Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pool boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

BWR Spent Nuclear Fuel Integrity Research and Development Survey for UKABWR Spent Fuel Interim Storage

The objective of this report is to identify issues and support documentation and identify and detail existing research on spent fuel dry storage; provide information to support potential R&D for the UKABWR (United Kingdom Advanced Boiling Water Reactor) Spent Fuel Interim Storage (SFIS) Pre-Construction Safety Report; and support development of answers to questions developed by the regulator. Where there are gaps or insufficient data, Oak Ridge National Laboratory (ORNL) has summarized the research planned to provide the necessary data along with the schedule for the research, if known. Spent nuclear fuel (SNF) from nuclear power plants has historically been stored on site (wet) in spent fuel pools pending ultimate disposition. Nuclear power users (countries, utilities, vendors) are developing a suite of options and set of supporting analyses that will enable future informed choices about how best to manage these materials. As part of that effort, they are beginning to lay the groundwork for implementing longer-term interim storage of the SNF and the Greater Than Class C (CTCC) waste (dry). Deploying dry storage will require a number of technical issues to be addressed. For the past 4-5 years, ORNL has been supporting the U.S. Department of Energy (DOE) in identifying these key technical issues, managing the collection of data to be used in issue resolution, and identifying gaps in the needed data. During this effort, ORNL subject matter experts (SMEs) have become expert in understanding what information is publicly available and what gaps in data remain. To ensure the safety of the spent fuel under normal and frequent conditions of wet and subsequent dry storage, intact fuel must be shown to: 1.Maintain fuel cladding integrity; 2.Maintain its geometry for cooling, shielding, and subcriticality; 3.Maintain retrievability, and damaged fuel with pinhole or hairline cracks must be shown not to degrade further. Where PWR (pressurized water reactor) information is utilized or referenced, justification has been provided as to why the data can be utilized for BWR fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fundamental approaches for analysis thermal hydraulic parameter for Puspati Research Reactor

The 1-MW PUSPATI Research Reactor (RTP) is the one and only nuclear pool type research reactor developed by General Atomic (GA) in Malaysia. It was installed at Malaysian Nuclear Agency and has reached the first criticality on 8 June 1982. Based on the initial core which comprised of 80 standard TRIGA fuel elements, the very fundamental thermal hydraulic model was investigated during steady state operation using the PARET-code. The main objective of this paper is to determine the variation of temperature profiles and Departure of Nucleate Boiling Ratio (DNBR) of RTP at full power operation. The second objective is to confirm that the values obtained from PARET-code are in agreement with Safety Analysis Report (SAR) for RTP. The code was employed for the hot and average channels in the core in order to calculate of fuel’s center and surface, cladding, coolant temperatures as well as DNBR’s values. In this study, it was found that the results obtained from the PARET-code showed that the thermal hydraulic parameters related to safety for initial core which was cooled by natural convection was in agreement with the designed values and safety limit in SAR.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of simulation predictions of hydrocarbon pool fire tests.

An uncertainty quantification (UQ) analysis is performed on the fuel regression rate model within SIERRA/Fuego by comparing to a series of hydrocarbon tests performed in the Thermal Test Complex. The fuels used for comparison for the fuel regression rate model include methanol, ethanol, JP8, and heptane. The recently implemented flamelet combustion model is also assessed with a limited comparison to data involving measurements of temperature and relative mole fractions within a 2-m diameter methanol pool fire. The comparison of the current fuel regression rate model to data without UQ indicates that the model over predicts the fuel regression rate by 65% for methanol, 63% for ethanol, 95% for JP8, and 15% for heptane. If a UQ analysis is performed incorporating a range of values for transmittance, reflectance, and heat flux at the surface the current model predicts fuel regression rates within 50% of measured values. An alternative model which uses specific heats at inlet and boiling temperatures respectively and does not approximate the sensible heat is also compared to data. The alternative model with UQ significantly improves the comparison to within 25% for all fuels except heptane. Even though the proposed alternative model provides better agreement to data, particularly for JP8 and ethanol (within 15%), there are still outstanding issues regarding significant uncertainties which include heat flux gauge measurement and placement, boiling at the fuel surface, large scale convective motion within the liquid, and semi-transparent behavior.

