Search NASA⌕ Search

SEARCH · Search NASA

Results for “ROAD CONDITIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Remaining Sites Verification Package for the 128-F-2, 100-F Burning Pit Waste Site, Waste Site Reclassification Form 2008-031

The 128-F-2 waste site consisted of multiple burn and debris filled pits located directly east of the 107-F Retention Basin and approximately 30.5 m east of the northeast corner of the 100-F Area perimeter road that runs along the riverbank. The burn pits were used for incinerating nonradioactive, combustible materials from 1945 to 1965. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The current site conditions achieve the remedial action objectives and the corresponding remedial action goals established in the Remaining Sites ROD. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

100-F Burning Pit↗

Improving Efficiency of Off-Road Vehicles by Novel Integration of Electric Machines and Advanced Combustion Engines

Modern off-road equipment will increasingly rely on electrified implements that will deliver precision control with a smaller footprint than hydraulics. The primary energy converter, however, will be an onboard reciprocating internal combustion engine because of the power density of hydrocarbon fuels in comparison to electrical energy storage and the remote locations where much of this equipment is deployed. Adding energy storage and electric machines creates opportunities to improve efficiency while reducing emissions. This program investigated approaches to take advantage of the extra flexibility that an enhanced electrical system to enable high-efficiency, low-emissions combustion technologies. The current program evaluated hybridization of both the torque application and air-handling systems to maximize efficiency while minimizing cost. This program designed, analyzed and tested a hybrid off-road vehicle consisting of a series electric powertrain with energy storage, an electrified air system, and a 33% downsized diesel engine. Detailed comparisons were made between the base powertrain and the developed powertrain using powertrain simulations, engine testing, and vehicle testing. The key results of the study are: • The resulting vehicle reduces fuel consumption by 5% to 15% at equal productivity. The primary improvements were due to recovery of regenerative braking losses for cycles where large transients are encountered. • The electrified air system was an enabler to allow engine downsizing. This was most important for duty-cycles where the engine primarily operated at moderate loads and had few low speed high torque conditions. • Engine level improvements showed re-optimization of the powertrain is possible when electrified air handing is available. Increased exhaust gas recirculation and advanced injection timing allowed up to a 15% reduction in brake specific fuel consumption at equal NOx and transient response. Compared to the larger engine, the downsized engine achieves up to an 18% reduction in brake specific fuel consumption over the non-road transient cycle. • The life cycle analysis and total cost of ownership study showed that the hybrid powertrain has the potential to reduce 5-year CO2 and total cost of ownership by ~6% over the baseline vehicle. The results also indicated that a pure battery electric vehicle is not feasible in this application and is likely to increase the CO2 emissions due to the CO2 from battery production. A hybrid powertrain with low carbon fuels shows the potential to substantially reduce CO2 and total cost of ownership.

02 PETROLEUM↗

Spinning Reserve From Hotel Load Response: Initial Progress

This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Macro Analysis to Estimate Electric Vehicles Fast-Charging Infrastructure Requirements in Small Urban Areas

Electric vehicles (EVs) are known to reduce emissions and fossil fuel dependency. However, the limited range, long charging time, and inadequate charging infrastructure have hampered the adoption of EVs. The current EV charging infrastructure planning studies and tools require detailed information, extensive resources, and skills that can be a significant barrier to urban areas for finding the required charging infrastructure to support a targeted EV market share. This study generates regression models to estimate the number of direct current fast charging stations and the chargers to support the EV charging demand for urban areas. These models provide macro-level estimates of the required infrastructure investment in urban areas, which can be easily implemented by policy-makers and city planners. This study incorporates data obtained from applying a disaggregate optimization-based charger placement model, developed recently by the same authors, for multiple case studies to generate the required data to calibrate the macro-level models, in the state of Michigan. This simulated data set includes the number of charging stations and chargers for each market share, technology advancement scenario, and the transportation network topology. The results show that the number of charging stations reduces with battery size and charging power and increases with EV market share and the road network lane length. The number of chargers reduces with charging power, whereas it increases with battery size, EV market share, and vehicle miles traveled in the system. The model developed here can be applied to any state having urban characteristics and weather conditions similar to Michigan.

