Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse Reactor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online residence time distribution measurement of thermochemical biomass pretreatment reactors

Residence time is a critical parameter that strongly affects the product profile and overall yield achieved from thermochemical pretreatment of lignocellulosic biomass during production of liquid transportation fuels. The residence time distribution (RTD) is one important measure of reactor performance and provides a metric to use when evaluating changes in reactor design and operating parameters. An inexpensive and rapid RTD measurement technique was developed to measure the residence time characteristics in biomass pretreatment reactors and similar equipment processing wet-granular slurries. Sodium chloride was pulsed into the feed entering a 600 kg/d pilot-scale reactor operated at various conditions, and aqueous salt concentration was measured in the discharge using specially fabricated electrical conductivity instrumentation. This online conductivity method was superior in both measurement accuracy and resource requirements compared to offline analysis. Experimentally measured mean residence time values were longer than estimated by simple calculation and screw speed and throughput rate were investigated as contributing factors. In conclusion, a semi-empirical model was developed to predict the mean residence time as a function of operating parameters and enabled improved agreement.

09 BIOMASS FUELS↗

Neutron lifetimes behavior analysis considering the two-region kinetic model in the IPEN/MB-01 reactor

This is a complementary work about the behavior analysis of the neutron lifetimes that was developed in the IPEN/MB-01 nuclear reactor facility. The macroscopic neutron noise technique was experimentally employed using pulse mode detectors for two stages of control rods insertion, where a total of twenty levels of subcriticality have been carried out. It was also considered that the neutron reflector density was treated as an additional group of delayed neutrons, being a sophisticated approach in the two-region kinetic theoretical model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SANDD: A directional antineutrino detector with segmented 6 Li-doped pulse-shape-sensitive plastic scintillator

We present a characterization of a small (9-liter) and mobile 0.1% 6 Li-doped pulse-shape-sensitive plastic scintillator antineutrino detector called SANDD (Segmented AntiNeutrino Directional Detector), constructed for the purpose of near-field reactor monitoring with sensitivity to antineutrino direction. SANDD comprises three different types of module. A detailed Monte Carlo simulation code was developed to match and validate the performance of each of the three modules. The combined model was then used to produce a prediction of the performance of the entire detector. Analysis cuts were established to isolate antineutrino inverse beta decay events while rejecting large fraction of backgrounds. The neutron and positron detection efficiencies are estimated to be 34.8% and 80.2%, respectively, while the coincidence detection efficiency is estimated to be 71.7%, resulting in inverse beta decay detection efficiency of 20.0% ± 0.2%(stat.) ± 2.1%(syst.). Finally, the predicted directional sensitivity of SANDD produces an uncertainty of 20° in the azimuthal direction per 100 detected antineutrino events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stochastic simulation for the propagation of high-frequency acoustic waves through a random velocity field

In-service inspection of Sodium-Cooled Fast Reactors (SFR) requires the development of non-destructive techniques adapted to the harsh environment conditions and the examination complexity. From past experiences, ultrasonic techniques are considered as suitable candidates. The ultrasonic telemetry is a technique used to constantly insure the safe functioning of reactor inner components by determining their exact position: it consists in measuring the time of flight of the ultrasonic response obtained after propagation of a pulse emitted by a transducer and its interaction with the targets. While in-service the sodium flow creates turbulences that lead to temperature inhomogeneities, which translates into ultrasonic velocity inhomogeneities. These velocity variations could directly impact the accuracy of the target locating by introducing time of flight variations. A stochastic simulation model has been developed to calculate the propagation of ultrasonic waves in such an inhomogeneous medium. Using this approach, the travel time is randomly generated by a stochastic process whose inputs are the statistical moments of travel times known analytically. The stochastic model predicts beam deviations due to velocity inhomogeneities, which are similar to those provided by a determinist method, such as the ray method.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Plan for IER-443 Testing of the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor

This document provides the scope and details of the “Plan for Testing the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor”. Due to the relative simplicity of the testing goals, scope, and methodology, the NCSP Manager approved execution of the test when ready. No preliminary CED-1 or final design CED-2 reports were required or issued. The test will subject Criticality Accident Alarm System (CAAS) detectors supplied by Y- 12 and AWE to very intense and short duration mixed neutron and gamma radiation fields. The goals of the test will be to (1) substantiate functionality, for both existing and newly acquired Y- 12 CAAS detectors, and (2) the ability of the AWE detectors to provide quality temporal dose information after a hypothetical criticality accident. ANSI/ANS-8.3.1997 states that the “system shall be sufficiently robust as to actuate an alarm signal when exposed to the maximum radiation expected”, which has been defined at Y-12, in Documented Safety Analyses (DSAs), to be a dose rate of 10 Rad/s. ANSI/ANS-8.3.1997 further states that “alarm actuation shall occur as a result of a minimum duration transient” which may be assumed to be 1 msec. The pulse widths and dose rates which will be achieved in this test will exceed these requirements. Pulsed radiation fields will be produced by the Godiva IV fast metal burst reactor at the National Criticality Experimental Research Center (NCERC) at the Nevada National Security Site (NNSS). The magnitude of the pulses and the relative distances to the detectors will be varied to afford a wide range of radiation fluence and pulse widths. The magnitude of the neutron and gamma fields will be determined by reactor temperature rise to fluence and dose conversions which have been previously established through extensive measurements performed under IER-147. The requirements for CAAS systems to detect and alarm under a “minimum accident of concern” as well as other functional requirements specified in ANSI/ANS-8.3.1997, are not included in the test. Routine and periodic maintenance and calibrations performed at Y-12 and AWE are intended to provide adequate confirmation for meeting these requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Defects in Additively Manufactured Metallic Materials with Machine Learning of Pulsed Thermography Images

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of nuclear reactor parts. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which can introduce internal material flaws, such as pores and anisotropy. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to exposure to high temperature, radiation and corrosive environment in a nuclear reactor. Quality control (QC) requires nondestructive evaluation (NDE) of actual AM structures. Pulsed thermography is a potentially promising QC technique because it is scalable to arbitrary structure size. However, detection sensitivity of this method is limited by noises. We investigate separation of signal from noise in thermography images using several machine learning (ML) methods, including new spatio-temporal blind source separation (STBSS) and spatio-temporal sparse dictionary learning (STSDL) methods. Performance of the ML methods is benchmarked using thermography data obtained from imaging stainless steel 316L and Inconel 718 specimens produced LPBF method with imprinted calibrated porosity defects. The ML methods are ranked by F-score and execution runtime. The ML methods with higher accuracy require longer run time. However, this runtime is sufficiently short to perform QC within a realistic time frame.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Precise non-steady-state characterization of solid active materials with no preliminary mechanistic assumptions

This paper presents a straightforward and user-friendly procedure for extracting a reactivity characterization of catalytic reactions on solid materials under non-steady-state conditions, particularly in temporal analysis of products (TAP) experiments. The kinetic parameters derived by this procedure can help with the development of detailed mechanistic understanding. The procedure consists of the following two major steps: 1) Three “Laplace reactivities” are first determined based on the moments of the exit flow pulse response data; 2) Depending on a select kinetic model, kinetic constants of elementary reaction steps can then be expressed as a function of reactivities and determined accordingly. In particular, we distinguish two calculation methods based on the availability and reliability of reactant and product data. The theoretical results are illustrated using a reverse example with given parameters as well as an experimental example of CO oxidation over a supported Au/SiO 2 catalyst. The procedure presented here provides an efficient tool for kinetic characterization of many complex chemical reactions.

03 NATURAL GAS↗

Performance of large-scale 6 Li-doped pulse-shape discriminating plastic scintillators

A 6 Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ -299-50, has been developed and produced at the kilogram-scale. A total of 44 bars of dimensions 5.5 cm x 5.5 cm x 50 cm of this material have been characterized. Optical properties like light output and effective attenuation length have been found to be comparable to 6 Li-doped liquid scintillators. Further, the scintillator EJ -299-50 shows good neutron detection capabilities with an effective efficiency for capture on 6 Li of approximately 85%. Stability tests performed on two formulation variations showed no intrinsic degradation in the material or optical properties during several months of observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation-induced reaction kinetics of Zn 2+ with e S - and Cl 2 ˙ - in Molten LiCl–KCl eutectic at 400–600 °C