10 SYNTHETIC FUELS↗

Damaged Fuel in the United States - 20325

Throughout the history of commercial nuclear power plant operations in the U.S., many fuel assemblies have lost the capability to perform all of their desired functions. Since they can no longer be handled, stored, or transported in accordance with established regulations, they are classified as damaged fuel. The causes of these failed assemblies are diverse and plant-specific. The majority of these failed assemblies are contained in damaged fuel cans to be used in conjunction with storage and/or transportation systems. These systems have a limited number of slots that can be filled with damaged fuel cans. A damaged fuel can is generally a stainless-steel container that confines damaged spent nuclear fuel (SNF) and is closed at one end by mesh endpoints that allow gaseous and liquid media to escape but minimize the dispersal of gross particulate material. Out of extreme caution, a few reactors have loaded high burnup fuel into damaged fuel cans. Damaged fuel is not licensed for storage or transport in the U.S. because relevant regulations do not specify exactly how to classify damaged fuel. Instead, these regulations license/certify packages that specify approved contents. Damaged fuel must be included among the approved contents to be considered acceptable. In many cases, damaged SNF is encapsulated in damaged fuel cans to ensure it can confine gross fuel particles, debris, and/or damaged assemblies to known volumes within loaded casks. A damaged fuel can may then be utilized in the same way as an assembly in a storage and transportation system. Some storage cask systems utilize top and bottom plugs to confine debris in damaged fuel. The most recent domestic documentation on damaged SNF was published by the U.S. Energy Information Administration (EIA), which used data from U.S. reactors compiled from 1968 to June 30, 2013, to produce Form GC-859, 'Nuclear Fuel Data Survey.' According to this form, there were 136,821 boiling water reactor (BWR) SNF assemblies and 104,647 pressurized water reactor (PWR) SNF assemblies, for a combined total of 241,468. Of these, 4,521 were classified as failed. Some were also disassembled and the fuel rods or pieces of fuel rods combined to make consolidated assemblies. These consolidated assemblies may include damaged fuel or were perhaps consolidated as part of a demonstration project. The GC-859 data includes 2,550 consolidated assemblies containing 0 - 264 entire fuel rods. These consolidated assemblies could be placed in single assembly canisters and stored in the spent fuel pool. For dry storage and transportation, a single assembly canister is generally placed in each damaged fuel can. In addition to the consolidated assemblies, 2,391 un-canistered fuel rod pieces exist, which were removed from 494 assemblies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Highly Selective Condensation of Biomass-Derived Methyl Ketones as a Source of Aviation Fuel

Aviation fuel (i.e., jet fuel) requires a mixture of C 9 -C 16 hydrocarbons having both a high energy density and a low freezing point. While jet fuel is currently produced from petroleum, increasing concern with the release of CO 2 into the atmosphere from the combustion of petroleum-based fuels has led to policy changes mandating the inclusion of biomass-based fuels into the fuel pool. Here we report a novel way to produce a mixture of branched cyclohexane derivatives in very high yield (>94 %) that match or exceed many required properties of jet fuel. As starting materials, we use a mixture of n -alkyl methyl ketones and their derivatives obtained from biomass. Here, these synthons are condensed into trimers via base-catalyzed aldol condensation and Michael addition. Hydrodeoxygenation of these products yields mixtures of C 12 -C 21 branched, cyclic alkanes. Using models for predicting the carbon number distribution obtained from a mixture of n-alkyl methyl ketones and for predicting the boiling point distribution of the final mixture of cyclic alkanes, we show that it is possible to define the mixture of synthons that will closely reproduce the distillation curve of traditional jet fuel.

