Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Transport Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Preconceptual Design of Irradiated Fuel Salt Management System

The National Reactor Innovation Center was established by the U.S. Department of Energy to accelerate the demonstration and deployment of advanced nuclear reactors. To meet this mission, the National Reactor Innovation Center has developed the Laboratory for Operations and Testing in the U.S. (LOTUS) to support the first fast-spectrum molten salt reactor demonstration. The goal of this research is to understand the system requirements that may be applied to a molten salt reactor experiment in the LOTUS test bed and to perform systems analyses and preconceptual development of a storage container for the management of the irradiated molten salt fuel. This study proposes a set of irradiated fuel salt management processes for the molten salt reactor, from defueling to storage or disposal. For that, the historic Molten Salt Reactor Experiment (MSRE) at Oak Ridge National Laboratory has served as a crucial source of data for a mock application. This paper proposes a potential geometry for storing irradiated fuel salt based on MSRE data and the Monte Carlo N-Particle radiation transport code. The geometry was analyzed for criticality safety under abnormal situations, such as water ingress and interaction between containers. Based on the determined configuration of the storage system, the decay heat produced from the irradiated fuel salts was calculated to provide a reasonable time scale of the dormancy period. Using the same geometry assumed above, the neutron and gamma dose rates from the irradiated fuel salt at the end of the dormancy period were estimated, which will be useful for understanding the handling and radiation protection requirements for handling the irradiated fuel salt. Lastly, a reactor in the LOTUS test bed could use chloride-based fuel as opposed to the fluoride-based fuel used in MSRE. Thus, a literature study provided data to understand the similarities and differences between the characteristics of fluoride- and chloride-based salts in terms of salt chemistry, material characteristics, postirradiation behavior, neutronics, thermal hydraulics, and heat removal. This study, together with the proposed irradiated fuel salt management processes, preliminary criticality calculations, decay heat, and dose rate estimates, provides a strong basis for future investigation into the management of irradiated fuel salts generated during molten salt reactor technology demonstrations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lunar Nuclear Reactor Neutron Fluence and Gamma Dose Estimates

NASA aims to deploy a fission reactor on the lunar surface by 2030 to generate 100 kWe of power for at least 10 years without maintenance or refueling. To assess system and subsystem survivability according to those requirements, a model of the reactor pallet was created in the radiation transport code MCNP to determine the neutron fluences and gamma doses that the materials and systems would be exposed to. The model was based on the 2025 government design. The model indicated that the control drum motors, Brayton cycle engines, and pipes and valves would be exposed to neutron fluences of 1×10 15 – 1×10 16 n/cm 2 per year and gamma doses ranging from 10 to 500 Mrad per year. The electronics box housing the instrumentation and control elements is expected to receive 1×10 14 – 1×10 15 n/cm 2 per year and gamma doses in the range of 1–5 Mrad per year. These doses necessitate that the control drum motors, Brayton cycle engines, valve components, control electronics, and other components be radiation-hardened (>10 16 n/cm 2 and >10 Mrad gamma dose) or additionally shielded to survive the 10-year lunar mission.

Radiation-Hardened Materials↗

Packaging Certification program Methodology for Determining Dose Rates for Small Gram Quantities in Shipping Packagings

The Small Gram Quantity (SGQ) concept is based on the understanding that small amounts of hazardous materials, in this case radioactive materials (RAM), are significantly less hazardous than large amounts of the same materials. This paper describes a methodology designed to estimate an SGQ for several neutron and gamma emitting isotopes that can be shipped in a package compliant with 10 CFR Part 71 external radiation level limits regulations. These regulations require packaging for the shipment of radioactive materials, under both normal and accident conditions, to perform the essential functions of material containment, subcriticality, and maintain external radiation levels within the specified limits. By placing the contents in a helium leak-tight containment vessel, and limiting the mass to ensure subcriticality, the first two essential functions are readily met. Some isotopes emit sufficiently strong photon radiation that small amounts of material can yield a large dose rate outside the package. Quantifying the dose rate for a proposed content is a challenging issue for the SGQ approach. It is essential to quantify external radiation levels from several common gamma and neutron sources that can be safely placed in a specific packaging, to ensure compliance with federal regulations. The Packaging Certification Program (PCP) Methodology for Determining Dose Rate for Small Gram Quantities in Shipping Packagings provides bounding shielding calculations that define mass limits compliant with 10 CFR 71.47 for a set of proposed SGQ isotopes. The approach is based on energy superposition with dose response calculated for a set of spectral groups for a baseline physical packaging configuration. The methodology includes using the MCNP radiation transport code to evaluate a family of neutron and photon spectral groups using the 9977 shipping package and its associated shielded containers as the base case. This results in a set of multipliers for 'dose per particle' for each spectral group. For a given isotope, the source spectrum is folded with the response for each group. The summed contribution from all isotopes determines the total dose from the RAM in the container.

