Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIO FREQUENCY IDENTIFICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Sounder stimulated D(sub n) resonances in Jupiter's Io plasma torus

On February 8, 1992, the Ulysses spacecraft passed through Jupiter's Io plasma torus, where rich spectra of narrow-band resonances were stimulated by the relaxation sounder of the Ulysses unified radio and plasma wave (URAP) instrument. Since the gyrofrequency f(sub g) is comparable to the plasma frequency f(sub p) in the Io torus, it was predicted that the general classification of stimulated ionospheric D(sub n) resonances, developed for 1 is less than or equal to f(sub p)/f(sub g) is less than or equal to 8 in the Earth's topside ionosphere, should apply in the Io torus as well as the Earth's magnetosphere (Osherovich, 1989). The URAP plasmagrams (sounder spectra) in the portions of the Io torus satisfying these plasma conditions are dominated by the D(sub n) resonances for frequencies below f(sub p). On most of these plasmagrams the f(sub p) resonance is also present, but it is seldom the dominant resonance. Neither upper hybrid nor nf(sub g) resonances have been found on these plasmagrams. The identification of D(sub n) resonances has allowed both the electron density and the magnetic field amplitude to be calculated. The derived densities on the outbound pass agree well with a Voyager model of Bagenal (1992). The derived magnetic field values are close to the Goddard Space Flight Center O(sub 6) magnetic field model.

Osherovich, V. A.↗

Wideband very large array observations of A2256. I. Continuum, rotation measure, and spectral imaging

We report new observations of A2256 with the Karl G. Jansky Very Large Array (VLA) at frequencies between 1 and 8 GHz. These observations take advantage of the 2:1 bandwidths available during a single observation to study the spectral index, polarization, and rotation measure as well as using the associated higher sensitivity per unit time to image total intensity features down to ∼0.''5 resolution. We find that the Large Relic, which dominates the cluster, is made up of a complex of filaments that show correlated distributions in intensity, spectral index, and fractional polarization. The rotation measure varies across the face of the Large Relic but is not well correlated with the other properties of the source. The shape of individual filaments suggests that the Large Relic is at least 25 kpc thick. We detect a low surface brightness arc connecting the Large Relic to the Halo and other radio structures, suggesting a physical connection between these features. The center of the F-complex is dominated by a very steep-spectrum, polarized, ring-like structure, F2, without an obvious optical identification, but the entire F-complex does have interesting morphological similarities to the radio structure of NGC 1265. Source C, the Long Tail, is unresolved in width near the galaxy core and is ≲ 100 pc in diameter there. This morphology suggests either that C is a one-sided jet or that the bending of the tails takes place very near the core, consistent with the parent galaxy having undergone extreme stripping. Overall it seems that many of the unusual phenomena can be understood in the context of A2256 being near the pericenter of a slightly off-axis merger between a cluster and a smaller group. Given the lack of evidence for a strong shock associated with the Large Relic, other models should be considered, such as reconnection between two large-scale magnetic domains.

79 ASTRONOMY AND ASTROPHYSICS↗

COMMISSIONING OF THE SRF SURFACE IMPEDANCE CHARACTERIZATION SYSTEM AT JEFFERSON LAB

Superconducting radio frequency (SRF) technology is widely adopted in particle accelerators. There remain many open questions, however, in developing a systematic understanding of the fundamental behavior of SRF materials, including niobium treated in different ways and various other bulk/thin film materials that are fabricated with different methods under assorted conditions. A facility that can measure the SRF properties of small samples in a range of 0~180 mT surface field and 2~20 K temperature is needed in order to fully answer these questions. The Jefferson Lab surface impedance characterization (SIC) system [1] has been designed to attempt to meet this requirement. It consists of a sapphire-loaded cylindrical Nb TE011 cavity at 7.5 GHz with a 50 mm diameter flat sample placed on a non-contacting end plate and uses a calorimetric technique [2-5] to measure the rf induced heat on the sample. Driving the resonance to a known field on this surface enables one to derive the surface resistance of the small localized area. TE011 mode identification has been done at room temperature and 4 K, and has been compared with Microwave Studio® simulation results. The variable input and transmitted rf couplers have been characterized. Rf loss mechanisms in the SIC system are under investigation. Thermal properties of the calorimeter have been well studied. A second generation calorimeter is being developed to optimize the dynamic range of the system. A prototype VCO phase lock loop system has been used in CW mode. Preliminary tests with bulk Nb samples have been done at <3 mT magnetic field. The presently available hardware is expected to enable up to 20 mT peak magnetic field on the sample, and paths to higher field tests have been identified.

