Sources of radiation with relativistic streaming
Time variations and angular collimation of radiation emitted by source with relativistic streaming
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Time variations and angular collimation of radiation emitted by source with relativistic streaming
A disrupter to a target may be precisely aimed by positioning a radiation source to direct radiation towards the target, and a detector is positioned to detect radiation that passes through the target. An aiming device is positioned between the radiation source and the target, wherein a mechanical feature of the aiming device is superimposed on the target in a captured radiographic image. The location of the aiming device in the radiographic image is used to aim a disrupter towards the target.
GADRAS is a general purpose application for the modeling and analysis of radiation detector responses, primarily gamma spectroscopic instruments and neutron detectors based on proportional counters. It employs radiation source and detector response models to predict the response of user-defined detectors to user-defined sources. It implements methods to identify radiation sources from their measured signatures, primarily the measured gamma spectrum and neutron count rate. Radiation source emissions are calculated using analytical and numerical radiation transport models. Detector responses are calculated using point models of the detector material, dimensions, collimation, and scattering environment. Analytical methods are implemented using linear and nonlinear regression techniques.
Here we demonstrate a contextually aware multimodal roadside radiation measurement detection testbed for traffic monitoring applications in nuclear nonproliferation. Many variables in traffic such as vehicle or cargo size, mass, speed, shape, and distance of closest approach can have significant impacts on the radiation measured from a vehicle-transported radiation source. These factors can lead to uncertainties in the analysis of the radiation source, especially for lower-strength radiation sources of interest. Our testbed, known as the Multimodal Measurement System (MMS) uses non-radiation sensors including magnetometers, geophones, radiofrequency receivers, cameras, and LiDAR to extract contextual information about vehicles passing by the system. These contextual data can then be fused with data from radiation measurements to increase the system’s sensitivity and accuracy in nuclear threat detection applications. This work describes the instrumentation of the MMS and its data acquisition pipeline. Furthermore, we describe the pre-analysis performed on the raw multimodal data streams for data fusion, and the high-level machine learning analyses for detection and characterization. The variety of sensors within the MMS provides a valuable testbed that can be used to identify the combinations of contextual sensors that provide the greatest improvements to radiation source detection and characterization within the restrictions for various proliferation detection applications. The MMS is also modular so that additional combinations of sensors can be explored in the future.
Purpose: The concept separates the mechanical connection between the radiation source and detector. This design allows the trajectory and orientation of the radiation source/detector to be customized to the object that is being imaged. This is in contrast to the formulaic rotation-translation image acquisition of conventional computed tomography(CT).Background/significance:CT devices that image a full range of: anatomy, patient populations, and imaging procedures are large. The root cause of the expanding size of comprehensive CT is due to the commitment to helical geometry that is hardwired into the image reconstruction. FGCT extends the application of alternative reconstruction techniques, i.e. tomosynthesis, by separating the two main components— radiation source and detector— and allow for 6 degrees of freedom motion for radiation source, detector, or both. The image acquisition geometry is then tailored to how the patient/object is positioned. This provides greater flexibility on the position and location that the patient/object is being imaged. Additionally, removing the need of a rotating gantry reduces the footprint so that CT is more mobile and more available to move to where the patient/object is at, instead of the other way around. Methods: As proof-of-principle, a reconstruction algorithm is designed to produce FGCT images. Using simulated detector data, voxels intersecting a line drawn between the radiation source and an individual detector are traced and modified using the detector signal. The detector signal is modified to compensate for changes in the source to detector distance. Adjacent voxels are modified in proportion to the detector signal, providing a simple image filter. Results: Image-quality from the proposed FGCT reconstruction technique is proving to be a challenge, producing hardily recognizable images from limited projections angles. Conclusion: Preliminary assessment of the reconstruction technique demonstrates the inevitable tradeoff of producing meaningful image-quality verses the practicality of how to obtain sufficient image data.
