Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIO REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

2004 Space Report: Environment and Strategy for Space Research at NATO's Research and Technology Organisation (RTO)

This report describes the motivation for and a strategy to enhance the NATO Research and Technology Organisation's (RTO) current space research effort to reflect NATO's growing military dependence on space systems. Such systems and services provided by these systems are critical elements of military operations. NATO uses space systems for operational planning and support, communication, radio navigation, multi-sensor and multi-domain demonstrations. Such systems are also used to promote regional stability. A quantitative analysis of work related to space in the NATO RTO showed that during the period of 1998 - 2004, 5% of the research pursued in the NATO RTO has been clearly focused on space applications. Challenging environmental and organizational barriers for increasing RTO space research were identified. In part, these include lack of sufficient space expertise representation on panels, the military sensitivity of space, current panel work loads and the need for specific technical recommendations from peers. A strategy for enhancing space research in the RTO is to create a limited-life Space Advisory Group (SAG) composed of Space Expert Consultants who are panel members with appropriate expertise and additional expertise from the nations. The SAG will recommend and find support in the nations for specific technical activities related to space in the areas of Space Science, Remote Sensing Data Analysis, Spacecraft Systems, Surveillance and Early Warning, Training and Simulation and Policy. An RTO Space Advisory Group will provide an organizational mechanism to gain recognition of RTO as a forum for trans-Atlantic defence space research and to enhance space research activities.

Woods-Vedeler, Jessica A.↗

X-rays and gamma-rays from accretion flows onto black holes in Seyferts and X-ray binaries

Observations and theoretical models of X-ray/gamma ray spectra of radio quiet Seyfert galaxies and Galactic black hole candidates are reviewed. The spectra from these objects share the following characteristics: an underlying power law with a high energy cutoff above 200 keV; a Compton reflection component with a Fe K alpha line, and a low energy absorption by intervening cold matter. The X-ray energy spectral index, alpha, is typically in the range between 0.8 and 1 in Seyfert spectra, and that of the hard state spectra of the black hole candidates Cygnus X-1 and GX 339-4 is typically between 0.6 and 0.8. The Compton reflection component corresponds with cold matter covering a solid angle of between 0.8pi and 2pi as seen from the X-ray source. The broadband spectra of both classes of sources are well fitted by Compton upscattering of soft photons in thermal plasma. The fits yield a thermal plasma temperature of 100 keV and the Thomson optical depth of 1. All the spectra presented are cut off before the electron rest energy 511 keV, indicating that electron/positron pair production is an important process.

Zdziarski, Andrzej A.↗

Earth-based remote sensing of planetary surfaces and atmospheres at radio wavelengths

Two reasons for remote sensing from the Earth are given: (1) space exploration, particularly below the surfaces or underneath cloud layers, is limited to only a very few planets; and (2) a program of regular monitoring, currently impractical with a limited number of space probes, is required. Reflected solar and nonthermal radiation are discussed. Relativistic electrons, trapped in large magnetospheres on Saturn and Jupiter, are discussed. These electrons produce synchrotron radiation and also interact with the ionosphere to produce bursts of low frequency emission. Because most objects are black-bodies, continuum radiometry is emphasized. Spectroscopic techniques and the measurement of nonthermal emission are also discussed.

Dickel, J. R.↗

Radio properties of the highly polarized, quiescent quasar OI 287

The highly polarized, quiescent quasar OI 287 has been observed with high resolution at 2 cm and 6 cm in an effort to determine the origin of some of the object's peculiar properties. The results seem to rule out the classification of OI 287 as a blazar. Extrapolation of the radio core spectrum to midinfrared wavelengths fails to predict the infrared flux by at least an order of magnitude. This supports the conclusion that the infrared emission and the radio emission do not originate in the same synchrotron-emitting component. The high optical polarization could be related to possible broad absorption lines in the unobserved UV regime, or it could be caused by reflection into the line of sight by scattering agents distributed in a thin disk.

Ulvestad, James S.↗

Fiber-Optic Frequency-Transfer Link

System for distribution of 100-MHz reference signal features transmission through optical fiber to station 22 km away and stabilization of frequency by radio frequency phase-conjugation method. Compensates for variations in phase (caused mostly by changes in temperature along optical fiber) of signal arriving at remote station. Involves measurement and control of phases of transmitted and reflected signals at reference station to obtain reference phase at remote station.

Primas, L. E.↗

Ionosphere-reflected propagation

The predictability of those ionospheric parameters relevant to ionosphere-reflected communications is considered along with their optimum utilization. Several excellent original articles and review papers which have been published from time to time dealing with the long term and short term forecasting of ionospheric parameters, radio systems, and modelling needs for ionospheric communications, are covered.