biofuels↗

Damaged Fuel in the United States

Over the years of commercial nuclear power plant operations in the United States (U.S.), many fuel assemblies have lost the capability to perform all of their desired functions. These assemblies have lost the capability to be handled, stored, or transported to meet regulations resulting in them being classified as damaged fuel. The causes of these failed assemblies are diverse and plant-specific. The majority of these failed assemblies are contained in a damaged fuel can that will be used in conjunction with a storage and/or transportation system. The storage and transportation systems have a limit on how many slots can be filled with damaged fuel cans. A damaged fuel can is generally a stainless steel container that confines damaged SNF and is closed on its end by screened openings. These screened openings allow gaseous and liquid media to escape but minimize the dispersal of gross particulate material. Out of an abundance of caution a few reactors have loaded high burnup fuel into damaged fuel cans. Damaged fuel is not licensed for storage or transport in the U.S., because the regulations for storage and transport do not specify exactly how to classify damaged fuel. Instead the regulations license/certify packages that specify approved contents. Damaged fuel must be included in the approved contents to be a viable option. In many cases damaged SNF is encapsulated in a damaged fuel can to ensure it can confine gross fuel particles, debris, and or damaged assemblies to a known volume within a loaded cask. This damaged fuel can may then be utilized in the same way as an assembly in a storage and transportation design system. Some storage cask systems utilize top and bottom plugs to confine debris in damaged fuel. The most recent domestic documentation on damaged SNF was performed by the U.S. Energy Information Administration (EIA) and used data from U.S. reactors concluding in June 30th 2013 to produce Form GC-859, “Nuclear Fuel Data Survey”. Based on this form there were 136,821 boiling water reactor (BWR) spent nuclear fuel (SNF) assemblies and 104,647 pressurized water reactor (PWR) SNF assemblies for a total of 241,468 SNF assemblies in the U.S. Out of these 241,468 SNF assemblies, 4,521 assemblies were classified as failed. Some assemblies were also disassembled and the fuel rods or pieces of fuel rods were combined together to make a consolidated assembly. A consolidated assembly may include damaged fuel, or it could have been consolidated as part of a demonstration project. The GC-859 data includes 2,550 consolidated assemblies containing between 0 and 264 whole fuel rods. These consolidated assemblies could be placed in single assembly canisters and stored in the spent fuel pool. For dry storage and transportation, a single assembly canister is generally placed in a damaged fuel can. In addition to the consolidated assemblies, 2,391 uncanistered fuel rod pieces exist, which were removed from 494 assemblies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calculation of Critical Heat Flux Using an Inverse Heat Transfer Method to Support TREAT Experiment Analysis

Heat transfer between cladding and coolant during transient scenarios remains a critical area of uncertainty in understanding nuclear reactor safety. To advance the understanding of transient and accident scenarios involving critical heat flux (CHF), an in-pile experiment for the Transient Reactor Test (TREAT) facility at Idaho National Laboratory was developed. The experiment named CHF-Static Environment Rodlet Transient Test Apparatus (CHF-SERTTA), consists of a hollow borated stainless steel heater rod submerged in a static water pool which is heated via the (n, a) reaction in boron-10. This paper presents a novel inverse heat transfer method to determine CHF by using the optimization and uncertainty software DAKOTA to calibrate a RELAP5-3D model of CHF-SERTTA to temperature measurements obtained from a thermocouple welded to the surface of the rod.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spent Nuclear Fuel Canister Capacity: Have the Limits Been Reached?

