Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiator Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Performance and Reliability Assessment of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Data Advisor (ADA)

The Atmospheric Radiation Measurement (ARM) User Facility provides one of the world's largest openly accessible repositories of atmospheric observations through the ARM Data Discovery platform. Although the repository contains more than three decades of measurements collected from permanent observatories, mobile facilities, aircraft campaigns, and field experiments, identifying appropriate datasets can be challenging, particularly for new users unfamiliar with ARM instrumentation and datastream organization. To improve data accessibility, the ARM Data Center developed the ARM Data Advisor (ADA), an artificial intelligence-powered assistant designed to facilitate scientific data discovery, dataset interpretation, and user guidance. This report evaluates ADA's performance as a domain-specific scientific assistant using realistic atmospheric science workflows. The evaluation examines five key capabilities: data retrieval and curation efficiency, hallucination resistance, scientific reasoning, response to ambiguous queries, and content retention and session continuity. Representative prompts were developed to simulate typical interactions between researchers and the ARM Data Discovery platform, and ADA's responses were assessed for retrieval completeness, scientific accuracy, consistency, and practical usefulness. In these representative tests, ADA reduced the complexity of discovering and accessing ARM datasets by recommending appropriate datastreams, explaining instrumentation, interpreting metadata, and assisting with data processing workflows. ADA also exhibits strong domain knowledge of atmospheric science terminology and generally resists hallucination by acknowledging unavailable datasets and requesting clarification when appropriate. Overall, the results indicate that ADA represents a promising advancement in scientific data discovery within the ARM User Facility and has considerable potential to improve researcher productivity, particularly for new users and interdisciplinary scientists seeking efficient access to ARM observations.

Salvador, Christian [ORNL] (ORCID:0000000283287777↗

Feedback between radiation and transport in photovoltaics

By building on the generalized Hovel model, this work develops an analytical solution to unify photon recycling, light trapping, and carrier transport in solar cells. Enhanced transport due to photon recycling diffusion is considered. While photon recycling diffusion is often negligible, it can significantly support transport in cases where charge diffusion is low but radiative efficiency is high. Next, the diffusion equation is solved to determine carrier collection for planar and textured cells. Results elucidate novel features in the external quantum efficiency (EQE) curve that occur for textured cells with high absorption and limited transport. Then, the effect of limited transport on the radiative recombination of solar cells is investigated in detail. While the traditional treatment of detailed balance uses the applied voltage to calculate a cell's radiative recombination, the present approach uses the spatially resolved quasi-Fermi-level splitting (QFLS). Further, the discrepancy between the models is shown to be inconsequential to performance for cells with low radiative recombination (Si) or with high mobilities (lowly doped GaAs). However, for cells with high radiative recombination and low mobility (highly doped GaAs, polycrystalline CdTe, and thin-film perovskites), incorporating variation in QFLS in the determination of radiative recombination can become necessary for accurate photovoltaic modeling.

14 SOLAR ENERGY↗

Radiation Therapy Adherence Among Patients Experiencing Homelessness

Radiation therapy is a valuable, yet time- and resource-intense therapy. Patients experiencing homelessness (PEH) face many barriers related to the timely receipt of radiation therapy. Owing to a paucity of data regarding cancer treatment and homelessness, clinicians have a limited evidence base when recommending therapy to PEH. This study was performed to evaluate adherence to radiation therapy treatment regimens in PEH with cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robustness of the smartpixels classifier for different simulated sensor geometries and non-ideal detector conditions