Engineering↗

Neuroevolution Application to Collaborative and Heuristics-Based Connected and Autonomous Vehicle Cohort Simulation at Uncontrolled Intersection

Artificial intelligence is gaining tremendous attractiveness and showing great success in solving various problems, such as simplifying optimal control derivation. This work focuses on the application of Neuroevolution to the control of Connected and Autonomous Vehicle (CAV) cohorts operating at uncontrolled intersections. The proposed method implementation’s simplicity, thanks to the inclusion of heuristics and effective real-time performance are demonstrated. The resulting architecture achieves nearly ideal operating conditions in keeping the average speeds close to the speed limit. It achieves twice as high mean speed throughput as a controlled intersection, hence enabling lower travel time and mitigating energy inefficiencies from stop-and-go vehicle dynamics. Low deviation from the road speed limit is hence continuously sustained for cohorts of at most 50 m long. This limitation can be mitigated with additional lanes that the cohorts can split into. The concept also allows the testing and implementation of fast-turning lanes by simply replicating and reconnecting the control architecture at each new road crossing, enabling high scalability for complex road network analysis. The controller is also successfully validated within a high-fidelity vehicle dynamic environment, showing its potential for driverless vehicle control in addition to offering a new traffic control simulation model for future autonomous operation studies.

Jacquelin, Frederic (ORCID:0000000183154344)↗

Deadly Heat Stress to Become Commonplace Across South Asia Already at 1.5°C of Global Warming

South Asia (SA) is one of those hotspots where earliest exposure to deadly wet-bulb temperatures (Tw >35°C) is projected in warmer future climates. Here we find that even today parts of SA experience the upper limits of labor productivity (Tw >32°C) or human survivability (Tw >35°C), indicating that previous estimates for future exposure to Tw-based extremes may be conservative. Our results show that at 2°C global warming above pre-industrial levels, the per person exposure approximately increases by 2.2 (2.7) folds for unsafe labor (lethal) threshold compared to the 2006–2015 reference period. Limiting warming to 1.5°C would avoid about half that impact. The population growth under the middle-of-the-road socioeconomic pathway could further increase these exposures by a factor of ~2 by the mid-century. These results indicate an imminent need for adaptation measures, while highlighting the importance of stringent Paris-compatible mitigation actions for limiting future emergence of such conditions in SA.

58 GEOSCIENCES↗

Experimental validation of the Finite Element-Multibody model of a cryomodule during road transportation

The present activity aims to test the Transportation Tooling (TT) designed for the Cryomodule SSR1 at Fermilab facilities. The tests consisted of road transportation trials of a cryomodule sub-assembly, suspended on a truck using the designed TT. The truck drove along a path inside Fermilab facilities. The trial was performed at an approximate speed of about 25 km/h, which is close to the transportation conditions of the complete Cryomodule. Several accelerometers were mounted on the Transportation Tooling frame and the cryomodule sub-assembly. This allowed comparing the vibration behavior of the inner frame of the TT with the solicitation coming from the truck loading bed, to assess the filtering capabilities of the tooling. Also, the acceleration of the main components could be monitored during the whole transportation, to obtain a validation of the developed numerical model.

43 PARTICLE ACCELERATORS↗

The Successful Transfer of Space Derived Convergent Spray: An Application for Industrial Roof Coatings and Interstate Bridge Repair