We report molten chloride salts are currently under consideration as combined coolant and liquid fuel for next-generation molten salt nuclear reactors. Unlike complementary light-water reactor technologies, the radiation science underpinning molten salts is in its infancy, and thus requires a fundamental mechanistic investigation to elucidate the radiation-driven chemistry within molten salt reactors. Here we present an electron pulse radiolysis kinetics study into the behaviour of the primary radiolytic species generated in molten chloride systems, i.e., the solvated electron (e S - ) and di-chlorine radical anion (Cl 2 ˙- ). We examine the reaction of e S - with Zn 2+ from 400–600 °C (E a = 30.31 ± 0.09 kJ mol -1 ), and the kinetics and decay mechanisms of Cl 2 ˙- in molten lithium chloride-potassium chloride (LiCl–KCl) eutectic. In the absence of Zn 2+ , the lifetime of e S - was found to be dictated by residual impurities in ostensibly “pure” salts, and thus the observed decay is dependent on sample history rather than being an intrinsic property of the salt. The decay of Cl 2 ˙- is complex, owing to the competition of Cl 2 ˙- disproportionation with several other chemical pathways, one of which involves reduction by radiolytically-produced Zn + species. Overall, the reported findings demonstrate the richness and complexity of chemistry involving the interactions of ionizing radiation with molten salts.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurements and kinetic modeling of O 2 vibrational kinetics in O 2 –Ar mixtures partially dissociated by a Ns pulse discharge

Vibrational kinetics of O 2 is studied during the O atom recombination in an O 2 –Ar mixture, partially dissociated by a burst of ns discharge pulses in a heated plasma flow reactor. The time-resolved temperature in the discharge afterglow is determined by Rayleigh scattering. Time-resolved O atom number density is measured by ps Two-Photon absorption Laser Induced Fluorescence, calibrated in xenon. Time-resolved vibrational level populations of molecular oxygen, O 2 (v= 8–20), are measured by ps Laser Induced Fluorescence (LIF), with the absolute calibration by NO LIF. Time-resolved ozone number density is monitored by broadband UV absorption. The results are compared with the predictions of a state-specific kinetic model. The experimental data indicate a rapid initial decay of O 2 (v) populations generated by electron impact in the discharge, due to the vibration-translation (V–T) relaxation by O atoms. This is followed by a slower population reduction, on the time scale much longer compared to that for V–T relaxation or vibration-vibration (V–V) exchange. Both O atoms and the O 2 (v) populations decay on the same time scale, indicating that chemical reactions initiated by the O atom recombination result in the generation of vibrationally excited O 2 molecules. These trends are reproduced by the kinetic model, which shows that the reaction of O atoms with ozone is the dominant pathway of O 2 (v) generation at the present conditions. The predicted relative O 2 (v) populations are close to the experimental results, but absolute number densities differ from the experimental data. This is likely due to uncertainties in the absolute calibration of LIF measurements and in the spectroscopic model used in the data reduction. The present work demonstrates the capability for the absolute, time-resolved measurements of vibrationally excited O 2 in recombining gas flows, to quantify the energy partition in the recombination reactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of tokamak vertical stability control based on non-inductive Faraday-effect polarimetry measurements

Long-pulse or steady-state fusion reactors are envisioned to control vertical stability based on non-inductive measurements, i.e. that do not rely on temporal change of magnetic field. For the first time, vertical stability control using non-inductive Faraday-effect polarimetry measurements has been demonstrated. The Radial Interferometer-Polarimeter system on DIII-D is capable of microsecond resolution and was used to absolutely determine the vertical position of the plasma magnetic axis Z 0 . A vertical stability controller was developed to robustly stabilize diverted plasmas using Faraday-based measurements. The system was able to stabilize against vertical displacement events with growth rates up to 350 s -1 in elongated and elliptical plasma shapes, and instabilities with even higher growth rates are likely to be controllable with further improvements to controller tuning. Tests show that the Faraday-based controller remains effective and is capable of recovering from loss of control even when the plasma vertical position is far from the region where the linear model used to calculate Z 0 is most valid. Faraday control has also been activated during plasma ramp-up, demonstrating the robustness of the technique to larger systematic diagnostic uncertainty at low electron density.

Faraday-effect polarimetry↗

Z Machine at Sandia Labs

Sandia Labs' Z machine is the largest laboratory source of x-rays in the world. For the few nanoseconds of a Z Machine test, its electrical output equals the output of 50x the electrical generating stations of all the power plants on earth. The Z Machine complex encompasses an area roughly the size of a major college basketball arena. Originally created to validate nuclear weapons models, the Z Machine is also considered a "dark horse" in the race for viable fusion energy production. After the famous "arcs and sparks" photo of Z (a photo no longer possible after its refurbishment), this is a fast-motion video of workers completing Z's recent refurbishment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Power matching to pulsed inductively coupled plasmas