Pixel tracking detectors at upcoming collider experiments will see unprecedented charged-particle densities. Real-time data reduction on the detector will enable higher granularity and faster readout, possibly enabling the use of the pixel detector in high-rate online event selection, such as the ATLAS or CMS first-level trigger systems. This data reduction can be accomplished with a neural network (NN) in the readout chip bonded with the sensor that recognizes and rejects tracks with low transverse momentum (p T ) based on the geometrical shape of the charge deposition (“cluster”). To design viable detectors for deployment, the dependence of the NN as a function of the sensor geometry, external magnetic field, irradiation, and noise must be understood. In this paper, we present first studies of the efficiency and data reduction for planar pixel sensors exploring these parameters. For the CMS HL-LHC sensor geometry, we obtain a signal efficiency of (91.9 ± 0.7)% and a data reduction of (29.7 ± 1.0)%. A smaller sensor pitch in the bending direction improves the p T discrimination, but a larger pitch can be partially compensated with detector thickness. Any accumulated radiation damage also changes the cluster shape, reducing the signal efficiency compared to the baseline by approximately 30–60% in absolute terms, but nearly all of the performance can be recovered through retraining of the network and updating the weights. Finally, the impact of noise was investigated, and retraining the network on noise-injected datasets was found to maintain performance within 6% of the baseline network trained and evaluated on noiseless data. •ASIC-compatible track-momentum classifier is robust in realistic detector conditions.•About 90% signal efficiency and 30% data reduction per layer for CMS HL-LHC geometry.•Single-layer signal efficiency increases for smaller pixel pitch or thicker sensors.•Performance with noise or after radiation damage mostly recovered by retraining.

Shekar, Danush [Illinois U., Chicago] (ORCID:00000↗

A Vertically Resolved Analysis of Radiative Feedbacks on Moist Static Energy Variance in Tropical Cyclones

Abstract A vertically resolved moist static energy (MSE) variance budget framework is used to diagnose processes associated with the development of tropical cyclones (TCs) in a general circulation model (GCM) under realistic boundary conditions. Previous studies have shown that interactions between radiation and MSE promote TC development. Here, we examine the vertical contributions of radiation and its interactions with MSE by performing several mechanism-denial experiments in which synoptic-scale radiative interactions are suppressed either in the boundary layer or in the free troposphere. Partly suppressing radiative interactions results in a reduction in global TC frequency. However, the magnitude of reduction and structure of the feedback depend on the intensity and structure of the TCs in these mechanism-denial experiments, indicating that both the magnitude and the vertical location of radiative interactions can impact global TC frequency. Using instantaneous 6-hourly outputs, an explicit computation reveals distinct spatial patterns of the advection term: the vertical component is positive in the mid- to upper troposphere, which reflects an upward transport of MSE by deep convection, whereas the horizontal component is positive in the boundary layer. These results illustrate the impact of the vertical distribution of radiative interactions and vertically varied contribution of the advection term in the development of TCs.

Meteorology & Atmospheric Sciences↗

The effect of radiation damage on the light yield and uniformity of candidate plastic scintillator tiles for the CMS hadron calorimeter upgrade

A study has been performed to understand the effects of radiation damage on various plastic scintillator tiles considered for a possible upgrade of the hadron calorimeter of the CMS detector. Measurements were made with unirradiated tiles and with tiles that had been irradiated in the CMS collision hall to a dose of 44 kGy. Results are presented for the tiles of different shapes in terms of the energy spectrum, efficiency as a function of the position at which each tile was hit, as well as light yield. All the tiles showed a light reduction of up to about 50%. The tiles with the shape currently used in the CMS detector did not see increased non-uniformity of light collection, while a significant disuniformity was observed for the tiles considered as alternatives.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of B255 R183 C-Cell Cobalt-60 Irradiator Pool

Characterization of the Radiation Calibration and Spectroscopy Laboratory (RCS) Co-60 source radiation pool was successfully completed. The characterization was done by performing several measurements of dose rate in the center of the Co-60 source radiation pool and at multiple heights from the bottom of the pool. The measurements were taken between November 2018 through January 2019. Opti-Chromic FWT-70-40M dosimeters were used for this measurement. A 7.3 cm inner diameter stainless steel cylinder (vessel) was used to lower the dosimeters to the bottom of the pool inside the 16 cm dimeter Co-60 source basket. The dose rate was measured at heights of 5.5, 12, 19, and 23 cm from the bottom of the pool. The report “Tour of the Standards and Calibration Laboratory” includes information about the Co-60 source radiation pool. The importance of performing the Co-60 source characterization is to confirm previously reported Co-60 source dose rate measurements and to provide a documented measuring procedure for researchers and others who want to use the Co-60 source to evaluate the effects of radiation on space-based equipment for other applications. The measured dose rate at the abovementioned heights was 0.65, 0.69, 0.53, 0.23 krad/min respectively with the highest coefficient of variation of less than 10%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Proton radiation resilience of CdSeTe photovoltaics: High predicted end-of-life performance for space applications