A partnership was formed between the National Aeronautics and Space Administration (NASA), the Environmental Protection Agency (EPA), and United Technologies USBI Company to develop, demonstrate, and evaluate a technology that uses a solventless spray process for depositing a lightweight, highly filled roof coating on low-sloped commercial roofs. Although the levels of volatile organic compound (VOC) emissions from industrial roof coating's and paint operations have been reduced in recent years, this partnership,was an effort to further reduce VOC emission levels and to also demonstrate the use of reclaimed automobile tire rubber as a filler material in roof coating systems. Different materials and coatings were evaluated and tested before the final selection used to coat the roofs of two small buildings at NASA's Marshall Space Flight Center during fiscal year 1997. The project successfully leveraged the investment of EPA, NASA and private sector resources to demonstrate a pre-commercial roofing coating process. This process utilizes the Convergent Spray Technologies process, which was initially developed by USBI to apply highly-filled, thermal protection coatings to the Space Shuttle Solid Rocket Boosters. A second partnership between the NASA, Federal Highway Administration, Alabama Department of Transportation and USBI Company was formed to develop and demonstrate the Convergent Spray Technology as a method of applying a skid resistant coating to interstate roads and concrete bridge decking's. Again, different materials and coatings were evaluated and tested before the final selection of ground flint and resin. Two field demonstrations were performed during fiscal year 1997 for the purpose of evaluating the coating system under actual highway conditions. These coatings were applied on Interstate 65 near Huntsville Alabama, and in the Mobile Bankhead tunnel. The system performed this task without the use of harmful solvents, and accomplished the process in a single application. This project successfully leveraged the investment of NASA, Federal Highway Administration, the Alabama Department of Transportation, and private sector funding.

McMillan, Vernotto C.↗

From consultation to deliberation? Tracing deliberative norms in EIA frameworks in Swedish roads planning

This paper presents the results of an analysis of deliberative norms in the framework for Environmental Impact Assessment (EIA) in roads planning in Sweden. The more specific question is how this framework has responded to the shift towards more deliberative approaches to planning and decision making, advocated in planning theory and policy literature over the last decade. The analysis, which compares the current framework and guidance with an earlier iteration, identifies a shift towards deliberation; deliberative norms are present, and even dominate recent guidance. However, an instrumental norm permeates both the former and the current guidance, suggesting that even as a language of consultation is replaced by one of deliberation, the intention remains to secure and legitimise a smooth development pathway. Evidence from interviews with professionals working in the Swedish EIA system highlights the difficulties of navigating these uncertainties in practice. By opening up critical analysis of deliberative norms as they shape the conditions for practice, this study contributes to the continuous development of planning practice, by supporting a more normatively reflexive approach to framework-design.

54 ENVIRONMENTAL SCIENCES↗

GIS Visualization of Transportation Energy Consumption

Transportation is witnessing unprecedented transformation, where emerging technologies are disrupting the way we travel. Be it sharing economy, or micro-mobility, the landscape of urban transportation is undergoing a much-needed paradigm shift. In order to capture and model these shifts, researchers need to be agile in their studies of the current and future transportation landscape. The need for agility in turn calls for sophisticated, intuitive, and reliable means to visualize and share transportation data. Travel is inherently spatial, so methods of visualizing transportation information should also be rooted in spatial analysis. Geographic Information Systems (GIS) are the premier technological framework to analyze and display spatial data. GIS tools have been used in the past to depict flow of vehicles, and display of network conditions (speed, congestion, etc.). However, in an ever-changing technological landscape, spanning advancements in vehicle as well as information systems, depicting vehicle flows falls short of providing a comprehensive picture of the impact these advancements have on travel related energy consumption. To address this issue, this research effort presents a web-based mapping application to visualize how travel related energy flows across a city. The application is being developed by National Renewable Energy Laboratory researchers to integrate various transportation energy consumption models within a GIS schema. This has the goal of enabling rapid analysis of energy impacts of the dramatically evolving transportation environment. The application is being developed using a Python framework for ArcGIS Online. Using road network data from the City of Columbus, Ohio and traffic data from CATT Laboratory's Regional Integrated Transportation Information System, transportation energy consumption will be modeled at a macro level. The application aims to provide highly accurate data while still maintaining the flexibility needed to adapt the model when new technologies arise. The methodology presented through this effort is expected to provide insights into how light-duty vehicles use energy on a large scale based on the road network they use. The application will also provide data exports to enable sharing and collaboration. " need for agility in turn calls for sophisticated, intuitive, and reliable means to visualize and share transportation data. Travel is inherently spatial, so methods of visualizing transportation information should also be rooted in spatial analysis. Geographic Information Systems (GIS) are the premier technological framework to analyze and display spatial data. GIS tools have been used in the past to depict flow of vehicles, and display of network conditions (speed, congestion, etc.). However, in an ever-changing technological landscape, spanning advancements in vehicle as well as information systems, depicting vehicle flows falls short of providing a comprehensive picture of the impact these advancements have on travel related energy consumption. To address this issue, this research effort presents a web-based mapping application to visualize how travel related energy flows across a city. The application is being developed by National Renewable Energy Laboratory researchers to integrate various transportation energy consumption models within a GIS schema. This has the goal of enabling rapid analysis of energy impacts of the dramatically evolving transportation environment. The application is being developed using a Python framework for ArcGIS Online. Using road network data from the City of Columbus, Ohio and traffic data from CATT Laboratory's Regional Integrated Transportation Information System, transportation energy consumption will be modeled at a macro level. The application aims to provide highly accurate data while still maintaining the flexibility needed to adapt the model when new technologies arise. The methodology presented through this effort is expected to provide insights into how light-duty vehicles use energy on a large scale based on the road network they use. The application will also provide data exports to enable sharing and collaboration.