The commercial US nuclear utilities have been transferring spent nuclear fuel (SNF) from spent fuel pools (SFPs) to dry storage systems since 1986. SFPs were initially constructed for temporary storage, but without SNF reprocessing options in the United States and with no final disposal pathway yet available,SFPs started to reach capacity. Hence, to allow continued operation of the nation’s commercial nuclearreactor fleet, utilities started transferring SNF from SFPs (wet storage) to dry storage. Dry storage systems have evolved from storage-only systems first loaded in 1986 to the high-capacity dual-purpose storage and transport canisters used today. A question has arisen as to whether maximum canister capacity has been reached at the current capacity of ~50 kW heat load for storage, with 37-assembly pressurized water reactor and 89-assembly boiling water reactor canisters. This paper presents a holistic overview of commercial US SNF management practices over the years, the current SFP status in terms of filled (occupied) and empty (available) locations, the expected future reactor discharges, and the decay heat load distribution of SFP inventories as of June 2013. Finally, the paper makes a case that further increase in dry storage system capacity both in terms of number of assemblies and decay heat (1) is not needed, and (2) may not be practical from the cost-benefit perspective. b

Banerjee, Kaushik↗

A review of inherent safety characteristics of metal alloy sodium-cooled fast reactor fuel against postulated accidents

The thermal, mechanical, and neutronic performance of the metal alloy fast reactor fuel design complements the safety advantages of the liquid metal cooling and the pool-type primary system. Together, these features provide large safety margins in both normal operating modes and for a wide range of postulated accidents. In particular, they maximize the measures of safety associated with inherent reactor response to unprotected, double-fault accidents, and to minimize risk to the public and plant investment. High thermal conductivity and high gap conductance play the most significant role in safety advantages of the metallic fuel, resulting in a flatter radial temperature profile within the pin and much lower normal operation and transient temperatures in comparison to oxide fuel. Despite the big difference in melting point, both oxide and metal fuels have a relatively similar margin to melting during postulated accidents. When the metal fuel cladding fails, it typically occurs below the coolant boiling point and the damaged fuel pins remain cool-able. Metal fuel is compatible with sodium coolant, eliminating the potential of energetic fuel coolant reactions and flow blockages. All these, and the low retained heat leading to a longer grace period for operator action, are significant contributing factors to the inherently benign response of metallic fuel to postulated accidents. This paper summarizes the past analytical and experimental results obtained in past sodium-cooled fast reactor safety programs in the United States, and presents an overview of fuel safety performance as observed in laboratory and in-pile tests.

inherent safety↗

Two-zone stratified wetwell model development and implementation for RELAP-7

The Reactor Core Isolation Cooling (RCIC) system consists of a turbine, pump and wetwell and is used in many US Boiling Water Reactors (BWRs) as an important heat removal system. The wetwell is a major heat sink within containment. Experimental investigations have shown that thermal stratification may occur in the wetwell during RCIC operation. Current systems-level analysis codes lack stratified wetwell models. Here, this paper describes the development of a stratified wetwell model for the RELAP-7 code. This paper uses a simple two-zone model for the wetwell water that can capture thermal stratification. This model assumes that a buoyant plume transports heat and mass from the steam injection site to the upper water zone. The buoyant plume assumption requires that steam is injected at a low enough rate so it adds negligible momentum. Model validation against experimental data shows similar trends of temperature field development in the suppression pool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Hydraulics Safety Analyses of TRIGA Reactor Upon Fuel Reconfiguration

