Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

All Kitted Out

The Hydropower Knowledge Sharing and Succession Planning Toolkit, created by the National Renewable Energy Laboratory (NREL) in collaboration with the U.S. Department of Energy’s Water Power Technologies Office (WPTO), can help your organization effectively plan for workforce changes and share knowledge across employees. By proactively implementing knowledge sharing and succession planning strategies, hydropower organizations can safeguard institutional knowledge, enhance workforce resilience, and ensure long-term operational stability in an evolving industry landscape.

13 HYDRO ENERGY↗

Low-Energy Radon Backgrounds from Electrode Grids in Dual-Phase Xenon TPCs

The dual-phase xenon time projection chamber (TPC) is a powerful technology to detect rare interactions such as scatters of dark matter particles on nuclei. In particular, the built-in gain of ionization signals in a dual-phase TPC makes it sensitive to events in the few-electron regime, as expected from low-mass dark matter interactions. The pursuit of this low-energy sensitivity through ionization-only signal detection has so far been hindered by excessive electron backgrounds observed across experiments. Much of this background is attributed to the plate-out of $^{222}$Rn decay chain isotopes on the high voltage electrode grid surfaces that span the full cross section of the TPC. This work presents a first-principle model constructed for this background, the predictions of which are consistent with data from the LZ and LUX experiments. We then discuss mitigation strategies of this background in future dual-phase TPCs and the possibility of applying this grid background model to ionization-only dark matter searches.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]↗

Power Sector Transformation Pathways: Exploring Objectives, Factors, and Technology Innovations to Inform Power Sector Pathway Decisions

The power and heating sectors are responsible for around 30% of global CO2 emissions and this share is likely to grow as countries move towards electrification of the transportation and building sectors. Therefore, enabling forward-thinking, long term strategies in the power sector is a crucial area for international collaboration and support. The rapid transition of power systems toward modern, low-carbon pathways and technologies will be necessary to meet key climate goals while also enabling other critical objectives such as economic development, energy access, and energy system resiliency, among others. Many developed and developing countries are well-poised to champion power sector transformation (PST), however, further support is needed to identify pathways and implement critical near and long-term actions. To address this need, the Low Emission Development Strategies Global Partnership (LEDS GP) together with an expert team including Agora Energiewende, Energy Innovation, European Climate Foundation, Fraunhofer Institute for Systems and Innovation Research , Prayas Energy Group and LEDS Latin America and Caribbean Platform, developed a framework identifying four key pathways that can be integrated and combined to support low-carbon PST. These four pathways are: (1) Distributed Energy Resource Revolution, (2) Bulk Power Transformation, (3) Transmission and Distribution Interactivity, and (4) Distributed Transactional Future. To support exploration of pathways, this study examines PST objectives and factors that may lead countries or jurisdictions to place a greater relative emphasis on certain pathways as well as a framework and complementary tool for considering the emphasis in a hands on manner. The report provides case studies on application of the approach to bring life to the topic. The case studies include Haiti, Kenya, Mexico, Southeast Asia, and the European Union, among others. The report also presents actions to-be-taken in the near-, medium- and long-term to support the realization of pathways and long-term transformation of the power sector. The report, together with a complementary spreadsheet tool developed under the effort, can be used to enable stakeholder engagement and visioning for the power sector over the long-term, taking into account key factors and potential innovations. It can also be used to understand and inform relevant analysis tools and models based on which pathways are emphasized, and to identify key actions in the near- and medium-term to avoid lock-in of carbon-intensive technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Quantitative Risk Analysis of High Safety Significant Safety-related Digital Instrumentation and Control Systems in Nuclear Power Plants using IRADIC Technology

