Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plug loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Characterize the Demand and Energy Characteristics of Direct Current Fast Chargers

The electric vehicle supply equipment (EVSE) deployed by The EV Project included both AC Level 2 (ACL2) and DCFC units. Over 100 of the Blink dual-port DCFCs were deployed by The EV Project. These DCFCs were all publicly accessible, located in workplaces, near traffic hubs, retail centers, parking lots, restaurants, and similar locations. The Blink DCFC dual-port design sequences the charge from one port to the other, delivering power to only one of two vehicles connected at a time. The actual power delivered through a port is determined by the PEV’s on-board battery management system (BMS).The Blink DCFC is capable of charging at power up to 60 kW. For the EV Project, the Nissan Leaf was the only participating PEV capable of accepting a DC charge. The Nissan Leaf BMS allows acceptance of up to 50 kW DC power. At this rate, the DCFC is capable of recharging a Leaf battery from a 30% state of charge (SOC) to an 80% SOC in about 25 minutes. The power required by the DCFC to recharge a plug-in electric vehicle (PEV) can be a significant additional electrical load for the charging site host and contributes to the overall power demand on the electric grid.

33 ADVANCED PROPULSION SYSTEMS↗

What is the Controllable Electrical Demand from Non-Residential Electric Vehicle Supply Equipment in the San Diego Region?

The EVSE deployed by The EV Project included both residential and non-residential units. Approximately 4,000 non-residential AC Level 2 (ACL2) EVSE were installed in workplace environments, fleet applications and publicly accessible locations near retail centers, parking lots, and similar locations. The power required to recharge a plug-in electric vehicle (PEV) can be a significant additional electrical load to electric grid but may also provide a controllable resource for mitigating grid overload issues. Electric utilities seek ways to reduce their generating costs by controlling the maximum (peak) load on their system, their generating resources, and frequency and voltage control on the system. This management may be achieved indirectly, through rates that incentivize their customers (including PEV owners) to manage the charging of their vehicles, or may take the form of direct utility control of non-residential EVSE. What insight can The EV Project data provide related to the magnitude of this impact and the potential controllable demand? The paper What is the Controllable Electrical Demand from Residential EVSE in the San Diego Region?1 addressed this question for residential EVSE. This paper quantifies the total controllable electrical load imposed on the electric grid by non-residential PEV charging in the San Diego region of The EV Project.

33 ADVANCED PROPULSION SYSTEMS↗

Signal conditioner test set

A system was developed for testing components contained in a signal conditioning module with a transistor and capacitor included in a circuit. The system includes a housing with a socket into which the module to be tested is plugged. A test switch is provided for selectively connecting a variable load to either a transistor or capacitor in the circuit for testing the operation. A signal generating circuit is provided for generating signals for use in testing the components of the module.

Houck, W. H.↗

Long-Term Carbon Injection Field Test for 90% Mercury Removal for a PRB Unit a Spray Dryer and Fabric Filter