Safety analyses of the Training, Research, Isotope, General Atomics (TRIGA) reactor at Kansas State University(KSU) is performed using thermal hydraulic simulations based on changes to reactivity or the volumetric heat generation rate due to changes in the positioning of the enriched fuel elements in the reactor core. If the reactivity or neutronics parameters are known, then they can be used to simulate the thermal energy state of the material which is crucial to assess the safety of the nuclear fuel inside a nuclear reactor. Several thermal hydraulics models and codes have been developed in the past to assess reactor safety. RELAP (Reactor Excursion and Leak Analysis Program) is one such tool widely used throughout the world for safety analyses. Although RELAP is considered a reliable tool by regulators, vendors, and operators, it lacks the numerical fidelity provided by 3-D computational fluid dynamics (CFD) models. This work involves the critical task of assessing safety of a research reactor upon fuel reconfiguration based on models developed in RELAP and comparing them with a commercially available 3-D CFD program. The TRIGA Mark-II reactor, designed by General Atomics and located at Kansas State University, is a class of small pool type inherently safe research reactor licensed to operate at steady state power of up to 1.25 MW. It has a cylindrical core measuring 0.45 meters diametrically and 0.38 meters axially positioned in a tank measuring 1.98 meters diametrically and 6.25 meters axially. It has uranium zirconium hydride (UZrH) fuel rods housed in stainless steel cladding material arranged in five concentric rings (B,C,D,E and F rings, in that order, moving outwards from the center). TRIGA fuel is nominally 20% enriched, but the reactivity of the fuel can be changed by using burnable poisons (not used at KSU), or by varying the total weight percent of uranium in the UZrH fuel meat. The TRIGA reactor is designed to be an inherently safe reactor and is designed to be cooled by natural convection. Thus it is of paramount importance to avoid the film boiling regime; failing to do so will subject the fuel to severe conditions, possibly resulting in its failure due to fuel/clad interactions. A high DNBR ratio is a primary consideration in the reactor core design and thus any modification in the core should ensure that this criteria is always met. In order to fully utilize the capabilities of KSU TRIGA reactor facility, it should be operated at its full capacity, i.e. 1.25 MW, which requires increasing the fuel loading in some of the E- and F-ring elements from 8.5% U (nominal) to 12.0% U (nominal). Only four elements are to be switched to 12% loading, causing local power peaking in these elements. The degree of power peaking to be expected in these 12%-loaded fuel elements was calculated based on a detailed MCNP (Monte Carlo N-Particle code) model of the reactor core. Some preliminary results of the calculations are presented in this paper based on changes in peaking factors and power levels. To predict reactor thermal behavior, axial changes in the peaking factors obtained from MCNP models were used to calculate volumetric energy density functions for a single channel one dimensional RELAP model and a three dimensional COMSOL model of the TRIGA MARK-II reactor. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Refining the phylum Chlorobi by resolving the phylogeny and metabolic potential of the representative of a deeply branching, uncultivated lineage

Recent studies have expanded the phylum Chlorobi, demonstrating that the green sulfur bacteria (GSB), the original cultured representatives of the phylum, are a part of a larger lineage whose members have more diverse metabolic capabilities that overlap with members of the phylum Bacteroidetes. The 16S rRNA gene of an uncultivated clone, OPB56, distantly related to the phyla Chlorobi and Bacteroidetes, was recovered from Obsidian Pool in Yellowstone National Park; however, the detailed phylogeny and function of OPB56 and related clones have remained unknown. Culturing of thermophilic bacterial consortia from compost by adaptation to grow on ionic-liquid pretreated switchgrass provided a consortium in which one of the most abundant members, NICIL-2, clustered with OPB56-related clones. Phylogenetic analysis using the full-length 16S rRNA gene from NICIL-2 demonstrated that it was part of a monophyletic clade, referred to as OPB56, distinct from the Bacteroidetes and Chlorobi. A near complete draft genome ( > 95% complete) was recovered from metagenomic data from the culture adapted to grow on ionic-liquid pretreated switchgrass using an automated binning algorithm, and this genome was used for marker gene-based phylogenetic analysis and metabolic reconstruction. Six additional genomes related to NICIL-2 were reconstructed from metagenomic data sets obtained from thermal springs at Yellowstone National Park and Nevada Great Boiling Spring. In contrast to the 16S rRNA gene phylogenetic analysis, protein phylogenetic analysis was most consistent with the clustering of the Chlorobea, Ignavibacteria and OPB56 into a single phylum level clade. Metabolic reconstruction of NICIL-2 demonstrated a close linkage with the class Ignavibacteria and the family Rhodothermaceae, a deeply branching Bacteroidetes lineage. The combined phylogenetic and functional analysis of the NICIL-2 genome has refined the membership in the phylum Chlorobi and emphasized the close evolutionary and metabolic relationship between the phyla Chlorobi and the Bacteroidetes.