42 ENGINEERING↗

Babcock & Wilcox Critical Experiment Calculations to Support MPACT Verification

This report describes a series of benchmark calculations performed using the method of characteristics radiation transport code MPACT to verify its radial transport and axial buckling calculation capabilities. The benchmarks are based on a series of Babcock & Wilcox critical assembly configurations analyzed in what are commonly known as the B&W-1484 benchmark experiment and the B&W-1810 benchmark experiment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of the On-the-Fly Shielding Analysis Method: Spent Fuel and Waste Disposition

This report documents work performed supporting the US Department of Energy (DOE) Office of Nuclear Energy (NE) Spent Fuel and Waste Disposition (SFWD) Integrated Waste Management activities under work breakdown structure element 1.08.02.04.01, “Data and Tools Development, Validation, and Maintenance.” In particular, this report fulfills milestone M3SF-21OR020401016, “Implement on-the-fly dose analysis methodology in UNF-ST&DARDS” within work package SF-21OR02040101, “Commercial SNF Characterization - ORNL.” The Used Nuclear Fuel - Storage, Transportation & Disposal Analysis Resource and Data System (UNFST& DARDS) enables automated dose rate calculations for spent nuclear fuel (SNF) transportation packages and storage casks using a Monte Carlo radiation transport code. The explicit method uses a detailed model of the SNF system and its contents. Therefore, a dose rate calculation is required for each as-loaded transportation package or storage cask because the SNF assemblies within a canister typically have unique irradiation characteristics. An alternate method, referred to as the “on-the-fly” shielding analysis method, has been proposed that requires only a set of Monte Carlo dose rate calculations for each transportation packaging/storage cask design. The results of the Monte Carlo dose rate calculations are independent of the SNF assembly irradiation and decay characteristics. The dose rate values may then be combined with the radiation source strength of the SNF assemblies associated with a particular transportation packaging/storage cask design to determine actual dose rates. This report presents on-the-fly dose rate calculations for a representative SNF storage cask and verification of the on-the-fly dose rate calculation results by comparison with reference dose rate calculations using the explicit Monte Carlo dose rate calculation. The on-the-fly shielding analysis method was implemented in UNF-ST&DARDS. A Python program was developed to process the MAVRIC dose rate results obtained by source particle type, energy group, and fuel geometry region. A Python processor created binary files, which were saved as a special UNF-ST&DARDS library for on-the- fly shielding analyses. UNF-ST&DARDS uses the precalculated on-the-fly binary libraries generated by the Python data processor and directly executes the Python code for on-the-fly dose analysis. This Python code unzips the pre-generated binary files mentioned above, reads the data, and combines them with user-specified sources for dose and uncertainty calculations. The Python programs were verified using Excel calculations and by comparison with the values obtained with the MAVRIC post-processing utilities applied to the 3dmap files. This method can currently be used to determine dose rates for as-loaded HI-STORM FW storage casks. The UNF-ST&DARDS analysis wizard for on-the-fly shielding analysis is described in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dosimetric characterization of round HDR {sup 192}Ir AccuBoost applicators for breast brachytherapy