33 ADVANCED PROPULSION SYSTEMS↗

Neural Network-Based Electric Vehicle Range Prediction for Smart Charging Optimization

Range prediction is a standard feature in most modern road vehicles, allowing drivers to make informed decisions about when to refuel. Most vehicles make range predictions through data- or model-driven means, monitoring the average fuel consumption rate or using a tuned vehicle model to predict fuel consumption. The uncertainty of future driving conditions makes the range prediction problem challenging, particularly for less pervasive battery electric vehicles (BEV). Most contemporary machine learning-based methods attempt to forecast the battery SOC discharge profile to predict vehicle range. In this work, we propose a novel approach using two recurrent neural networks (RNNs) to predict the remaining range of BEVs and the minimum charge required to safely complete a trip. Each RNN has two outputs that can be used for statistical analysis to account for uncertainties; the first loss function leads to mean and variance estimation (MVE), while the second results in bounded interval estimation (BIE). These outputs of the proposed RNNs are then used to predict the probability of a vehicle completing a given trip without charging, or if charging is needed, the remaining range and minimum charging required to finish the trip with high probability. Training data was generated using a low-order physics model to estimate vehicle energy consumption from historical drive cycle data collected from medium-duty last-mile delivery vehicles. Here, the proposed method demonstrated high accuracy in the presence of day-to-day route variability, with the root-mean-square error (RMSE) below 6% for both RNN models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical experiments on the climatic sensitivity of an atmospheric hydrologic cycle

It is shown for an intermediate numerical model that fractional cloudiness and relative humidity decrease with increasing temperature. The fractional cloudiness decreases at a rate about 1 per deg K. This occurs in spite of an increase in the evaporation, water transport, condensation, precipitation and cloud water content with increasing temperature. These results are quite similar to those found from models with more highly parameterized clouds, notably the NCAR model. The fractional cloudiness in this model is measured by the fractional coverage of total cloud water and the fractional coverage of positive condensation, in addition to the relative humidity. It is also shown that some of the characteristics of a temperate climate can be simulated in an intermediate numerical model with periodic, antisymmetric and symmetric boundary conditions on an f plane. Intermediate models of this sort may therefore be useful to investigate general questions about the earth's hydrologic cycle on climatic space and time scales

Roads, J. O.↗

Crash Test of Three Cessna 172 Aircraft at NASA Langley Research Center's Landing and Impact Research Facility

During the summer of 2015, three Cessna 172 aircraft were crash tested at the Landing and Impact Research Facility (LandIR) at NASA Langley Research Center (LaRC). The three tests simulated three different crash scenarios. The first simulated a flare-to-stall emergency or hard landing onto a rigid surface such as a road or runway, the second simulated a controlled flight into terrain with a nose down pitch on the aircraft, and the third simulated a controlled flight into terrain with an attempt to unsuccessfully recover the aircraft immediately prior to impact, resulting in a tail strike condition. An on-board data acquisition system captured 64 channels of airframe acceleration, along with acceleration and load in two onboard Hybrid II 50th percentile Anthropomorphic Test Devices, representing the pilot and co-pilot. Each test contained different airframe loading conditions and results show large differences in airframe performance. This paper presents test methods used to conduct the crash tests and will summarize the airframe results from the test series.

