Search NASA⌕ Search

SEARCH · Search NASA

Results for “ROD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Initial development of an RIA envelope for dispersed nuclear fuel

A reactivity insertion accident (RIA) is a design basis accident in which reactivity is rapidly injected as a result of a control rod ejection or blade drop scenario. The resultant power increase can result in fuel rod failure and subsequent release of radioactive material into the reactor’s primary system. For light water reactors, failure under RIAs is typically a result of fuel melt, pellet-cladding interaction, or rod over-pressurization. Fuel melt occurs when the fuel system is unable to transport heat out of the fuel system. Pellet-cladding interaction occurs when an aggressive fuel pellet expansion pushes on an embrittled cladding beyond its strain limit. Rod over-pressurization occurs when a fuel rod exceeds the critical heat flux and departs from nucleate boiling, causing the rod internal pressure to rapidly increase, exceeding the systems pressure, and balloon until it bursts. To prevent failure, regulators have developed safety requirements that limit the injected enthalpy based on the state of the fuel system. However, dispersed fuel could enable the removal or relaxation of regulator-imposed safety criteria. Dispersed fuel embeds fuel particles in a highly conductive metal. Dispersed particles can have a particle radius of 1 µm to greater than 100 µm. Traditional fuel systems are plagued by poor thermal conductivity, especially at higher burnups, thus reducing the ability of the fuel system to respond to an RIA. However, dispersed fuel could improve the ability of the fuel system to transport injected energy away from the fissile material and into the coolant more efficiently. Furthermore, dispersing the fuel particles mitigates hard contact that typically occurs in the traditional zirconium-uranium dioxide fuel system, thus removing pellet-cladding mechanical interaction as a potential failure mechanism. This paper evaluates fuel particles dispersed in a metal matrix using the BISON fuel performance code to develop an initial failure threshold based on melt temperature of the fuel particle and/or cladding material as a function of fission density for beginning-of-life and end-of-life conditions. BISON results show that (1) reducing the size of the particles allows fission density to increase as a function of time, (2) particle-to-particle proximity must be considered to evaluate the limiting conditions, and (3) improving the fuel particle thermal conductivity improves thermal performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial surface conditions affecting the formation of plasma on metal conductors driven by a mega-ampere current pulse

Significant variations in plasma formation have been observed for thick aluminum rods with varying initial surface conditions when pulsed by an intense current in a z-pinch configuration. Rods were fabricated on a lathe to a diameter of 1.0 mm followed by a 300 μm wide and 6 mm long strip milled on the surface to remove a portion of the azimuthally extended machining marks left by the lathe. A subset of these rods were then electropolished, reducing the azimuthally extended machining marks as well as reducing the mean surface roughness. Here, the fabrication process provided two types of rods with several surface finishes: a smooth surface (both milled flat face and curved region), a rough surface (milled flat faced region), and an azimuthally extended rough surface (curved region), to study the effect of surface finish on plasma formation. Rods with azimuthally extended surface defects left by the machining process form plasma early compared to rods that have had the azimuthally extended features removed and/or reduce by electropolishing the surface or milling away a section of the surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanorod length-dependent photodriven H2 production in 1D CdS–Pt heterostructures

Colloidal quantum confined semiconductor-metal heterostructures are promising candidates for solar energy conversion because their light absorbing semiconductor and catalytic components can be independently tuned and optimized. Although the light-to-hydrogen efficiencies of such systems have shown interesting dependences on the morphologies of the semiconductor and metal domains, the mechanisms of such dependences are poorly understood. Here, we use Pt tipped 0D CdS quantum dots (with ∼4.6 nm diameter) and 1D CdS nanorods (of ∼13.8, 27.8, 66.6, and 88.9 nm average rod lengths) as a model system to study the distance-dependence of charge separation and charge recombination times and their impacts on photo-driven H2 production. The H2 generation quantum efficiency increases from 0.2% ± 0.0% in quantum dots to 28.9% ± 0.4% at a rod length of 28 nm and shows negligible changes at longer rod lengths. The half-life time of electron transfer from CdS to Pt increases monotonically with rod length, from 0.7 ± 0.1 in quantum dots to 170.2 ± 29.5 ps in the longest rods, corresponding to a slight decrease in electron transfer quantum efficiency from 92% to 81%. The amplitude-weighted average lifetime of charge recombination of the electron in Pt with the hole in CdS increases from 4.7 ± 0.4 µs in quantum dots to 149 ± 34 µs in 28 nm nanorods, and the lifetime does not increase further in longer rods, resembling the trend in the observed H2 generation quantum efficiency. Our result suggests that the competition of the charge recombination process with the hole removal by the sacrificial electron donor plays a dominant role in the observed nanorod length dependent overall light driven H2 generation quantum efficiency.