Purpose: The AccuBoost brachytherapy system applies HDR {sup 192}Ir beams peripherally to the breast using collimating applicators. The purpose of this study was to benchmark Monte Carlo simulations of the HDR {sup 192}Ir source, to dosimetrically characterize the round applicators using established Monte Carlo simulation and radiation measurement techniques and to gather data for clinical use. Methods: Dosimetric measurements were performed in a polystyrene phantom, while simulations estimated dose in air, liquid water, polystyrene and ICRU 44 breast tissue. Dose distribution characterization of the 4-8 cm diameter collimators was performed using radiochromic EBT film and air ionization chambers. Results: The central axis dose falloff was steeper for the 4 cm diameter applicator in comparison to the 8 cm diameter applicator, with surface to 3 cm depth-dose ratios of 3.65 and 2.44, respectively. These ratios did not considerably change when varying the phantom composition from breast tissue to polystyrene, phantom thickness from 4 to 8 cm, or phantom radius from 8 to 15 cm. Dose distributions on the central axis were fitted to sixth-order polynomials for clinical use in a hand calculation spreadsheet (i.e., nomogram). Dose uniformity within the useful applicator apertures decreased as depth-dose increased. Conclusions: Monte Carlo benchmarking simulations of the HDR {sup 192}Ir source using the MCNP5 radiation transport code indicated agreement within 1% of the published results over the radial/angular region of interest. Changes in phantom size and radius did not cause noteworthy changes in the central axis depth-dose. Polynomial fit depth-dose curves provide a simple and accurate basis for a nomogram.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cost-optimized Automated Variance Reduction for Highly Angle-dependent Radiation Transport Analyses [Dissertation]

Monte Carlo variance-reduction techniques that directly bias particle direction have historically received limited attention despite being useful for many radiation transport applications such as those in which radiation travels through large regions with a low probability of colliding. One such technique is known as DXTRAN (short for deterministic transport) in the MCNP Monte Carlo radiation transport code. Until now, effectively applying DXTRAN in calculations is largely based on empirical observations of computational performance. Optimal DXTRAN parameters are identified through manual iteration. This work develops new mathematical descriptions of the DXTRAN variance-reduction process and demonstrates a new automated variance-reduction method that applies these mathematical formulations to determine the optimal application of DXTRAN in a given problem.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generating Models of the Flattop Critical Assembly for Benchmark Experiments with Python

Los Alamos National Laboratory has been performing nuclear criticality experiments since 1946 at the Pajarito site, starting the Los Alamos Critical Experiments Facility in 1948. A transition period occurred between 2004 and 2011 as operations moved to the National Criticality Experiments Research Center (NCERC), where criticality experiments are now performed. Criticality experiments are essential for determination and verification of nuclear data used in calculations and modeling—such as radiation transport codes—throughout the industry, enhancing nuclear criticality safety. In addition to nuclear data validation and benchmarking, the remotely operated critical assemblies at NCERC are used for a variety of experiments and training classes supporting criticality safety.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a mixed high-energy spallation neutron–proton field using monoisotopic activation detectors

In this paper, we used monoisotopic Co, Au, and Bi threshold activation detectors to characterize the high-energy ( > 5 MeV) portion of a mixed spallation neutron–proton (n/p) field. The field was produced by irradiating the natural uranium target–blanket subcritical assembly Quinta with 660-MeV protons from Phasotron accelerator at the Joint Institute for Nuclear Research (JINR) in Dubna. Experimental yields of the (n,x) and (p,x) reactions were compared to the calculated reaction rates, which represent the convolution of particle flux and reaction cross section. The flux was simulated using the radiation transport code MCNPX 2.7.0, and the cross sections were extracted from the following three sources: the intranuclear cascade model INCL4.2, the phenomenological spherical optical model from TALYS-1.8, and the evaluated nuclear data file TENDL-2015. We show that, in most cases, the evaluated data provide a closer agreement with the experimental data in comparison with INCL4.2 model, which is an integral part of MCNPX. Finally, our results bring a contribution to those fields of physics research that utilize computer prediction of neutron generation in the energy range of tens to hundreds MeV, such as the medical radioisotope production, radiation shielding of spallation neutron sources, and nuclear transmutation in accelerator-driven systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Nonequilibrium Molecular Nitrogen Ultraviolet Radiation in Pure N2 Shockwaves