Littell, Justin D.↗

Geopolymer Lunar Concrete under Reduced-Pressure Curing and Vacuum Exposure

Geopolymer concrete has emerged as a promising material for constructing habitats, roads, landing pads, and other necessary infrastructure on the lunar surface. Proper in-situ resource utilization (ISRU) is an important aspect of any candidate lunar construction material. Geopolymer concrete is effective at ISRU, as the lunar regolith can be used in the “as found” condition and mixed with an alkaline solution, such as sodium silicate and sodium hydroxide, which could also be mostly produced in-situ. It is envisioned that any concrete material on the lunar surface would be deposited with additive manufacturing techniques and would require a temporary environmental enclosure to mitigate the harsh lunar environment during construction and curing, such as pressure and temperature. Data are needed to set a benchmark for the conditions to be achieved within the deployable environmental enclosure during printing, as well as the resultant material properties after the enclosure is removed. This novel study investigated the influence of reduced atmospheric pressures during the initial curing period on the compressive strength of geopolymer lunar concrete created with two types of lunar regolith simulant. The simulants used in the study represent the regolith for the lunar mare (OPRL2N) and lunar highlands (OPRH2N) regions. Results show a noticeable decline in strength with a reduction in pressure and visible degradation. After the deployable environmental enclosure is removed from the printed segment of infrastructure on the lunar surface, it would then be exposed to the harsh vacuum environment. To understand the importance of curing time required within the deployable enclosure before it is removed, samples were cast and cured for different lengths of time and then exposed to a vacuum chamber capable of achieving 100 mTorr. Control samples were also cast at the same time but left in a standard laboratory environment after curing. The weight change and compressive strength as a function of time in the vacuum chamber were monitored for up to 56 days. The results showed that exposure to the vacuum limits further reaction and strength gain in comparison to control samples left in the laboratory environment. This research is in strong alignment with the 2020 NASA Technology Taxonomy materials area (12.1) and the in-situ resource utilization area (7.1), as it provides necessary data on the geopolymer lunar concrete material to support safe and sustainable options for maintaining a human presence on the Moon.

Moon to Mars Planetary Autonomous Construction Tec↗

Technical Safety Requirements for the Waste Storage Facilities

This document contains Technical Safety Requirements (TSR) for the Radioactive and Hazardous Waste Management (RHWM) WASTE STORAGE FACILITIES, which include Area 625 (A625) and the Decontamination and Waste Treatment Facility (DWTF) Storage Area at Lawrence Livermore National Laboratory (LLNL). The TSRs constitute requirements regarding the safe operation of the WASTE STORAGE FACILITIES. These TSRs are derived from the 'Documented Safety Analysis for the Waste Storage Facilities' (DSA) (LLNL 2008). The analysis presented therein determined that the WASTE STORAGE FACILITIES are low-chemical hazard, Hazard Category 2 non-reactor nuclear facilities. The TSRs consist primarily of inventory limits and controls to preserve the underlying assumptions in the hazard and accident analyses. Further, appropriate commitments to safety programs are presented in the administrative controls sections of the TSRs. The WASTE STORAGE FACILITIES are used by RHWM to handle and store hazardous waste, TRANSURANIC (TRU) WASTE, LOW-LEVEL WASTE (LLW), mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL as well as small amounts from other U.S. Department of Energy (DOE) facilities, as described in the DSA. In addition, several minor treatments (e.g., size reduction and decontamination) are carried out in these facilities. The WASTE STORAGE FACILITIES are located in two portions of the LLNL main site. A625 is located in the southeast quadrant of LLNL. The A625 fenceline is approximately 225 m west of Greenville Road. The DWTF Storage Area, which includes Building 693 (B693), Building 696 Radioactive Waste Storage Area (B696R), and associated yard areas and storage areas within the yard, is located in the northeast quadrant of LLNL in the DWTF complex. The DWTF Storage Area fenceline is approximately 90 m west of Greenville Road. A625 and the DWTF Storage Area are subdivided into various facilities and storage areas, consisting of buildings, tents, other structures, and open areas as described in Chapter 2 of the DSA. Section 2.4 of the DSA provides an overview of the buildings, structures, and areas in the WASTE STORAGE FACILITIES, including construction details such as basic floor plans, equipment layout, construction materials, controlling dimensions, and dimensions significant to the hazard and accident analysis. Chapter 5 of the DSA documents the derivation of the TSRs and develops the operational limits that protect the safety envelope defined for the WASTE STORAGE FACILITIES. This TSR document is applicable to the handling, storage, and treatment of hazardous waste, TRU WASTE, LLW, mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste received or generated in the WASTE STORAGE FACILITIES. Section 5, Administrative Controls, contains those Administrative Controls necessary to ensure safe operation of the WASTE STORAGE FACILITIES. Programmatic Administrative Controls are in Section 5.6.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical Safety Requirements for the Waste Storage Facilities

