Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Source Replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The use of intensity-modulated radiation therapy photon beams for improving the dose uniformity of electron beams shaped with MLC

Electrons are ideal for treating shallow tumors and sparing adjacent normal tissue. Conventionally, electron beams are collimated by cut-outs that are time-consuming to make and difficult to adapt to tumor shape throughout the course of treatment. We propose that electron cut-outs can be replaced using photon multileaf collimator (MLC). Two major problems of this approach are that the scattering of electrons causes penumbra widening because of a large air gap, and available commercial treatment planning systems (TPSs) do not support MLC-collimated electron beams. In this study, these difficulties were overcome by (1) modeling electron beams collimated by photon MLC for a commercial TPS, and (2) developing a technique to reduce electron beam penumbra by adding low-energy intensity-modulated radiation therapy (IMRT) photons (4 MV). We used blocks to simulate MLC shielding in the TPS. Inverse planning was used to optimize boost photon beams. This technique was applied to a parotid and a central nervous system (CNS) clinical case. Combined photon and electron plans were compared with conventional plans and verified using ion chamber, film, and a 2D diode array. Our studies showed that the beam penumbra for mixed beams with 90 cm source to surface distance (SSD) is comparable with electron applicators and cut-outs at 100 cm SSD. Our mixed-beam technique yielded more uniform dose to the planning target volume and lower doses to various organs at risk for both parotid and CNS clinical cases. The plans were verified with measurements, with more than 95% points passing the gamma criteria of 5% in dose difference and 5 mm for distance to agreement. In conclusion, the study has demonstrated the feasibility and potential advantage of using photon MLC to collimate electron beams with boost photon IMRT fields.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multiplicity fluctuations due to the temperature fluctuations in high-energy nuclear collisions

We investigate the multiplicity fluctuations observed in high-energy nuclear collisions attributing them to intrinsic fluctuations of temperature of the hadronizing system formed in such processes. To account for these fluctuations, we replace the usual Boltzmann-Gibbs (BG) statistics by the nonextensive Tsallis statistics characterized by the nonextensivity parameter q, with |q-1| being a direct measure of fluctuation. In the limit of vanishing fluctuations, q{yields}1 and Tsallis statistics converge to the usual BG. We evaluate the nonextensivity parameter q and its dependence on the hadronizing system size from the experimentally observed collision centrality dependence of the mean multiplicity <N> and its variance Var(N). We attribute the observed system size dependence of q to the finiteness of the hadronizing source, with q=1 corresponding to an infinite, thermalized source with a fixed temperature, and with q>1 (which is observed) corresponding to a finite source in which both the temperature and energy fluctuate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

Here, we present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3 He-free radiation portal monitor testing campaign at the European Commission’s Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252 Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group’s system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241 Am. Lastly, both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

3He replacement technology↗

Experimental study on cesium immobilization in struvite structures

Ceramicrete, a chemically bonded phosphate ceramic, was developed for nuclear waste immobilizationand nuclear radiation shielding. Ceramicrete products are fabricated by an acid–base reaction betweenmagnesium oxide and mono potassium phosphate that has a struvite-K mineral structure. In this study,we demonstrate that this crystalline structure is ideal for incorporating radioactive Cs into a Ceramicretematrix. This is accomplished by partially replacing K by Cs in the struvite-K structure, thus formingstruvite-(K, Cs) mineral. X-ray diffraction and thermo-gravimetric analyses are used to confirm such areplacement. The resulting product is non-leachable and stable at high temperatures, and hence it isan ideal matrix for immobilizing Cs found in high-activity nuclear waste streams. The product can also be used for immobilizing secondary waste streams generated during glass vitrification of spent fuel, or the method described in this article can be used as a pretreatment method during glass vitrification of high level radioactive waste streams. Furthermore, it suggests a method of producing safe commercial radioactive Cs sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reproducible, rugged, and inexpensive photocathode x-ray diode

