Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Quantum Imaging with X-rays

Quantum imaging encompasses a broad range of methods that exploit the quantum properties of light to capture information about an object. One such approach involves using a two-photon quantum state, where only one photon interacts with the object being imaged while its entangled partner carries spatial or temporal information. To implement this technique, it is necessary to generate specific quantum states of light and detect photons at the single-photon level. While this method has been successfully demonstrated in the visible electromagnetic spectrum, extending it to X-rays has faced significant challenges due to the difficulties in producing a sufficient rate of X-ray photon pairs and detecting them with adequate resolution. Here, we demonstrate record high rates of correlated X-ray photon pairs produced via a spontaneous parametric down-conversion process and we employ these photons to perform quantum correlation imaging of several objects, including a biological sample (E. cardamomum seedpod). Notably, we report an unprecedented detection rate of about 6,300 pairs per hour and the observation of energy anti-correlation for the X-ray photon pairs. We also present a detailed analysis of the properties of the down-converted X-ray photons, as well as a comprehensive study of the correlation imaging formation, including a study of distortions and corrections. These results mark a substantial advancement in X-ray quantum imaging, expanding the possibilities of X-ray quantum optical technologies, and illustrating the pathway towards enhancing biological imaging with reduced radiation doses.

Gofron, Kaz [ORNL] (ORCID:0000000314415736)↗

Infrared images of Jupiter at 5-micrometer wavelength during the Voyager 1 encounter

A coordinated program to observe Jupiter at high spatial resolution in the 5-micrometer wavelength region was undertaken to support Voyager 1 imaging and infrared radiation experiment targeting. Jupiter was observed over a 5-month period from Palomar and Mauna Kea observatories. The frequency of observations allowed the selection of interesting areas for closer Voyager examination and also provided good short-term monitoring of variations in cloud morphology. Significant global changes in the 5-micrometer distribution are seen over this time period.

Terrile, R. J.↗

Thermal infrared satellite data for the study of tectonic features

Multispectral thermal infrared data from the NOAA-7 Advanced Very High Resolution Radiometer (AVHRR) have been processed to evaluate their potential for mapping tectonic features. Day/night ratio data from 3 thermal bands between 3.7 and 12.0 microns were used to construct a thermal infrared color image that emphasizes heat retention differences in surface materials as a function of wavelength. The study area is an arid region of the Arabian Peninsula where lithologic units are widely exposed to satellite detectors. In spite of the coarse resolution of 1.1 km at nadir, the image of emitted radiation data contains prominent features that appear to relate to fault systems, unmapped extensions of fault systems, and drainage patterns that are lacking in AVHRR reflected radiation data.

Andre, C. G.↗

Strategy and calculations for the design of baffles for Wolter Type II telescopes

Spaceflight, stellar pointing telescopes require baffle systems to define the field of view and protect this observational area from stray and scattered light. In the case of near normal incidence telescope systems, the problem consists in controlling the stray/scattered radiation reaching the image plane when circular plates, the primary and secondary mirrors, are the imaging elements. The case addressed in this paper is quite different in that it involves baffling two conical surfaces, i.e., the primary and secondary mirrors of a Wolter Type II telescope. A strategy is described for systematically moving through the telescope system and establishing criteria for placement of baffles. Calculations are given which determine the size and number of permitted baffles as a function of practical physical parameters. Clear options are given for the design of minimum baffle lengths to meet packaging constraints.

Mangus, John D.↗

The Pinhole/Occulter Facility

To image X-radiation efficiently at energies above about 10 keV requires the use of 'shadow optics' techniques. The Pinhole/Occulter Facility (P/OF) represents an application of these techniques for observations in high-energy astrophysics, especially the study of solar coronal activity in hard X-rays and gamma rays. P/OF will achieve angular resolutions on the order of 0.2 arcsec for an instrument deployment length of 50 m. Because of this large structural scale, P/OF has been proposed as an attached payload for the Space Station. Meanwhile, several smaller-scale instruments are being developed.

Hudson, Hugh S.↗

Observations of cosmic-ray electrons and positrons using an imaging calorimeter

A ballon-borne magnet spectrometer system was flown for 5.5 hr at an altitude of more than 117,00 feet from Prince Albert, Saskatchewan (Canada), on 1989 September 5, when the Newark neutron monitor rate was 2952. The instrument was a modified version of the one used to observe antiprotons in 1979. The most significant modification was the addition of an imaging calorimeter, 7.33 radiation lengths thick. Inclusion of the calorimeter has significantly improved the ability to distinguish electrons and positrons from the other constituents of the cosmic rays. The absolute electron flux has been determined in the energy interval 1.3-26 GeV. The electron spectrum at the top of the atmosphere was found to be J(sub e-) = 177E(exp -(3.15+/-0.13)) electrons/ sq m/(sr s GeV) in the energy range 4.0-26 GeV. Below 4 GeV, the spectrum showed flattening, which is consistent with the effect of solar modulation. The e(+)/(e(+)+e(-)) ratio was found to be (0.11 +/- 0.03) in the energy range 5.2-13 GeV.