The power industry in the U.S. is faced with meeting regulations to reduce the emissions of mercury compounds from coal-fired plants. Injecting a sorbent such as powdered activated carbon (PAC) into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. The purpose of this test program was to evaluate the long-term mercury removal capability, long-term mercury emissions variability, and operating and maintenance (O&M) costs associated with sorbent injection on a configuration being considered for many new plants. Testing was conducted by ADA Environmental Solutions (ADA) at Rocky Mountain Power’s (RMP) Hardin Station through funding provided by DOE/NETL, RMP, and other industry partners. The Hardin Station is a new plant rated at 121 MW gross that was first brought online in April of 2006. Hardin fires a Powder River Basin (PRB) coal and is configured with selective catalytic reduction (SCR) for NOx control, a spray dryer absorber (SDA) for SO2 control, and a fabric filter (FF) for particulate control. Based upon previous testing at PRB sites with SCRs, very little additional mercury oxidation from the SCR was expected at Hardin. In addition, based upon results from DOE/NETL Phase II Round I testing at Holcomb Station and results from similarly configured sites, low native mercury removal was expected across the SDA and FF. The main goal of this project was met—sorbent injection was used to economically and effectively achieve 90% mercury control as measured from the air heater (AH) outlet to the stack for a period of ten months. This goal was achieved with DARCO® Hg-LH, Calgon FLUEPAC®-MC PLUS and ADA Power PAC PREMIUM brominated activated carbons at nominal loadings of 1.5–2.5 lb/MMacf. An economic analysis determined the twenty-year levelized cost to be 0.87 mills/kW-hr, or $15,000/lb Hg removed. No detrimental effects on other equipment or plant operations were observed. The results of this project also filled a data gap for plants firing PRB coal and configured with an SCR, SDA, and FF, as many new plants are being designed today. Another goal of the project was to evaluate, on a short-term basis, the mercury removal associated with coal additives and coal blending with western bituminous coal. The additive test showed that, at this site, the coal additive known as KNX was affective at increasing mercury removal while decreasing sorbent usage. Coal blending was conducted with two different western bituminous coals, and West Elk coal increased native capture from nominally 10% to 50%. Two additional co-benefits were discovered at this site. First, it was found that native capture increased from nominally 10% at full load to 50% at low load. The effect is believed to be due to an increase in mercury oxidation across the SCR caused by a corresponding decrease in ammonia injection when the plant reduces load. Less ammonia means more active oxidation sites in the SCR for the mercury. The second co-benefit was the finding that high ammonia concentrations can have a negative impact on mercury removal by powdered activated carbon. For a period of time, the plant operated with a high excess of ammonia injection necessitated by the plugging of one-third of the SCR. Under these conditions and at high load, the mercury control system could not maintain 90% removal even at the maximum feed rate of 3.5 lb/MMacf (pounds of mercury per million actual cubic feet). The plant was able to demonstrate that mercury removal was directly related to the ammonia injection rate in a series of tests where the ammonia rate was decreased, causing a corresponding increase in mercury removal. Also, after the SCR was refurbished and ammonia injection levels returned to normal, the mercury removal performance also returned to normal. Another goal of the project was to install a commercial-grade activated carbon injection (ACI) system and integrate it with new-generation continuous emissions monitors for mercury (Hg-CEMs) to allow automatic feedback control on outlet mercury emissions. This was accomplished and the plant can now be operated to control carbon injection based on either the overall mercury removal or an outlet mercury emission rate. By integrating these systems, it was determined that the plant could reduce powdered activated carbon consumption, especially at low load, because, at Hardin, native mercury capture increases from less than 20% to about 50% at low load and the carbon injection rate can be decreased accordingly. Currently, the plant is operating to automatically control emissions to below 0.9 lb/TBtu (pounds of mercury per million British thermal units) at carbon loadings of 0.5 to 1.5 lb/MMacf. During the final phase of the Long-Term test, the ACI system was operated by plant personnel. The estimated O&M cost for a single Hg-CEM system is $15,500/yr. The Hg-CEMs performed well throughout the project. This project began shortly after Thermo Fisher first offered the Mercury Freedom System™ on a commercial basis and progressed though several iterations, improvements, and upgrades to the hardware and software. Indeed, there was a ten-fold increase in the precision and accuracy of the units during the course of the project due to several successful upgrades. In their present condition, the Hg-CEMs measure mercury to a precision of about ± 0.05 μg/wscm (micrograms of mercury per wet standard cubic meter of gas), and only require occasional fine-tuning of the calibration coefficients. The quality assurance/quality control (QA/QC) protocol required to keep the units operating at their optimal performance was also developed and perfected during the course of the project. ADA Environmental Solutions (ADA) developed a daily calibration procedure that surpasses the requirements specified in the Clean Air Mercury Rule (CAMR), and a weekly diagnostic program that ensures that the systems are operating properly and receive the necessary maintenance. For the most part, the systems passed the daily, weekly, and quarterly QA/QC requirements as well as four performance verification tests using the Ontario Hydro (O-H) and Sorbent Trap Methods (STM) for the first test and the EPA Method 30A (M30A) procedure for the remaining three. However, some improvements are still necessary before the system can meet all of the requirements. These involve tests that challenge the system with oxidized mercury (Hg+2). These tests could not be passed at Hardin in spite of trying several improvements suggested by ADA or Thermo Fisher.

