Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Toward three-dimensional DNA industrial nanorobots

Nanoscale industrial robots have potential as manufacturing platforms and are capable of automatically performing repetitive tasks to handle and produce nanomaterials with consistent precision and accuracy. We demonstrate a DNA industrial nanorobot that fabricates a three-dimensional (3D), optically active chiral structure from optically inactive parts. By making use of externally controlled temperature and ultraviolet (UV) light, our programmable robot, ~100 nanometers in size, grabs different parts, positions and aligns them so that they can be welded, releases the construct, and returns to its original configuration ready for its next operation. Our robot can also self-replicate its 3D structure and functions, surpassing single-step templating (restricted to two dimensions) by using folding to access the third dimension and more degrees of freedom. Our introduction of multiple-axis precise folding and positioning as a tool/technology for nanomanufacturing will open the door to more complex and useful nano- and microdevices.

Robotics↗

Compact instantaneous phase-shifting Sagnac interferometer for nanoscale tilt measurement

There is a large inter disciplinary need for high precision angular sensors in state-of-the-art technologies. This particularly applies to optical metrology in the field of Extreme Ultraviolet (EUV) or X-ray where the optics are commonly characterized in terms of slope errors at a nanoradian scale level. Here, in this paper, we present the in-lab development of an angular sensor based on a single reflection compact Sagnac interferometer using instantaneous phase shifting. Our automated prototype and first results show less than 15 nrad RMS repeatability, at least 200 nrad sensitivity and 280 nrad reproducibility over 100 μrad angular range.

36 MATERIALS SCIENCE↗

Excited-State Charge Distribution of a Donor–π–Acceptor Zn Porphyrin Probed by N K-Edge Transient Absorption Spectroscopy

Zinc porphyrin solar cell dyes with donor-π–acceptor architectures combine light absorber (π), electron-donor, and electron-acceptor moieties inside a single molecule with atomic precision. The donor-π–acceptor design promotes the separation of charge carriers following optical excitation. Here, we probe the excited-state electronic structure within such molecules by combining time-resolved X-ray absorption spectroscopy at the N K-edge with first-principles time-dependent density functional theory (TD-DFT) calculations. Furthermore, customized Zn porphyrins with strong-donor triphenylamine groups or weak-donor tri-tert-butylbenzene groups were synthesized. Energetically well-separated N K-edge absorption features simultaneously probe the excited-state electronic structure from the perspectives of the macrocycle and triphenylamine N atoms. New absorption transitions between the macrocycle N atoms and the excited-state HOMO vacancy are observed, and the triphenylamine associated absorption feature blue-shifts, consistent with partial oxidation of the donor groups in the excited state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Infrared-to-Terahertz Nanospectroscopy of Semiconductors

Semiconductor technology now employs few-nanometer features, necessitating tools probing electronic properties on the same length scale. While the concentration of free charge carriers is routinely measured, the scattering rate remains challenging to access at the nanoscale. Here, we present ultrabroadband (5–50 THz) synchrotron infrared nanospectroscopy as a quantitative metrology tool for semiconductors. This technique can determine both the charge carrier concentration and scattering rate with percent-level accuracy, and it is inherently capable of ∼10 nm spatial resolution. We study silicon with different doping levels and confirm the method’s accuracy by statistical analysis and comparison with established far-field infrared spectroscopy. Near-field measurements systematically reveal charge-carrier concentrations ∼30% lower than far-field values, consistent with increased surface sensitivity and surface depletion. Our work establishes synchrotron infrared nanospectroscopy as a precise tool for quantitative nanoscale semiconductor characterization and paves the way toward all-optical characterization of surface depletion effects.

36 MATERIALS SCIENCE↗

Creating and Interfacing Designer Chemical Qubits (Final Technical Report)

The Final Technical Report describes a multi‑institution effort to develop programmable molecular qubits as precision quantum sensors for probing quantum materials. The team created chemically tunable qubits with optical addressability and practical coherence, integrated them into thin films and frameworks while preserving functionality, and established new magnetic and electric sensing methods suited to two‑dimensional magnets, ferroelectrics, and multiferroics. They also built computational models and spectroscopic tools that connect molecular design to material behavior, enabling access to quantum phenomena that previously could not be measured. The project produced more than 40 publications and trained a large cohort of graduate students and postdocs, strengthening the workforce and infrastructure needed for DOE's quantum information science mission.