This document contains Technical Safety Requirements (TSR) for the Radioactive and Hazardous Waste Management (RHWM) WASTE STORAGE FACILITIES, which include Area 625 (A625) and the Decontamination and Waste Treatment Facility (DWTF) Storage Area at Lawrence Livermore National Laboratory (LLNL). The TSRs constitute requirements regarding the safe operation of the WASTE STORAGE FACILITIES. These TSRs are derived from the Documented Safety Analysis for the Waste Storage Facilities (DSA) (LLNL 2009). The analysis presented therein determined that the WASTE STORAGE FACILITIES are low-chemical hazard, Hazard Category 2 non-reactor nuclear facilities. The TSRs consist primarily of inventory limits and controls to preserve the underlying assumptions in the hazard and accident analyses. Further, appropriate commitments to safety programs are presented in the administrative controls sections of the TSRs. The WASTE STORAGE FACILITIES are used by RHWM to handle and store hazardous waste, TRANSURANIC (TRU) WASTE, LOW-LEVEL WASTE (LLW), mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL as well as small amounts from other U.S. Department of Energy (DOE) facilities, as described in the DSA. In addition, several minor treatments (e.g., size reduction and decontamination) are carried out in these facilities. The WASTE STORAGE FACILITIES are located in two portions of the LLNL main site. A625 is located in the southeast quadrant of LLNL. The A625 fenceline is approximately 225 m west of Greenville Road. The DWTF Storage Area, which includes Building 693 (B693), Building 696 Radioactive Waste Storage Area (B696R), and associated yard areas and storage areas within the yard, is located in the northeast quadrant of LLNL in the DWTF complex. The DWTF Storage Area fenceline is approximately 90 m west of Greenville Road. A625 and the DWTF Storage Area are subdivided into various facilities and storage areas, consisting of buildings, tents, other structures, and open areas as described in Chapter 2 of the DSA. Section 2.4 of the DSA provides an overview of the buildings, structures, and areas in the WASTE STORAGE FACILITIES, including construction details such as basic floor plans, equipment layout, construction materials, controlling dimensions, and dimensions significant to the hazard and accident analysis. Chapter 5 of the DSA documents the derivation of the TSRs and develops the operational limits that protect the safety envelope defined for the WASTE STORAGE FACILITIES. This TSR document is applicable to the handling, storage, and treatment of hazardous waste, TRU WASTE, LLW, mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste received or generated in the WASTE STORAGE FACILITIES. Section 5, Administrative Controls, contains those Administrative Controls necessary to ensure safe operation of the WASTE STORAGE FACILITIES. Programmatic Administrative Controls are in Section 5.4.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Historical Evaluation of the U15 Complex, Nevada National Security Site, Nye County, Nevada