Xiao, Binping↗

Surface structure studies in 2D and 3D Nb resonators using GI-XRD

Superconductor radio frequency (SRF) Nb-resonators are a key element in the development of new generations of particle accelerators as well as in the fabrication of 3D circuit QED architecture for quantum computing. Nevertheless, Niobium is extremally reactive to light elements such as C, N, O and H, and therefore to the impurities ordering under special conditions, e.g., cryogenic temperatures. Since these resonators are put through a series of metallurgical and chemical processes, the number of impurities in the solid increases in tens of ppm. Upon operational conditions ~1.6 K, Nb become vulnerable to H atoms ordering, which leads to the nucleation of secondary phases such as Nb-hydrides. Thereupon to the energy dissipation and eventually to the superconductivity breakdown known as Q-disease and potentially High-Field Q-slope. In this contribution, we present a detailed structural analysis by high-energy grazing-incidence X-ray diffraction of specimens extracted from 3D Nb resonators to shed light on the kinetic formation of the resulting secondary phases and their crystal phase identification upon cooling and heating cycles. To our knowledge, this is the first study carried out in resonators samples using a light source, shallow angles and temperatures near ~4 K. Consequently, this work opens new routes to understand the chemical and phase composition, crystal and electronic structure of the Nb surface at temperatures near the operating conditions as a strategy to improve the physical and functional properties of Nb superconducting resonators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long gravitational-wave transients and associated detection strategies for a network of terrestrial interferometers

Searches for gravitational waves (GWs) traditionally focus on persistent sources (e.g., pulsars or the stochastic background) or on transients sources (e.g., compact binary inspirals or core-collapse supernovae), which last for time scales of milliseconds to seconds. We explore the possibility of long GW transients with unknown waveforms lasting from many seconds to weeks. We propose a novel analysis technique to bridge the gap between short O(s)''burst'' analyses and persistent stochastic analyses. Our technique utilizes frequency-time maps of GW strain cross power between two spatially separated terrestrial GW detectors. The application of our cross power statistic to searches for GW transients is framed as a pattern recognition problem, and we discuss several pattern-recognition techniques. We demonstrate these techniques by recovering simulated GW signals in simulated detector noise. We also recover environmental noise artifacts, thereby demonstrating a novel technique for the identification of such artifacts in GW interferometers. We compare the efficiency of this framework to other techniques such as matched filtering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time series comparisons in Deep Space Network

The Deep Space Network (DSN) is NASA’s international array of antennas that support interplanetary spacecraft missions. DSN provides radar and radio astronomy observations that enhance our understanding of the solar system and the larger universe. A track is a block of continuous multi-dimensional time series from the beginning to end of DSN communication with the target spacecraft, containing 129 monitor data items lasting several hours at a frequency of 0.2-1Hz. Monitor data on each track reports on the performance of specific spacecraft operations and the DSN itself. DSN is receiving signals from 32 spacecraft across the solar system. DSN has pressure to reduce costs while maintaining the quality of support for DSN mission users. DSN operators need to simultaneously monitor multiple tracks and identify anomalies in real time. DSN has seen that as the number of missions increases, the data that needs to be processed increases over time. In this project, we look at the last 8 years of data for analysis. Any anomaly in the track indicates a problem with either the spacecraft, DSN equipment, or weather conditions. DSN operators typically write “discrepancy reports” for further analysis. It is recognized that it would be quite helpful to identify 10 similar historical tracks out of the huge database to quickly find/match anomalies. This tool has three functions: (1) identification of the top 10 similar historical tracks, (2) detection of anomalies compared to the reference normal track, and (3) comparison of statistical differences between two given tracks. The requirements for these features were confirmed by survey responses from 21 DSN operators and engineers. The preliminary machine learning model has shown promising performance (AUC=0.92). We plan to increase the number of data sets and perform additional testing to improve performance further before its planned integration into the Track Visualizer to assist DSN field operators and engineers.