20 FOSSIL-FUELED POWER PLANTS↗

Superfluid helium 2 liquid-vapor phase separation: Technology assessment

A literature survey of helium 2 liquid vapor phase separation is presented. Currently, two types of He 2 phase separators are being investigated: porous, sintered metal plugs and the active phase separator. The permeability K(P) shows consistency in porous plug geometric characterization. Both the heat and mass fluxes increase with K(P). Downstream pressure regulation to adjust for varying heat loads and both temperatures is possible. For large dynamic heat loads, the active phase separator shows a maximum heat rejection rate of up to 2 W and bath temperature stability of 0.1 mK. Porous plug phase separation performance should be investigated for application to SIRTF and, in particular, that plugs of from 10 to the minus ninth square centimeters to 10 to the minus eighth square centimeters in conjunction with downstream pressure regulation be studied.

Lee, J. M.↗

Design and Analysis Progress of ITER Diagnostic Equatorial Port #09

ITER is the world's largest fusion device currently under construction in the South of France with >50 diagnostic systems to be installed inside the port plugs (PPs), the interspace (IS), or the port cell region of various diagnostic ports. The plasma facing diagnostic first wall (DFW) and its supporting diagnostic shield modules (DSM) are designed to protect front-end diagnostics from plasma neutron and plasma radiation, while providing apertures for diagnostic access to the plasma. The design of ITER port plug structures including the DFW and the DSM is largely driven by the electromagnetic loads included on the PP structural components during plasma major disruptions and the vertical displacement events (VDEs). Unlike DFW and DSM, the design of diagnostic system, however, is likely driven by the steady-state thermal loads from plasma volumetric and surface heating and the dynamic response of the in-port components attached to the port-specific DSM or closure plate under transient loads induced on the vacuum vessel and the port extension during asymmetric VDEs. Three tenant diagnostic systems are integrated into the equatorial port 09. The toroidal interferometer/polarimeter, or TIP system, is installed in the left drawer (DSM3, left looking from plasma) for measuring the plasma density so to control the fuel input. The electron cyclotron emission (ECE) system is installed in the middle drawer (DSM2) to provide the high spatial and temporal resolution measurements of electron temperature evolution and the electron thermal transport inferences. The visible/infrared wide angle viewing system is installed in the right drawer (DSM1) to provide visible and infrared viewing and temperature data of the first wall for its protection in support of machine operation. The port plug integration design and multiphysics analyses are performed following port integration requirements including the weight limit (45 tones total), shut down dose rate limits, the cooling/heating and structural integrity validation. Mass distribution for TIP and ECE DSMs has been optimized to minimize the total weight by a new design of the boron carbide shielding pocket. Furthermore, the lightened DSM maintains its front-end load distribution and the structural stiffness with minimum impact to the DFW so to better protect on-board diagnostics; while still provides sufficient front-end stiffness for its structural integrity as well as the diagnostics function requirements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RCC Plug Repair Thermal Tools for Shuttle Mission Support

A thermal math model for the Space Shuttle Reinforced Carbon-Carbon (RCC) Plug Repair was developed to increase the confidence in the repair entry performance and provide a real-time mission support tool. The thermal response of the plug cover plate, local RCC, and metallic attach hardware can be assessed with this model for any location on the wing leading edge. The geometry and spatial location of the thermal mesh also matches the structural mesh which allows for the direct mapping of temperature loads and computation of the thermoelastic stresses. The thermal model was correlated to a full scale plug repair radiant test. To utilize the thermal model for flight analyses, accurate predictions of protuberance heating were required. Wind tunnel testing was performed at CUBRC to characterize the heat flux in both the radial and angular directions. Due to the complexity of the implementation of the protuberance heating, an intermediate program was developed to output the heating per nodal location for all OML surfaces in SINDA format. Three Design Reference Cases (DRC) were evaluated with the correlated plug thermal math model to bound the environments which the plug repair would potentially be used.

