Camera to view southwest scene at BNF tower site from 6m height, processed into a movie
Aviation Power Supply's mobile firefighting module called Firefly II is mounted on a trailer pulled by a pickup truck. Trailer unit has two three- inch water cannons, and the pickup carries a six inch cannon. Completely self contained, module pumps 3,000 gallons of water a minute from hydrants or open bodies of water. Stream can go as far as 400 feet or can be employed in a high-loft mode to reach the tops of tall refinery towers. Compact Firefly II weighs only 2,500 pounds when fully fueled. Key component is a specially designed two stage pump. Power for the pump is generated by a gas turbine engine. Module also includes an electronic/pump controller, multiple hose connections, up to 1,500 feet of hose and fuel for four hours operation. Firefly trailer can be backed onto specially-built large fireboat.
Aviation Power Supply's mobile firefighting module called Firefly II is mounted on a trailer pulled by a pickup truck. Trailer unit has two three- inch water cannons, and the pickup carries a six inch cannon. Completely self contained, module pumps 3,000 gallons of water a minute from hydrants or open bodies of water. Stream can go as far as 400 feet or can be employed in a high-loft mode to reach the tops of tall refinery towers. Compact Firefly II weighs only 2,500 pounds when fully fueled. Key component is a specially designed two stage pump. Power for the pump is generated by a gas turbine engine. Module also includes an electronic/pump controller, multiple hose connections, up to 1,500 feet of hose and fuel for four hours operation. Firefly trailer can be backed onto specially-built large fireboat.
Observations of the solar velocity field with a diode array attached to the echelle spectrograph of a vacuum tower telescope are described which resolve the solar five-minute oscillatory motion into distinct bands of power. Previous observations are discussed which show that the solar five-minute oscillations can be resolved into frequencies having the character of nonradial p-mode eigenfrequencies of the solar envelope. The present observations confirm the observed frequencies and sharpen the previous resolution of the five-minute oscillations into ridges on the (wavenumber, frequency) plane. A comparison with earlier calculations indicates that the theoretical frequencies are in good but not perfect agreement with those observed. It is concluded that the identification of the five-minute oscillations as nonradial p-mode oscillations in the solar envelope is established beyond doubt.
Dry-cooling sub-systems for residential solar powered Rankine compression air conditioners were economically optimized and compared with the cost of a wet cooling tower. Results in terms of yearly incremental busbar cost due to the use of dry-cooling were presented for Philadelphia and Miami. With input data corresponding to local weather, energy rate and capital costs, condenser surface designs and performance, the computerized optimization program yields design specifications of the sub-system which has the lowest annual incremental cost.
There is a need for improved optical diagnostic methods for use in microgravity combustion research. Spectroscopic methods with fast time response that can provide absolute concentrations and concentration profiles of important chemical species in flames are needed to facilitate the understanding of combustion kinetics in microgravity. Although a variety of sophisticated laser-based diagnostics (such as planar laser induced fluorescence, degenerate four wave mixing and coherent Raman methods) have been applied to the study of combustion in laboratory flames, the instrumentation associated with these methods is not well suited to microgravity drop tower or space station platforms. Important attributes of diagnostic systems for such applications include compact size, low power consumption, ruggedness, and reliability. We describe a diode laser-based near-UV source designed with the constraints of microgravity research in mind. Coherent light near 420 nm is generated by frequency doubling in a nonlinear crystal. This light source is single mode with a very narrow bandwidth suitable for gas phase diagnostics, can be tuned over several 1/cm and can be wavelength modulated at up to MHz frequencies. We demonstrate the usefulness of this source for combustion diagnostics by measuring CH radical concentration profiles in an atmospheric pressure laboratory flame. The radical concentrations are measured using wavelength modulation spectroscopy (WMS) to obtain the line-of-sight integrated absorption for different paths through the flame. Laser induced fluorescence (LIF) measurements are also demonstrated with this instrument, showing the feasibility of simultaneous WMS absorption and LIF measurements with the same light source. LIF detection perpendicular to the laser beam can be used to map relative species densities along the line-of-sight while the integrated absorption available through WMS provides a mathematical constraint on the extraction of quantitative information from the LIF data. Combining absorption with LIF - especially if the measurements are made simultaneously with the same excitation beam - may allow elimination of geometrical factors and effects of intensity fluctuations (common difficulties with the analysis of LIF data) from the analysis.
High temperatures inside the plasma of a carbon arc generate strong buoyancy driven convection which has an effect on the growth and morphology of the single-walled carbon nanotubes (SWNTs). To study the effect of buoyancy on the arc process, a miniature carbon arc apparatus was designed and developed to synthesize SWNTs in a microgravity environment substantially free from buoyant convective flows. An arc reactor was operated in the 2.2- and 5.18-second drop towers at the NASA Glenn Research Center. The apparatus employed a 4 mm diameter anode and was powered by a portable battery pack capable of providing in excess of 300 amps at 30 volts to the arc for the duration of a 5-second drop. However, the principal result is that no dramatic difference in sample yield or composition was noted between normal gravity, 2.2-and 5-second long microgravity runs.