The photoemissive cathode type of x-ray diode (XRD) is popular for measuring time and spectrally resolved output of pulsed power experiments. Vitreous carbon XRDs currently used on the Sandia National Laboratories Z-machine were designed in the early 1980s and use materials and processes no longer available. Additionally cathodes used in the high x-ray flux and dirty vacuum environment of a machine such as Z suffer from response changes requiring recalibration. In searching for a suitable replacement cathode, we discovered very high purity vitreous-carbon planchets are commercially available for use as biological substrates in scanning electron microscope (SEM) work. After simplifying the photocathode mounting to use commercially available components, we constructed a set of 20 XRDs using SEM planchets that were then calibrated at the National Synchrotron Light Source at Brookhaven National Laboratory. We present comparisons of the reproducibility and absolute calibrations between the current vitreous-carbon XRDs and our new design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced interferometric profile measurements through refractive media

Optical profilers are valuable tools for the characterization of microelectromechanical systems (MEMSs). They use phase sifting interferometry (PSI) or vertical scanning interferometry to measure the topography of microscale structures with nanometer resolution. However, for many emerging MEMS applications, the sample needs to be imaged while placed in a liquid or in a package with a glass window. The increased refractive index of the transparent medium degrades the interference image contrast and prevents any measurement of the sample. We report on the modification of a Veeco NT1100 optical profiler to enable PSI measurements through refractive media. This approach can be applied to any other optical profiler with PSI capability. The modification consists in replacing the original illumination source with a custom-built narrow linewidth source, which increases the coherence length of the light and the contrast of the interference image. We present measurements taken with the modified configuration on samples covered with 3 mm water or 500 {mu}m glass, and we compare them to measurements of uncovered samples. We show that the measurement precision is only slightly reduced by the water and glass, and that it is still sufficiently high for typical MEMS applications. The described method can be readily used for measuring through other types and thicknesses of refractive materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a 3D Diode Array Dosimeter for Helical Tomotherapy Delivery QA

The Delta4 biplanar diode array dosimeter was validated for helical tomotherapy delivery QA. The basic detector characteristics were found to be satisfactory in terms of short-term reproducibility (0.1%), linearity (<0.1%), dose rate dependence (0.4%), and absolute calibration accuracy (0.4% in the center of the phantom compared with the independently calibrated diode). Relative calibration of the arrays was verified by comparison with film and by rotating the detector 180{sup o}. The dosimeter response to rotational irradiation changed by no more than 0.2% when one of the detector boards was replaced by the homogeneous phantom material. The daily output correction factor can be derived from a Delta4 measurement in a uniform cylindrical field. The {gamma}(3%, 3 mm) passing rate (absolute dose) was above 90% for all 9 evaluated clinical plans, and above 96% for all but one. The mean passing rate was 97 {+-} 2.7%. The plans varied in modulation factor, pitch, and calculation grid size. For best results, the phantom needs to be aligned carefully, preferably by megavoltage computed tomography imaging.

07 ISOTOPE AND RADIATION SOURCES↗

Steady-State Vacuum Ultraviolet Exposure Facility With Automated Lamp Calibration and Sample Positioning Fabricated

The Next Generation Space Telescope (NGST) will be placed in an orbit that will subject it to constant solar radiation during its planned 10-year mission. A sunshield will be necessary to passively cool the telescope, protecting it from the Sun s energy and assuring proper operating temperatures for the telescope s instruments. This sunshield will be composed of metalized polymer multilayer insulation with an outer polymer membrane (12 to 25 mm in thickness) that will be metalized on the back to assure maximum reflectance of sunlight. The sunshield must maintain mechanical integrity and optical properties for the full 10 years. This durability requirement is most challenging for the outermost, constantly solar-facing polymer membrane of the sunshield. One of the potential threats to the membrane material s durability is from vacuum ultraviolet (VUV) radiation in wavelengths below 200 nm. Such radiation can be absorbed in the bulk of these thin polymer membrane materials and degrade the polymer s optical and mechanical properties. So that a suitable membrane material can be selected that demonstrates durability to solar VUV radiation, ground-based testing of candidate materials must be conducted to simulate the total 10- year VUV exposure expected during the Next Generation Space Telescope mission. The Steady State Vacuum Ultraviolet exposure facility was designed and fabricated at the NASA Glenn Research Center at Lewis Field to provide unattended 24-hr exposure of candidate materials to VUV radiation of 3 to 5 times the Sun s intensity in the wavelength range of 115 to 200 nm. The facility s chamber, which maintains a pressure of approximately 5 10(exp -6) torr, is divided into three individual exposure cells, each with a separate VUV source and sample-positioning mechanism. The three test cells are separated by a water-cooled copper shield plate assembly to minimize thermal effects from adjacent test cells. Part of the interior sample positioning mechanism of one test cell is shown in the illustration. Of primary concern in VUV exposure is the maintenance of constant measured radiation intensity so that the sample s total exposure can be determined in equivalent Sun hours. This is complicated by the fact that a VUV lamp s intensity degrades over time, necessitating a decrease in the distance between the test samples and the lamp. The facility overcomes this challenge by periodically measuring the lamp s intensity with a cesium-iodide phototube and adjusting the sample distance as required to maintain constant exposure intensity. Sample positioning and periodic phototube location under the lamp are both achieved by a single lead-screw assembly. The lamps can be isolated from the main vacuum chamber for cleaning or replacement so that samples are not exposed to the atmosphere during a test.

