Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particulate Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Fine particulate matter source apportionment for the chemical speciation trends network site at Birmingham, Alabama, using positive matrix factorization

The Positive Matrix Factorization (PMF) receptor model version 1.1 was used with data from the fine particulate matter (PM2.5) Chemical Speciation Trends Network (STN) to estimate source contributions to ambient PM2.5 in a highly industrialized urban setting in the southeastern United States. Model results consistently resolved 10 factors that are interpreted as two secondary, five industrial, one motor vehicle, one road dust, and one biomass burning sources. It was found that most PMF factors did not cleanly represent single source types and instead are 'contaminated' by other sources. Secondary particulate matter formed by atmospheric processes, such as sulfate and secondary OC, contribute the majority of ambient PM2.5 and exhibit strong seasonality 37 {+-} 10% winter vs. 55 {+-} 16% summer average. Motor vehicle emissions constitute the biggest primary PM2.5 mass contribution. In summary, this study demonstrates the utility of the EC tracer method to effectively blank-correct the OC concentrations in the STN dataset. In addition, examination of the effect of input uncertainty estimates on model results indicates that the estimated uncertainties currently being provided with the STN data may be somewhat lower than the levels needed for optimum modeling results. An appendix , available to members on the website www.awma lists stationary sources of PM2.5 within 10 km of the NHBM site and PM2.5 emissions greater than 1 ton per year. 71 refs., 7 figs., 9 tabs.

01 COAL, LIGNITE, AND PEAT↗

Contaminant Entrainment in a Liquid Fuel Fire with Multi-Component Evaporation Droplet Model

A number of fire scenarios can result in the release of hazardous chemical or radiological contaminants as sub-micron solid particulates, posing a significant danger of inhalation. These particulates may be entrained in the air around the fire through a variety of mechanisms including liquid droplet formation above the boiling surface of the contaminated fuel. The formation of both film drops from the rupture of a liquid film as a boiling bubble bursts and jet drops from the collapse of the cavity of a ruptured bubble may be involved. A 2015 study by Brown and Louie focused on such a fire scenario to investigate the physics of contaminant release. This paper extends that study by supplementing the existing physics models with a multicomponent evaporation mechanism, where liquid droplets formed near the boiling fuel surface experience evaporation of their various components at different rates based on distinct material properties (density, specific heat, heat of vaporization, etc.). As in the Brown and Louie study, the Sierra low-Mach module Fuego is used as the Lagrangian-Eulerian code for simulation of this scenario. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A fundamentally new approach to air-cooled heat exchangers.

We describe breakthrough results obtained in a feasibility study of a fundamentally new architecture for air-cooled heat exchangers. A longstanding but largely unrealized opportunity in energy efficiency concerns the performance of air-cooled heat exchangers used in air conditioners, heat pumps, and refrigeration equipment. In the case of residential air conditioners, for example, the typical performance of the air cooled heat exchangers used for condensers and evaporators is at best marginal from the standpoint the of achieving maximum the possible coefficient of performance (COP). If by some means it were possible to reduce the thermal resistance of these heat exchangers to a negligible level, a typical energy savings of order 30% could be immediately realized. It has long been known that a several-fold increase in heat exchanger size, in conjunction with the use of much higher volumetric flow rates, provides a straight-forward path to this goal but is not practical from the standpoint of real world applications. The tension in the market place between the need for energy efficiency and logistical considerations such as equipment size, cost and operating noise has resulted in a compromise that is far from ideal. This is the reason that a typical residential air conditioner exhibits significant sensitivity to reductions in fan speed and/or fouling of the heat exchanger surface. The prevailing wisdom is that little can be done to improve this situation; the 'fan-plus-finned-heat-sink' heat exchanger architecture used throughout the energy sector represents an extremely mature technology for which there is little opportunity for further optimization. But the fact remains that conventional fan-plus-finned-heat-sink technology simply doesn't work that well. Their primary physical limitation to performance (i.e. low thermal resistance) is the boundary layer of motionless air that adheres to and envelops all surfaces of the heat exchanger. Within this boundary layer region, diffusive transport is the dominant mechanism for heat transfer. The resulting thermal bottleneck largely determines the thermal resistance of the heat exchanger. No one has yet devised a practical solution to the boundary layer problem. Another longstanding problem is inevitable fouling of the heat exchanger surface over time by particulate matter and other airborne contaminants. This problem is especially important in residential air conditioner systems where often little or no preventative maintenance is practiced. The heat sink fouling problem also remains unsolved. The third major problem (alluded to earlier) concerns inadequate airflow to heat exchanger resulting from restrictions on fan noise. The air-cooled heat exchanger described here solves all of the above three problems simultaneously. The 'Air Bearing Heat Exchanger' provides a several-fold reduction in boundary layer thickness, intrinsic immunity to heat sink fouling, and drastic reductions in noise. It is also very practical from the standpoint of cost, complexity, ruggedness, etc. Successful development of this technology is also expected to have far reaching impact in the IT sector from the standpointpoint of solving the 'Thermal Brick Wall' problem (which currently limits CPU clocks speeds to {approx}3 GHz), and increasing concern about the the electrical power consumption of our nation's information technology infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Waste Management 2016 300-296 Soil Remediation Project. Developing Innovative Solutions to Overcome Design Challenges - 16229