This paper presents an analysis of data previously reported from a test series in the Electric Arc Shock Tube Facility for incident shocks composed of pure Nitrogen. The present work focuses on the lowest velocity measured in the test (approximately 7 km/s) where molecular radiation is significant. Analysis of the spectral data with the NEQAIR radiative transport code obtains post-shock trends in temperature and number densities of the states of N2. The results suggest that chemical, and possibly thermal, equilibrium has not been obtained within the distance/time measured (about 5 cm/120 s). In the nonequilibrium region of the shock, differences between rotational temperatures of different species are observed, as well as differences between rotational and vibrational temperatures. Population of rotational states above the dissociation limit is observed to occur over a distance of several cm. Finally, these data suggest that predissociation strongly affects the C^3 Π_u state of N2, leading to a lower measured radiation than predicted. An effective average pre-dissociation rate is shown to produce reasonable agreement under quasi-steady state approximation.

Augustin Tibere Inglesse↗

Analysis of nonequilibrium molecular nitrogen ultraviolet radiation in pure N2 shockwaves

An analysis of data previously reported from a test series in the Electric Arc Shock Tube Facility for incident shocks composed of pure Nitrogen was performed. The present work focuses on the lowest velocity measured in the test (approximately 7 km/s) where molecular radiation is significant. Analysis of the spectral data with the NEQAIR radiative transport code obtains post-shock trends in temperature and number densities of the states of N2. The results suggest that chemical, and possibly thermal, equilibrium has not been obtained within the distance/time measured (about 5 cm/120 ms). In the nonequilibrium region of the shock, differences between rotational temperatures of different species are observed, as well as differences between rotational and vibrational temperatures. Population of rotational states above the dissociation limit is observed to occur over a distance of several cm. Finally, these data suggest that predissociation strongly affects the C^3 Π_u state of N2, leading to a lower measured radiation than predicted. An effective average pre-dissociation rate is shown to produce reasonable agreement under quasi-steady state approximation.

Augustin Tibere-Inglesse↗

Characteristics of concrete reflection of {sup 235}U systems

Water reflection is considered in nuclear criticality safety evaluations because it is readily available and easily forms a close-fitting reflector around fissile material. Concrete is commonly encountered in industrial environments and can be a more effective reflector than water. A comprehensive study using 32 concrete compositions derived from an extensive literature survey was done for the three basic one-dimensional geometries used in radiation transport codes (spherical, infinite length cylindrical, and infinite extent slab) using a {sup 235}U metal/water fissile mixture. The concentration/moderation range over which criticality is possible was spanned, and the change in k{sub eff} per unit change in element atomic number density for various concrete composition elements was computed to determine the relative effect of each element on neutron multiplication. The results show that: -1) the most effective reflector is not the same for each geometry; -2) in general, for each geometry, Δk{sub eff}/ΔN has similar values for {sup 235}U concentrations >0.200 g/cm{sup 3}; and -3) for {sup 235}U concentrations < 0.200 g/cm{sup 3}, the value of Δk{sub eff}/ΔN diminishes toward zero.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Organ and effective dose coefficients for cranial and caudal irradiation geometries: photons

With the introduction of new recommendations of the International Commission on Radiological Protection (ICRP) in Publication 103, the methodology for determining the protection quantity, effective dose, has been modified. The modifications include changes to the defined organs and tissues, the associated tissue weighting factors, radiation weighting factors and the introduction of reference sex-specific computational phantoms. Computations of equivalent doses in organs and tissues are now performed in both the male and female phantoms and the sex-averaged values used to determine the effective dose. Dose coefficients based on the ICRP 103 recommendations were reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Publication 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT) and isotropic (ISO). In this work, the methodology of ICRP Publication 116 was used to compute dose coefficients for photon irradiation of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace from personnel standing on contaminated surfaces or volumes and from overhead sources. Calculations of organ and tissue kerma and absorbed doses for caudal and cranial exposures to photons ranging in energy from 10 keV to 10 GeV have been performed using the MCNP6.1 radiation transport code and the adult reference phantoms of ICRP Publication 110. As with calculations reported in ICRP 116, the effects of charged-particle transport are evident when compared with values obtained by using the kerma approximation. At lower energies the effective dose per particle fluence for cranial and caudal exposures is less than AP orientations while above similar to 30 MeV the cranial and caudal values are greater.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutron and Gamma Correlations using CGM in MCNP 6.2.0