Chemistry↗

Simulation of the NuScale SMR and Investigation of the Effect of Load-Following on Component Lifetimes

The NuScale SMR has been modelled using the Virtual Environment for Reactor Applications (VERA) multiphysics environment and the results compared with the publicly reported data in the Design Certification Application (DCA). The results show an excellent agreement for the compared axial and radial power distributions, temperature coefficients of reactivity, boron and control rod worths, and fast neutron flux. This NuScale model is then used to investigate the effect of different operational modes on reactor components to determine how flexible load-following operation may affect control rod and reactor pressure vessel (RPV) lifetimes. The control rod degradation is confirmed to primarily affect the silver-indium-cadmium (AIC) rod tip. The degradation rate is observed to follow a non-linear function of core power level where the increase in degradation decreases with insertion depth. For the variation in core power levels expected with current load-following schemes, the total control rod degradation is found to be mild, at 5-10% of usable life per cycle for a reactor operating at <80% power. Nonetheless, this enables load following strategies to be confirmed and/or modified to ensure that control rods do not need to be replaced during the 60+ year life of the reactor. The RPV degradation was found to be almost directly proportional to the core power level and was not overly sensitive to flux shape perturbations. Future work is planned using these damage functions to optimize operation over multiple NuScale SMR units and develop strategies for prognostics and health management.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Uranium Processing Signatures for Nuclear Forensics (NA22 End of FY23 Report)

A vacuum induction melting (VIM) furnace was used to produce an ~120 kg depleted uranium (DU) rod in November 2021 from well characterized feedstock to investigate the separation of thorium (Th) and protactinium (Pa) from uranium (U) during U metal casting and quantify the behavior of the 230 Th/ 234 U and 231 Pa/ 235 U radiochronometry systems. This work suggested that while 234 Th, measured by gamma spectrometry, appears to segregate to the top and surface of the rod, the concentration of 230 Th determined by isotope dilution mass spectrometry (IDMS) in drill turnings from multiple locations in the rod, including the hot top, is relatively consistent. To evaluate whether Th is potentially enriched at only the very outer surface of the cast DU rod relative to the bulk material in the cast rod, thin surface samples were collected from the cast DU rod. Locations sampled included the inner diameter (ID) and outer diameter (OD) of the bottom of the casting and the ID, OD, and top face of the hot top (very top of the casting). The locations are shown in Figure 1. Four samples were taken from each location at different depths in the cast material. Each cut took approximately 0.03 – 0.05” off of the casting.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effects of Internal and External Heat Sources on Cladding Microstructure and Rupture Performance

In the event of a Loss of Coolant Accident (LOCA), the primary supply of cooling water for a nuclear reactor is lost, leading to a significant pressure differential across the cladding wall. Without adequate cooling, the fuel rods continue to heat as a result of fission reactions. Research at Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS) is currently focused on evaluating fuel cladding performance using an external infrared lamp as a heat source, whereas legacy testing primarily utilized an internal heating approach. While external heating may better simulate the effect of neighboring fuel rods heating a central rod, it may not accurately represent the internal heat absorption from the fuel during accident transients. The heating dynamics depend greatly on the fuel rod's position within the bundle and the reactor. To fully understand the implications of a LOCA event and assess the influence of internal heating on cladding performance, combined internal heating and pressurization capability was developed at ORNL. Tests were conducted to compare cladding segments heated internally (representing heat from the fuel within the rod) and externally (representing heat from adjacent fuel rods). The findings indicate that both internal and external heating result in comparable rupture temperatures during 5°C/s laboratory LOCA tests and also agree with legacy test data. Axial temperature gradients and internal heat source dispersal were found to significantly impact cladding deformation and rupture geometry. Clear modifications were outlined to further improve the capability with heating rates above 5°C/s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Burnup BWR LOCA Burst Analysis Using High-Fidelity Multiphysics Simulations