59 BASIC BIOLOGICAL SCIENCES↗

Sensitivity and uncertainty analysis for a combined depletion and criticality calculation chain of a BWR FA

This paper examines the prerequisites and boundary conditions for extending burnup credit from pressurized water reactors to boiling water reactors with validated depletion codes by performing uncertainty and sensitivity analyses on a modern boiling water reactor fuel assembly design. We developed a computational chain consisting of an axial boiling water reactor axial irradiation model, followed by a series of depletion calculations and a three-dimensional criticality calculation. The irradiation model puts into relation the profiles of power, burnup and moderator density of the fuel assembly at 24 axial locations. In a simplified fashion it also includes the insertion of control blades. The depletion calculations of the fuel assembly were performed in axial slices with the 2D-depletion code HELIOS 1.12. The criticality calculations were done in 3D-geometry with KENO-Va from the SCALE 6.2.1 package, in which several fuel assemblies are placed into a generic transport cask. For the uncertainty and sensitivity analyses a Monte Carlo sampling based approach is used applying the GRS tool SUnCISTT. We performed several generic investigations testing the capabilities and the limitations of the whole computational chain. The impact of variations of the irradiation model on the resulting reactivity of the fuel assemblies inside a transport cask or storage pool was investigated using an uncertainty and sensitivity analysis on the whole computational chain. Geometrical uncertainties were also included in the evaluation and a parameter study on the use of control blades during irradiation was performed. The goal was to develop the procedures and tools to be able to obtain quantitative uncertainty data which can be used in the future to derive conservative irradiation profiles without unnecessary excess reactivity margins. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Steady-State Thermal-Hydraulics Analyses for the Conversion of the BR2 Reactor to LEU

BR2 is a research reactor used for radioisotope production and materials testing. It’s a tank-in-pool type reactor cooled by light water and moderated by beryllium and light water. The reactor core consists of a beryllium moderator forming a matrix of 79 hexagonal prisms in a hyperboloid configuration; each having a central bore that can contain a variety of different components such as a fuel assembly, a control or regulating rod, an experimental device, or a beryllium or aluminum plug. Based on a series of tests, the BR2 operation is currently limited to a maximum allowable heat flux of 470 W/cm 2 to ensure fuel plate integrity during steady-state operation and after a loss-of-flow/loss-of-pressure accident. A feasibility study for the conversion of the BR2 reactor from highly-enriched uranium (HEU) to low-enriched uranium (LEU) fuel was previously performed to verify it can operate safely at the same maximum nominal steady-state heat flux. An assessment was also performed to quantify the heat fluxes at which the onset of flow instability and critical heat flux occur for each fuel type. This document updates and expands these results for the current representative core configuration (assuming a fresh beryllium matrix) by evaluating the onset of nucleate boiling (ONB), onset of fully developed nucleate boiling (FDNB), onset of flow instability (OFI) and critical heat flux (CHF).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The oxidation of a gasoline surrogate in the negative temperature coefficient region