The general-purpose Monte Carlo radiation-transport code MCNP6{sup TM} came from the integration of MCNP5{sup TM} and MCNPX{sup TM}. The most recent release of MCNP, version 6.2.0, is scheduled for release in early 2017, which includes a variety of bug fixes and new features to the code. MCNP traditionally models nuclear reactions using Monte Carlo sampling techniques on measured and modeled cross-sectional data contained within ACE (A Compact Evaluated Nuclear Data File) libraries. In addition to reaction cross-sections, ACE libraries contain information relating to the production of secondary particles, such as secondary neutrons and photons. For example, an incident neutron on a nucleus can produce a nuclear reaction in the form (n, M{sub n}n'), where n is the incident neutron and M{sub n} is the number of secondary neutrons n' produced. Using this notation, different reactions can be described based on their neutron multiplicity, such as neutron capture (M{sub n} = 0), elastic and inelastic scattering (M{sub n} = 1), and reactions with multiple secondary neutrons (M{sub n} > 1). Accounting for secondary γ-rays emitted from the residual nuclei, this reaction can further be generalized as n, Mnn'M to describe a reaction producing M{sub n} neutrons and M -rays. These values M{sub n} and M are referred to as the neutron and multiplicities, respectively. ACE libraries contain the cross-sectional data for each reaction, and their corresponding statistically averaged multiplicities for neutrons and photons, M-bar{sub n} and M-bar{sub γ}. However, there are several limitations to reaction sampling using ACE libraries. First, the data contained within ACE libraries is limited by the accuracy of the model and/or experiment, which out of necessity can greatly simplify the true physics behind a reaction. For example, the value M{sub γ} in a (n, M{sub n}n'M{sub γ}γ) reaction is determined by the statistically averaged multiplicity M-bar{sub γ} instead of a distribution. Consequently, MCNP, unable to produce a continuous distribution, will utilizes a binary sampling around M-bar{sub γ}. While this sampling method provides a statistically average M{sub γ} over a large simulation, it is an inaccurate representation of an individual reaction and its corresponding secondary particles. Secondary neutrons are affected in a similar manner, such that different kinds of secondary neutrons can be sampled from the same interaction (eg., an inelastic neutron with an [n, 2n] neutron). Lastly, the random sampling technique for secondary particles remains completely independent of the sampled reaction, eliminating the ability to correlate secondary particles for a given reaction. To supplement these data libraries, additional codes and models describing certain nuclear reactions are employed. These codes can fill in the information missing from ACE, provide a better model to the true physics distribution, and can provide true correlated secondary particles, which has many useful applications in research and industry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Passive neutron coincidence counting with plastic scintillators for the characterization of radioactive waste drums

The quantification of radioactive material is essential in the fields of safeguards, criticality control of nuclear processes, dismantling of nuclear facilities and components, or radioactive waste characterization. The Nuclear Measurement Laboratory (LMN) of CEA is involved in the development of time-correlated neutron detection techniques using plastic scintillators. Usually, 3He proportional counters are used for passive neutron coincidence counting owing to their high thermal neutron capture efficiency and gamma insensitivity. However, the global {sup 3}He shortage in the past few years has made these detectors extremely expensive. In addition, contrary to {sup 3}He counters for which a few tens of microseconds are needed to thermalize fast neutrons, in view to maximize the {sup 3}He(n,p){sup 3}H capture cross section, plastic scintillators are based on elastic scattering and therefore the light signal is formed within a few nanoseconds, correlated pulses being detected within a few dozen- or hundred nanoseconds. This time span reflects fission particles time of flight, which allows reducing accordingly the duration of the coincidence gate and thus the rate of random coincidences, which may totally blind fission coincidences when using {sup 3}He counters in case of a high (α,n) reaction rate. However, plastic scintillators are very sensitive to gamma rays, requiring the use of a thick metallic shield to reduce the corresponding background. Cross talk between detectors is also a major issue, which consists on the detection of one particle by several detectors due to elastic or inelastic scattering, leading to true but undesired coincidences. Data analysis algorithms are tested to minimize cross-talk in simultaneously activated detectors. The distinction between useful fission coincidences and the correlated background due to cross-talk, (α,n) and induced (n,2n) or (n,n'γ) reactions, is achieved by measuring 3-fold coincidences. The performances of a passive neutron coincidence counting system for radioactive waste drums using plastic scintillators have been studied using the Monte Carlo radiation transport code MCNPX-PoliMi v2.0 coupled to data processing algorithms developed with ROOT data analysis software. In addition to the correlated background, accidental coincidences are taken into account in the simulation by randomly merging pulses from different calculations with fission and (α,n) sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of two different radioactive sources for prostate brachytherapy treatment