Golden, R. L.↗

NASA IKONOS Multispectral Radiometric Calibration and 3-Year Temporal Stability Assessment

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can place confidence in the imagery they use and can fully understand its properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other system. In addition, the user community has little or no insight into the design and operation of commercial sensors or into the methods involved in generating commercial products. To address this calibration need, the NASA Stennis Space Center (SSC) Earth Science Applications (ESA) Directorate established a commercial satellite imaging radiometric calibration team consisting of three independent groups: NASA, SSC,ESA, the University of Arizona Remote Sensing Group, and South Dacota State University. Each group determined the absolute radiometric calibration coefficients of the Space Imaging IKONOS 4-band, 4 m multispectral product covering the visible through near-infrared spectral region. For a three year period beginning in 2000, each team employed some variant of a reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with IKONOS image acquisitions and radiative transfer calculations. Several study sites throughout the United States were employed that covered nearly the entire dynamic range of the IKONOS sensor. IKONOS at-sensor radiance values were compared to those estimated by each independent group to determine the IKONOS sensor's radiometric accuracy and stability. Over 10 individual vicariously determined at-sensor radiance estimates were used each year. When combined, these estimates provided a high-precision radiometric gain calibration coefficient. No significant calibration offset was observed. The results of this evaluation provide the scientific community with an independent assessment of the IKONOS sensor's absolute calibration and temporal stability over the 3-year period. While the techniques and method described in this paper reflect those developed at the NASA SSC, the results of the entire team are included.

Pagnutti, Mary↗

JACIE Radiometric Assessment of QuickBird Multispectral Imagery

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can place confidence in the imagery they use and can fully understand its properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, the NASA Stennis Space Center (SSC) Earth Science Applications (ESA) directorate,through the Joint Agency for Commercial Imagery Evaluation (JACIE) framework, established a commercial imaging satellite radiometric calibration team consisting of two groups: 1) NASA SSC ESA, supported by South Dakota State University, and 2) the University of Arizona Remote Sensing Group. The two groups determined the absolute radiometric calibration coefficients of the Digital Globe 4-band, 2.4-m QuickBird multispectral product covering the visible through near-infrared spectral region. For a 2-year period beginning in 2002, both groups employed some variant of a reflectance-based vicarious calibration approach, which required ground-based measurements coincident with QuickBird image acquisitions and radiative transfer calculations. The groups chose several study sites throughout the United States that covered nearly the entire dynamic range of the QuickBird sensor. QuickBird at-sensor radiance values were compared with those estimated by the two independent groups to determine the QuickBird sensor's radiometric accuracy. Approximately 20 at-sensor radiance estimates were vicariously determined each year. The estimates were combined to provide a high-precision radiometric gain calibration coefficient. The results of this evaluation provide the user community with an independent assessment of the QuickBird sensor's absolute calibration and stability over the 2-year period. While the techniques and method described reflect those developed at the NASA SSC, the results of both JACIE team groups are included in this paper.

Pagnutti, Mary↗

Radiometric Characterization Results for the IKONOS, Quickbird, and OrbView-3 Sensor

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities better understand commercial imaging satellite properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, the NASA Applied Sciences Directorate (ASD) at Stennis Space Center established a commercial satellite imaging radiometric calibration team consisting of three independent groups: NASA ASD, the University of Arizona Remote Sensing Group, and South Dakota State University. Each group independently determined the absolute radiometric calibration coefficients of available high-spatial-resolution commercial 4-band multispectral products, in the visible though near-infrared spectrum, from GeoEye(tradeMark) (formerly SpaceImaging(Registered TradeMark)) IKONOS, DigitalGlobe(Regitered TradeMark) QuickBird, and GeoEye (formerly ORBIMAGE(Registered TradeMark) OrbView. Each team member employed some variant of reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with image acquisitions and radiative transfer calculations. Several study sites throughout the United States that covered a significant portion of the sensor's dynamic range were employed. Satellite at-sensor radiance values were compared to those estimated by each independent team member to evaluate the sensor's radiometric accuracy. The combined results of this evaluation provide the user community with an independent assessment of these sensors' absolute calibration values.