2D Quantum Materials↗

Overview of the Fiber System for the Dark Energy Spectroscopic Instrument

The Dark Energy Spectroscopic Instrument (DESI) is a revolutionary instrument designed for precise measurements of cosmic distances and the investigation of dark energy. DESI utilizes 5000 optical fibers to simultaneously measure the spectra of distant objects and aims to measure 40 million galaxies and quasars in a 5 yr survey. One of the critical challenges to DESI's success was ensuring that the fiber system was not only highly efficient but also delivered a highly stable beam enabling more reliable sky subtraction for measurements of faint objects. We achieved this stability by minimizing the stress on the fiber system during the manufacture and operation of the telescope and fiber positioning robots. We installed the DESI fiber system on the 4 m Mayall telescope with ≥99% of fibers intact, and the instrument has delivered superb optical performance throughout the initial years of the DESI survey, including ≥90% average throughput when injected with a focal ratio of ~f/3.9 as delivered by the primary focus corrector, excluding fiber absorption losses. The design of DESI required multiple innovations to achieve these requirements, such as cleaved fibers bonded with a UV-curing epoxy to glass ferrules in the focal plane and fusion splicing instead of physical connectors. In this paper, we describe the development, delivery, and installation of the fiber system, the innovations that made the state-of-the-art performance possible, and the key lessons learned that could benefit future projects.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision beam diagnostics at the NuMI facility using muon monitor observations

The Neutrinos at the Main Injector (NuMI) facility at Fermilab delivers an intense neutrino beam for multiple experiments by producing pions that decay into neutrinos, muons, and other particles. Magnetic horns—the primary pion focusing elements in the NuMI beamline—exhibit predominantly linear optics, enabling a predictable relationship between the proton beam and the resulting pion and muon phase spaces. This study has two primary objectives: first, to evaluate and confirm the linearity of the horn focusing mechanism using analytical models and numerical simulations; and second, to demonstrate that key beam parameters—such as proton beam intensity, beam position on target, and horn current—can be extracted from muon monitor observations within this linear optics framework. Using a machine learning model trained on spill-by-spill muon monitor data, we infer the horn current with a precision of ±0.05%, the beam intensity with ±0.1%, and the beam position on target with ±0.018⁢ mm horizontally and ±0.013⁢ mm vertically. This approach provides a reliable cross-check of beam parameters, helping to reduce systematic uncertainties that are critical for future experiments such as the Deep Underground Neutrino Experiment, which will rely on the neutrino beam produced by the Long-Baseline Neutrino Facility.

Beam control↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

Spatio-temporally shaped deep UV laser source for ultrabright photocathodes using novel upconversion techniques (Final Report)

The goal of this project was to take a VUV laser system designed by Kapteyn-Murnane Labs (KMLabs)—the Hyperion VUV, and increase its functionality, efficiency, and applicability by further probing the fundamental physics taking place in the system and optimizing the system performance. More specifically, DOE accelerator applications—particularly for XFELs that require low-emittance electron beams, require precisely controlled ultrashort pulses in the deep-UV at 250-260 nm to drive the photocathode electron source. This is conventionally done using an ultrafast infrared laser, with subsequent stages of nonlinear upconversion in solid-state nonlinear-optical crystal media (principally BBO, which is commonly used for UV upconversion). However, maintaining high spatial mode beam quality, as well as precisely controlled temporal profile, has proven a persistent challenge. As a possible alternative to this approach, KMLabs has demonstrated a system that generates vacuum ultraviolet light (VUV) by upconverting pulses from an infrared ultrafast laser in a gas-filled hollow waveguide, driving a process of highly cascaded harmonic generation (HCHG). Because HCHG upconversion is done in a gas, rather than a solid, at high intensity in a guided-wave geometry, it retains an excellent beam spatial profile as well as a large spectral bandwidth that allows for control over the temperal structure of the pulse. A challenge, however, is in energy scaling of this HCHG technique to the ~1-20 μJ pulses required for photocathode applications. To-date, the pulse energies used in published HCHG work are sub-10-nJ. This project proposed to explore ways to generate higher-energy pulses using HCHG, as well as to investigate spectral and temporal shaping of the deep UV pulses by pulse shaping the infrared laser used to seed the process. Although we showed that our approach works for generating light at 259 nm, the total pulse energy achieved seems limited to approximately the same value as past work. However, the techniques we investigated may well have benefits for extending this source to much shorter wavelength output.