In this study we evaluated two radioactive sources for brachytherapy treatments. Our main goal was to quantify the absorbed doses on organs and tissues of an adult male patient, submitted to a brachytherapy treatment with two radioactive sources. We evaluated a {sup 192}Ir and a {sup 125}I radioactive sources. The {sup 192}Ir radioactive source is a cylinder with 0.09 cm in diameter and 0.415 cm long. The {sup 125}I radioactive source is also a cylinder, with 0.08 cm in diameter and 0.45 cm long. To evaluate the absorbed dose distribution on the prostate, and other organs and tissues of an adult man, a male virtual anthropomorphic phantom MASH, coupled in the radiation transport code MCNPX 2.7.0, was employed.We simulated 75, 90 and 102 radioactive sources of {sup 125}I and one of {sup 192}Ir, inside the prostate, as normally used in these treatments, and each treatment was simulated separately. As this phantom was developed in a supine position, the displacement of the internal organs of the chest, compression of the lungs and reduction of the sagittal diameter were all taken into account. For the {sup 192}Ir, the higher doses values were obtained for the prostate and surrounding organs, as the colon, gonads and bladder. Considering the {sup 125}I sources, with photons with lower energies, the doses to organs that are far from the prostate were lower. All values for the dose rates are in agreement with those recommended for brachytherapy treatments. Besides that, the new seeds evaluated in this work present usefulness as a new tool in prostate brachytherapy treatments, and the methodology employed in this work may be applied for other radiation sources, or treatments. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Critical Simulation Pipeline for COG Suites [Poster]

The CRItical Simulation Pipeline (CRISP) is a Python package for automating validation of reactor criticality benchmarks. CRISP supplies COG—a multi-particle radiation transport code maintained by the Nuclear Criticality Safety Division—with a pipeline to calculate k eff performance for 400+ benchmark experiments with 3,400+ configurations from the International Criticality Safety Benchmark Evaluation Project (ICSBEP). The pipeline includes four stages: materials configuration, input card templating, cluster submission, and results analysis. CRISP includes a command-line interface to facilitate user interaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MCNP6 enhancements of delayed-particle production

Over the last decade, there has been an increased interest in the production of delayed-particle signatures from neutron and photon interactions with matter. To address this interest, various radiation transport codes have developed a wide range of delayed-particle physics packages. With the recent merger of the Monte Carlo transport codes MCNP5 and MCNPX, MCNP6 inherited the comprehensive model-based delayed-particle production capabilities developed in MCNPX over the last few years. An integral part of this capability consists of the depletion code CINDER90 which was incorporated into MCNPX in 2004. During this last year, significant improvements have been made to the MCNP6 physics and algorithms associated with delayed-particle production, including the development of a delayed-beta capability, an algorithm enhancement for the delayed-neutron treatment, and a database enhancement for delayed-gamma emission. The delayed-beta feature represents an important component in modeling background signals produced by active interrogation sources. Combined, these improvements provide MCNP6 with a flexible state-of-the-art physics package for generating high-fidelity signatures from fission and activation. This paper provides details of these enhancements and presents results for a variety of fission and activation examples. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