This report documents the activities performed by Idaho National Laboratory (INL) during fiscal year (FY) 2021 for the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program, Risk Informed Systems Analysis (RISA) Pathway, digital instrumentation and control (DI&C) Risk Assessment project. In FY-2019, the RISA Pathway initiated a project to develop a risk assessment strategy for delivering a strong technical basis to support effective, licensable, and secure DI&C technologies for digital upgrades/designs. An integrated risk assessment technology for the DI&C systems (IRADIC technology) was proposed for this strategy, which aims to (1) provide a best-estimate risk-informed capability to quantitatively and accurately estimate the safety margin obtained from plant modernization, especially for the High Safety Significant Safety-related (HSSSR) DI&C systems, (2) develop an advanced risk assessment technology to support transition from analog to DI&C technologies for nuclear industry, (3) assure the long-term safety and reliability of vital HSSSR DI&C systems, (4) reduce uncertainty in costs and support integration of DI&C systems in the plant. To achieve these technical goals and deal with the expensive licensing justifications from regulatory insights, the IRADIC technology is instructive for nuclear vendors and utilities to effectively lower the costs associated with digital compliance and speed industry advances by: (1) defining an integrated risk-informed analysis process for DI&C upgrade, including hazard analysis, reliability analysis, and consequence analysis, (2) applying systematic and risk-informed tools to address common cause failures (CCFs) and quantify responding failure probabilities for DI&C technologies, particularly software CCFs, (3) evaluating the impact of digital failures at the individual level, system level, and plant level, (4) providing insights and suggestions on designs to manage the risks; thus, to support the development, licensing, and deployment of advanced DI&C technologies on nuclear power plant (NPPs). In this report, an approach for performing software CCF analysis, given limited data, is developed and demonstrated using a case study of a highly redundant digital reactor trip system. Consequence analysis is also performed based on different accident scenarios. Results indicate that plant modernization including the improvement of HSSSR DI&C systems will make great benefits to plant safety by providing more safety margins to accident management. In addition, a novel approach is proposed in this report for the quantification of software hazards when sufficient operational and testing data available. The method incorporates software development quality as well as strong analysis techniques to identify and link software defects to potential failure modes. The approach includes both semantic and test-based analysis to detect failures that can exist in different stages of the software development life cycle. This method is applied to an advanced human system interface relevant to reactor trip safety developed from the APR 1400 design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

Power over Ethernet (PoE) technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras. They are systems that are familiar to and managed by on-site IT staff. As low voltage DC-power capabilities have increased with the advancement of IT network switches within offices, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. The connection of PoE devices to network switches offers the opportunity for energy monitoring and management to be performed through IT network management software. Data and results from technology validations of PoE equipment remain very limited. This lack of information hinders expansion of PoE as an energy management strategy as its benefits and challenges have been insufficiently quantified in real-world scenarios. This final report presents the findings of a DOE/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at six sites: two offices, three schools, and a hotel. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where not typically available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Draft Methodology for Cybersecurity Analysis for Adoption of Wireless Technology in Nuclear Power Plants

The report is delivered as DOE-NE Cybersecurity Program Milestone M2CT-22IN1104014-Industry cybersecurity guidance adoption status. The milestone is specifically to document the process and the status of the efforts towards developing guidance in support of industry’s adoption of wireless communication technologies. To transform the operation of nuclear power plants, including domestic light-water reactors, advanced reactors, microreactors, and fission battery, for grid and non-grid applications, secure and resilient wireless capabilities are required. In addition, to realize new operational concepts such as autonomous operation and remote monitoring, advanced sensor, and instrumentation, wireless technology is essential. However, industry implementation is low, and there is no technical basis for how to understand and address potential risks for wireless communications for critical plant functions. A methodology with a technical basis for implementing secure wireless communication is crucial. This wireless adoption methodology is intended to assist a licensee in identifying an appropriate technological approach for securing wireless communications in nuclear power plant. However, this methodology does not provide guidance for addressing wireless design criteria or for addressing all the cybersecurity commitments in licensees’ cybersecurity plans (CSPs) including addressing security impact analysis that a licensee must perform before an update to a Critical Digital Asset (CDA). This methodology guides a licensee through a process of evaluating a proposed wireless implementation and drafting a plant change notification for an example use case. The example is a generic/nonproprietary version of the first test case of the methodology, which, if successfully implemented, is part of the consideration for protecting other functions’ use of wireless in a cybersecure manner.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Examining the Use of the Technology Acceptance Model for Adoption of Advanced Digital Technologies in Nuclear Power Plants