Provide overview of Space Radiation Sources, Environments, Interactions with Electronic Devices - Radiation Sources - Solar Energetic Particles (SEP) and Solar Particle Events (SPE) - Galactic Cosmic Rays (GCR) - Radiation Environments - Van Allen belts - Beyond the belts - Reference SLS-SPEC-159 Rev G: Design Specification for Natural Environment (DSNE) - Interactions with Electronic Devices - Ionizing - Nonionizing - Internal Charging
Systems and methods for controlling optical feedback in an optical system. A resonant optical cavity includes at least two cavity mirrors, one of which is a cavity coupling mirror, and has a plurality of optical resonance cavity modes. A radiation source emits a beam of continuous wave radiation and is capable of being scanned whereby a mean optical frequency of the continuous wave radiation beam is adjustable over a range of frequencies, wherein the radiation source is responsive to optical feedback radiation emerging from the cavity, and wherein the mode matching optics couples the beam of continuous wave radiation to the cavity via the cavity coupling mirror. The radiation source and the mode matching optics are aligned so that a mode fill ratio is reduced relative to a maximum mode fill ratio, wherein the laser beam is coupled with a fundamental cavity mode.
Purpose: To propose a novel radiation therapy (RT) delivery modality: locally targeted delivery of micron-size RT sources by using temperature-sensitive hydrogel (RT-GEL) as an injectable vehicle. Methods and Materials: Hydrogel is a water-like liquid at room temperature but gels at body temperature. Two US Food and Drug Administration-approved polymers were synthesized. Indium-111 (In-111) was used as the radioactive RT-GEL source. The release characteristics of In-111 from polymerized RT-GEL were evaluated. The injectability and efficacy of RT-GEL delivery to human breast tumor were tested using animal models with control datasets of RT-saline injection. As proof-of-concept studies, a total of 6 nude mice were tested by injecting 4 million tumor cells into their upper backs after a week of acclimatization. Three mice were injected with RT-GEL and 3 with RT-saline. Single-photon emission computed tomography (SPECT) and CT scans were performed on each mouse at 0, 24, and 48 h after injection. The efficacy of RT-GEL was determined by comparison with that of the control datasets by measuring kidney In-111 accumulation (mean nCi/cc), representing the distant diffusion of In-111. Results: RT-GEL was successfully injected into the tumor by using a 30-gauge needle. No difficulties due to polymerization of hydrogel during injection and intratumoral pressure were observed during RT-GEL injection. No back flow occurred for either RT-GEL or RT-saline. The residual tumor activities of In-111 were 49% at 24 h (44% at 48 h, respectively) for RT-GEL and 29% (22%, respectively) for RT-saline. Fused SPECT-CT images of RT-saline showed considerable kidney accumulation of In-111 (2886%, 261%, and 262% of RT-GEL at 0, 24, and 48 h, respectively). Conclusions: RT-GEL was successfully injected and showed much higher residual tumor activity: 170% (200%, respectively), than that of RT-saline at 24 h (48 h, respectively) after injection with a minimal accumulation of In-111 to the kidneys. Preliminary data of RT-GEL as a delivery modality of a radiation source to a local tumor are promising.
SRF photoelectron guns offer the promise of high brightness, high average current beam production for the next generation of accelerator driven light sources such as free electron lasers, THz radiation sources or energy-recovery linac driven synchrotron radiation sources. In a first step a fully superconducting RF (SRF) photoelectron gun is under development by a collaboration between HZB, DESY, JLAB, BNL and NCBJ. The aim of the experiment is to understand and improve the performance of a Nb SRF gun cavity coated with a small metallic Pb cathode film on the cavity backplane. This paper describes the highlights from the commissioning and beam parameter measurements. The main focus is on lessons learned from operation of the SRF gun.
Sources, biophysical characteristics, and potential biological effects of rf radiation are described. Standards are given for exposure of spacecraft personnel to rf radiation.