The 324 Building is a non-reactor, Hazard Category 2, Nuclear Facility located in the 300 Area of the U.S. Department of Energy (DOE) Hanford Site, located near Richland, Washington. The building is undergoing deactivation, decommissioning, decontamination, and demolition by Washington Closure Hanford (WCH) under the River Corridor Closure Contract. During the Cold War Era, the facility was used for chemical and radionuclide processing associated with nuclear weapons production. Historical records indicate that in October 1986, approximately 516 L of a concentrated liquid waste stream containing cesium-137 and strontium-90 was spilled onto the floor of B-Cell. B-Cell is located in the Radiochemical Engineering Complex (REC) of the 324 Building. It is estimated that this spill contained approximately 1.3 million curies of radioactivity. Some fraction of the spill was recovered; however, an unknown quantity was released into the soil beneath the 324 Building through an undetected breach in the B-Cell floor sump. Unknown quantities of water were used after the spill to wash items contained in B-Cell. When B-Cell was taken out of service, wastes being removed from B-Cell were placed in Grout Containers (GCs) and stabilized using a particulate grout. In the course of grouting activities, grout was spilled on the floor of B-Cell, eventually filling the sump. The primary scope of this project is to design, test, and implement a process capable of removing and isolating contaminated soil below B-Cell. This remediation effort has been divided into two removal zones identified as the primary and secondary removal zones. Based on current assumptions and estimates, the primary phase of this cleanup effort will remove roughly 156.45 m{sup 3} of highly contaminated materials. B-Cell debris, particulate grout, and the floor slab and liner comprise about 21.24 m{sup 3} of the total. The remaining 135.21 m3 will be contaminated soil. All of this material must be disposed of within the existing 324 Facility or packaged for disposal at the Hanford site. The objective of this project is to remove the B-Cell floor and highly contaminated underlying soils from beneath B-Cell using remote equipment to reduce the radiation levels and allow open-air excavation for the remaining contaminated soil. The challenges and subsequent technological solutions encountered from the Conceptual Design phase to the 100% Design Issued For Fabrication/Issued For Construction (IFF/IFC) consisted in part of the following: Design an efficient remote cleanup strategy for highly contaminated Low Level Waste (LLW) given the unknowns. Maintain contamination control down to 18 feet below B-Cell in a highly radioactive environment (12,870 R/Hr Cs-137 and Sr-90). Perform facility upgrades to enable remediation process implementation while maintaining integrity of pre-existing facility structure and license. Designing first-of-a-kind remote equipment for use in high radiation areas. Developing first-of-a-kind operations sequences for remote equipment while minimizing usage of original facility equipment (i.e. cranes, manipulators, etc.). Conducting time-motion studies of operations sequences to maximize efficiency while keeping dose As Low As Reasonably Achievable (ALARA) in a high dose environment. Construction of a full scale mockup to conduct performance testing in a clean environment and train the work force to operate the equipment. Overcoming scope, budget and schedule constraints associated with a fast-track DOE project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dirty bomb source term characterization and downwind dispersion: Review of experimental evidence