Sechkar, Edward A.↗

Note: Easy-to-maintain electron cyclotron resonance (ECR) plasma sputtering apparatus featuring hybrid waveguide and coaxial cables for microwave delivery

The branched-waveguide electron cyclotron resonance plasma sputtering apparatus places quartz windows for transmitting microwaves into the plasma source not in the line of sight of the target. However, the quartz windows must be replaced after some time of operation. For maintenance, the loop waveguide branching from the T-junction must be dismounted and re-assembled accurately, which is a time-consuming job. We investigated substituting the waveguide branches with two sets of coaxial cables and waveguide/coaxial cable converters to simplify assembly as far as connection and disconnection go. The resulting hybrid system worked well for the purposes of plasma generation and film deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reaction-Induced Fracturing of Porous Carbonate Rocks during Volume-Increasing Replacement by Witherite

Volume-increasing replacement reactions can lead either to fracturing of the parent phase or to the formation of cohesive layers that passivate further reaction, but the factors that drive one outcome or the other are not understood. In this experimental study, we investigated the volume-increasing replacement of carbonate rocks (consisting of CaCO 3 and CaMg(CO 3 ) 2 ) of different porosity by witherite (BaCO 3 ). Samples were characterized using scanning electron microscopy, Raman spectroscopy, small-angle neutron/X-ray scattering, X-ray tomography, and scanning transmission electron microscopy. We observed the formation of a witherite reaction layer and witherite formation within pores and along grain boundaries. Despite this being a volume-increasing replacement reaction, newly formed witherite was porous, potentially allowing further replacement. Filled fractures were observed in the low-porosity carbonates, whereas witherite formed within pores in high-porosity carbonates. We conclude that fracturing of the parent phase versus passivation is contingent on the initial microstructure of the parent with an optimal degree of porosity required for fracturing.

Calcite↗

METHODS FOR ESTIMATING FLUXES AND ABSORPTIONS OF FAINT X-RAY SOURCES

X-ray sources with very few counts can be identified with low-noise X-ray detectors such as the Advanced CCD Imaging Spectrometer on board the Chandra X-ray Observatory. These sources are often too faint for parametric spectral modeling using well-established methods such as fitting with XSPEC. We discuss the estimation of apparent and intrinsic broadband X-ray fluxes and soft X-ray absorption from gas along the line of sight to these sources, using nonparametric methods. Apparent flux is estimated from the ratio of the source count rate to the instrumental effective area averaged over the chosen band. Absorption, intrinsic flux, and errors on these quantities are estimated from comparison of source photometric quantities with those of high signal-to-noise spectra that were simulated using spectral models characteristic of the class of astrophysical sources under study. The concept of this method is similar to the long-standing use of color-magnitude diagrams in optical and infrared astronomy, with X-ray median energy replacing color index and X-ray source counts replacing magnitude. Our nonparametric method is tested against the apparent spectra of approx2000 faint sources in the Chandra observation of the rich young stellar cluster in the M 17 H II region. We show that the intrinsic X-ray properties can be determined with little bias and reasonable accuracy using these observable photometric quantities without employing often uncertain and time-consuming methods of nonlinear parametric spectral modeling. Our method is calibrated for thermal spectra characteristic of stars in young stellar clusters, but recalibration should be possible for some other classes of faint X-ray sources such as extragalactic active galactic nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-333: Towards Customizable Radiotherapy Enhancement (CuRE) for Prostate Cancer Using Cisplatin Nanoparticles