This article introduces a 4 kV/120 A solid-state dc circuit breaker (DCCB) based on discrete SiC mosfets. The DCCB is designed in a five-layer tower structure. Each layer consists of a circular main conduction branch and an attached gate driver. There are two primary benefits of the proposed DCCB. First, it reduces conduction loss with multiple devices in parallel. Second, it achieves an ultrafast response speed with SiC mosfets. Moreover, the gate drivers of the DCCB are powered by a domino inductive power transfer (IPT) system. It achieves the load-independent constant-voltage output characteristics, which means the outputs are immune to load variations. Additionally, an IPT system prototype is implemented to test the power transfer performance. At 500-kHz frequency, the total output power reaches 15.73 W, which is sufficient to power on five gate drivers, with a peak transfer efficiency of 75.4%. The IPT system is tested to power a 4 kV/120 A DCCB prototype. It validates that the DCCB is effective to turn off 120 A current within 3.5 μs.
The report details test and measurement flights to demonstrate autonomous UAV inspection of high voltage electrical transmission structures. A UAV built with commercial, off-the-shelf hardware and software, supplemented with custom sensor logging software, measured ultraviolet emissions from a test generator placed on a low-altitude substation and a medium-altitude switching tower. Since corona discharge precedes catastrophic electrical faults on high-voltage structures, detection and geolocation of ultraviolet emissions is needed to develop a UAV-based self-diagnosing power grid. Signal readings from an onboard ultraviolet sensor were validated during flight with a commercial corona camera. Geolocation was accomplished with onboard GPS; the UAV position was logged to a local ground station and transmitted in real time to a NASA server for tracking in the national airspace.
Rural, isolated power systems in the mainland U.S. and in states like Alaska and Hawaii are powered by assets like diesel generators. These rural, isolated power systems also cannot operate at the higher band of medium voltage (like 69kV). They are primarily in the 12 to 14 kV range to keep the cost of the distribution investments lower. Because of this mid-band medium voltage range, the line losses and distribution transformers losses consume significant diesel consumption (almost 10 percent of the peak load). This work considers one such power system powering an isolated system and presents key findings online losses, and transformer losses. Understanding and documenting the impacts is critical for these communities operating their power systems and take actions to reduce expensive diesel consumption. In this paper, we will present one such typical grid and model it in electromagnetic transients (EMT) domain. We used the tower structure, under ground cabling installation to develop high fidelity models of lines. We also used high fidelity models of distribution transformers to present the no-load losses and full load loses. We will also present technical solutions available commercially off-the-shelf to reduce these losses and reduce diesel consumption. This work will be a primer for communities to understand the technical challenges and to understand the possible solution available to solve such challenges for rural, isolated power system operators.
The electric field and the magnetic flux changes caused by a ground flash with multiple channels are measured near the electric power transmission lines during winter thunderstorms. Triggered lightning strokes and the following associated strokes to the transmission line towers produce characteristic waveforms of the field changes. A few examples of the waveforms and a brief discussion are given.
Gas absorption towers with structured packing and solvent have been used for Carbon Dioxide (CO 2 ) Capture for about many decades. To overcome process limitations and practical disadvantages for CO 2 capture from the stationary emitter (e.g. NG and coal power plant), many new designs have been proposed and explored at the various scales in the last decade with aim of either low energy penalty or low capital cost. To reduce the size of the absorption tower and hence the total cost of CO 2 capture, the University of Kentucky Center for Applied Energy Research Center (UK CAER) has designed and built a novel CO 2 capture absorption tower or Compact Absorber, integrated into an existing large-bench scale CO 2 capture unit. The Compact Absorber has three sections. The top of the column is a fogging section where the solvent is sprayed through a nozzle producing droplets flowing downward in a co-current fashion with the flue gas. The center of the column is a frothing section where the solvent and flue gas flow through regenerative frothing screens designed by Industrial Climate Solutions, Inc. The bottom of the column is a typical structured packing section were the flue gas and solvent flow in a counter-current fashion. The parametric campaign will be conducted in order to optimize the operating parameters for CO 2 capture including liquid/gas ratio, lean loading, and temperature, liquid residence time. A simulated flue gas with 14% CO 2 will be used along with a UK CAER developed proprietary solvent. The 100-hour parametric campaign is designed using a statistical approach of the Sequential Design of Experiments (sDOE). sDOE is one of the CCSI tools that provides an adaptive statistical approach for designing future experiments based on the results of previous experiments. Application of a typical DOE provides the user with the minimum number of experiments required to get the same data, but sDOE allows the user to make an informed choice of experiments based on the results of previous experiments. The complete absorption column has been constructed and has been partially commissioned. Initial data has been collected by operating using the fogging section and the frothing section. The fogging section produces solvent droplets of about 100 μm sauter mean diameter and as small as 25 μm using a hydraulic nozzle by BETE. The frothing section produces bubbles of about 5mm with high mixing of solvent promoting the higher mass transfer from gas to liquid. The absorber reaches the capture efficiency of about 50% with only two sections in operation. Based on the current results, it can be deduced that increasing the solvent feed temperature and including the packed section for absorption the capture efficiency will increase further. Initial data will be collected using all three sections of the absorber and will be used for sDOE. Non-Uniform Space Filling model of sDOE will be used to prioritize the input conditions resulting into maximum capture efficiency. sDOE is performed using the platform called Framework Optimization, Quantification of Uncertainty, and Surrogates (FOQUS). The method and results demonstrating the progress of the parametric campaign from the initial set of experiments to the final stage of obtaining optimized parameters using sDOE tool will be presented in detail.
