Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Classifying and monitoring water quality by use of satellite imagery

A technique is developed to eliminate the atmosphere and surface noise effects on Landsat signals of water bodies by manipulating the total signal from Landsat in such a way that only the volume reflectance is left as a residual. With the Landsat signal from a lake and the known volume reflectance for its clear water it is possible to eliminate the surface and atmospheric effects and have residual signals that are indicative only of the type and concentration of the material in other lakes. Laboratory values are more precise than field values because in the field one must contend with indirect skylight and wave action which can be removed in the laboratory. The volume reflectance of distilled water or a very clear lake approaching distilled water was determined in the laboratory by the use of the Bendix radiant power measuring instrument. The Bendix multispectral data analysis system provided a color categorized image of several hundred lakes in a Wisconsin area. These lakes were categorized for tannin and nontannin waters and for the degrees of algae, silt, weeds, and bottom effects present.

Scherz, J. P.↗

Electric vehicle power train instrumentation: Some constraints and considerations

The application of pulse modulation control (choppers) to dc motors creates unique instrumentation problems. In particular, the high harmonic components contained in the current waveforms require frequency response accommodations not normally considered in dc instrumentation. In addition to current sensing, accurate power measurement requires not only adequate frequency response but must also address phase errors caused by the finite bandwidths and component characteristics involved. The implications of these problems are assessed.

Triner, J. E.↗

A 30-cm mercury ion thruster performance with a 1 kW capacitor-diode voltage multiplier beam supply

A 1 kW solar array and capacitor-diode voltage multiplier converter (S/A-CDVM) was successfully integrated with a 30 cm diameter mercury ion thruster system to provide ion beam power. Measurements were made to compare steady state and transient response performance of a conventional bridge converter with the S/A-CDVM converter used for the ion beam supply. The ability to recover from screen to accelerator arcs and promptly re-establish stable thruster performance was demonstrated. Solar array transient response to thruster arcing was measured.

Terdan, F. F.↗

DOE/NASA Mod-0A wind turbine performance

Design and operation of a large wind turbine at Clayton, New Mexico is reported. This is the first of three identical 200 kW wind turbines to be operated on electric utility networks. A comparison between its predicted and measured power versus wind speed performance is presented.

Richards, T. R.↗

Electric vehicle power train instrumentation - Some constraints and considerations

The application of pulse modulation control (choppers) to dc motors creates unique instrumentation problems. In particular, the high-harmonic components contained in the current waveforms require frequency-response accommodations not normally considered in dc instrumentation. In addition to current sensing, accurate power measurement not only requires adequate frequency response but also must address phase errors caused by the finite bandwidths and component characteristics involved. This paper discusses the implications of these problems and reports on the degree to which they have been solved at Lewis Research Center.

Triner, J. E.↗

30-cm mercury ion thruster performance with a 1 kW capacitor-diode voltage multiplier beam supply

A 1 kW Solar Array and Capacitor-Diode Voltage Multiplier Converter (S/A-CDVM) has been successfully integrated with a 30 cm-diameter mercury ion thruster system to provide ion beam power. Measurements were made to compare steady state and transient response performance of a conventional bridge converter with the S/A-CDVM converter used for the ion beam supply. The ability to recover from screen to accelerator arcs and promptly re-establish stable thruster performance was demonstrated. Solar array transient response to thruster arcing was also measured.

Terdan, F. F.↗

Solar-heated bank-Marks Mississippi

Report describes air solar-energy collectors which supply 60 percent of space heating load for full-service bank. Contemporary structure supports 468 square feet of flat-plate arrays, and features onsite temperature and power measurement readouts. Air-flow collectors minimize problems experienced with conventional liquid solar equipment and eliminate need for heat exchanger for space heating.

Source record↗

Solar heating system at Quitman County Bank, Marks, Mississippi

Information on the Solar Energy Heating System installed in a single story wood frame, cedar exterior, sloped roof building is presented. The system has on-site temperature and power measurements readouts. The 468 square feet of Solaron air flat plate collectors provide for 2,000 square feet of space heating, an estimated 60 percent of the heating load. Solar heated air is distributed to the 235 cubic foot rock storage box or to the load (space heating) by a 960 cubic feet per minute air handler unit. A 7.5 ton Carrier air-to-air heat pump with 15 kilowatts of electric booster strips serve as a back-up (auxiliary) to the solar system. Motorized dampers control the direction of airflow and back draft dampers prevent thermal siphoning of conditioned air.

Source record↗

Semiconductor technology program. Progress briefs

The current status of NBS work on measurement technology for semiconductor materials, process control, and devices is reported. Results of both in-house and contract research are covered. Highlighted activities include modeling of diffusion processes, analysis of model spreading resistance data, and studies of resonance ionization spectroscopy, resistivity-dopant density relationships in p-type silicon, deep level measurements, photoresist sensitometry, random fault measurements, power MOSFET thermal characteristics, power transistor switching characteristics, and gross leak testing. New and selected on-going projects are described. Compilations of recent publications and publications in press are included.

Bullis, W. M.↗

Polymer Bonding of Optical Fibers

Optical waveguies coupled through their sides. In fiber etching process bonded length for coupling determined by observing optical output powers in two fibers. Surface tension of etchant remaining between two fibes holds then in contact when raised from solution for power measurement. When fibers reimmersed, they separate allowing free access by etchant.