The US nuclear industry is looking to improve on the operating economics of the current fleet of light-water reactors (LWRs). One way of achieving this is by operating fuel to higher burnup. In pressurized water reactors (PWRs), relaxing the current burnup limit will allow for cycle length extensions and power uprates; in boiling water reactors (BWRs) it may allow for improved fuel utilization and reduced feed assemblies, as well as more efficient power uprates and increased capacity factors that will support the Administration’s Executive Order to facilitate 5 GW of power uprates at existing nuclear facilities. However, one of the key limitations to operating fuel to higher burnup is the risk of fuel fragmentation, relocation, and dispersal (FFRD). Recognizing the high interest in extending burnup limits, the US Nuclear Regulatory Commission (NRC) has issued Draft Regulatory Guide DG-1434, which defines an approach that would be acceptable to the NRC for addressing FFRD risk. The approach defined will require better understanding of the phenomena leading to FFRD as well as best-estimate simulation methods to understand FFRD risk in high-burnup cores. The Nuclear Energy Advanced Modeling and Simulation program is supporting the FFRD industry challenge problem through development of state-of-the-art, high-fidelity modeling and simulation LWR analysis capabilities; namely, the BISON fuel performance code and the VERA core simulator software. These tools, along with the US NRC TRACE system analysis code, have been utilized for analysis of FFRD risk in both PWR and BWR cores in recent years. The work documented in this report addresses the lack of high-fidelity research for BWRs and builds on a previous activity where the framework has been applied to Cycles 16 through 18 of Limerick Unit 1, a BWR/4, with introduction of 8 high-burnup lead use assemblies (HBLUAs) that were representative of the 8 HBLUAs loaded into Limerick Unit 2 in 2021. VERA was used in this previous activity to model rod-by-rod depletion in these cycles, and its solution was used to initialize a TRACE simulation of a large-break loss-of-coolant accident (LBLOCA) at the end of Cycle 18. In the work documented in this report, the TRACE model was improved by refining the core mesh and utilizing a new feature that allows for capturing the full 3D VERA power distribution in the model. This allows for a more detailed solution for setting BISON boundary conditions. Furthermore, the solutions from VERA and TRACE were used to set up and perform BISON simulations of about 1,000 rods sampled from the core, including all burnup levels. Utilizing two cladding burst models, it was shown that no fuel rods were predicted to burst during the postulated LBLOCA transient. Additionally, a sensitivity study was performed by artificially increasing linear heat rate during the postulated LBLOCA to identify parameters that correlate with rod burst susceptibility. Burnup, fission gas release, and hoop strain were all found to be positively correlated with rod burst susceptibility. Small-break loss-of-coolant accident (SBLOCA) analyses were also performed; these analyses predicted cladding temperature increases that were bounded by the LBLOCA cladding temperatures for all small break sizes studied for this plant. However, future refinements to the plant response assumptions during the SBLOCA could impact the predicted cladding response. Finally, a benchmark study was performed between CTF and TRACE for LOCA conditions to better qualify CTF for BWR LOCA modeling.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of Internal and External Heat Sources on Cladding Microstructure and Rupture Performance

In the event of a Loss of Coolant Accident (LOCA), the primary supply of cooling water for a nuclear reactor is lost, leading to a significant pressure differential across the cladding wall. Without adequate cooling, the fuel rods continue to heat as a result of fission reactions. Research at Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS) is currently focused on evaluating fuel cladding performance using an external infrared lamp as a heat source, whereas legacy testing primarily utilized an internal heating approach. While external heating may better simulate the effect of neighboring fuel rods heating a central rod, it may not accurately represent the internal heat absorption from the fuel during accident transients. The heating dynamics depend greatly on the fuel rod's position within the bundle and the reactor. To fully understand the implications of a LOCA event and assess the influence of internal heating on cladding performance, combined internal heating and pressurization capability was developed at ORNL. Tests were conducted to compare cladding segments heated internally (representing heat from the fuel within the rod) and externally (representing heat from adjacent fuel rods). The findings indicate that both internal and external heating result in comparable rupture temperatures during 5°C/s laboratory LOCA tests and also agree with legacy test data. Axial temperature gradients and internal heat source dispersal were found to significantly impact cladding deformation and rupture geometry. Clear modifications were outlined to further improve the capability with heating rates above 5°C/s.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mechanical Loads on Spent Nuclear Fuel in the General 30 cm Package Drop Scenario