Purpose: Replacing routinely used brachytherapy spacers with multifunctional ones loaded with cisplatin nanoparticles (CNP), which can be released into the tumor after implantation, could enable customizable radiation boosting to the prostate tumor in addition to chemotherapy effect. This study investigates the feasibility of customizing the intra-tumor biodistribution and corresponding dose enhancement (DEF) over time for the released CNP as a function of nanoparticle size. Methods: Dose enhancement factors (DEF) due to photon-induced emission of photo-/Auger electrons from CNPs were calculated as a function of concentration using previously published analytical calculation method. An experimentally determined diffusion coefficient (D) for 10 nm nanoparticles in mouse tumor model was employed to estimate D for other sizes using the Stoke- Einstein equation. The error function diffusion model in the experimental study was applied to generate the intra-tumor concentration profile for a burst release of CNPs from the spacer over time. The corresponding DEF profiles were then determined for brachytherapy using Pd-103 and I-125 sources. Results: As expected, the generated profiles showed greater DEF over time for smaller CNP sizes at sample distances from the spacer. For example, for a centrally located spacer, clinically significant DEF (> 20%) could be achieved near the tumor periphery (ca. 0.85 cm distance from the spacer for average PCa tumor size) after 20, and 100 days, respectively for CNPs sizes of 2 nm, and 10 nm, using I-125. Meanwhile for Pd-103, clinically significant DEF could be achieved at the same position after 22 and 108 days, respectively, for same size particles. Conclusion: Our preliminary results demonstrate the feasibility of customizing dose enhancement to prostate tumors as a function of spacer location, brachytherapy source type or size of CNPs released from multifunctional spacers. Such an approach could enable customizable radiation boosting to tumor sub-volumes, while minimizing dose to healthy tissues.

60 APPLIED LIFE SCIENCES↗

Pulsed pyroelectric crystal-powered gamma source

A compact pulsed gamma generator is being developed to replace radiological sources used in commercial, industrial and medical applications. Mono-energetic gammas are produced in the 0.4 - 1.0 MeV energy range using nuclear reactions such as {sup 9}Be(d,n{gamma}){sup 10}B. The gamma generator employs an RF-driven inductively coupled plasma ion source to produce deuterium ion current densities up to 2 mA/mm{sup 2} and ampere-level current pulses can be attained by utilizing an array extraction grid. The extracted deuterium ions are accelerated to approximately 300 keV via a compact stacked pyroelectric crystal system and then bombard the beryllium target to generate gammas. The resulting microsecond pulse of gammas is equivalent to a radiological source with curie-level activity.

43 PARTICLE ACCELERATORS↗

Isotope Production at the Jefferson Lab LERF Facility

The project initially proceeded well, meeting all of the Milestones. However, the need to create a new irradiation area in the LERF (the initial proposal was to use the CEBAF Injector) used up a larger fraction of the budget than foreseen. A further problem arose when the hot-cell became unavailable at VCU, followed by VCU dropping out of the collaboration. This meant that we were unable to separate the 67 Cu from the gallium. We replaced this by carrying out detailed gamma spectroscopy to determine the quantity of 67 Cu produced. This work was published as presentations in November of 2021 by the two doctoral students (Geno Santistevan and Robert Bentley) and proceedings articles for American Nuclear Society’s topical meeting AccApp21 (https://www.ans.org/pubs/proceedings/issue-3206/), as well as in invited, expanded versions in the peer-reviewed journal “Nuclear Science and Engineering”. Geno and Robert have subsequently successfully leveraged this research to achieve “doctoral candidacy” status and are expected to defend their dissertations in the Fall of 2023.