This experimental study investigated the preignition reactivity behavior of a gasoline surrogate in a pressurized flow reactor over the low and intermediate temperature regime (600-800 K) at elevated pressure (8 atm). The surrogate mixture, a volumetric blend of 4.6% 1-pentene, 31.8% toluene, 14.0% n-heptane, and 49.6% 2,2,4-trimethyl-pentane (iso-octane), was shown to reproduce the low and intermediate temperature reactivity of full boiling range fuels in a previous study. Each of the surrogate components were examined individually to identify the major intermediate species in order to improve existing kinetic models, where appropriate, and to provide a basis for examining constituent interactions in the surrogate mixture. n-Heptane and 1-pentene started reacting at 630 K and 640 K, respectively, and both fuels exhibited a strong negative temperature coefficient (NTC) behavior starting at 700 and 710 K, respectively. Iso-octane showed a small level of reactivity at 630 K and a weak NTC behavior starting at 665 K. Neat toluene was unreactive at these temperatures. The surrogate started reacting at 630 K and exhibited a strong NTC behavior starting at 693 K. The extent of fuel consumption varied for each of the surrogate constituents and was related to their general autoignition behavior. Most of the intermediates identified during the surrogate oxidation were species observed during the oxidation of the neat constituents; however, the surrogate mixture did exhibit a significant increase in intermediates associated with iso-octane oxidation, but not from n-heptane. While neat toluene was unreactive at these temperatures, in the mixture it reacted with the radical pool generated by the other surrogate components, forming benzaldehyde, benzene, phenol, and ethyl-benzene. The observed n-heptane, iso-octane, and surrogate oxidation behavior was compared to predictions using existing kinetic models. The n-heptane model reasonably predicted the disappearance of the fuel, but overpredicted the formation of several of the smaller intermediates. The iso-octane model significantly overpredicted the reaction of the fuel and formation of the intermediates. The 1-pentene model reasonably predicted the fuel consumption, but underestimated the importance of radical addition to the double bond. The results of this study provide a critical experimental foundation for the investigation of surrogate mixtures and for validation of kinetic models. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RELAP-7 Simulation Resolving an SBO Scenario on a Simplified Geometry of a BWR

The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). RELAP-7 will become the main reactor systems toolkit for the Risk-Informed Safety Margin Characterization Pathway of the Light Water Reactor Sustainability Program and the next generation tool in the RELAP reactor safety/systems analysis application series (i.e., the replacement for RELAP5). The code is being developed based on Idaho National Laboratory’s modern scientific software development framework – MOOSE (the Multi-Physics Object-Oriented Simulation Environment). During Fiscal Year 2013, a number of physical components with two-phase flow capability have been developed to support the simplified boiling water reactor (BWR) station blackout analyses. The case selected for demonstration calculation is built from the specifications documented in an Organization for Economic Cooperation and Development benchmark problem for BWR turbine trip analysis. The reference design for the benchmark problem was from the Peach Bottom-2 nuclear station, which is a General Electric BWR-4 design. The demonstration case includes the major components for the primary system of a BWR, as well as the safety system components for reactor core isolation cooling (RCIC) and the wet well of a BWR containment. The case was initially run to steady-state with RELAP-7. The station blackout transient simulations were subsequently initiated by using the INL-developed RAVEN code. Two scenarios for the station blackout simulations have been considered. Scenario I represents an extreme station blackout accident with no safety injection functioning. The reactor core could experience dry out fairly quickly with this scenario. Scenario II represents a more probable station blackout accident progression with the RCIC system functioning. In this scenario, the RCIC system is fully coupled with the reactor primary system and the safety injection to provide makeup cooling water to the reactor core from the suppression pool is dynamically simulated. With the RCIC system functioning, the core dry out is significantly postponed when compared to the results from Scenario I. This fully coupled RCIC system simulation capability represents the first-of-a-kind simulation capability. Sensitivity studies have also been carried out to study the effect of RCIC control strategy with varying core makeup cooling water mass flow rates. The next stage of development will be to demonstrate more refined BWR station blackout analyses with more realistic geometries, to be reported in the next demonstration simulation report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluating a Historical Airborne Release Test with Modern Modeling Methods