Goss, W.↗

Mitigation of pulsed RFI via automatic gain control

Three automatic gain control (AGC) strategies and their potential capabilities for mitigation of pulsed radio frequency interference (RFI) over a coded, nonlinear channel are examined. The first updates the AGC control voltage once each symbol interval in accordance with a prespecified criterion. The second implementation is designed to first detect high level RFI and then appropriately update its gain. The final implementation is a wideband device which updates its gain once each symbol interval by reducing the gain in direct proportion to a suitable power measurement. Computed results treat pulsed noise and pulsed CW RFI and compare performances in terms of bit error rate (BER) at the output of a Viterbi decoder.

Chang, R. W.-S.↗

Surface fluctuation spectroscopy - A novel technique for characterizing liquid interfaces

Surface fluctuation spectroscopy is a dynamic light scattering technique which involves the detection of thermal fluctuations (capillary waves) that cover every liquid interface. The advantages of this technique over conventional mechanical methods are discussed. The signal resolution and precision are improved by using a grating heterodyne technique coupled with a digital correlator. Detailed calculations showed that, for the measured power spectrum (the Fourier transform of the correlation function) to take the Lorentzian shape, it is necessary that certain optical conditions be met. These conditions are demonstrated with experimental data collected for ethanol at the ambient temperature as a function of the wave number. Once the optical parameters are adjusted correctly, the experimental results show excellent agreement with the literature values. It is also demonstrated that, using microcomputer technology, the entire system can be automated.

Shih, L. B.↗

Goldstone field test activities: Sky survey

The goals are to conduct a research and development program aimed at determining the most effective way to do SETI within the constraints of current technology and estimated budgets. The general search strategy adopted is that which is recommended by the SETI Science Working Group. The strategy for an all sky survey for SETI was further developed over the last year. Scan patterns, scan rates, and signal detection algorithms were developed. Spectral power measurement instrumentation was tested at the Venus Station of the Goldstone Deep Space Communication Complex. A specially designed radio frequency interference (RFI) measurement system was built and installed at the Venus Station. A data base management system for storage and retrieval of the RFI data was partially implemented on a VAX 750 computer at the Jet Propulsion Laboratory.

Gulkis, S.↗

Measurements of antenna polar diagrams and efficiencies using a phase-switched interferometer

It is desirable to know antenna polar patterns and efficiencies accurately. In the past, calibration measurements have been made using balloons and aircraft and more recently satellites. These techniques are usually very expensive. It is shown that under certain circumstances it is possible to use a simpler and inexpensive technique by connecting together the antenna under test with another antenna to form a phase switched interferometer as first described by Ryle (1952). The technique does require a suitable radio source which gives measurable powers when using small antennas and since dipoles have broad patterns, radio sources with similar right ascensions but different declinations to the primary source can be a problem. These problems can partly be overcome by filtering the interference pattern.

Vincent, R. A.↗

Thermal evaluation method for Klystron RF power

The feasibility of adding instrumentation to the cooling system of a microwave transmitter for use as a calorimetric power measurement calibration is examined. It considers the accuracy of the basic measurements as well as heat sources and losses not measured. Experimental results are presented in support of the theory.

Conroy, B. L.↗

Rayleigh lidar observations of gravity wave activity in the stratosphere and lower mesosphere

Forty-two monochromatic gravity wave events were observed in the 25 to 55 km altitude region during 16 nights of Rayleigh lidar measurements at Poker Flat, Alaska and Urbana, Illinois. The measured wave parameters were compared to previous radar and lidar measurements of gravity wave activity. Vertical wavelengths, lambda(z), between 2 and 11.5 km with vertical phase velocities, c(z), between 0.1 and 1 m/s were observed. Measured values of lambda(z) and c(z) were used to infer observed wave periods, T(ob), between 50 and 1000 minutes and horizontal wavelengths, lambda(x), from 25 to 2000 km. Dominant wave activity was found at vertical wavelengths between 2 to 4 km and 7 to 10 km. No seasonal variations were evident in the observed wave parameters. Vertical and horizontal wavelengths showed a clear tendency to increase with T(ob), which is consistent with recent sodium lidar studies of monochromatic wave events near the mesopause. Measured power law relationships between the wave parameters were lambda(z) varies as T(ob) sup 0.96, lambda(x) varies as T(ob) sup 1.8, and c(z) varies as T(ob) sup -0.85. The kinetic energy calculated for the monochromatic wave events varied as k(z) sup -2, k(x) sup -1, and f(ob) sup -1.7. The atmospheric scale heights calculated for each observation date range from 6.5 to 7.6 km with a mean value of 7 km. The increase of rms wind perturbations with altitude indicated an amplitude growth length of 20.9 km. The altitude profile of kinetic energy density decreased with height, suggesting that waves in this altitude region were subject to dissipation or saturation effects.

Miller, M. S.↗

Radar RFI at Goldstone DSS 12 and DSS 16

Radio frequency interference (RFI) from the DSS 14 Goldstone Solar System Radar (GSSR) was investigated at DSS 12 and DSS 16 with the goal of assisting in the choice of the location of future DSN antennas. Total power measurements at both locations were made at the S-band carrier frequency of 2320 MHz. X-band measurements at the carrier frequency of 8495 MHz could not be made. Exciter-chain output spectrum and klystron output spectrum measurements were made at S- and X-bands using a probable worst-case modulation of the radar signal (short pseudorandom number (PN) code length and short pulse length). Based on these measurements, it is estimated that RFI levels in the DSN receiving bands at both sites (above 10-deg elevation) would be below -192 dBm for a 1-Hz bandwidth

Slobin, S. D.↗