The U.S. Department of Energy Office of Nuclear Energy (DOE-NE) Spent Fuel and Waste Science & Technology (SFWST) research program is guided by the high-level goal of closing prioritized knowledge gaps related to spent nuclear fuel (SNF) storage and transportation, which are summarized by Saltzstein et al. (2020). One of the high-priority knowledge gaps is the identification and quantification of mechanical loads that are expected to affect SNF during normal conditions of transportation and storage to inform the range of physical SNF test programs. This report uses modeling and analysis methods to estimate the mechanical loads on spent nuclear fuel (SNF) in the general 30 cm package drop scenario. The drop scenario assumes impact limiters are in place in the transportation configuration and the impact surface is perfectly rigid. The goal of this analysis is to consider the universe of potential mechanical loading conditions that can happen to SNF and present the results in a manner that is useful for materials testing, decision making, and regulatory rule making purposes. This study uses validated finite element models and methods to perform a broad parametric study of key variables that can affect the mechanical loads on SNF during a hypothetical package free drop scenario. Physical drop test data from a cask and fuel assembly drop test campaign is the basis for model validation. Additionally, the results of the parametric study are used to inform a damage model, which uses multiple nonlinear regression to estimate the relationships between input variables and output response. The parametric finite element analyses consider thousands of input variable combinations, while the damage model estimates millions of combinations. The breadth of this study provides confidence that the potential range of mechanical loads that SNF might experience during the general 30 cm package drop scenario are characterized well enough to consider this knowledge gap closed. While this report documents the overall peak values calculated in this study, the 95 th percentile values, the histograms, and the observed trends are equally important. This study covered a large range of SNF temperatures, room temperature to 300°C, and burnups, 10 GWd/MTU to 62 GWd/MTU. Each temperature and burnup combination has a different cladding yield strain, so it is more meaningful to summarize the calculated cladding strain response as its factor of safety, which is defined relative to the yield strain. The factor of safety is calculated as the yield strain divided by the peak cladding strain. A factor of safety greater than unity indicates that the cladding remains below yield, whereas a value less than unity is indicative of plastic deformation. In all cases of this study a safety factor over 1.0 was calculated, although in the most limiting case at 300°C the safety factor was only 1.01, which suggests that yielding could occur when additional loads like rod internal pressure are included. When the temperature is restricted to 200°C the limiting safety factor increases to 1.28, which has significant margin to accommodate internal pressure and potential local cladding defects that could cause a local stress concentration. An important trend in the calculated fuel rod mechanical loads is that the 2 nd highest loaded fuel rod in an assembly tends to be significantly lower than the highest loaded rod. The implication is that even if one rod in an assembly experiences a failure the loads would have to be significantly higher to cause two or more rods to fail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Update on Radiochemical Assessment of High Burnup Commercially Irradiated Fuel

This work documents an effort to collect burnup measurements on a high burnup rod, designated 6XV, and first cycle accident tolerant fuel (ATF) rod, designated 47I, to enable benchmarking of fuel performance codes and neutronics codes. In addition to measurements, Virtual Environment for Reactor Applications (VERA) full-core-depletion analysis was also performed for the rods that were experimentally analyzed to provide an opportunity for code validation. This effort focuses on collecting data from rods irradiated at Byron Generating Station and shipped to the Oak Ridge National Laboratory (ORNL) hot-cells. This data will also anchor non-destructive examination evaluations of burnup of the various fuel rods undergoing postirradiation examination (PIE) at ORNL. Previous PIE of these fuel rods provides some guidance on the burnup trend across the fuel. Axial gamma spectroscopy scans provide a measure of relative changes in burnup across a fuel pin. Mass spectrometry based burnup measurements performed for this work at specific axial locations in the fuel are fully quantitative. By combining the mass spectrometry data with the gamma scans it is possible to more quantitatively evaluate axial variations in burnup across the entire fuel pin [1]. The combined set of burnup evaluations will be made available to other organizations that have an interest in high burnup radiochemistry data for validation of neutronic simulations and source term evaluation such as the Nuclear Regulatory Commission (NRC).

