Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Space Electronic Test Engineering

The Space Power and Propulsion Test Engineering Branch at NASA Glenn Research center has the important duty of controlling electronic test engineering services. These services include test planning and early assessment of Space projects, management and/or technical support required to safely and effectively prepare the article and facility for testing, operation of test facilities, and validation/delivery of data to customer. The Space Electronic Test Engineering Branch is assigned electronic test engineering responsibility for the GRC Space Simulation, Microgravity, Cryogenic, and Combustion Test Facilities. While working with the Space Power and Propulsion Test Engineering Branch I am working on several different assignments. My primary assignment deals with an electrical hardware unit known as Sunny Boy. Sunny Boy is a DC load Bank that is designed for solar arrays in which it is used to convert DC power form the solar arrays into AC power at 60 hertz to pump back into the electricity grid. However, there are some researchers who decided that they would like to use the Sunny Boy unit in a space simulation as a DC load bank for a space shuttle or even the International Space Station hardware. In order to do so I must create a communication link between a computer and the Sunny Boy unit so that I can preset a few of the limits (such power, set & constant voltage levels) that Sunny Boy will need to operate using the applied DC load. Apart from this assignment I am also working on a hi-tech circuit that I need to have built at a researcher s request. This is a high voltage analog to digital circuit that will be used to record data from space ion propulsion rocket booster tests. The problem that makes building this circuit so difficult is that it contains high voltage we must find a way to lower the voltage signal before the data is transferred into the computer to be read. The solution to this problem was to transport the signal using infrared light which will lower the voltage signal down low enough so that it is harmless to a computer. Along with my involvement in the Space Power and Propulsion Test Engineering Branch, I am obligated to assist all other members of the branch in their work. This will help me to strengthen and extend my knowledge of Electrical Engineering.

Chambers, Rodney D.↗

Recent Radiation Test Results for Trench Power MOSFETs

Single-event effect (SEE) radiation test results are presented for various trench-gate power MOSFETs. The heavy-ion response of the first (and only) radiation-hardened trench-gate power MOSFET is evaluated: the manufacturer SEE response curve is verified and importantly, no localized dosing effects are measured, distinguishing it from other, non-hardened trench-gate power MOSFETs. Evaluations are made of n-type commercial and both n- and p-type automotive grade trench-gate device using ions comparable to of those on the low linear energy transfer (LET) side of the iron knee of the galactic cosmic ray spectrum, to explore suitability of these parts for missions with higher risk tolerance and shorter duration, such as CubeSats. Part-to-part variability of SEE threshold suggests testing with larger sample sizes and applying more aggressive derating to avoid on-orbit failures. The n-type devices yielded expected localized dosing effects including when irradiated in an unbiased (0-V) configuration, adding to the challenge of inserting these parts into space flight missions.

Schottky Diodes↗

Develop and test fuel cell powered on-site integrated total energy systems: Phase 3: Full-scale power plant development

The development of a commercially viable and cost-effective phospheric acid fuel cell powered on-site integrated energy system (OS/IES) is described. The fuel cell offers energy efficients in the range of 35-40% of the higher heating value of available fuels in the form of electrical energy. In addition, by utilizing the thermal energy generated for heating, ventilating and air-conditioning (HVAC), a fuel cell OS/IES could provide total energy efficiencies in the neighborhood of 80%. Also, the Engelhard fuel cell OS/IES offers the important incentive of replacing imported oil with domestically produced methanol, including coal-derived methanol.

Source record↗

Performance of a thermomechanical pump

This paper presents the results of a series of thermomechanical pump tests to determine the performance of a simulated transfer system. The tests compared heater power versus transfer rates with accurate temperature, pressure, flow rate and heater power data. Test data were also compared to a computer model. The thermomechanical pump performance was found to be primarily a function of supply liquid temperature and heat input near the plug.

Mills, G. L.↗

High power, high frequency component test facility

The NASA Lewis Research Center has available a high frequency, high power laboratory facility for testing various components of aerospace and/or terrestrial power systems. This facility is described here. All of its capabilities and potential applications are detailed.

Roth, Mary Ellen↗

Tests Of A Stirling-Engine Power Converter

Report describes acceptance tests of power converter consisting of pair of opposed free-piston Stirling engines driving linear alternators. Stirling engines offer potential for extremely long life, high reliability, high efficiency at low hot-to-cold temperature ratios, and relatively low heater-head temperatures.

Dochat, George↗

The flight test program for the hydrogen powered NASP/X-30 research aircraft

The NASP/X-30 will be the first U.S. manned aircraft to be powered with hydrogen. Flight testing the X-30 powered with liquid and/or slush hydrogen along with its high speed capability will present unique challenges to the flight test community. The paper describes the overall X-30 flight research program along with some of the key technology challenges. A flight test envelope expansion concept is described along with typical mission profiles. Flight test problems unique to this class of vehicle will be outlined as well as some preliminary thoughts as to solutions to those problems. The X-30 ground operations with hydrogen must be compatible with the normal operations at the flight test site. A concept for the ground support system will be introduced.