Matching of power delivery to nonlinear loads in plasma processing is a continuing challenge. Plasma reactors used in microelectronics fabrication are increasingly multi-frequency and/or pulsed, producing a non-linear and, in many cases, non-steady state electrical termination that can complicate efficient power coupling to the plasma. This is particularly the case for pulsed inductively coupled plasmas where the impedance of the plasma can significantly change during the start-up-transient and undergo an E–H (capacitive-to-inductive) transition. In this paper, we discuss the results from a computational investigation of the dynamics of power matching to pulsed inductively coupled plasmas (Ar/Cl 2 mixtures of tens of mTorr pressure) using fixed component impedance matching networks and their consequences on plasma properties. In this investigation, we used set-point matching where the components of the matching network provide a best-case impedance match (relative to the characteristic impedance of the power supply) at a chosen time during the pulsed cycle. Matching impedance early during the pulse enables power to feed the E-mode, thereby emphasizing capacitive coupling and large excursions in the plasma potential. This early power coupling enables a more rapid ramp-up in plasma density while being mismatched during the H-mode later in the pulse. The early match also produces more energetic ion bombardment of surfaces. Matching late in the pulse diminishes power dissipated in the E-mode at the cost of also reducing the rate of increase in plasma density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of wall conditions on the self-limiting deposition of metal oxides by pulsed plasma-enhanced chemical vapor deposition

Pulsed plasma-enhanced chemical vapor deposition has been engineered to deliver self-limiting growth (i.e., {approx}A /pulse) of metal oxides such as Ta{sub 2}O{sub 5} and Al{sub 2}O{sub 3}. In this process the reactor walls are alternately exposed to atomic oxygen and metal precursors. The degree of adsorption in the latter step can dramatically influence both deposition rates and film quality. The impact of precursor adsorption on the plasma and gas-phase composition in these systems was quantified using optical emission spectroscopy and quadrupole mass spectrometry, respectively. It is shown that the time scale for a complete adsorption on the chamber walls is much greater than gas-phase residence times. Adsorbed compounds significantly alter the reactor composition, particularly at the initiation of each plasma pulse. As a consequence, careful attention must be paid to reactor design and operation to control deposition rates and maintain film quality.

36 MATERIALS SCIENCE↗

Instrumentation and Data Analysis Supporting the Transient Rod Pneumatic System Design Study at the Annular Core Research Reactor

The Sandia National Laboratories Annular Core Research Reactor (ACRR) has been experiencing intermittent failures of its pneumatically operated transient rod system. The most frequent failures have been to the dashpot rod where it connects to the upper aluminum connecting rod. Within the three systems, Transient Rod (TR) A has the most frequent failures. In order to conduct the pulse operations, the Transient Rods are pneumatically driven to quickly remove "poison" from the reactor core. During these pulse operations increased forces and vibrations are placed on the TR system. In an effort to fix these problems, Sandia's TA-V Nuclear Reactor and Systems Engineering Department (Engineering Department) has started an extensive Transient Rod Pneumatic System Design Study. The goal of this study is to determine the causes of the elevated failure rates in TR A. This necessitates an increased understanding of the dynamics in the TR systems. This report will cover the approach taken and reasoning behind the choices of instrumentation, calibration, data collection and data analysis used to diagnose these failures. In order to determine the types and specifications for the sensors that will be installed, estimates of the TR system performance needed to be determined. Using known and assumed parameters, mechanical and thermodynamic models were developed, and calculations performed to estimate ranges of displacement, speed, and acceleration experienced by the transient rod system. After some preliminary data collection, the thermodynamic models were refined for better accuracy. After installation of the full suite of sensors, data can be collected and analyzed in order to determine the cause of the increased failures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Initial Neutronics Analyses for HEU to LEU Fuel Conversion of the Transient Reactor Test Facility (TREAT) at the Idaho National Laboratory

The purpose of the TREAT reactor is to generate large transient neutron pulses in test samples without over-heating the core to simulate fuel assembly accident conditions. The power transients in the present HEU core are inherently self-limiting such that the core prevents itself from overheating even in the event of a reactivity insertion accident. The objective of this study was to support the assessment of the feasibility of the TREAT core conversion based on the present reactor performance metrics and the technical specifications of the HEU core. The LEU fuel assembly studied had the same overall design, materials (UO 2 particles finely dispersed in graphite) and impurities content as the HEU fuel assembly. The Monte Carlo N–Particle code (MCNP) and the point kinetics code TREKIN were used in the analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