Rebbapragada, Umaa↗

HIGH-n HYDROGEN RECOMBINATION LINES FROM THE FIRST GALAXIES

We investigate the prospects of blind and targeted searches in the radio domain (10 MHz to 1 THz) for high-n hydrogen recombination lines from the first generation of galaxies, at z ∼< 10. The expected optically thin spontaneous α-line luminosities are calculated as a function of the absolute AB magnitude of a galaxy at 1500 Å. For a blind search, semi-empirical luminosity functions are used to calculate the number of galaxies whose expected flux densities exceed an assumed detectability threshold. Plots of the minimum sky area, within which at least one detectable galaxy is expected at a given observing frequency, in the fiducial instantaneous passband of 10{sup 4} km s{sup –1}, allow us to assess the blind search time necessary for detection by a given facility. We show that the chances for detection are the highest in the millimeter and submillimeter domains, but finding spontaneous emission in a blind search, especially from redshifts z >> 1, is a challenge even with powerful facilities, such as the Actama Large Millimeter/Submillimeter Array and Square Kilometre Array. The probability of success is higher for a targeted search of lines with principal quantum number n ∼ 10 in Lyman-break galaxies amplified by gravitational lensing. Detection of more than one hydrogen line in such a galaxy will allow for line identification and a precise determination of the galaxy's redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

The discovery of a radio galaxy of at least 5 Mpc

Context. Giant radio galaxies (GRGs, or colloquially ‘giants’) are the Universe’s largest structures generated by individual galaxies. They comprise synchrotron-radiating active galactic nucleus ejecta and attain cosmological (megaparsec-scale) lengths. However, the main mechanisms that drive their exceptional growth remain poorly understood. Aims. To deduce the main mechanisms that drive a phenomenon, it is usually instructive to study extreme examples. If there exist host galaxy characteristics that are an important cause for GRG growth, then the hosts of the largest GRGs are likely to possess them. Similarly, if there exist particular large-scale environments that are highly conducive to GRG growth, then the largest GRGs are likely to reside in them. For these reasons, we aim to perform a case study of the largest GRG available. Methods. We reprocessed the LOFAR Two-Metre Sky Survey DR2 by subtracting compact sources and performing multi-scale CLEAN de-convolutions at 60" and 90" resolution. The resulting images constitute the most sensitive survey yet for radio galaxy lobes, whose diffuse nature and steep synchrotron spectra have allowed them to evade previous detection attempts at higher resolution and shorter wavelengths. We visually searched these images for GRGs. Results. We have discovered Alcyoneus, a low-excitation radio galaxy with a projected proper length l p = 4.99 ± 0.04 Mpc. Both its jets and lobes are detected at very high significance, and the SDSS-based identification of the host, at spectroscopic redshift z spec = 0.24674 ± 6 × 10 -5 , is unambiguous. The total luminosity density at ν = 144 MHz is L ν = 8 ± 1 × 10 25 W Hz -1 , which is below average, though near median (percentile 45 ± 3%) for GRGs. The host is an elliptical galaxy with a stellar mass M* = 2.4 ± 0.4 × 10 11 M ⊙ and a super-massive black hole mass M• = 4 ± 2 × 10 8 M ⊙ , both of which tend towards the lower end of their respective GRG distributions (percentiles 25 ± 9% and 23 ± 11%). The host resides in a filament of the Cosmic Web. Through a new Bayesian model for radio galaxy lobes in three dimensions, we estimate the pressures in the megaparsec-cubed-scale northern and southern lobes to be P min,1 = 4.8 ± 0.3 × 10 -16 Pa and P min,2 = 4.9 ± 0.6 × 10 -16 Pa, respectively. The corresponding magnetic field strengths are B min,1 = 46 ± 1 pT and B min,2 = 46 ± 3 pT. Conclusions. We have discovered what is in projection the largest known structure made by a single galaxy – a GRG with a projected proper length l p = 4.99 ± 0.04 Mpc. The true proper length is at least l min = 5.04 ± 0.05 Mpc. Beyond geometry, Alcyoneus and its host are suspiciously ordinary: the total low-frequency luminosity density, stellar mass, and super-massive black hole mass are all lower than, though similar to, those of the medial GRG. Thus, very massive galaxies or central black holes are not necessary to grow large giants, and, if the observed state is representative of the source over its lifetime, neither is high radio power. A low-density environment remains a possible explanation. The source resides in a filament of the Cosmic Web, with which it might have significant thermodynamic interaction. The pressures in the lobes are the lowest hitherto found, and Alcyoneus therefore represents the most promising radio galaxy yet to probe the warm–hot inter-galactic medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Prompt Gamma Neutron Activation Analysis of Niobium for Characterization of Light Interstitials