Two types of cadmium selenide telluride (CdSeTe) photovoltaic devices have been exposed to high-energy (150–1500 keV) protons with fluences ranging from 1 × 10 11 to 9 × 10 13 cm −2 . Pre- and post-irradiation current density vs voltage characteristic data were collected and analyzed. Arsenic-doped CdSeTe devices retained 80% of the power conversion efficiency (PCE) relative to control devices after exposure to 10 12 cm −2 650 keV protons, while copper-doped CdSeTe devices retained about 95% of the control PCE under the same irradiation condition. Displacement damage dose analysis coupled with simulations for duration-dependent performance in a medium Earth orbit space mission revealed superior PCE remaining factors, indicating greater resilience to proton bombardment than state-of-the-art multijunction III-V based space photovoltaic technologies.

CdTe solar cells↗

SCALE 6.2.4: Validation Overview

SCALE is a multi-application code system with tools for reactor physics, criticality safety, radiation shielding, and spent fuel characterization for a range of nuclear systems. The last of the SCALE 6.2 series, version 6.2.4, was released in June 2020. Validation studies in nuclear criticality safety, reactor physics, and shielding applications were performed to confirm results, assess accuracy, and identify biases from SCALE simulations. Nuclear criticality safety applications yield small code biases for a wide range of systems, generally overestimating cross section uncertainty. Reactor physics applications improvements in nuclide inventory and full-core eigenvalue predictions, with similar performance in decay heat predictions. Radiation shielding applications yield sufficient agreement in comparisons to measurements and alternate simulations for eight shielding experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi–length scale characterization of point defects in thermally oxidized, proton irradiated iron oxides

A key for the success of safe nuclear power generation system is to consider structural materials that are economical, meet mechanical property needs, possess good corrosion resistance, and are radiation tolerant. Nevertheless, fundamental insights that elucidate the details of radiation damage on materials corrosion performance are lacking. This includes the behavior of surface oxides which often regulate corrosion. For example, it is unclear how non-equilibrium point defects, oxide structure, mass transport in oxides, and subsequent oxidation behavior are altered by the radiation. Here, in this work, some of the effects of proton irradiation on the attributes of point defects, iron oxide microstructures, and the physical nature of the oxidation product were correlated with corrosion behavior. Iron oxides, fabricated by thermal oxidation in air at 400°C and 800°C for 1 h, were subjected to 200 keV, 0.03 dpa (displacements per atom) of proton irradiation, and subjected to corrosion reactivity assessment using AC and DC electrochemical methods. Experimental methods that target materials information at different length scales, such as positron annihilation spectroscopy (atomistic), transmission electron microscopy (mesoscopic), and electrochemical methods (macroscopic), were coupled to shed light on the impact of radiation-induced defect modifications and structural changes in oxides on corrosion reactivity which ultimately affects durability in harsh environments.

36 MATERIALS SCIENCE↗

Soft x-ray detection for small satellites with a commercial CMOS sensor at room temperature

Recently CMOS (complementary metal-oxide-semiconductor) sensors have progressed to a point where they may offer improved performance in imaging x-ray detection compared to the CCDs often used in x-ray satellites. We demonstrate x-ray detection in the soft x-ray band (250-1700 eV) by a commercially available back-illuminated Sony IMX290LLR CMOS sensor using the Advanced Photon Source at the Argonne National Laboratory. Additionally, while operating the device at room temperature, we measure energy resolutions (FWHM) of 47 eV at 250 eV and and 77 eV 1700 eV which are comparable to the performance of the Chandra ACIS and the Suzaku XIS. Furthermore, we demonstrate that the IMX290LLR can withstand radiation up to 17.1 krad, making it suitable for use on spacecraft in low earth orbit.

47 OTHER INSTRUMENTATION↗

HRMT-60- RaDIATE Material Studies

HRMT-60 experiment was performed at the CERN-HiRadMat facility in October 2022 to understand thermal shock response of conventional materials and novel materials to support the design and operation of future multi-MW accelerator beam windows and secondary particle-production targets. This experiment, organized within the framework of the RaDIATE collaboration, builds on the previous HRMT-43 (BeGrid2) experiment, where a variety of materials in both non-irradiated and previously proton-irradiated conditions were tested. The primary goal was to understand the failure mechanisms, limits and flow behavior of the various material specimens, as well as compare and contrast the thermal shock response of previously irradiated materials to their non-irradiated counterparts. A total of 120 samples were tested at different beam conditions. This poster will present the preliminary results of several materials tested during this experiments.