Dirty bombs are considered one of the easiest forms of radiological terrorism, a form of terrorism based on the deliberate use of radiological material to cause adverse effects in a target population. One U.S. Government official has even described a dirty bomb attack as “all but inevitable”. While people in the vicinity of the blast may experience acute radiation effects, people downwind may unknowingly be contaminated by the radioactive airborne particulate and face increased long-term cancer risk. The likelihood of increased cancer risk depends on the radionuclide used and its specific activity, its aerosolization potential, the particle sizes generated in the blast, and where a person is with respect to the detonation. Different studies have reported that plausible radionuclides for dirty bomb include 60 Co, 90 Sr, 137 Cs, 192 Ir, 241 Am based on their availability in commercial sources as well as safeguards, the amount needed for adverse health effects, previous mishandling of radionuclides and malicious uses. In order to have increased long-term cancer risk, the radionuclide would have to deposit inside the body by entering the respiratory tract and then possibly migrate to other organs or bones (ground shine is not considered in this paper because areas affected by the event will likely become inaccessible). This implies that the particles will have to be smaller than 10 μm to be inhaled. Experiments involving the detonation of dirty bombs have shown that particles or droplets smaller than 10 μm are generated, independently from the initial radionuclide or its state (e.g., powder, solution). Atmospheric tests have shown that in unobstructed terrain, the radionuclide laden cloud can travel kilometers downwind even for relatively small amounts of explosives. Furthermore, buildings in the path of the cloud can change the dose rate. For instance, in one experiment with a single building, the dose rate was 1–2 orders of magnitude lower behind the obstacle compared to its front face. For people walking around, the amount of particulate deposited on them and inhaled will depend on their path relative to the cloud, resulting in the counterintuitive result that the closer people may actually not be the ones more at risk because they could simply miss the bulk of the cloud in their wandering. In summary, the long-term cancer risk for people caught in a dirty bomb cloud away from the detonation requires considering where and when the people are, which radionuclide was used, and the layout of the obstacles (e.g., buildings, vegetation) in the path of the cloud.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

EnviroNET

EnviroNET is a service/facility that provides users with on-line, dial-up technical information concerning environmental conditions likely to be encountered by instruments and experimental arrangements carried aboard spacecraft. EnviroNET incorporates at present a combination of expository text and numerical tables amounting to about two million characters (bytes), plus FORTRAN programs that model the space environment. The topics covered are presented in viewgraph form and include the following: advantages of EnviroNET; thermal and humidity; vibration and acoustics; electromagnetic interference; loads and low frequency dynamics; microbial and toxic contaminants; molecular contamination; natural environment; orbiter motion; particulate environment; surface interactions; spacecraft anomalies; and interactive graphics facility.

Vansant, Tim↗

Air Sampling Filter

General Metal Works' Accu-Vol is a high-volume air sampling system used by many government agencies to monitor air quality for pollution control purposes. Procedure prevents possible test-invalidating contamination from materials other than particulate pollutants, caused by manual handling or penetration of windblown matter during transit, a cassette was developed in which the filter is sealed within a metal frame and protected in transit by a snap-on aluminum cover, thus handled only under clean conditions in the laboratory.

Source record↗

Resonant-frequency discharge in a multi-cell radio frequency cavity

We are reporting experimental results on a microwave discharge operating at resonant frequency in a multi-cell radio frequency (RF) accelerator cavity. Although the discharge operated at room temperature, the setup was constructed so that it could be used for plasma generation and processing in fully assembled active superconducting radio-frequency cryo-module. This discharge offers a mechanism for removal of a variety of contaminants, organic or oxide layers, and residual particulates from the interior surface of RF cavities through the interaction of plasma-generated radicals with the cavity walls. We describe resonant RF breakdown conditions and address the issues related to resonant detuning due to sustained multi-cell cavity plasma. We have determined breakdown conditions in the cavity, which was acting as a plasma vessel with distorted cylindrical geometry. We discuss the spectroscopic data taken during plasma removal of contaminants and use them to evaluate plasma parameters, characterize the process, and estimate the volatile contaminant product removal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of CO2 Snow Jet Cleaning in Conjunction with Laboratory Based Total Reflection X-Ray Fluorescence

The Genesis mission was the first mission returning solar material to Earth since the Apollo program [1,2]. Unfortunately the return of the space craft on September 8, 2004 resulted in a crash landing, which shattered the samples into small fragments and exposed them to desert soil and other debris. Thus only small fragments of the original collectors are available, each having different degrees of surface contamination. Thorough surface cleaning is required to allow for subsequent analysis of solar wind material embedded within. An initial cleaning procedure was developed in coordination with Johnson Space Center which focused on removing larger sized particulates and a thin film organic contamination acquired during collection in space [3]. However, many of the samples have additional residues and more rigorous and/or innovative cleaning steps might be necessary. These cleaning steps must affect only the surface to avoid leaching and re-distribution of solar wind material from the bulk of the collectors. To aid in development and identification of the most appropriate cleaning procedures each sample has to be thoroughly inspected before and after each cleaning step. Laboratory based total reflection X-ray fluorescence (TXRF) spectrometry lends itself to this task as it is a non-destructive and surface sensitive analytical method permitting analysis of elements from aluminum onward present at and near the surface of a flat substrate [4]. The suitability of TXRF has been demonstrated for several Genesis solar wind samples before and after various cleaning methods including acid treatment, gas cluster ion beam, and CO2 snow jet [5 - 7]. The latter one is non-invasive and did show some promise on one sample [5]. To investigate the feasibility of CO2 snow jet cleaning further, several flown Genesis samples were selected to be characterized before and after CO2 snow application with sample 61052 being discussed below.

