lead tungstate calorimeters at Jefferson Lab and perspectives for the Electron–Ion Collider

Electromagnetic calorimeters based on PbWO4 scintillating crystals have a widespread applica- tion in experiments at different accelerator facilities such as CERN, FNAL, GSI, and Jefferson Lab. The unique properties of PbWO4 crystals, including a small radiation length and Molire radius, make them ideal for building high-granularity, radiation-hard detectors. This enables excellent spa- tial separation and energy resolution of reconstructed electromagnetic showers, making PbWO4 crystals the material of choice for numerous experiments. Lead tungstate calorimeters have been successfully used in several experiments at Jefferson Lab. Two large-scale detectors have been re- cently fabricated for future experiments : the Neutral Particle Spectrometer and the lead tungstate calorimeter of the GlueX detector. The future application of PbWO4 crystals in the ElectronIon Collider further highlights their ongoing importance in advancing experimental capabilities. In planning new experiments, the development of calorimeter instrumentation technologies becomes paramount. The integration of modern photodetectors, such as Silicon photomultipliers that are capable of operating in strong magnetic fields, and the implementation of streaming readout data acquisition systems, sophisticated shower reconstruction algorithms, and real-time data analysis are some examples of the continuously growing requirements of experimental setups. I will give an overview of the lead tungstate scintillating calorimeters and discuss some recent advancement in the calorimeter instrumentation.

Somov, Alexander↗

Radiation Effects: Core Project

The risks to personnel in space from the naturally occurring radiations are generally considered to be one of the most serious limitations to human space missions, as noted in two recent reports of the National Research Council/National Academy of Sciences. The Core Project of the Radiation Effects Team for the National Space Biomedical Research Institute is the consequences of radiations in space in order to develop countermeasure, both physical and pharmaceutical, to reduce the risks of cancer and other diseases associated with such exposures. During interplanetary missions, personnel in space will be exposed to galactic cosmic rays, including high-energy protons and energetic ions with atomic masses of iron or higher. In addition, solar events will produce radiation fields of high intensity for short but irregular durations. The level of intensity of these radiations is considerably higher than that on Earth's surface, and the biological risks to astronauts is consequently increased, including increased risks of carcinogenesis and other diseases. This group is examining the risk of cancers resulting from low-dose, low-dose rate exposures of model systems to photons, protons, and iron by using ground-based accelerators which are capable of producing beams of protons, iron, and other heavy ions at energies comparable to those encountered in space. They have begun the first series of experiments using a 1-GeV iron beam at the Brookhaven National Laboratory and 250-MeV protons at Loma Linda University Medical Center's proton synchrotron facility. As part of these studies, this group will be investigating the potential for the pharmaceutical, Tamoxifen, to reduce the risk of breast cancer in astronauts exposed to the level of doses and particle types expected in space. Theoretical studies are being carried out in a collaboration between scientists at NASA's Johnson Space Center and Johns Hopkins University in parallel with the experimental program have provided methods and predictions which are being used to assess the levels of risks to be encountered and to evaluate appropriate strategies for countermeasures. Although the work in this project is primarily directed toward problems associated with space travel, the problem of protracted exposures to low-levels of radiation is one of national interest in our energy and defense programs, and the results may suggest new paradigms for addressing such risks.

Dicello, John F.↗

Flavor Dependence of Charged Pion Fragmentation Functions

We have measured the flavor dependence of multiplicities for π + and π - production in semi-inclusive deep-inelastic scattering (SIDIS) on proton and deuteron to explore a possible charge symmetry violation in fragmentation functions. The experiment used an electron beam with energies of 10.2 and 10.6 GeV at Jefferson Lab and the Hall-C spectrometers. The electron kinematics spanned the range 0.3 < x < 0.6, 2 < Q 2 < 5.5 GeV2, and 2.2 < W < 3.2 GeV. The pion fractional momentum range was 0.3 < z < 0.7, and the transverse momentum range was 0 < p T < 0.25 GeV/c. Assuming factorization and allowing for isospin breaking, the results can be described by two “favored” and two “unfavored” effective low p T fragmentation functions that are flavor-dependent. We find each pair converges to a common flavor-independent fragmentation function at the highest W, where factorization is most applicable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Factorization for jet production in heavy-ion collisions

We develop an Effective Field Theory approach for jet observables in heavy-ion collisions, where the jet is treated as an open quantum system interacting with a hot and dense QCD medium. Within this framework, we derive a novel factorization formula for inclusive jet production, expressed as a series expansion with an increasing number of radiating subjet functions that encode forward scattering with the Quark-Gluon Plasma, convolved with perturbative matching coefficients. This work provides a systematic framework for computing jet observables at higher order and understanding their non-perturbative aspects, paving the way for future applications in heavy-ion phenomenology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