Rodriguez, Alvaro C.↗

Recoil-Implantation Of Multiple Radioisotopes Towards Wear Rate Measurements And Particle Tracing In Prosthetic Joints

This study demonstrates a new method of radioisotope labeling of ultra-high molecular weight polyethylene inserts in prosthetic joints for wear studies. The radioisotopes {sup 97}Ru, {sup 100}Pd, {sup 100}Rh, and {sup 101m}Rh are produced in fusion evaporation reactions induced by {sup 12}C ions in a {sup 92}Zr target foil. The fusion products recoil-implant into ultra-high molecular weight polyethylene plugs, machined to fit into the surface of the inserts. During laboratory simulations of the joint motion, a wear rate of the labeled polyethylene may be measured and the pathways of wear debris particles can be traced by detecting characteristic gamma-rays. The concentration profiles of the radioisotopes extend effectively uniformly from the polyethylene surface to a depth of about 4 {mu}m. The multiplicity of labeling and the use of several gamma-ray lines aids with avoiding systematic measurement uncertainties. Two polyethylene plugs were labeled and one was fitted into the surface of the tibial insert of a knee prosthesis, which had been worn in. Actuation over close to 100,000 cycles with a 900 N axial load and a 24 deg. flexion angle removed (14{+-}1)% of the gamma-ray activity from the plug. Most of this activity dispersed into the serum lubricant identifying this as the important debris pathway. Less than 1% activity was transferred to the femoral component of the prosthesis and the measured activity on the tibial tray was insignificant. Assuming uniform wear across the superior surface of the insert, a wear rate of (12{+-}3) mm{sup 3}/Megacycle was determined. This is consistent with wear rate measurements under similar conditions using other techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-State Load Models for Distribution System Analysis

Recent work in the field of distribution system analysis has shown that the traditional method of peak load analysis is not adequate for the analysis of emerging distribution system technologies. Voltage optimization, demand response, electric vehicle charging, and energy storage are examples of technologies with characteristics having daily, seasonal, and/or annual variations. In addition to the seasonal variations, emerging technologies such as demand response and plug in electric vehicle charging have the potential to send control signals to the end use loads which will affect how they consume energy. In order to support time-series analysis over different time frames and to incorporate potential control signal inputs it is necessary to develop detailed end use load models which accurately represent the load under various conditions, and not just during the peak load period. This paper will build on previous work on detail end use load modeling in order to outline the method of general multi-state load models for distribution system analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact Assessment of Plug-In Hybrid Vehicles on Pacific Northwest Distribution Systems

The U.S. electric power infrastructure is a significantly underutilized strategic asset which, with the proper shift in operational paradigms, could provide a significant portion of the energy requirements for the existing light duty vehicle (LDV) fleet. This shift would result in reduced emissions, improved economics for utilities, and a reduced dependence on oil. A previous study has shown that the existing generation and transmission assets of the electric power infrastructure could feasibly supply the electricity for about 70% of the U.S. LDV fleet [1]. The limitations of the distribution system were not explicitly addressed and are more difficult to quantify because of the large diversity of distribution systems topology, design guidelines and load growth. This paper focuses on the impacts of a high penetration of Plug-In Electric Hybrid Vehicles (PHEVs) on the distribution systems. Presented are results specific for the Pacific Northwest.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Demand Response and Smart Buildings: A Survey of Control, Communication, and Cyber-Physical Security

In this paper, we perform a comprehensive survey of the technical aspects related to the implementation of demand response and smart buildings. Specifically, we discuss various smart loads such as heating, ventilating, and air-conditioning (HVAC) systems and plug-in electric vehicles (PEVs); the power architecture with multibus characteristics; different control algorithms such as the hybrid centralized and decentralized control and the distributed coordination among buildings; the communication technologies and network architectures; and the potential cyber-physical security issues and possible mechanisms for enhancing the system security at both cyber and physical layers. Finally, the current status of the demand response in United States, Europe, Japan, and China is reviewed, and the benefits, costs, and challenges of implementing and operating demand response and smart buildings are also discussed.