High purity niobium metal is used in the construction of superconducting radio frequency (SRF) cavities in superconducting particle accelerators. The Spallation Neutron Source at Oak Ridge National Laboratory is an example of an SRF linear accelerator (LINAC) that requires this high purity niobium material. For the SRF cavities to function well, it is necessary that the cavity wall have a high thermal conductivity so that the radio frequency (RF) power can be dissipated into the liquid helium coolant. For a high thermal conductivity of the niobium metal to be achieved, it is required to have extremely low levels of impurities. The current industry standard for determining the quality of the high purity niobium material is the residual resistivity ratio (RRR) technique. In this technique, the temperature dependency of a niobium metal sample is determined at temperatures near that of liquid helium in order to establish where the superconducting jump occurs. With this method, it is possible to find the general level of impurity of the metal sample, but not the specific elements that are contributing to the impurity. The impurities that are of particular interest to manufacturers of niobium for SRF use are tantalum and light interstitials, such as hydrogen, carbon, nitrogen, and oxygen. In this research, we focus on determining the analytical sensitivity of the detector system and characterizing the light interstitial content in high purity niobium metal through the use of Prompt Gamma Neutron Activation Analysis (PGNAA). PGNAA is an analytical technique that can be utilized to determine the concentration of elemental components in a wide variety of materials with high precision and reproducibility. In this process, neutrons bombard a sample material, causing the emission of gamma rays from the sample. Each element emits a unique spectrum of gamma radiation, which allows for identification of the elements present in the sample. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The NASA Soil Moisture Active Passive (SMAP) Mission - Algorithm and Cal/Val Activities and Synergies with SMOS and Other L-Band Missions