Reddy, B. M.↗

Investigations of Remote Plasma Irregularites by Radio Sounding: Applications of the Radio Plasma Imager on IMAGE

The Radio Plasma Imager (RPI) on the Imager for Magnetopause-to-Aurora Global Exploration (IMAGE) mission operates like a radar by transmitting and receiving coherent electromagnetic pulses. Long-range echoes of electromagnetic sounder waves are reflected at remote plasma cutoffs. Thus, analyses of RPI observations will yield the plasma parameters and distances to the remote reflection points. These analyses assume that the reflecting plasma surfaces are cold and are sufficiently smooth that they effectively behave as plane mirrors to the incoming sounder waves, i.e., that geometric optics can be used. The RPI will employ pulse compression and spectral integration techniques, perfected in ground-based ionospheric digital sounders, in order to enhance the signal-to-noise ratio in long-range magnetospheric sounding. When plasma irregularities exist in the remote magnetospheric plasmas that are being probed by the sounder waves, echo signatures may become complicated. Ionospheric sounding experience indicates that while topside sounding echo strengths can actually be enhanced by the presence of irregularities, ground-based sounding indicates that coherent detection techniques can still be employed. In this paper we investigate the plasma conditions that will allow coherent signals to be detected by the RPI and the signatures to be expected, such as scattering and plasma resonances, in the presence of multi-scale irregularities, may possibly have on RPI signals. Sounding of irregular plasma structures in the plasmasphere, plasmapause and magnetopause are also discussed.

Fung, Shing F.↗

Delay Tolerant, Radio Frequency Identification (RFID )-enabled Sensing

Radio Frequency Identification (RFID) technology offers a completely passive method to transmit fixed data sequences from an RFID tag, which typically doesn’t have its own power supply, to an interrogator. Radio frequency (RF) energy harvested from the interrogator is rectified by the tag and used to charge an integrated circuit (IC). The IC then modulates the received signal with the data stored on the tag and reflects the energy back to the interrogator. RFID has seen great proliferation in terrestrial inventory management applications, and it has recently made the jump to spaceflight applications onboard the International Space Station, augmenting an existing optical bar‐code infrastructure for tracking supplies. A number of advanced automated logistics management (ALM) concepts employing RFID are currently being developed and evaluated, including so‐called “smart” shelves, cubbies, and trash receptacles using low‐power, embeddable RFID interrogators. An infrastructure where both crew members and robotic assistants, such as autonomous free flyers, are similarly equipped with small RFID interrogators seems likely. It therefore behooves us to consider extending this infrastructure beyond ALM to applications such as low power, embedded sensing. Typically, data on an RFID tag can only be written by an RFID interrogator, using interrogator energy. In recent years, however, a few efforts have focused on using that energy to drive data acquisition from the tag IC, allowing the tag to modify its stored data sequence with sensor data before replying to an interrogator. In this way, the tag can act as a completely passive sensing device. One problem exists with this approach, however: the tag cannot gather data when an interrogator is not present. Thus, strictly passive RFID sensing tags cannot gather data at regular intervals, in the manner of a typical wireless sensor network, without careful, and impractical, planning of mobile interrogator movements. To address this shortcoming, we look to a recent advance in RFID technology which allows an external microprocessor to power the tag IC and write directly into its RFID memory using a wired serial interface. In this paradigm, data gathering is driven by a small, on‐board power supply (using batteries or harvested energy), and data transfer is provided passively through the RFID interrogation service. Since communication typically consumes the lion’s share of power in WSNs, such a technique has the potential to enable extremely long‐lived, embedded wireless sensing when used with extremely low‐current microcontrollers. Since the communication channel is only open when an interrogator is present and actively interrogating the RFID sensing tag, transport of periodically‐sampled sensor data presents itself as a delay/disruption‐tolerant networking (DTN) problem. In this paper, we present the design of a DTN‐like overlay on the common EPC Global, Class 1, Generation 2 RFID standard. This overlay allows seamless, guaranteed data transfer using the EPC Global protocol, supporting extremely low‐power, embedded sensing using an infrastructure likely to be already in place for ALM applications. We evaluate a prototype implementation of a complete end‐to‐end system using a robotic RFID interrogation agent, and we present future directions for the development of this sensing technique.

Raymond S. Wagner↗

The state of the ionosphere above Alma Ata

The basic patterns are described in the behavior of critical frequencies and minimum effective heights of the ionosphere's reflecting E, F1, and F2 layers, according to ionospheric recorder measurements from 1943 to 1967. The variations of critical frequencies and virtual heights are compared with the relative sunspot numbers and the flux of the sun's radio emission at 10.7 cm.

Rudina, M. P.↗

Recovery of a Charred Painting Using Atomic Oxygen Treatment

A noncontact method is described which uses atomic oxygen to remove soot and char from the surface of a painting. The atomic oxygen was generated by the dissociation of oxygen in low pressure air using radio frequency energy. The treatment, which is an oxidation process, allows control of the amount of material to be removed. The effectiveness of char removal from half of a fire-damaged oil painting was studied using reflected light measurements from selected areas of the painting and by visual and photographic observation. The atomic oxygen was able to effectively remove char and soot from the treated half of the painting. The remaining loosely bound pigment was lightly sprayed with a mist to replace the binder and then varnish was reapplied. Caution should he used when treating an untested paint medium using atomic oxygen. A representative edge or corner should he tested first in order to determine if the process would be safe for the pigments present. As more testing occurs, a greater knowledge base will be developed as to what types of paints and varnishes can or cannot be treated using this technique. With the proper precautions, atomic oxygen treatment does appear to be a technique with great potential for allowing very charred, previously unrestorable art to be salvaged.