Applications to radiation oncology in the United States have decreased the past 3 years, resulting in unfilled residency positions (30 [14.5%] in 2019 and 35 [18.5%] in 2020). The aim of this study is to understand the concerns among radiation oncology applicants and whether these concerns may have led to a decline in applications.
Relativistic formulation of radiation for sources in uniformly moving isotropic dispersionless conducting medium in terms of Green functions
A multiwavelength technique was developed and applied to measure the temperatures of nongray surfaces. The instruments required are a spectral radiometer, a dedicated auxiliary radiation source, and a computer. In general, three radiation spectra are recorded: (1) spectrum S sub 0 of the auxiliary radiation source; (2) spectrum S sub 1 of the surface-emitted radiation; and (3) spectrum S sub 2, the sum of the radiation of S sub 1 plus the reflected radiation due to the incidence of the auxiliary radiation source on the surface. Subtracting spectrum S sub 1 from spectrum Sub 2 yields the reflection spectrum resulting from the incidence radiation. From these spectra, a quantity z(lambda) is derived and is related to the reflectivity r(lambda) by r(lambda) = z(lambda)/f, where f is a constant. Spectrum S sub 1 is represented mathematically as the product of a wavelength-dependent emissivity obtained from Kirchhoff's law and a Planck function of temperature T. Application of two-variable (lambda and z), nonlinear, least-squares curve-fitting computer software to fit spectrum S sub 1 to this mathematical expression yielded the surface temperature. This technique also measured the spectral reflectivity and emissivity of the surface. Instrumentation necessary to extend measurement to elevated temperatures and in the presence of reflective interference is discussed.
Photonic materials designed at wavelength scales have enabled a range of emerging energy technologies, from solid-state lighting to efficient photovoltaics that have transformed global energy landscapes. Daytime passive radiative cooling materials shed heat from the ground to the cold universe by taking advantage of the terrestrial thermal radiation that is as large as the renewable solar energy. Newly developed photonic materials permit subambient cooling under direct sunshine, and their applications are expanding rapidly enabled by scalable manufacturing. We review here the recent advancement of daytime subambient radiative cooling materials, which allow energy-efficient cooling and are paving the way toward technologies that harvest the coldness from the universe as a new renewable energy source.
The geometrical-optical properties of synchrotron radiation coming from a curving, relativistic electron beam do not fit into any usual category of light or radiation source, The center of the apparent source of radiation depends on the position of the observer with respect to the orbit, and the source has an axial extent which is a function of the sizes of the beam and the observation aperture. The beam image formed by focusing the synchrotron light is subject to distortions and depth of field errors. These errors are calculated, and, in some cases, methods of correction are given. The limits put on resolution by geometrical effects are given. Beam orbit changes cause errors in the angular acceptance of observation systems: these effects can also be corrected. Furthermore the dimensions of the diffuse shadows cast by rays from the finite-sized source impinging on edges are calculated.
Radiators using a graphite heating element as a radiant heat source have high heat flux and long operational lives. They are used to test the thermal resistance of materials.
The spatial resolution of a flash radiograph is determined by the time-integrated size of the radiation source. Since the radiation pulse includes the beam head and tail, which may be substantially larger than the beam body, the radiation source is larger than the focused flattop of the electron beam pulse. Moreover, the radiation dose rate is weighted by both beam current and electron energy, and it is the radiation dose that forms the radiograph image. Therefore, in order to estimate radiographic resolution from computer simulations of a focused electron beam, one should use a dose weighted moment analysis of the radiation source distribution. This approach is used to show that, in the absence of beam effects other than space-charge and emittance, radiographic resolution for Scorpius exceeds requirements, regardless of reasonable timing options for current and gap-voltage pulses.
A system and method for determining the shielding thickness of a detected radiation source. The gamma ray spectrum of a radiation detector is utilized to estimate the shielding between the detector and the radiation source. The determination of the shielding may be used to adjust the information from known source-localization techniques to provide improved performance and accuracy of locating the source of radiation.