The Lunar Communications Terminal (LCT) COllaborative Modeling and Parametric Assessment of Space Systems (COMPASS) session designed a terminal to provide communications between lunar South Pole assets, communications relay to/from these assets through an orbiting Lunar Relay Satellite (LRS) and navigation support. The design included a complete master equipment list, power requirement list, configuration design, and brief risk assessment and cost analysis. The Terminal consists of a pallet containing the communications and avionics equipment, surrounded by the thermal control system (radiator), an attached, deployable 10-m tower, upon which were mounted locally broadcasting and receiving modems and a deployable 1 m diameter Ka/S band dish which provides relay communications with the lunar relay satellites and, as a backup, Earth when it is in view. All power was assumed to come from the lunar outpost Habitat. Three LCT design options were explored: a stand-alone LCT servicing the manned outpost, an integrated LCT (into the Habitat or Lunar Lander), and a mini-LCT which provides a reduced level of communication for primarily robotic areas dealing as in situ resource utilization (ISRU) and remote science. Where possible all the designs assumed single fault tolerance. Significant mass savings were found when integrating the LCT into the Habitat or Lander but increases in costs occurred depending upon the level of man rating required for such designs.
This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site CA-SCB Scotty Creek Bog. This is the FLUXNET version of the carbon flux data for the site CA-SCB Scotty Creek Bog produced by applying the standard ONEFlux (1F) software. Site Description - The Scotty Creek bog flux tower is located in an organic-rich collapse-scar bog about 50 km south of Fort Simpson in the Taiga Plains of the Mackenzie watershed. The tower was installed in 2014 and operates an open-path EC system year-round running on solar power only. The collapse-scar bog is treeless and free of permafrost.
The attached cost and performance spreadsheet model is for a wet cooling tower system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO2 (sCO2) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.
The design and development of a modular solar thermal power system for application in the 1 to 10 MWe range is described. The system consists of five subsystems: the collector, power conversion, energy transport, energy storage, and the plant control subsystem. The collector subsystem consists of concentrator, receiver, and tower assemblies. The energy transport subsystem uses a mixture of salts with a low melting temperature to transport thermal energy. A steam generator drives a steam Rankine cycle turbine which drives an electrical generator to produce electricity. Thermal and stress analysis tests are performed on each subsystem in order to determine the operational reliability, the minimum risk of failure, and the maintenance and repair characteristics.
The modulation transfer function which relates the backscattered microwave power to the long ocean wave field was measured in the North Sea during JONSWAP 75. Results from this tower experiment with an X-band scatterometer are presented and compared with the two-scale wave model (relaxation-time model).
Concentrated solar power (CSP) is one of the most effective ways of harnessing solar power to create efficient, durable, and resilient energy systems. This study entails thermal modeling and analysis of a novel central tower receiver configuration. This receiver uses solid particles as the heat transfer fluid (HTF), a promising option for third-generation CSP systems. The configuration considered here is the light-trapping planar cavity receiver (LTPCR) introduced by the National Renewable Energy Laboratory. While heat transfer studies of various LTPCR subsystems have been done, system-level thermal analysis of the LTPCR receiver has not been attempted. This study also presents important sensitivity analyses of the operating parameters of the CSP system, which can help guide the design of future central tower receivers. This study employs Ansys Fluent as a computational fluid dynamics (CFD) tool to model fluid dynamics and heat transfer in the receiver, intending to quantify its thermal performance. The model seamlessly integrates Monte Carlo ray tracing data, which generates absorbed solar flux profiles from the heliostat field design, with the heat transfer characteristics of the fluidized particle bed. This unified model is designed to accurately predict the thermal behavior of the LTPCR. Analysis of preliminary results reveals that the primary loss mechanisms are radiative and natural convective losses, in that order. Based on observations from a baseline case, several strategies are suggested and numerically tested. These solutions include selective cooling of high-temperature regions and manipulation of particle bed parameters. Selective cooling of high-temperature regions reduced the peak temperature by 151 degrees C and decreased thermal losses by 0.9%. Improving the particle-wall heat transfer coefficient (P-W HTC) of the particle bed decreased the thermal losses by 1.7% and decreased the peak temperatures by 57 degrees C. Decreasing the particle inlet temperature (PIT) also reduced thermal losses by 3.5% and decreased peak temperatures by 29 degrees C. Compounding these strategies improved the thermal losses of the receiver from 13.5% in the baseline case to 7.5%. Additionally, the study explores the variation in thermal performance across different locations of the receiver, where a variation of thermal losses from 12.9% to 17.3% is found. This allows a comprehensive evaluation of potential improvements in efficiency and temperature management.