42 ENGINEERING↗

Refining Control, Charging, and Battery Chemistry for CO 2 e Savings in Heavy-Duty Off-Road Plug-In Series Hybrid

With current and future regulations continuing to drive reductions in carbon dioxide equivalent (CO 2 e) emissions in the on-road industry, the off-road industry is also likely to be regulated for fuel and CO 2 e savings. This work focuses on converting a heavy-duty off-road material handler from a conventional diesel powertrain to a plug-in series hybrid, achieving a 49% fuel reduction and 29% CO 2 e reduction via simulation. Control strategies were refined for energy savings, including a regenerative braking strategy to increase regenerative braking and a load-following hydraulic strategy to decrease electrical energy consumption. The load-following hydraulic control shuts off the hydraulic electric machine when it is not needed—an approach not previously seen in a load-sensing, pressure-compensated system. Furthermore, these strategies achieved a 24.1% fuel savings, resulting in total savings of 61% in fuel and 41% in CO 2 e in the plug-in series compared to the conventional machine. Beyond control strategies, this study evaluated battery chemistry and charging strategy refinements for total cost of ownership (TCO) and lifetime CO 2 e. LFP batteries emerged as the most cost-effective and least emitting due to their longer lifespan, which reduced replacement frequency. Charging comparisons showed that Level 2 charging (L2C) typically resulted in lower TCO but higher lifetime CO 2 e than DC fast charging (DCFC). DCFC costs were heavily influenced by local demand charges, and DCFC emissions were heavily influenced by local grid emissions.

33 ADVANCED PROPULSION SYSTEMS↗

Performance of the ITER ICRF Antenna plug as expected from TOPICA matrices

The performances of the present ICRF antenna plug design is evaluated by means of the TOPICA 24x24 matrix for plasma loading supplemented by 4-port junction (4PJ) matrices. For their interpretation these results are compared with a cruder modeling by the semi-analytical code ANTITER II. From this analysis we conclude: (1) The broadbanding effect of the service stub on the response of the 4PJ made for one triplet is maintained for the complete array for all the heating and current drive phasings. (2) For a given maximum voltage of the 8 feeding lines the radiated power capability is roughly constant in the entire frequency band. (3) The power capability of the array is significantly dependent on the distance of the antenna to the Last Closed Flux Surface, the density profile in the scrape-off layer (SOL) and on the toroidal and poloidal phasings. The dependence on phasing is stronger for wider SOL (4) For a not too optimistic plasma density profile (Sc2 shortl7) a power capability exceeding 20 MW is only obtained for the 00 {pi}{pi} heating toroidal phasing and for the co-current drive phasing in the upper part of the frequency band for a maximum voltage in the complete system of 45 kV. (5), On account of the plasma gyrotropy the quadrature poloidal phasing introduced by hybrid feeding must excite waves propagating upwards in the ITER configuration to obtain the best coupling, (6) The large power capability difference between opposite current drive phasings is attributed to the coupling between the toroidal and poloidal phasings induced by the poloidal steady magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Guest Editorial Special Issue on Wireless Charging Systems

Wireless power transfer is a safe and convenient method for electric vehicle (EV) charging. And, if designed properly, it can be highly efficient. Applications cover a wide range of power transfer levels from less than a kilowatt to a few hundreds of kilowatts with transfer distances from a few millimeters to a few hundreds of millimeters. Applications also cover stationary, dynamic (in-motion), or quasi dynamic wireless charging systems. Safety is inherent in wireless power transfer systems due to the large airgap separation between the source and load sides, and users do not have to touch any cables, connectors, or plugs at all. With the recent advancements in automation, parking aid systems can be integrated and the wireless charging process can be a simple “park and go” approach without requiring any input from the driver.When applied in motion, wireless charging can be the ultimate end of game in transportation electrification, providing reduced battery size and cost with unlimited range for EVs. This approach is also known as ”charge-on-the-go” or “roadway powered vehicle” concept. While the connected and automated vehicles can self-drive and self-park, they currently cannot self-charge. Furthermore, wireless charging is a key enabling technology for the widespread development and adoption of connected and automated vehicle technology for the future of smart mobility.