Ammigan, K.↗

Effects of Six Sequential Charged Particle Beams on Behavioral and Cognitive Performance in B6D2F1 Female and Male Mice

The radiation environment astronauts are exposed to in deep space includes galactic cosmic radiation (GCR) with different proportions of all naturally occurring ions. To assist NASA with assessment of risk to the brain following exposure to a mixture of ions broadly representative of the GCR, we assessed the behavioral and cognitive performance of female and male C57BL/6J × DBA2/J F1 (B6D2F1) mice two months following rapidly delivered, sequential 6 beam irradiation with protons (1 GeV, LET = 0.24 keV, 50%), 4 He ions (250 MeV/n, LET = 1.6 keV/μm, 20%), 16 O ions (250 MeV/n, LET = 25 keV/μm 7.5%), 28 Si ions (263 MeV/n, LET = 78 keV/μm, 7.5%), 48Ti ions (1 GeV/n, LET = 107 keV/μm, 7.5%), and 56 Fe ions (1 GeV/n, LET = 151 keV/μm, 7.5%) at 0, 25, 50, or 200 cGy) at 4–6 months of age. When the activity over 3 days of open field habituation was analyzed in female mice, those irradiated with 50 cGy moved less and spent less time in the center than sham-irradiated mice. Sham-irradiated female mice and those irradiated with 25 cGy showed object recognition. However, female mice exposed to 50 or 200 cGy did not show object recognition. When fear memory was assessed in passive avoidance tests, sham-irradiated mice and mice irradiated with 25 cGy showed memory retention while mice exposed to 50 or 200 cGy did not. The effects of radiation passive avoidance memory retention were not sex-dependent. There was no effect of radiation on depressive-like behavior in the forced swim test. There was a trend toward an effect of radiation on BDNF levels in the cortex of males, but not for females, with higher levels in male mice irradiated with 50 cGy than sham-irradiated. Finally, sequential 6-ion irradiation impacted the composition of the gut microbiome in a sex-dependent fashion. Taxa were uncovered whose relative abundance in the gut was associated with the radiation dose received. Thus, exposure to sequential six-beam irradiation significantly affects behavioral and cognitive performance and the gut microbiome.

60 APPLIED LIFE SCIENCES↗

RaDIATE Collaboration for Material Studies

In the recent past, major accelerator facilities have been limited in beam power not by their accelerators, but by the beam intercepting device survivability. As next-generation accelerator target facilities (High Energy Physics, Spallation Sources, …) become increasingly more powerful and intense, high power target systems face key technical challenges. Beam-intercepting devices such as beam windows and secondary particle-production targets are continuously bombarded by high-energy high-intensity pulsed proton beams to produce secondary particles. Energy deposition from the primary beam induces near instantaneous heating (thermal shock) and microstructural changes (radiation damage) in the beam-intercepting materials. Both thermal shock and radiation damage ultimately degrade the performance and lifetime of targets and have been identified as the leading cross-cutting challenges of high-power target facilities. In order to operate reliable beam-intercepting devices in the framework of energy and intensity increase for next generation accelerators, the RaDIATE collaboration (Radiation Damage In Accelerator Target Environment) managed by Fermilab, brings together existing expertise in nuclear material and accelerator targets from 20 international institutions to execute a coordinated strategy for high power targetry R&D. This collaboration is generating new and useful materials data for application within the accelerator and the fission/fusion communities. I will give an overview of the RaDIATE R&D program and the achievement in the last few years on material studies in support of High Power Targetry development, including results obtained from irradiation test, development of novel materials and the prospective towards future irradiation campaign. A highlight will be given to the results in collaboration with our colleagues from J-PARC.