Holekamp, Kara↗

The Atmospheric Response to High Nonthermal Electron-beam Fluxes in Solar Flares. II. Hydrogen-broadening Predictions for Solar Flare Observations with the Daniel K. Inouye Solar Telescope

Redshifted components of chromospheric emission lines in the hard X-ray impulsive phase of solar flares have recently been studied through their 30 s evolution with the high resolution of the Interface Region Imaging Spectrograph. Radiative-hydrodynamic flare models show that these redshifts are generally reproduced by electron-beam-generated chromospheric condensations. The models produce large ambient electron densities, and the pressure broadening of the hydrogen Balmer series should be readily detected in observations. To accurately interpret the upcoming spectral data of flares with the DKIST, we incorporate nonideal, nonadiabatic line-broadening profiles of hydrogen into the RADYN code. These improvements allow time-dependent predictions for the extreme Balmer line wing enhancements in solar flares. We study two chromospheric condensation models, which cover a range of electron-beam fluxes (1 − 5 × 10^(11) erg s^(−1) cm^(−2)) and ambient electron densities (1 − 60 × 10^(13) cm^(−3)) in the flare chromosphere. Both models produce broadening and redshift variations within 10 s of the onset of beam heating. In the chromospheric condensations, there is enhanced spectral broadening due to large optical depths at Hα, Hβ, and Hγ, while the much lower optical depth of the Balmer series H12−H16 provides a translucent window into the smaller electron densities in the beam-heated layers below the condensation. The wavelength ranges of typical DKIST/ViSP spectra of solar flares will be sufficient to test the predictions of extreme hydrogen wing broadening and accurately constrain large densities in chromospheric condensations.

Adam F. Kowalski↗

What is happening at NNSS today

Presentation to be presented during the first annual Prompt Radiation Detection and Imaging Workshop, hosted by the NNSS Dynamic Instruments Team, April 25–28, 2022, at NLV C-01 Auditorium and via closed Webex.

99 GENERAL AND MISCELLANEOUS↗

Charge multiplication in thin scCVD diamond detectors

This presentation describes experimental measurements with thin scCVD diamond detectors and their DD and DT neutron sources. This presentation will be given at the NNSS Prompt Radiation Detection and Imaging Workshop April 25-28, 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D Aerosol-Cloud Radiative Interaction Observed in Collocated MODIS and ASTER Images of Cumulus Cloud Fields

3D aerosol-cloud interaction is examined by analyzing two images containing cumulus clouds in biomass burning regions in Brazil. The research consists of two parts. The first part focuses on identifying 3D clo ud impacts on the reflectance of pixel selected for the MODIS aerosol retrieval based purely on observations. The second part of the resea rch combines the observations with radiative transfer computations to identify key parameters in 3D aerosol-cloud interaction. We found that 3D cloud-induced enhancement depends on optical properties of nearb y clouds as well as wavelength. The enhancement is too large to be ig nored. Associated biased error in 1D aerosol optical thickness retrie val ranges from 50% to 140% depending on wavelength and optical prope rties of nearby clouds as well as aerosol optical thickness. We caution the community to be prudent when applying 1D approximations in comp uting solar radiation in dear regions adjacent to clouds or when usin g traditional retrieved aerosol optical thickness in aerosol indirect effect research.

Wen, Guoyong↗

In Vivo Imaging of the Microglial Landscape After Whole Brain Radiation Therapy

Whole brain radiation therapy (WBRT) is an important treatment for patients with multiple brain metastases, but can also cause cognitive deterioration. Microglia, the resident immune cells of the brain, promote a proinflammatory environment and likely contribute to cognitive decline after WBRT. To investigate the temporal dynamics of the microglial reaction in individual mice to WBRT, we developed a novel in vivo experimental model using cranial window implants and longitudinal imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved radiographic image amplifier panel

Layered image amplifier for radiographic /X ray and gamma ray/ applications, combines very high radiation sensitivity with fast image buildup and erasure capabilities by adding a layer of material that is both photoconductive and light-emitting to basic image amplifier and cascading this assembly with a modified Thorne panel.

Brown, R. L., Sr.↗

Comparison of thermal (FLIR) and television images

The human eye is sensitive to electromagnetic radiation in the 0.4 to 0.7 micron band (light). Thermal imaging (TI) systems are sensitive to heat radiation in the infrared band (3-5 or 8-14 microns) and are capable of transforming the distribution of relative temperatures in a scene into a visible TV image. The present experiment was designed to investigate the impact of the difference between TIs and regular TV images on the detection and identification of natural and man-made targets. Parallel TV and TI videotapes were recorded during helicopter flights. Fifteen subjects who viewed both the TV and the TI images (separately), were asked to detect predefined targets and to identify features pointed out to them by the experimenter. In general, performance with TVs was superior to performance with TIs in terms of response times and errors. However, subjects required significantly less time to detect man-made objects with TIs than with TVs. The correlation between the performance of the same task with the two kinds of images was very low. The results are discussed in terms of image quality and in terms of humans' internal representations of natural categories.

Brickner, Michael S.↗