NASA's Soil Moisture Active Passive (SMAP) mission, planned for launch in late 2014, has as its key measurement objective the frequent, global mapping of near-surface soil moisture and its freeze-thaw state. SMAP soil moisture and freeze/thaw measurements at 10 km and 3 km resolutions respectively, would enable significantly improved estimates of water, energy and carbon transfers between the land and atmosphere. Soil moisture control of these fluxes is a key factor in the performance of atmospheric models used for weather forecasts and climate projections Soil moisture measurements are also of great importance in assessing floods and for monitoring drought. In addition, observations of soil moisture and freeze/thaw timing over the boreal latitudes can help reduce uncertainties in quantifying the global carbon balance. The SMAP measurement concept utilizes an L-band radar and radiometer sharing a rotating 6-meter mesh reflector antenna. The SMAP radiometer and radar flight hardware and ground processing designs are incorporating approaches to identify and mitigate potential terrestrial radio frequency interference (RFI). The radar and radiometer instruments are planned to operate in a 680 km polar orbit, viewing the surface at a constant 40-degree incidence angle with a 1000-km swath width, providing 3-day global coverage. Data from the instruments would yield global maps of soil moisture and freeze/thaw state to be provided at 10 km and 3 km resolutions respectively, every two to three days. Plans are to provide also a radiometer-only soil moisture product at 40-km spatial resolution. This product and the underlying brightness temperatures have characteristics similar to those provided by the Soil Moisture and Ocean Salinity (SMOS) mission. As a result, there are unique opportunities for common data product development and continuity between the two missions. SMAP also has commonalities with other satellite missions having L-band radiometer and/or radar sensors applicable to soil moisture measurement, such as Aquarius, SAO COM, and ALOS-2. The algorithms and data products for SMAP are being developed in the SMAP Science Data System (SDS) Testbed. The algorithms are developed and evaluated in the SDS Testbed using simulated SMAP observations as well as observational data from current airborne and spaceborne L-band sensors including SMOS. The SMAP project is developing a Calibration and Validation (Cal/Val) Plan that is designed to support algorithm development (pre-launch) and data product validation (post-launch). A key component of the Cal/Val Plan is the identification, characterization, and instrumentation of sites that can be used to calibrate and validate the sensor data (Level I) and derived geophysical products (Level 2 and higher). In this presentation we report on the development status of the SMAP data product algorithms, and the planning and implementation of the SMAP Cal/Val program. Several components of the SMAP algorithm development and Cal/Val plans have commonality with those of SMOS, and for this reason there are shared activities and resources that can be utilized between the missions, including in situ networks, ancillary data sets, and long-term monitoring sites.

Njoku, Eni↗

Understanding the nature of the blazar CGRaBS J0211+1051

The source CGRaBS J0211+1051 (MG1 J021114+1051, z = 0.20) flared up on 2011 January 23 in high-energy γ-rays as reported by the Large Area Telescope (LAT) on board Fermi. This event was followed by increased activity at the UV, optical, and radio frequencies as detected by the observing facilities worldwide. The source also showed a high and variable optical polarization based on which it was proposed to be a low-energy peaked BL Lac object (LBL). The present work reports first comprehensive multi-wavelength study of this source using data in the radio, optical, UV, X- and γ-rays, and optical polarization. Using these multi-wavelength data on the source, we have estimated various parameters and verified its classification vis-a-vis blazar sequence. Multi-waveband light curves are used to discuss the flaring events of 2011 January in an attempt to address the nature of the source and pinpoint the possible physical processes responsible for the emission. The light curves show variations in the high-energy γ-rays to be correlated with X-ray, UV, and optical variations, perhaps indicating their co-spatial origin. Our optical data, quasi-simultaneous with UV (Swift-UVOT) and X-ray (Swift-XRT) data, enabled us to trace the low-energy (synchrotron) component of the spectral energy distribution (SED) for CGRaBS J0211+1051 for the first time. The SED shows the synchrotron peak to lie at ∼1.35 × 10{sup 14} Hz, confirming that CGRaBS J0211+1051 is an LBL. Some other parameters, such as the local magnetic field (∼5.93 G) and black hole mass (∼2.4 × 10{sup 8} M {sub ☉}), are also estimated which are in agreement with their typical values for the blazars. Based on the present study, identification of the Fermi/LAT source, 2FGL J0211.2+1050, with its BL Lac counterpart CGRaBS J0211+1051 is confirmed.