The United States nuclear industry is being economically challenged and needs wide-scale adoption of enabling technology like advanced automation to remain viable. To enable wide-scale adoption of advanced technology, addressing the human-technology integration challenges and factors that influence technology acceptance (i.e., ‘buy in’) is pertinent. This work examines the Technology Acceptance Model as a framework for characterizing the factors influencing technology adoption in the nuclear industry. An outcome of this work is to support the development of future tools such as a technology acceptance survey that can be used to assess technology acceptance throughout the lifespan of a modernization program to provide a systematic way of ensuring stakeholder and operations ‘buy in.’

99 GENERAL AND MISCELLANEOUS↗

Dry cooler contribution to LCOE in a sCO 2 power cycle for CSP

In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO 2 (sCO 2 ) based power cycles. Here, these cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700 °C.

14 SOLAR ENERGY↗

Criteria for Determining the Safety of Wireless Technologies at Nuclear Power Plants

This report provides an initial discussion of the potential impact to safety-related/important-to-safety (SR/ITS) systems by the possible expanded use of wireless technologies. One aspect of this discussion is focused on a review of Regulatory Guide (RG) 1.180 Rev. 2 to determine whether any revisions are necessary to reflect the current state of practice in evaluating and protecting instrumentation and control (I&C) systems and components from electromagnetic interference (EMI) or radiofrequency interference (RFI) on safety and nonsafety I&C. Electromagnetic compatibility (EMC) is the ability of a device or system to function satisfactorily in its electromagnetic (EM) environment, which is achieved by limiting the unintentional generation, propagation, and reception of EM energy that may cause unwanted effects such as EMI. The goal of EMC is to ensure the correct operation of different types of equipment in a common EM environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Update on the Status of a Reduced Flow Test of a 10MW 700°C sCO2 Integrally Geared Compander

. In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO2 based power cycles. These cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700 degrees Celsius. This paper will summarize the current status of a US Department of Energy project to develop machinery to support a 10 MW sCO2 power cycle. The team of Southwest Research Institute® (SwRI®) and Hanwha Power Systems America, proposed to develop an integrally-geared (IG) compressor-expander (compander) for use in a nominal 10 MW-scale concentrated solar power (CSP) supercritical carbon dioxide (sCO2) plant application. This integrally-geared compander (IGC) comprises multiple pinion shafts interconnected on a single bull gear to create a compact package, and utilizes a low-cost, low-speed driver. In addition, the integrally geared architecture allows each pinion to operate at different rotational speeds to optimize performance and easily allow for inter-stage cooling and turbine re-heat to further enhance both stage and cycle efficiency. The close integration of all turbomachinery elements into a single integrally-geared (IG) machine creates a design that lends itself to power block modularization, which makes it suitable for waste heat recovery, fossil fuel power plants, and especially CSP applications. As part of the commercialization of this technology, it is necessary to reduce risk by validation testing of key components. In the current work, the focus is developing a test loop to enable safe testing of the main compressor stage across a wide range of operating conditions, and to validate the mechanical integrity of the turbine at full pressure, temperature, and speed. Developing a test loop for sCO2 requires balancing a number of design alternatives that impact cost, lead time, safety, and performance. The current work discusses the design process for the reduced flow test loop for the compander, and supporting documentation supporting the viability of the test loop