Harp, Jason [Oak Ridge National Laboratory (ORNL),↗

Results of the CHF-SERTTA In-Pile Transient Boiling Experiments at TREAT

To advance the current understanding of heat transfer between nuclear fuel rod cladding and the surrounding coolant under transient scenarios involving critical heat flux (CHF), the CHF-Static Environment Rodlet Transient Test Apparatus (CHFSERTTA), an in-pile experiment, was developed for and irradiated in the Transient Reactor Test (TREAT) facility at Idaho National Laboratory. The CHF-SERTTA experiment consists of a hollow, borated stainless steel rod submerged in a static water pool. The rod, heated via the (n, a) reaction in boron-10, was designed for investigating in-pile transient heat transfer between the rod surface and the coolant, avoiding the complexity of including the heat transfer between the fuel, gas gap, and cladding in typical light-water reactor (LWR) fuel rods. The instrumentation package for CHF-SERTTA focused on capturing those data that best describe the heat transfer behaviour between the rod and coolant. This paper outlines the CHFSERTTA experiment design and presents the initial results of the experiment campaign.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FUEL PERFORMANCE STUDIES AT IDAHO NATIONAL LABORATORY MAKING USE OF THE BYRON FUEL SHIPMENT

In December of 2023 a shipment of commercially irradiated fuel rods from the Byron Generating Station in Illinois was successfully shipped to the Materials and Fuels Complex (MFC) at Idaho National Laboratory (INL). The make-up of the rods includes a mix of cladding types from traditional ZirloTM, advanced zirconium alloys, and chrome coated ZirloTM. Burnups range from regular end of life values to over 70 GWd/MTU rod average. The R&D plan for the rods involves multiple projects from developing licensing data for new claddings to integral transient tests to support burnup extension efforts in the United States. The R&D began in early 2024 with the nondestructive examinations of the rods after which they will be sectioned for microscopy, mechanical testing, and analytical chemistry. Additionally, many rod segments will be refabricated into new test pins and inserted into a static water capsule for integral Reactivity Initiated Accident (RIA) and Loss of Coolant Accident (LOCA) testing at the TREAT reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Defining Probe Closure Offset and Scan Stitching Methodology for Element Contact Profilometry in the Hot Fuel Examination Facility

The Element Contact Profilometer (ECP) is a non-destructive post-irradiation examination (PIE) method established in the Materials and Fuels Complex (MFC) Hot Fuel Examination Facility (HFEF). The ECP suspends a fuel rod with a standard end-fitting in a vertical orientation and draws it between two opposed Sony probes with sapphire rod tips, which measure the diameter directly as a function of vertical stage position through contact profilometry. The ECP is equipped with concave rollers, which pinch the rod to maintain a consist position between these sapphire probe tips. A schematic of the analysis head is shown in Figure 1. The gripper that suspends the rod end-fitting is able to rotate to allow measuring of any azimuthal angle around the rod. This system is used to characterize the diameter of full-length light water reactor (LWR) irradiated fuel rods at multiple azimuthal angles in support of the Advanced Fuels Campaign (AFC).

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Panel Session 145: Challenges and Opportunities in Establishing a System for Transportation of SNF/UNF

Issues associated with establishing a SNF Transportation System in the U.S. are complex. In part, this is because in the US when discussing SNF, there are two distinct categories. The two categories represent significant differences in ownership, transportation-regulator, and even the physical characteristics of the SNF. Specifically, the physical differences in the SNF include size of the rods, associated quantities to be shipped, cladding material, and radionuclide content/enrichment. The first is commercial SNF (i.e., that associated with nuclear power plants), owned by utilities, until a permanent repository is built with DOE obligated by law to then assume the responsibility for shipping and ownership of the SNF. Since no-permanent repository currently exists, most commercial SNF is stored near the reactor in which it was installed, hence requiring no shipments. Although current shipments of commercial SNF are very limited, the few that do occur are generally performed to support a utilities SNF consolidation effort utility and for post irradiation examination/testing. However, with approximately 83,000 metric tons currently being stored at more than 70 sites around the U.S., when a permanent repository becomes available, the required number of shipments will be extensive. The second category is DOE and research reactor fuel. These fuel rods are generally much smaller in length than commercial fuel rods, with the quantity of rods transported in a shipment significantly less than the number of rods in a typical commercial fuel assembly. Currently, most of the SNF shipments within the U.S come from this category. DOE is currently managing about 2500 metric tons of heavy metal of SNF. This panel focused on updates and status of transportation of SNF/UNF. Panelists provided updates and information on continuing impacts, risk assessment, equipment (rail cars, handling, securement), possible rail routing, and proposed inspection equipment/routing prior to shipments. Panelists with presentations: Preparing for Nuclear Waste Transportation (Daniel Ogg); Challenges and Opportunities in Establishing a System for Transportation of SNF/UNF (Kathy Langan); UNF Transportation: Challenges and Opportunities (Michael Valenzano)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TRIPOLI-4 neutronics calculations for IAEA-CRP benchmark of CEFR start-up tests using new libraries JEFF-3.3 and ENDF/B-VIII