33 ADVANCED PROPULSION SYSTEMS↗

High-Thermal-Conductivity Fabrics

Heat management with common textiles such as nylon and spandex is hindered by the poor thermal conductivity from the skin surface to cooling surfaces. This innovation showed marked improvement in thermal conductivity of the individual fibers and tubing, as well as components assembled from them. The problem is centered on improving the heat removal of the liquid-cooled ventilation garments (LCVGs) used by astronauts. The current design uses an extensive network of water-cooling tubes that introduces bulkiness and discomfort, and increases fatigue. Range of motion and ease of movement are affected as well. The current technology is the same as developed during the Apollo program of the 1960s. Tubing material is hand-threaded through a spandex/nylon mesh layer, in a series of loops throughout the torso and limbs such that there is close, form-fitting contact with the user. Usually, there is a nylon liner layer to improve comfort. Circulating water is chilled by an external heat exchanger (sublimator). The purpose of this innovation is to produce new LCVG components with improved thermal conductivity. This was addressed using nanocomposite engineering incorporating high-thermalconductivity nanoscale fillers in the fabric and tubing components. Specifically, carbon nanotubes were added using normal processing methods such as thermoplastic melt mixing (compounding twin screw extruder) and downstream processing (fiber spinning, tubing extrusion). Fibers were produced as yarns and woven into fabric cloths. The application of isotropic nanofillers can be modeled using a modified Nielsen Model for conductive fillers in a matrix based on Einstein s viscosity model. This is a drop-in technology with no additional equipment needed. The loading is limited by the ability to maintain adequate dispersion. Undispersed materials will plug filtering screens in processing equipment. Generally, the viscosity increases were acceptable, and allowed the filled polymers to still be processed.The novel feature is that fabrics do not inherently possess good thermal conductivity. In fact, fabrics are used for thermal insulation, not heat removal. The technology represents the first material that is a wearable fabric, based on company textiles and materials that will significantly conduct heat.

Chibante, L. P. Felipe↗

Transportation Electrification Load Development For a Renewable Future Analysis

Electrification of the transportation sector offers the opportunity to significantly reduce petroleum consumption. The transportation sector accounts for 70% of US petroleum consumption. The transition to electricity as a transportation fuel will create a new load for electricity generation. In support of a recent US Department of Energy funded activity that analyzed a future generation scenario with high renewable energy technology contributions, a set of regional hourly load profiles for electrified vehicles were developed for the 2010 to 2050 timeframe. These load profiles with their underlying assumptions will be presented in this paper. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determine the number of plug-in electric vehicles (PEVs) in each analysis region. Two market saturation scenarios of 30% of sales and 50% of sales of PEVs consuming on average {approx}6 kWh per day were considered. Results were generated for 3109 counties and were consolidated to 134 Power Control Areas (PCA) for the use NREL's's regional generation planning analysis tool ReEDS. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging toward utility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across 4 daily time slices under optimal control from the utility perspective. No other literature has addressed the potential flexibility in energy delivery to electric vehicles in connection with a regional power generation study. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetration scenarios. EVS25 Copyright.

02 PETROLEUM↗

Demonstration of improved dilution tolerance using a production-intent compact nanosecond pulse ignition system

Transient plasma ignition using nanosecond pulses has demonstrated the potential to enable improved fuel economy and reduced emissions by enabling lean and EGR limit extension in dilute burn engines. Existing spark ignition technology is not adequate because the energy transfer mechanisms between the spark and the fuel-air mixture are not efficient enough to guarantee stable ignition for dilute mixtures at high-load conditions. Additionally, long duration sparks and other advanced ignition solutions that require increased energy delivered accelerate spark plug electrode wear. To date, non-thermal plasma ignition with nanosecond pulses have demonstrated a lean ignition limit beyond an air/fuel ratio of 24 [1], demonstrated high-pressure ignition at densities equivalent to over 100 bar at the time of ignition [2], and demonstrated stable (COV <3 %) ignition at EGR dilution levels >20 % [3]. While low-energy nanosecond pulses have demonstrated strong performance compared to existing solutions, they currently only exist on the market in laboratory systems, rather than a production ready system in a single rugged, weather-proof, under-the-hood enclosure. Transient Plasma Systems (TPS) has recently demonstrated the potential for a retroffitable solution similar to coil-on-plug architecture that allows a direct replacement of existing ignition technology without any engine modification. The system was run on a gasoline direct injection engine at Argonne National Laboratory and demonstrated the same trends as previously observed with research grade systems, including lean and EGR limit extension and more stable ignition across a range of loads. The system was capable of delivering 30 kV pulses in bursts of up to 20 pulses at 30 kHz, and demonstrated stable combustion at an air/fuel ratio of 23.5, exhaust gas recirculation of 23 %, and ignition at 19.2 bar with COV <3 % using only 20 kV pulses.

nanosecond pulsed power↗