Safety analysts throughout the U.S. Department of Energy (DOE) complex rely on the data provided in the DOE Handbook, DOE-HDBK-3010, to determine source terms that may be incorporated into the document safety analyses. Most often, analysts simply take the bounding values due to time constraints or simply to bound calculations. This is a safe approach that helps avoid regulatory critique; however, it may not provide results that are meaningful or relevant to the conditions being evaluated. The derivation of the data, such as airborne release fractions (ARFs) and respirable fractions (RFs) in the Handbook often depend on very limited table-top and bench/laboratory experiments, as well as engineering judgment which may not be well substantiated, and may not be representative of the actual situation. One historical dataset included a test where a solid contaminant was sprinkled over a liquid gasoline pool and set on fire (also referred to as Mishima and Schwendiman's test later in this paper). The airborne release was measured over the duration of the burn, but then collected separately for a time after the burning was completed. It can be assumed that the collected contaminant in the latter period corresponds to re-suspended particles, whereas the earlier period collected contaminant includes a combination of directly released as well as early released re-suspended particles. This scenario was recently modeled using SIERRA/Fuego as part of a parametric sensitivity study, however there were some shortcomings of the analysis methods. First, the code at the time lacked a multi-component particle evaporation model, which is necessary to capture the particle size effect of liquid/solid particles that can dynamically evaporate the liquid component. Second, a particle sticking and resuspension model did not exist at the time of the study. Recent model implementation now permits the study be repeated with the improved physical models. In the earlier work, four potential mechanisms were considered to potentially contribute to the release of the particles. These were: 1. Evaporation Induced Entrainment (EIE); 2. Surface Agitation by Wind; 3. Surface Agitation by Boiling; 4. Residue Entrainment (Resuspension). The sensitivity study evaluated mechanism 1 and 3 in the above list. Parameters varied were selected to be a reflection of a practical range of test conditions. The varied parameters included the boiling duration, fuel height, injected mass, particle size, turbulence intensity, and initial particle height. The boiling duration was the most significant parameter. The most significant mechanism was no.3, Surface Agitation by Boiling. This paper reports the implementation of the new multi-component evaporation model and its effect on the findings from the previous effort. The Mishima and Schwendiman test was re-modeled with the new evaporation model, and the results of the re-evaluation are presented. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Regulatory perspective of boiling water reactor peak reactivity credit in spent fuel storage and transportation - 14592

The U.S. Nuclear Regulatory Commission (NRC) performs reviews of applications for spent nuclear fuel transportation packages and storage casks to ensure pertinent safety regulations are met. Among other acceptance criteria, these regulations require that the package be subcritical under a variety of normal, off-normal and accident conditions. Currently, all spent nuclear fuel transportation packages and storage casks assume fresh fuel (i.e., the fuel is unirradiated) in their criticality safety analyses for boiling water reactor (BWR) fuels. Reviews using this conservative assumption are less complex. The fresh fuel assumption for BWR fuel does not allow the presence of gadolinium (often called the 'fresh fuel no-Gad' assumption), an integral burnable absorber present in nearly all BWR fuel assemblies. More recently, applicants began requesting credit for the reactivity reduction due to depletion. This credit is commonly referred to as 'burnup credit' (BUC). As of today, NRC recommends that only analyses for Pressurized Water Reactor (PWR) spent fuel implement BUC. This is due to the fact there is limited directly applicable data available to benchmark codes for depletion and reactivity calculations for BWR BUC analyses, and determining the most reactive irradiation conditions is much less straightforward than for PWR BUC analyses. Similar to what was done for PWR BUC, the NRC staff and its contractors have begun identifying and prioritizing significant technical issues so that a technical basis for the allowance of BWR BUC can be developed. BWR fuel exhibits a peak in reactivity where initial gadolinium is depleted. Crediting burnup at this point is generally referred to as using a 'peak reactivity method'. This is a conservative approach and a method routinely used in BWR spent fuel pool criticality analyses. NRC is implementing a two-phased approach in investigating BWR BUC. Phase 1 investigates peak reactivity credit and Phase 2 evaluates BUC at a typical discharge exposure. This paper discusses peak reactivity credit and its history in regulatory analyses, challenges the NRC expects in reviewing an application requesting peak BWR reactivity credit for a spent fuel transportation package or storage cask, the work that is being performed by NRC contractors to address these challenges, and future work on peak reactivity credit and full BWR BUC. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