Wierzbanowski, Theodore↗

Design and testing of a high power spacecraft thermal management system

The design and test results are presented of an ammonia hybrid capillary pumped loop thermal control system which could be used for heat acquisition and transport on future large space platforms and attached payloads, such as those associated with the NASA Space Station. The High Power Spacecraft Thermal Management System (HPSTM) can operate as either a passive, capillary pumped two phase thermal control system, or, when additional pressure head is required, as a mechanically pumped loop. Testing has shown that in the capillary mode, the HPSTM evaporators can acquire a total heat load of between 600 W and 24 kW, transported over 10 meters, at a maximum heat flux density of 4.3 W/sq cm. With the mechanical pump circulating the ammonia, a heat acquisition potential of 52 kW was demonstrated for 15 minutes without an evaporator failure. These results represent a significant improvement over the maximum transport capability previously displayed in other capillary systems. The HPSTM system still retains the proven capillary capabilities of heat load sharing and flow control between evaporator plates, rapid power cycling, and nonuniform heating in both the capillary and hybrid operating modes.

Mccabe, Michael E., Jr.↗

Phase 1 wind tunnel tests of the J-97 powered, external augmentor V/STOL model

Test results are presented for a large scale, external augmentor V/STOL model in a 40 ft by 80 ft wind tunnel. The model was powered by a GE J97 engine and featured longitudinal ejectors alongside and external to the fuselage together with an augmentor flap on the low aspect ratio, double-delta wing. A static thrust augmentation ratio of 1.60 was measured for the fuselage augmentor at a nozzle pressure ratio of 3.0 and a nozzle exhaust gas temperature of 700 C. At forward speed the model showed a strong positive lift interference due to the augmentor flap, and a marked absence of negative lift interference due to the fuselage augmentor jet system. The nose-up moment of the fuselage augmentor inlet flow was approximately cancelled by a 60 deg deflection of the augmentor flap. An assessment of the thrust and drag components to allow the prediction of transition performance of aircraft designs based on the present conceptual model was made. Lateral tests showed strong but well ordered effects of power.

Garland, D. B.↗

High-power baseline and motoring test results for the GPU-3 Stirling engine

Test results are given for the full power range of the engine with both helium and hydrogen working fluids. Comparisons are made to previous testing using an alternator and resistance load bank to absorb the engine output. Indicated power results are presented as determined by several methods. Motoring tests were run to aid in determining engine mechanical losses. Comparisons are made between the results of motoring and energy-balance methods for finding mechanical losses.

Thieme, L. G.↗

EMTP based stability analysis of space station electric power system in a test bed environment

The Space Station Freedom Electric Power System (EPS) will convert solar energy into electric energy and distribute the same using an 'all dc', Power Management and Distribution (PMAD) System. Power conditioning devices (dc to dc converters) are needed to interconnect parts of this system operating at different nominal voltage levels. Operation of such devices could generate under damped oscillations (instability) under certain conditions. Criteria for instability are examined and verified for a single device. Suggested extension of the criteria to a system operation is examined by using the EMTP model of the PMAD DC test bed. Wherever possible, data from the test bed is compared with the modeling results.

Dravid, Narayan V.↗

EMTP based stability analysis of Space Station Electric Power System in a test bed environment

The Space Station Freedom Electric Power System (EPS) will convert solar energy into electric energy and distribute the same using an 'all dc', Power Management and Distribution (PMAD) System. Power conditioning devices (dc to dc converters) are needed to interconnect parts of this system operating at different nominal voltage levels. Operation of such devices could generate under damped oscillations (instability) under certain conditions. Criteria for instability are examined and verified for a single device. Suggested extension of the criteria to a system operation is examined by using the EMTP model of the PMAD dc test bed. Wherever possible, data from the test bed is compared with the modeling results.

Dravid, Narayan V.↗

Turbofan Engine Power Extraction Demonstration Final Report

As GE Aerospace advances toward a revolutionary step change in propulsion efficiency, the integration and demonstration of new engine architectures and technology systems are essential. The NASA Turbofan Engine Power Extraction Demonstration (PEx), conducted through the Hybrid Thermally Efficient Core (HyTEC) project, aims to develop and demonstrate megawatt-class hybrid electric capability on a modern commercial turbofan engine. The hybrid electric system is critical to meeting the needs of the U.S. aviation industry for next-generational propulsion systems with greater efficiency, durability, and range. This supports energy independence and helps ensure the security and resilience of one of America's largest export industries. The PEx project specifically targets three key objectives: mechanically integrating hybrid electric capability into a commercial turbofan engine, integrating electric machine control with turbofan control for advanced power management, and de-risking performance modeling of future hybrid electric architectures. To mature these technologies to Technology Readiness Level (TRL) 6, a series of electric power system component tests and a baseline engine performance test campaign were conducted. These efforts culminated in an integrated hybrid electric turbofan test campaign demonstrating power extraction, power insertion, and power transfer between spools. Tests of the electric power system were completed at GE Aerospace’s Electrical Power Integrated Systems Center in Dayton, Ohio and engine tests were completed at Peebles Test Operation in Peebles, Ohio. Hybrid electric trade studies extended the demonstrated capability to altitude using the validated cycle model from the PEx test campaigns, allowing for comments on expanded mission benefits not demonstrated in the ground campaign. The knowledge gained from PEx also supports GE Aerospace’s Compact Core Demonstrator as part of HyTEC Phase 2 and ultimately informs the implementation of hybrid electric systems in the next generation of GE Aerospace commercial engine products. This report provides a summary of the program background, test campaigns, trade studies, and insights into the technical maturation required to support future commercial products.

Hybrid Electric↗