Schmeling, M.↗

Spacecraft contamination environment; Proceedings of the Meeting, Arlington, VA, May 4-6, 1982

Aspects of IECM debriefing are considered, taking into account preliminary results of the induced environment contamination monitor measurements of STS-2, the humidity monitor and dew point hygrometer, the induced environment contamination monitor cascade impactor, the optical effects module and passive sample array, temperature-controlled quartz crystal microbalance measurements on STS-2, camera/photometer results, the mass spectrometer, and a summary regarding the induced environment contamination monitor/space transport system. Other subjects explored are related to contamination management and control, contamination/optical degradation, and contamination assessments and measurements. Attention is given to approaches for controlling contamination before launch, the coronagraph as the ultimate device to monitor orbiting particulates in the Space Transport System environment, and the contamination sensitivity of typical mirror coatings.

Maag, C. R.↗

The TRANSCEND University Consortium: Theme 2 - Site Decommissioning, Deconstruction and Remediation - 20329

This paper will discuss the aims, objectives and progress to-date under Theme 2 of the TRANSCEND consortium project: Site decommissioning, deconstruction and remediation. Decommissioning nuclear sites involves waste retrieval, decontamination, deconstruction and, where necessary, containment and/or remediation of the remaining structure and surrounding land. Critical to management of these processes is limiting radiation exposure for the workforce, restricting the spread of radionuclides in groundwater, surface water and airborne particulates, and minimising the volume of contaminated waste for disposal. The aim of Theme 2 research is to develop new technologies for monitoring, remediation and containment that serve to minimise the volume of radioactively contaminated waste for disposal, for application prior to, during and after retrieval, deconstruction and decontamination operations. Prior research, conducted under the previous DISTINCTIVE project, demonstrated that colloidal silica grout can penetrate low permeability materials (including cement) for hydraulic barrier formation, and improved sorption capacity. The silica grout can be injected at surface using extremely small (potentially gravity-driven) fluid pressures, without the need for borehole drilling. Current work is investigating the erodibility of silica-grouted soils for inhibition of airborne and water-borne particulates as well as enhancing the grout's sorption capacity by addition of other materials to provide a chemical, as well as hydraulic, barrier to subsurface migration. EK remediation uses low voltage DC current to control migration of contaminants in porous media as well as to remove or degrade them. Researchers in the consortium have already demonstrated that low-energy ex-situ EK techniques can be used to provide remediation and volume minimisation for AWE legacy wastes in the UK. Under the current project researchers are building EK test cells containing simulated site materials at laboratory and intermediate(m)-scales to: remove, focus or degrade contaminants (remediation or waste minimisation); and direct subsurface water, chemical and colloid flow (fencing/containment or forced migration). This lab-based research is being informed by numerical models of EK processes that can subsequently be used to design full-scale on-site applications by nuclear site holders. Research under theme 2 of TRANSCEND will ultimately combine novel non-invasive detection technologies with EK techniques and colloidal silica grout barriers, to optimise the containment of radionuclide contamination in soils. Thus, allowing us to detect in-situ contamination, mobilise it to a selected location and grout it in-situ, prior to the initiation of decommissioning and deconstruction operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterizing the Influence of Organic Polymers on the Specific Reactivity of Particulate Remedial Amendments