Sodium-cooled Fast Reactors (SFR) are one of the promising Generation IV fast reactors. The China Experimental Fast Reactor (CEFR) is a 65 MWth pool-type SFR with a high neutron leakage core using high enriched uranium oxide fuel. The CEFR start-up tests in 2010 consist of series of neutronics experiments. Essential experimental data are available from the 2018 IAEA-CEFR-CRP benchmark document and useful for the validation of neutron transport codes and nuclear data libraries. The TRIPOLI-4 Monte Carlo transport code is a general-purpose neutronics code using continuous-energy nuclear data libraries. It has a rich validation database covering different computational and experimental benchmark data sets to assure the accuracy and credibility of numerical studies. Previous TRIPOLI-4 SFR core physics calculations used mainly MOX fuels. SFR control rod worth studies with TRIPOLI-4 were mainly on big-size cores. To test the modeling capability of TRIPOLI-4 on fuel loading patterns and on variable control rods positions for SFRs and to check recent nuclear data libraries, it is interesting to investigate the CEFR start-up tests in this work, including core states from subcritical to supercritical, control rods and rod group worth, point kinetics parameters, and radial foil activation measurements. TRIPOLI-4 calculation results using new data libraries JEFF-3.3, ENDF/B-VIII, and those of ENDF/B-VII.1 for different CEFR core states are reported here. By means of different options of TRIPOLI-4, control-rod SAs reactivity worth, point kinetics parameters, and radial {sup 237}Np(n,f) fission rate distribution were successfully evaluated. Both ENDF/B-VIII and JEFF-3.3 nuclear data libraries provided reliable results with a difference of 170 +/- 11 pcm in k{sub eff}.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Whole core analysis of OECD/NEA TVA-WB1 benchmark exercise 1 using continuous-energy Monte Carlo code MVP with JENDL-4.0u and ENDF/B-VII.0

The TVA WB1 benchmark problem was precisely modeled in accordance with the geometry and material specifications, and benchmark exercise 1 was solved with the MVP code and the nuclear data libraries based on JENDL-4.0u (JENDL-4.0 updated file) and ENDF/B-VII.0. The criticality, the control rod bank worth, the isothermal temperature coefficient (ITC), the integral rod worth of bank D, and differential soluble boron worth (DBW) were obtained. The criticality and the control rod bank worth were compared with the measured data and published calculation results with other codes, Serpent and KENO. The criticality and the control rod bank worth calculated by MVP and the libraries agree with the measured and the published calculation results within the criteria specified in the ANSI/ANS standard. From these results, the calculation model for the MVP and the libraries was verified. The other parameters such as ITC, the integral rod worth, and DBW were also compared between JENDL-4.0u and ENDF/B-VII.0. The comparison of the results shows JENDL-4.0u and ENDF/B-VII.0 give comparable results within the standard deviation, the difference between libraries is small. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Asymmetrical cavity design that bypasses mode mixings in axion haloscope experiments

Microwave cavities used in axion haloscope experiments typically employ a tuning rod as a means to widen the range of resonance frequencies at which it is sensitive to axion-to-photon conversion. A realistic tuning mechanism requires a gap between the cavity end caps and the tuning rod to ensure movement, and causes some modes to hybridize with the resonant mode that is being tracked for the experiment. These so-called mode mixings lead to gaps in the frequency range that practically lose sensitivity to axions. Here, to solve this problem, we present a cavity design which, for two tuning rod configurations corresponding to a lower and higher frequency range, have a dielectric rod inserted at a specific location that makes the cavity asymmetrical. Moving the tuning rod closer to the dielectric insert changes the location and frequency of the mode mixing compared to when it is farther away from it. This design is easily realizable in practical experiments and makes possible an axion dark matter search with minimal loss in sensitivity due to mode mixings. We also show that the same design has the same desired effect when cavity dimensions are scaled down to be smaller and are at higher resonance frequencies.

Axion↗