Rutledge, Sharon K.↗

Expanding Hardware-in-the-Loop Formation Navigation and Control with Radio Frequency Crosslink Ranging

The Formation Flying Testbed (FFTB) at the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) provides a hardware-in-the-loop test environment for formation navigation and control. The facility continues to evolve as a modular, hybrid, dynamic simulation facility for end-to-end guidance, navigation, and control (GN&C) design and analysis of formation flying spacecraft. The core capabilities of the FFTB, as a platform for testing critical hardware and software algorithms in-the-loop, are reviewed with a focus on recent improvements. With the most recent improvement, in support of Technology Readiness Level (TRL) 6 testing of the Inter-spacecraft Ranging and Alarm System (IRAS) for the Magnetospheric Multiscale (MMS) mission, the FFTB has significantly expanded its ability to perform realistic simulations that require Radio Frequency (RF) ranging sensors for relative navigation with the Path Emulator for RF Signals (PERFS). The PERFS, currently under development at NASA GSFC, modulates RF signals exchanged between spacecraft. The RF signals are modified to accurately reflect the dynamic environment through which they travel, including the effects of medium, moving platforms, and radiated power.

Mitchell, Jason W.↗

Concentration of off-axis radiation by solar concentrators for space power

Off-axis radiation is radiation from any direction not parallel to the axis of the solar concentrator. It will be reflected to regions other than the focus of the parabolic concentrator and possibly concentrated there. Four types of off-axis radiation are discussed. These are: (1) small off-axis angles during walk-off; (2) large off-axis angles; (3) an extended off-axis source such as Earth albedo; and (4) miscellaneous off-axis sources including radio frequency sources and local point sources. A previous analytical study used a computer code named PIXEL to predict concentration of off-axis radiation and a previous experimental study used an 11-m diameter multifaceted dish concentrator to validate the PIXEL analysis. The PIXEL code was limited in that it represented concentration by an ideal parabolic reflector of light from a point source. Another code named OFFSET has been developed to represent the solar concentrator being developed for Space Station Freedom. It is a detailed, ray tracing model which represents 50 ray originating points on the Sun and reflections from 10 points on each of the 456 concentrator facets. Results of this code are generally similar to the PIXEL results although there are small differences due to the more detailed representations of the Sun and concentrator that were used in the OFFSET code.

Jefferies, Kent S.↗

A study of the microstructure and optical properties of thin lead-dielectric cermet films

A transmission electron microscopy study involving direct and replicating techniques is directed to a definition of the microstructure of radio frequency-sputtered, thin lead-dielectric cermet films. Once defined, this microstructure is used to obtain theoretical film refractive indices. The Maxwell Garnett theory provides a basis for the theoretical results. Measurements of film transmission and reflectivity are used to obtain rough experimental values for film refractive indices by the Tekucheva method. More exact values are obtained via ellipsometry. The rough Tekucheva values are used to determine the range over which computer calculations interpreting the ellipsometric results must be made. This technique yields accurate values for the film refractive indices.

Owen, R. B.↗

Crystal motion measurement by means of satellite techniques

A system for monitoring precursory crustal motions is presented. It involves a set of automated corner reflector stations tracked by means of a laser operating in the Geopause satellite. It is possible to range some three times during every Geopause pass to each of the sites in such an ensemble, weather permitting. One centimeter range data gathered during a quarter of a year can yield position component accuracies of the order of a couple of centimeters. A laser beam of a tenth of a milliradian in diameter would, illuminate a single station in such an array. A broader beam would generate reflections from several sites, yielding overlapping data. A chain or pattern of such overlapping regions can strengthen the solution for site positions. Pressure, temperature and humidity gauges can provide refraction correction data. Turnaround transponders interrogated by the Geopause radio tracking system can furnish corresponding data in excessively cloudy regions.

Siry, J. W.↗

Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system's eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware. Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to-noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.

Ellis, Tayera↗

Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system’s eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware.Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.Additionally, topics of what was learned and smaller tasks given at White Sands Test Facility (WSTF) will be discussed. All statements in this paper are newly gained knowledge of what I have learned, observed, and have done while at WSTF.

Ellis, Tayera↗

Point Simulator for Synthetic-Aperture Radar

Reflection from point target imitated electronically. SAR simulator produces amplitude- and phase-modulated 60-MHz signal that resembles SAR return of point scatterer. Designed to test integrated optical SAR receivers, simulator applies phase modulation necessary to turn radio-frequency pulse train into electronic equivalent of unfocused radar image of target.

Psaltis, D.↗