Commercially available particulate amendments demonstrate high reactivity for effective treatment of water soluble organic and inorganic contaminants in laboratory studies; however, transport of these particles is constrained in the subsurface. In many field applications, particulate amendments are mixed with organic polymers to enhance mobility for direct push applications or stabilize suspensions for high mass loadings. As such, the interactions between particulate amendments, organic polymers and contaminant species need to be systematically investigated to properly understand mechanistic processes that facilitate predictive performance metrics for specific applications in situ . In this study, batch experiments were conducted to quantify the effects of organic polymers (xanthan gum, guar gum, and sodium alginate), polymer concentration (800 and 4,000 mg/L), and aging (up to 28 days) on chromate treatment rate and capacity by two classes of amendments: reductants [granular zero-valent iron (gZVI), micron-ZVI (mZVI), sulfur modified iron (SMI)], and an adsorbent (bismuth sub-nitrate). When particulate amendments were suspended in polymer solutions, reductants retained between 84–100% of the amendment treatment capacity. Conversely, the adsorbent maintained 63–97% relative treatment capacity of the no-polymer control. Polymer solutions had a more pronounced impact on the rate of chromate removal; first order rates of chemical reduction decreased by as much as 70% and adsorption by up to 81% relative to the no-polymer controls. Polymer–amendment aging experiments also showed decreased Cr(VI) treatment capacity; reductants decreased by as much as 24% and adsorption decreased by as much as 44% after 28 days of incubation. While polymer suspensions are needed to aid the injection of particulate amendments into the subsurface, the results from this study indicate potential losses of treatment capacity and a decrease in the rate of remedial performance due to the physical and chemical interactions between polymer suspensions and reactive particulate amendments. Simple batch systems provide baseline characterization of tripartite interactions for the removal of Cr(VI). Additional work is needed to quantify the full impact of polymers on remedial outcomes under site relevant conditions at field scale.

54 ENVIRONMENTAL SCIENCES↗

Sampling Artifacts from Conductive Silicone Tubing

We report evidence that carbon impregnated conductive silicone tubing used in aerosol sampling systems can introduce two types of experimental artifacts: 1) silicon tubing dynamically absorbs carbon dioxide gas, requiring greater than 5 minutes to reach equilibrium and 2) silicone tubing emits organic contaminants containing siloxane that adsorb onto particles traveling through it and onto downstream quartz fiber filters. The consequence can be substantial for engine exhaust measurements as both artifacts directly impact calculations of particulate mass-based emission indices. The emission of contaminants from the silicone tubing can result in overestimation of organic particle mass concentrations based on real-time aerosol mass spectrometry and the off-line thermal analysis of quartz filters. The adsorption of siloxane contaminants can affect the surface properties of aerosol particles; we observed a marked reduction in the water-affinity of soot particles passed through conductive silicone tubing. These combined observations suggest that the silicone tubing artifacts may have wide consequence for the aerosol community and should, therefore, be used with caution. Gentle heating, physical and chemical properties of the particle carriers, exposure to solvents, and tubing age may influence siloxane uptake. The amount of contamination is expected to increase as the tubing surface area increases and as the particle surface area increases. The effect is observed at ambient temperature and enhanced by mild heating (<100 oC). Further evaluation is warranted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Environmental Verification Experiment for the Explorer Platform (EVEEP)

Satellites and long-life spacecraft require effective contamination control measures to ensure data accuracy and maintain overall system performance margins. Satellite and spacecraft contamination can occur from either molecular or particulate matter. Some of the sources of the molecular species are as follows: mass loss from nonmetallic materials; venting of confined spacecraft or experiment volumes; exhaust effluents from attitude control systems; integration and test activities; and improper cleaning of surfaces. Some of the sources of particulates are as follows: leaks or purges which condense upon vacuum exposure; abrasion of movable surfaces; and micrometeoroid impacts. The Environmental Verification Experiment for the Explorer Platform (EVEEP) was designed to investigate the following aspects of spacecraft contamination control: materials selection; contamination modeling of existing designs; and thermal vacuum testing of a spacecraft with contamination monitors.

Norris, Bonnie↗

A sampling bottle for fuel and oxidizer.

Sampling bottle with valves and high pressure filter holder for fuel and oxidizer, by weighing bottle before and after sampling amount of fuel passing through filter can be calculated

PROPELLANT OXIDIZER↗

Characterization of selected LDEF: Exposed polymer films and resins

The Long Duration Exposure Facility (LDEF) provided a unique environmental exposure of a wide variety of materials. The effects of 5 years and 10 months of Low-Earth Orbit (LEO) exposure of these materials to atomic oxygen, ultraviolet and particulate radiation, meteoroid and debris, vacuum, contamination, and thermal cycling is providing a data base unparalleled in the history of space environment research. Working though the Environmental Effects on Materials Special Investigation Group (MSIG), a number of polymeric materials in various processed forms have been assembled from LDEF investigators for analysis at the NASA Langley Research Center. This paper reports the status of on-going chemical characterization of these materials.