07 ISOTOPE AND RADIATION SOURCES↗

Improved DC Gun and Insulator Assembly

Many user facilities such as synchrotron radiation light sources and free electron lasers rely on DC high voltage photoguns with internal field gradients as high as 10 to 15 MV/m. These high gradients often lead to field emission which poses serious problems for the photocathode used to generate the electron beam and the ceramic insulators used to bias the photocathode at high voltage. Ceramic insulators are difficult to manufacture, require long commissioning times, and have poor reliability, in part because energetic electrons bury themselves in the ceramic causing a buildup of charge and eventual puncture, and also because large diameter ceramics are difficult to braze reliably. The lifetimes of photo cathodes inside high current DC guns exhibiting field emission are limited to less than a hundred hours. Reducing the surface gradients on the metals reduces the field emission, which serves to maintain the required ultrahigh vacuum condition. A novel gun design with gradients around 5 MV/m and operating at 350 kV, a major improvement over existing designs, was proposed that allows for the in-situ replacement of photo cathodes in axially symmetric designs using inverted ceramics. In this project, the existing JLAB CEBAF asymmetric gun design with an inverted ceramic support was modeled and the beam dynamics characterized. An improved structure was designed that reduces the surface gradients and improves the beam optics. To minimize the surface gradients, a number of electrostatic gun designs were studied to determine the optimum configuration of the critical electrodes within the gun structure. Coating experiments were carried out to create a charge dissipative coating for cylindrical ceramics. The phase II proposal, which was not granted, included the design and fabrication of an axially symmetric DC Gun with an inverted ceramic that would operate with less than 5 MV/m at 350 kV and would be designed with an in-situ replaceable photo-cathode.

43 PARTICLE ACCELERATORS↗

Design of a Cryogenic Scintillation Neutrino Detector at the Spallation Neutron Source

We successfully verified in the following three aspects the feasibility of using a cryogenic scintillating crystal-based neutrino detector at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory, for the detection of low-mass dark matter particles and non-standard neutrino interactions (NSIs), as part of the detector R&D effort of the COHERENT experiment. First, we demonstrated the possibility of using silicon photomultipliers (SiPMs) at cryogenic temperatures to replace traditional photomultiplier tubes (PMTs) as light sensors. Second, we verified that the high light yield of undoped CsI crystals measured above 13 keVee at 77 K still holds down to 5.9 keVee. Third, we successfully measured nuclear quenching factor of undoped cryogenic CsI at the Triangle Universities Nuclear Laboratory with the help from our Duke collaborators. The first achievement resulted in a publication in European Physics Journal C. The second resulted in an arXiv pre-print, which is under journal review. The last one indicates that the performance of the proposed detector may be better than what was assumed in the literature. The analysis is in the final stage and will result in another journal publication. In addition, two graduate students involved in this project graduated with master’s degrees during the project period. Both decided to continue their research as PhD students. One open-source data analysis code package was created and is publicly available on GitHub. A set of tutorials about Monte Carlo simulation of radiation interacting with detectors were created on YouTube, receiving more than 100,000 views.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The D-D Neutron Generator as an Alternative to Am(Li) Isotopic Neutron Source in the Active Well Coincidence Counter

The 235 U mass assay of bulk uranium items, such as oxide canisters, fuel pellets, and fuel assemblies, is not achievable by traditional gamma-ray assay techniques due to the limited penetration of the item by the characteristic 235 U gamma rays. Instead, fast neutron interrogation methods such as active neutron coincidence counting must be used. For international safeguards applications, the most commonly used active neutron systems, the Active Well Coincidence Counter (AWCC), Uranium Neutron Collar (UNCL) and 252 Cf Shuffler, rely on fast neutron interrogation using an isotopic neutron source [i.e., 252 Cf or Am(Li)] to achieve better measurement accuracies than are possible using gamma-ray techniques for high-mass, high-density items. However, the Am(Li) sources required for the AWCC and UNCL systems are no longer manufactured, and newly produced systems rely on limited supplies of sources salvaged from disused instruments. The 252 Cf shuffler systems rely on the use of high-output 252 Cf sources, which while still available have become extremely costly for use in routine operations and require replacement every five to seven years. Lack of a suitable alternative neutron interrogation source would leave a potentially significant gap in the safeguarding of uranium processing facilities. In this work, we made use of Oak Ridge National Laboratory’s (ORNL’s) Large Volume Active Well Coincidence Counter (LV-AWCC) and a commercially available deuterium-deuterium (D-D) neutron generator to examine the potential of the D-D neutron generator as an alternative to the isotopic sources. We present the performance of the LV-AWCC with D-D generator for the assay of 235 U based on the results of Monte Carlo N-Particle (MCNP) simulations and measurements of depleted uranium (DU), low enriched uranium (LEU), and highly enriched uranium (HEU) items.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-H-204-00: History Committee Symposium