43 PARTICLE ACCELERATORS↗

Impact of the optical parametric amplification phase on laser pulse compression

Optical parametric chirped-pulse amplification (OPCPA) is an effective way to generate ultrashort pulses that has been used extensively for a variety of applications requiring high peak intensities. Precise control and measurement of a system’s spectral and spatial phases are required for Fourier transform–limited pulse compression and diffraction-limited focusing. Phase accumulated during optical parametric amplification (OPA) can degrade the compressibility and focusability of the pulse, reducing peak intensity. We used analytic and numerical analysis of OPA to study the influence of crystal parameters, wavefront of the pump and signal, and their relative optical alignment on the accumulated phase. Here, we show that the accumulated signal phase is largely independent of amplifier saturation and, with significant local wavefront gradients in the signal or pump beam, the quality of the compressed pulses can be degraded. We use first-order expressions for the pump- and signal-angle sensitivity to evaluate an OPCPA system consisting of a highly deuterated potassium dihydrogen phosphate (DKDP) amplifier designed to support bandwidth for 15 fs pulses centered at 920 nm.

47 OTHER INSTRUMENTATION↗

Orthogonal luminescence lifetime encoding by intermetallic energy transfer in heterometallic rare-earth MOFs

Lifetime-encoded materials are particularly attractive as optical tags, however examples are rare and hindered in practical application by complex interrogation methods. Here, we demonstrate a design strategy towards multiplexed, lifetime-encoded tags via engineering intermetallic energy transfer in a family of heterometallic rare-earth metal-organic frameworks (MOFs). The MOFs are derived from a combination of a high-energy donor (Eu), a low-energy acceptor (Yb) and an optically inactive ion (Gd) with the 1,2,4,5 tetrakis(4-carboxyphenyl) benzene (TCPB) organic linker. Precise manipulation of the luminescence decay dynamics over a wide microsecond regime is achieved via control over metal distribution in these systems. Demonstration of this platform’s relevance as a tag is attained via a dynamic double encoding method that uses the braille alphabet, and by incorporation into photocurable inks patterned on glass and interrogated via digital high-speed imaging. This study reveals true orthogonality in encoding using independently variable lifetime and composition, and highlights the utility of this design strategy, combining facile synthesis and interrogation with complex optical properties.

36 MATERIALS SCIENCE↗

Interferometric measurements of refractive index and dispersion at high pressure

Abstract We describe a high precision interferometer system to measure the pressure dependence of the refractive index and its dispersion in the diamond anvil cell (DAC). The reflective Fabry–Perot fringe patterns created by both a white light and a monochromatic beam are recorded to determine both the sample thickness and its index at the laser wavelength and to characterize the dispersion in the visible range. Advances in sample preparation, optical setup, and data analysis enable us to achieve $$10^{-4}$$ 10 - 4 random uncertainty, demonstrated with an air sample, a factor of five improvement over the best previous DAC measurement. New data on $${\text{H}}_{2}\text{O}$$ H 2 O liquid water and ice VI up to 2.21 GPa at room temperature illustrate how higher precision measurements of the index and its optical dispersion open up new opportunities to reveal subtle changes in the electronic structure of water at high pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D Reconstruction of a High-Energy Diffraction Microscopy Sample Using Multi-modal Serial Sectioning with High-Precision EBSD and Surface Profilometry

High-energy diffraction microscopy (HEDM) combined with in situ mechanical testing is a powerful nondestructive technique for tracking the evolving microstructure within polycrystalline materials during deformation. This technique relies on a sophisticated analysis of X-ray diffraction patterns to produce a three-dimensional reconstruction of grains and other microstructural features within the interrogated volume. However, it is known that HEDM can fail to identify certain microstructural features, particularly smaller grains or twinned regions. Characterization of the identical sample volume using high-resolution surface-specific techniques, particularly electron backscatter diffraction (EBSD), can not only provide additional microstructure information about the interrogated volume but also highlight opportunities for improvement of the HEDM reconstruction algorithms. In this study, a sample fabricated from undeformed “low solvus, high refractory” nickel-based superalloy was scanned using HEDM. The volume interrogated by HEDM was then carefully characterized using a combination of surface-specific techniques, including epi-illumination optical microscopy, zero-tilt secondary and backscattered electron imaging, scanning white light interferometry, and high-precision EBSD. Custom data fusion protocols were developed to integrate and align the microstructure maps captured by these surface-specific techniques and HEDM. The raw and processed data from HEDM and serial sectioning have been made available via the Materials Data Facility (MDF) at https://doi.org/10.18126/4y0p-v604 for further investigation.