Young, Philip R.↗

The Applications of Intumescent Technologies in Support of D and D Activities across the DOE Complex - 19599

The development of intumescent technologies to be used as both an excellent means of fire protection and resiliency and as a radioactive fixative, would most definitely benefit the safety of the general public and also the environment. The remediation and safe disposal of radioactive waste is of great important to both national security and the public health, as we carry the responsibility to not develop new ways of mitigating these hazards but also to lay the groundwork for future generations. The overall goal of this research is to enhance the fire resiliency and protection of fixatives and nuclear facilities in support of D and D activities. Specific objectives include: 1) identify and evaluate commercial-off-the-shelf (COTS) intumescent technologies, 2) conduct baseline fire testing of intumescent technologies, 3) develop a set of international standards to meet operational and safety requirements for D and D Technologies. In order to evaluate the above proposed research objectives, the following hypotheses have been postulated. - Select, test, and evaluate the suitability of certain 'near fit' ASTM flammability standards. - Baseline and down-select a set of existing COTS intumescent technologies (coatings and foams) to support D and D problem sets. - Determine feasibility of application methods for use inside a radioactive glovebox and hot cells for D and D purposes. - Develop international testing protocols for adapting the use of intumescent technologies to address needs of the D and D process. The proposed research will primarily take place at FIU-ARC. ARC and SRNL have conducted extensive coordination with the Savannah River Site's (SRS) 235-F PuFF facility personnel to facilitate planning in order to expedite the research and development (R and D) related to this effort. An initial set of documents associated with the specific facility hot cells, including schematics, assessment of the manipulator arms, anticipated particulate sizes of the Pu-238 contamination, an approved tooling list, etc., were formally reviewed and approved for release by the site to ARC. Utilizing these as a foundation, pre-planning for further adaptation of the intumescent technologies and the application during a full-scale cold demo at a hot cell testbed at ARC. One of the primary objectives is the testing and evaluation of the resistance of radiological shielding foams to thermal stressors. This objective was accomplished by conducting a flammability test and incremental temperature test. The goal of the flammability test is to conduct analytical tests to provide a classification for the foams as outlined below in accordance with IEC 60695-11-10. This test method is uniformly accepted throughout the industry as being critical indicators that quantifiably establish the flammability characteristics of plastics. It should be noted that polyurethane is not classified as a plastic, however, they do share similar properties deeming this a near fit test. IEC 60695-11-10:2013 specifies small-scale laboratory test procedures intended to compare the burning behavior of different materials when vertically or horizontally oriented test bar specimens are exposed to a small flame ignition source. Two test methods are described. Method A is a horizontal burning test and is intended to determine the linear burning rate of materials under specific test conditions. Method B is a vertical burning test and is intended to determine whether materials self-extinguish under specific test conditions. The purpose of the incremental temperature testing is to evaluate mass loss and dimensional changes that occurs to the radiological shielding foams when exposed to high temperatures in a muffle furnace. High temperatures often cause materials to undergo physical changes such as swelling or expanding. This is caused by the increase in kinetic energy and atomic and molecular movement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Bidentate Phosphoryl Compounds on Soil Particulates using SIMS

The presence of organic compounds as surface contaminants on particles can provide valuable data about the particles environment, but identification can be analytically challenging. This is true particularly for compounds that have the potential for strong surface binding, such as compounds capable of multidentate attachment. Direct analysis using time-of-flight secondary ion mass spectrometry was evaluated for characterization of soil particles contaminated with low concentrations of two bidentate organophosphoryl compounds, diphenyl-N,N-di-n-butylcarbamoylmethylphosphine oxide and tetraphenylmethylene diphosphine dioxide. Molecular ions were formed by cationization with H+ and alkali elements Na+ and K+ that are indigenous to the particle surface chemistry. Spectra generated from a contaminated calcareous soil were dominated by K+-containing ions, whereas spectra from a sandy loam had more abundant Na+-species. Cation-bound dimers were also formed which favored incorporation of K+, and a unique aluminosilicate-phosphoryl conjugate cation was also formed when the diphosphoryl ligand was present on the surface. The phosphoryl ligands also underwent fragmentation reactions, the course of which varied depending on the cation that was bound. Minimum detectable surface concentrations were evaluated and were in the 0.04-0.2 monolayer range, depending on the compound and soil particle matrix they was bound to. The ion signature was detected on soil particle surfaces for time periods exceeding six months, suggesting that the characterization approach could be used for environmental exposure history at times well beyond initial exposure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