79 ASTRONOMY AND ASTROPHYSICS↗

HST photometry of the trapezium cluster

We have obtained images of 11 fields in the Trapezium cluster with the Planetary Camera (PC) of the Hubble Space Telescope (HST) in order to extend Herbig & Terndrup's (1986) study of this prototype, dense embedded cluster to fainter magnitudes than is possible from the ground. Using these images, we have identified 319 stars within an area of approximately 12 sq arc min corresponding roughly to a volume of approximately 0.065 cu pc assuming the cluster is approximately spherically symmetric. Our completeness limits for star identification in V-band and I-band images are V approximately = 20 and I(sub c) approximately = 19 respectively, corresponding to a mass limit of approximately 0.15 solar mass if the faintest stars have the same average A(sub v) as that estimated for the brighter stars in the cluster. We have compared the V versus V-I color-magnitude diagram derived from the HST photometry to new theoretical isochrones. Star formation in the Trapezium appears to be remarkably coeval, with greater than or = 80% of the stars having inferred ages less than 1 Myr. Over the somewhat limited mass range of the observations, there is no evidence for 'bimodal' star formation-the high- and low-mass stars appear to have the same ages. The sharp cores of the HST images and the small angular size of the PC pixels has allowed us to identify 35 new visual binaries in the cluster with separations from approximately 0.06 arc sec (approximately 26 AU) to approximately 1.0 arc sec (approximately 440 AU). For the range of binary separations that we are sensitive to, the observed binary frequency for the Trapezium is essentially identical to that estimated for field low-mass stars by Duquennoy & Mayor (1991). The most straightfoward inference from this result is that binaries in this separation are unlikely to be formed by a tidal capture process. We have also identified three stars which have associated compact nebulosity visible in the HST images. One of these star + nebulosity cases was previously identified by O'Dell, Wen, & Hu (1993)-these objects appear to form a class of objects whose circumstellar matter is being 'lit up', most likely by Theta(sup 1) Ori C, enabling the gas to be observable at both optical and radio wavelengths (Felli et al. 1993a, b). We provide a brief summary of the optical properties of the other radio sources which appear in our PC images.

Prosser, Charles F.↗

THE COMPLETE, TEMPERATURE-RESOLVED EXPERIMENTAL SPECTRUM OF ETHYL CYANIDE (CH{sub 3}CH{sub 2}CN) BETWEEN 210 AND 270 GHz

This paper reports the extension of a previously reported experimental method for the identification and characterization of astrophysical weeds in millimeter and submillimeter spectra to the widely used 210-270 GHz atmospheric window. At 300 K, these spectra contain contributions from approximately 40 vibrational states in addition to the cataloged ground state. The quantum mechanical analysis of such a large number of states would be a formidable challenge due to the complex interactions among these dense vibrational states. A new heterodyne receiver-based system is reported, as well as its intensity calibration. Results are presented in the standard astrophysical catalog format as well as our previously described point-by-point format that is effective for the characterization of blends. We also describe and validate an additional spectral synthesis approach, based on the much smaller line list catalog, which is useful in the blended line limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anomalous Thrust Production from an RF Test Device Measured on a Low-Thrust Torsion Pendulum