This report presents a historical evaluation of the U15 Complex on the Nevada National Security Site (NNSS) in southern Nevada. The work was conducted by the Desert Research Institute at the request of the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office and the U.S. Department of Defense, Defense Threat Reduction Agency. Three underground nuclear tests and two underground nuclear fuel storage experiments were conducted at the complex. The nuclear tests were Hard Hat in 1962, Tiny Tot in 1965, and Pile Driver in 1966. The Hard Hat and Pile Driver nuclear tests involved different types of experiment sections in test drifts at various distances from the explosion in order to determine which sections could best survive in order to design underground command centers. The Tiny Tot nuclear test involved an underground cavity in which the nuclear test was executed. It also provided data in designing underground structures and facilities to withstand a nuclear attack. The underground nuclear fuel storage experiments were Heater Test 1 from 1977 to 1978 and Spent Fuel Test - Climax from 1978 to 1985. Heater Test 1 was used to design the later Spent Fuel Test - Climax experiment. The latter experiment was a model of a larger underground storage facility and primarily involved recording the conditions of the spent fuel and the surrounding granite medium. Fieldwork was performed intermittently in the summers of 2011 and 2013, totaling 17 days. Access to the underground tunnel complex is sealed and unavailable. Restricted to the surface, four buildings, four structures, and 92 features associated with nuclear testing and fuel storage experiment activities at the U15 Complex have been recorded. Most of these are along the west side of the complex and next to the primary access road and are characteristic of an industrial mining site, albeit one with scientific interests. The geomorphological fieldwork was conducted over three days in the summer of 2011. It was discovered that major modifications to the terrain have resulted from four principal activities. These are road construction and maintenance, mining activities related to development of the tunnel complex, site preparation for activities related to the tests and experiments, and construction of drill pads and retention ponds. Six large trenches for exploring across the Boundary geologic fault are also present. The U15 Complex, designated historic district 143 and site 26NY15177, is eligible to the National Register of Historic Places under Criteria A, C, and D of 36 CFR Part 60.4. As a historic district and archaeological site eligible to the National Register of Historic Places, the Desert Research Institute recommends that the area defined for the U15 Complex, historic district 143 and site 26NY15117, be left in place in its current condition. The U15 Complex should also be included in the NNSS cultural resources monitoring program and monitored for disturbances or alterations.

54 ENVIRONMENTAL SCIENCES↗

A Historical Evaluation of the U15 Complex, Nevada National Security Site, Nye County, Nevada

This report presents a historical evaluation of the U15 Complex on the Nevada National Security Site (NNSS) in southern Nevada. The work was conducted by the Desert Research Institute at the request of the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office and the U.S. Department of Defense, Defense Threat Reduction Agency. Three underground nuclear tests and two underground nuclear fuel storage experiments were conducted at the complex. The nuclear tests were Hard Hat in 1962, Tiny Tot in 1965, and Pile Driver in 1966. The Hard Hat and Pile Driver nuclear tests involved different types of experiment sections in test drifts at various distances from the explosion in order to determine which sections could best survive in order to design underground command centers. The Tiny Tot nuclear test involved an underground cavity in which the nuclear test was executed. It also provided data in designing underground structures and facilities to withstand a nuclear attack. The underground nuclear fuel storage experiments were Heater Test 1 from 1977 to 1978 and Spent Fuel Test - Climax from 1978 to 1985. Heater Test 1 was used to design the later Spent Fuel Test - Climax experiment. The latter experiment was a model of a larger underground storage facility and primarily involved recording the conditions of the spent fuel and the surrounding granite medium. Fieldwork was performed intermittently in the summers of 2011 and 2013, totaling 17 days. Access to the underground tunnel complex is sealed and unavailable. Restricted to the surface, four buildings, four structures, and 92 features associated with nuclear testing and fuel storage experiment activities at the U15 Complex have been recorded. Most of these are along the west side of the complex and next to the primary access road and are characteristic of an industrial mining site, albeit one with scientific interests. The geomorphological fieldwork was conducted over three days in the summer of 2011. It was discovered that major modifications to the terrain have resulted from four principal activities. These are road construction and maintenance, mining activities related to development of the tunnel complex, site preparation for activities related to the tests and experiments, and construction of drill pads and retention ponds. Six large trenches for exploring across the Boundary geologic fault are also present. The U15 Complex, designated historic district 143 and site 26NY15177, is eligible to the National Register of Historic Places under Criteria A, C, and D of 36 CFR Part 60.4. As a historic district and archaeological site eligible to the National Register of Historic Places, the Desert Research Institute recommends that the area defined for the U15 Complex, historic district 143 and site 26NY15117, be left in place in its current condition. The U15 Complex should also be included in the NNSS cultural resources monitoring program and monitored for disturbances or alterations.

54 ENVIRONMENTAL SCIENCES↗