“William D. Coolidge, Inventor of the Modern X-ray Tube” David J. Allard, M.S., CHP - Director, PA DEP Bureau of Radiation Protection William David Coolidge 1873–1975 was a research scientist and inventor of the modern X-ray tube. Besides Roentgen, with his 1895 discovery and subsequent studies of X-rays, perhaps no other individual contributed more to the advancement of X-ray technology than did Coolidge. He was born in Hudson, MA and received his Bachelor of Science degree from MIT in 1896. That same year he went to Europe to study under renowned physicists of the time. Coolidge received his Ph.D. summa cum laude from the University of Leipzig in 1899 and soon after joined the staff of MIT. While studying at Leipzig, he met Roentgen. In 1905 he was asked to join the newly established General Electric Research Laboratory in Schenectady, NY. He promptly began fundamental work on the production of ductile tungsten filaments as a replacement for fragile carbon filaments used in incandescent light bulbs. This improved light bulb was brought to market by GE in 1911. It was subsequent application of his tungsten work that led Coolidge to his studies in X ray production. Circa 1910, the state-of-the-art X-ray tube was a “gas tube” or “cold cathode” type tube. These crude X-ray tubes relied on residual gas molecules as a source of electrons for bombardment of low to medium atomic number metal targets. In 1912 Coolidge described the use of tungsten as an improved anode target material for X-ray tubes. Shortly after in 1913 he published a paper in Physical Review describing “A Powerful Roentgen Ray Tube With a Pure Electron Discharge.” This tube used a tungsten filament as a thermionic source of electrons under high vacuum to bombard a tungsten anode target. Great improvements in X-ray tube stability, output and performance were obtained with the “hot cathode” or “Coolidge tube.” With some variation in filament and target geometry, this 100 year old invention is the same basic X-ray tube used today in medicine, research and industry. In 1932 Coolidge became Director of the GE Laboratory, then in 1940 Vice-President and Director of Research. In 1941 he was a member of a small committee, appointed by President Franklin D. Roosevelt, to evaluate the military importance of research on uranium. This committee’s report led to the establishment of the Manhattan Engineering District for nuclear weapons development during WWII. Coolidge lived to be over 100 years old, he had 83 patents to his credit, numerous awards and honorary degrees, and in 1975 was elected to the National Inventor’s Hall of Fame. At the time he was the only inventor to receive this honor in his lifetime. Dr. Coolidge was also the first recipient of the AAPM’s highest science award - named in his honor. From notes of a day-long interview with Coolidge’s son Lawrence in the mid-1990s, previous biographies, publications, books, GE literature, historic photographs, e.g., a wonderful 1874 photo stereoview card with 1 year old baby “Willie Coolidge”, and other artifacts in the author’s collection, this presentation will review Dr. Coolidge’s amazing life, work, accomplishments and awards. “History and Archives Resources at AIP for AAPM and its Members” Gregory A. Good, Ph.D. - Director, AIP Center for History of Physics Melanie J. Mueller, MLIS - Acting Director, AIP Niels Bohr Library & Archives The American Institute of Physics established the Center for History of Physics and the Niels Bohr Library & Archives in the 1960s. Our shared mission is: To preserve and make known the history of the physical sciences. This talk will explore the many ways that AIP’s two history programs support the historical and archival activities of AAPM. Topics will include our ongoing oral history program, web outreach through exhibits and teaching guides, and archiving for AAPM and other Member Societies. We will focus in particular on materials in our collections related to the history of medical physics and to the history of AAPM. We will unveil and demonstrate a new “Archives Portal” that we are designing specifically to be useful to AAPM and its members. Learning Objectives: Study the background of the medical physicist - William David Coolidge Examine the time-line for his success Review the publications conceptualizing his works and progressions Realize what he invented Evaluate the importance of the invention Relate the success to national prominence Uncover how he influenced medical physicists today Find out how he was celebrated by the AAPM View the AIP established Center for History of Physics Consider the significant efforts and vision to preserve the history of medical physics Learn about the Niels Bohr Library & Archives Look back in time at medical physics in the 1960s Unveil and demonstrate a new “Archives Portal” that will be useful to AAPM.

61 RADIATION PROTECTION AND DOSIMETRY↗