wilkes, jason↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

AN UPDATE ON THE STATUS OF A REDUCED FLOW TEST OF A 10MW 700⁰C SCO2 INTEGRALLY GEARED COMPANDER

In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO2 based power cycles. These cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700℃. This paper will summarize the current status of a US Department of Energy project to develop machinery to support a 10 MW sCO2 power cycle. The team of Southwest Research Institute® (SwRI®) and Hanwha Power Systems America, proposed to develop an integrally-geared (IG) compressor-expander (compander) for use in a nominal 10 MW-scale CSP supercritical carbon dioxide (sCO2) plant application. This integrally-geared compander (IGC) comprises multiple pinion shafts interconnected on a single bull gear to create a compact package, and utilizes a low-cost, low-speed driver. In addition, the integrally-geared architecture allows each pinion to operate at different rotational speeds to optimize performance and easily allow for inter-stage cooling and turbine re-heat to further enhance both stage and cycle efficiency. The close integration of all turbomachinery elements into a single integrally-geared (IG) machine creates a design that lends itself to power block modularization, which makes it suitable for waste heat recovery, fossil fuel power plants, and especially CSP applications.

14 SOLAR ENERGY↗

High average power ultrafast laser technologies for driving future advanced accelerators

Large scale laser facilities are needed to advance the energy frontier in high energy physics and accelerator physics. Laser plasma accelerators are core to advanced accelerator concepts aimed at reaching TeV electron electron colliders. In these facilities, intense laser pulses drive plasmas and are used to accelerate electrons to high energies in remarkably short distances. A laser plasma accelerator could in principle reach high energies with an accelerating length that is 1000 times shorter than in conventional RF based accelerators. Notionally, laser driven particle beam energies could scale beyond state of the art conventional accelerators. LPAs have produced multi GeV electron beams in about 20 cm with relative energy spread of about 2 percent, supported by highly developed laser technology. This validates key elements of the US DOE strategy for such accelerators to enable future colliders but extending best results to date to a TeV collider will require lasers with higher average power. While the per pulse energies envisioned for laser driven colliders are achievable with current lasers, low laser repetition rates limit potential collider luminosity. Applications will require rates of kHz to tens of kHz at Joules of energy and high efficiency, and a collider would require about 100 such stages, a leap from current Hz class LPAs. This represents a challenging 1000 fold increase in laser repetition rates beyond current state of the art. Here, this whitepaper describes current research and outlook for candidate laser systems as well as the accompanying broadband and high damage threshold optics needed for driving future advanced accelerators.

47 OTHER INSTRUMENTATION↗

Three Modeling Tools Accelerate the Development of Marine Energy Technologies

Enough power flows through U.S. rivers and oceans to meet up to 60% of the country's electricity needs. But before today's early-stage marine energy technologies can harness some of that power, they need to overcome a few challenges, like a volatile ocean and high development costs. And to do that, technology developers need reliable tools to understand and overcome the challenges they face. That's why researchers at the National Renewable Energy Laboratory (NREL) have developed several open-source, validated, and customizable numerical tools for technology developers. With these tools, the marine energy community can assess their devices' potential power output, predict how their technologies might handle extreme loads (like extreme waves), and learn how changing one component might affect their device's performance. The lab's models generate highly accurate, reliable, robust data that can help marine energy devices leap from the computer screen to the ocean and, eventually, the power grid.

current energy↗

TEMPEST (Thermo-Electric Model for Powering Energy Storage Technologies)

NREL's TEMPEST model combines electrical and thermal modeling for residential-scale battery systems. The model and default parameters are based off of two common commercial residential batteries. Key inputs to the model include house load, temperature of the battery location, and the solar profile. The key output of the TEMPEST model is the battery profile and internal battery temperature. If internal battery temperature exceeds limits, a derating will occur and this will be reflected in the battery profile. In addition to thermal modeling, the TEMPEST model uses realistic operating principals that are common in today's residential batteries. Mainly, the TEMPEST model incorporates "modes" of operation that constrain battery setpoint based on house load, solar output, and state of charge. The TEMPEST model can be used to analyze the effect of battery temperature, deratings, and mode setpoints on utility network loading and customer bills.

Blonsky, Michael↗