This paper describes the eight-day August 2013 test campaign designed to investigate and demonstrate viability of using classical magnetoplasmadynamics to obtain a propulsive momentum transfer via the quantum vacuum virtual plasma. This paper will not address the physics of the quantum vacuum plasma thruster, but instead will describe the test integration, test operations, and the results obtained from the test campaign. Approximately 30-50 micro-Newtons of thrust were recorded from an electric propulsion test article consisting primarily of a radio frequency (RF) resonant cavity excited at approximately 935 megahertz. Testing was performed on a low-thrust torsion pendulum that is capable of detecting force at a single-digit micronewton level, within a stainless steel vacuum chamber with the door closed but at ambient atmospheric pressure. Several different test configurations were used, including two different test articles as well as a reversal of the test article orientation. In addition, the test article was replaced by an RF load to verify that the force was not being generated by effects not associated with the test article. The two test articles were designed by Cannae LLC of Doylestown, Pennsylvania. The torsion pendulum was designed, built, and operated by Eagleworks Laboratories at the NASA Johnson Space Center of Houston, Texas. Approximately six days of test integration were required, followed by two days of test operations, during which, technical issues were discovered and resolved. Integration of the two test articles and their supporting equipment was performed in an iterative fashion between the test bench and the vacuum chamber. In other words, the test article was tested on the bench, then moved to the chamber, then moved back as needed to resolve issues. Manual frequency control was required throughout the test. Thrust was observed on both test articles, even though one of the test articles was designed with the expectation that it would not produce thrust. Specifically, one test article contained internal physical modifications that were designed to produce thrust, while the other did not (with the latter being referred to as the "null" test article). Test data gathered includes torsion pendulum displacement measurements which are used to calculate generated force, still imagery in the visible spectrum to document the physical configuration, still imagery in the infrared spectrum to characterize the thermal environment, and video imagery. Post-test data includes static and animated graphics produced during RF resonant cavity characterization using the COMSOL Multiphysics® software application. Excerpts from all of the above are included and discussed in this paper. Lessons learned from test integration and operations include identification of the need to replace manual control of the resonant cavity target frequency with an automated frequency control capability. Future test plans include the development of an automatic frequency control circuit. Test results indicate that the RF resonant cavity thruster design, which is unique as an electric propulsion device, is producing a force that is not attributable to any classical electromagnetic phenomenon and therefore is potentially demonstrating an interaction with the quantum vacuum virtual plasma. Future test plans include independent verification and validation at other test facilities.

Brady, David↗

OBSERVATIONS OF THE [HNCS]/[HSCN] RATIO IN Sgr B2 AND TMC-1: EVIDENCE FOR LOW-TEMPERATURE GAS-PHASE CHEMISTRY

Millimeter observations of isothiocyanic acid (HNCS) and its higher energy isomer, thiocyanic acid (HSCN), have been carried out toward Sgr B2 and TMC-1 using the 12 m telescope of the Arizona Radio Observatory. For both species, the J{sub Ka,Kc} = 8{sub 0,8} {yields} 7{sub 0,7} and 9{sub 0,9} {yields} 8{sub 0,8} transitions near 91-93 GHz and 103-106 GHz were mapped across a 6' x 3' region, centered near Sgr B2(M). Comparative mapping observations were also done for the J{sub Ka,Kc} = 4{sub 0,4} {yields} 3{sub 0,3} line of HNCO and HOCN near 84-87 GHz. In addition, the J{sub Ka,Kc} = 7{sub 0,7} {yields} 6{sub 0,6} and 8{sub 0,8} {yields} 7{sub 0,7} transitions of both HNCS and HSCN were detected in TMC-1, the first identification of either molecule in a cold, dark cloud. Emission from HNCS and HSCN was found to be extended over the Sgr B2 cloud, with a single velocity component and a linewidth of {approx}20-25 km s{sup -1}. Column densities derived for HSCN in Sgr B2 are typically N{sub tot} {approx} (0.2-1) x 10{sup 13} cm{sup -2}, with N{sub tot} {approx} (0.8-5) x 10{sup 13} cm{sup -2} for the more stable isomer, HNCS. In TMC-1, these species have similar column densities of (6-8) x 10{sup 10} cm{sup -2}. The [HNCS]/[HSCN] abundance ratio ranges from 2 to 7 in Sgr B2, with a value of {approx}1 in TMC-1. In contrast, the [HNCO]/[HOCN] ratio in Sgr B2 is {approx}110-250. Gas-grain chemical models do not reproduce the observed abundances of the sulfur isomers in either source. Given the energy difference of over 3200 K between HNCS and HSCN, these observations suggest that both molecules are produced from gas-phase, ion-molecule chemistry with a common precursor, HNCSH{sup +}. The oxygen analogs, in contrast, probably have a more complex chemical network, perhaps involving the H{sub 2}NCO{sup +} precursor, which preferentially leads to HNCO.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-EF-BRA-00: MR Basics I

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI (f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-01: NMR and Proton Density MRI of the 1D Patient

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-02: Longitudinal Proton Spin Relaxation and T1-Imaging

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