36 MATERIALS SCIENCE↗

Delivering laser performance conditions to enable fusion ignition, and beyond at the National Ignition Facility

On December 5th, 2022, controlled fusion ignition was demonstrated for the first time at the National Ignition Facility (NIF), a major achievement in the field of Inertial Confinement Fusion (ICF) requiring a multi-decadal effort involving broad national and international collaborations. To drive the fusion ignition reaction with the compressed fuel capsule, that yielded 3.15 MJ of nuclear energy [1], the NIF laser delivered a high-precision pulse shape with 2.05 MJ of ultra-violet (UV) laser energy and a peak power of 440 TW. This laser energy was an increase of ~8 % compared to that delivered on the previous “threshold of ignition” record yield experiment (1.37 MJ of yield for 1.89 MJ of laser energy) on August 8th, 2021. Here we explain how the results of our extensive research in laser technology and UV optics damage mitigation led to major improvements in the NIF laser, enabling this energy increase along with additional accuracy, precision, and power balance enhancements. Furthermore, we will discuss on-going efforts that have enabled operations at 2.2 MJ of UV energy as well as potential new initiatives to push the laser performance –accuracy and delivered energy– to even higher levels in the future as previously demonstrated on a small subset of NIF beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ionization-Based Optical Structures for the Control of Short-Pulse Lasers (Full LDRD Report)

High-power lasers require enormous beam sizes to avoid optics damage; without plasma control of light, future higher-power systems will have prohibitive costs. The laser-induced formation of ionization patterns in gases provides an opportunity to manipulate the spatial and temporal properties of femtosecond to picosecond beams with precise control at high intensity, providing a path towards compact multi-petawatt lasers. In this project, we proposed new concepts of diffractive optics elements relying on ionization-based structures, including a holographic lens and a compression grating. The theoretical characterization of these optical elements was supported by particle-in-cell simulations. Experiments have been carried out to achieve reflective elements (i.e., plasma-based gratings) that demonstrated high robustness and efficiencies on the order of 50%, which validates the feasibility of our new concepts and paves the way for future plasma-based high-power laser systems.

47 OTHER INSTRUMENTATION↗

A New Reflected Target Optical Assessment System - Stage 1 Development Results: Preprint

NREL has completed stage 1 development of an indoor optical measurement tool for fully assembled heliostats and single facets. This tool began as an indoor version of NREL's NIO technique. It uses similar techniques to other available tools (deflectometry, photogrammetry, etc.), but is designed require very little infrastructure, labor, and time to set up and collect surface slope and canting measurements on fully assembled heliostats and parabolic trough facets, making it a valuable tool for quality assurance and laboratory measurement of helio-stat optics. It accomplishes this by using computer vision, photogrammetry, and multiple images stitched together to minimize the printed target size and required setup precision. This adaptable setup is useful for taking measurements at a variety of heliostat pointing angles, and for measuring fully assembled heliostats on the assembly line. The measurement system's methodology and an analysis of its uncertainty, sensitivity and comparison with established optical measurement systems is described below.

canting↗

Understanding the unique optical and vibrational signatures of sequential infiltration synthesis derived indium oxyhydroxide clusters for CO 2 absorption

Sequential infiltration synthesis (SIS) is a vapor phase synthesis technique with potential to exert precise control over metal oxyhydroxide incorporation into polymer scaffolds. Here, we observe strong size-dependent properties of InO x (OH) y few-atom clusters deposited with variable SIS cycle numbers within a polymethylmethacrylate (PMMA) matrix. Infrared spectroscopy and ultraviolet-visible absorption spectroscopy reveal that the metal atom coordination and optical properties of the clusters depend on the number of SIS cycles performed as well as the choice of processing parameters. The incorporation of indium oxyhydroxide in PMMA via SIS presents an opportunity to improve the CO 2 absorption capacity and gas selectivity of inexpensive polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wireless Optogenetic Modulation of Cortical Neurons Enabled by Radioluminescent Nanoparticles

While offering high precision control of neural circuits, optogenetics is hampered by the necessity to implant fiber-optic waveguides in order to deliver photons to genetically engineered light-gated neurons in the brain. Unlike laser light, X-rays freely pass biological barriers. In this work, we show that radioluminescent Gd 2 (WO 4 ) 3 :Eu nanoparticles, which absorb an external X-rays energy and then down-converter it into optical photons with wavelengths of ~610 nm, can be used for the transcranial stimulation of cortical neurons expressing red-shifted, ~590-630 nm, channelrhodopsin ReaChR, thereby promoting optogenetic neural control to the practical implementation of minimally-invasive wireless deep brain stimulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