Pellemoine, Frederique↗

Upgraded fiber-optic sensor system for dynamic strain measurement in Spallation Neutron Source

We describe an upgraded fiber-optic sensor system and its performance in measuring the dynamic strains in a mercury target of the Spallation Neutron Source (SNS). Strains result from dynamic pressure waves in the stainless-steel mercury target induced by short (~700 ns), intense (up to 23.3 kJ), high-energy (~1 GeV) proton pulses. In the upgraded sensor system, the output of each sensor head is interrogated with a compact, all-fiber based Faraday Michelson interferometer, which generates interference signals with a steady phase shift. Strain waveforms are recovered from the phase-shifted interference signals using a high-speed digital signal processing procedure developed in our previous work. We demonstrate successful measurements of dynamic strain pulses, e.g., 400με over 190μs , on a recently installed SNS target using the upgraded sensor system. The measured strain waveforms are analyzed for more than 20 sensor locations and/or orientations, and provide information regarding the temporal structure of strain profiles and dependence of the strain magnitude on the proton powers of 200 – 1400 kW. The new interrogator also measures the radiation-induced-attenuation (RIA) in the optical fiber, enabling experimental investigations of RIA profiles induced by a 700-ns radiation pulse. The radiation effects on the strain measurement performance are discussed over a radiation dose range of up to 4×10 8 Gy and an RIA compensation method is proposed. The measurements allow insight into the response of this unique piece of equipment and can be used for validation of simulations.

47 OTHER INSTRUMENTATION↗

Why Does Atmospheric Radiative Heating Weaken Midlatitude Cyclones?

Abstract Recent work has indicated that atmospheric radiative heating reduces the kinetic energy of large‐scale eddies in the midlatitudes. However, a physical mechanism that connects radiation to the midlatitude eddy kinetic energy is still uncertain. Using a high‐resolution general circulation model we perform an experiment in which the radiative cooling profile at each model time step is overwritten with the climatological mean, computed from a control simulation. This approach separates the mean and transient effects of radiative heating on the extratropical circulation. We find that, when radiative heating is fixed, the globally‐averaged eddy kinetic energy is enhanced by ∼6%. We show that thermal radiation dampens temperature anomalies near the surface and tropopause in low‐pressure systems, destroying eddy available potential energy and eddy kinetic energy. We identify this as a possible mechanism by which atmospheric radiative heating weakens midlatitude cyclones.

Mischell, Eric↗

Comparison of spherical harmonics method and discrete ordinates method for radiative transfer in a turbulent jet flame

Here, in this study, we systematically compared the accuracy and computational cost of two popular solution methods for the radiative transfer equation (RTE): the spherical harmonics method (P N ) and the discrete ordinates method (DOM). We first investigated convergence characteristics of different orders of P N and DOM in a series of 1D homogeneous configurations with varying optical thicknesses. Both solvers perform better for optically thicker cases. The accuracy of P N methods increases with its order, , but the gain in accuracy reduces with the increase in , i.e., improvement of P 7 over P 5 is less than that of P 3 over P 1 . This decreasing trend becomes more prominent as the optical thickness decreases. On the other hand, DOM’s accuracy increases almost linearly with the increase in the number of ordinates (or polar angles in this study) in all cases. While comparing the directional profile of radiative intensity, both solvers perform better when the radiative intensity is more isotropic. These solvers were then connected with a full spectrum k-distribution (FSK) spectral model and used to perform radiation-coupled simulations of a turbulent jet flame in an axi-symmetric cylindrical domain. Results obtained from P 1 to P 7 approximations for P N , and 2 x 4, 4 x 4, 4 x 8, 8 x 8 finite angles for DOM are compared with that from an optically thin model, and a reference solution from line-by-line (LBL) photon Monte Carlo (PMC) method. The choice of radiation solver shows a noticeable impact on the temperature distribution of the flame. The P N solvers lead to slightly higher radiant fractions and the DOM solvers lead to slightly lower radiant fractions than the PMC benchmark solution. Finally, the computational costs of each of these solvers are also reported and an intermittent evaluation / time blending scheme to improve the computational efficiency of radiation solvers in radiation-coupled simulations are also demonstrated.

42 ENGINEERING↗

Minimizing hydrogen vacancies to enable highly efficient hybrid perovskites

Defect-induced non-radiative losses are currently limiting the performance of hybrid perovskite devices. Experimental reports have indicated the existence of point defects that act as detrimental non-radiative recombination centres under iodine-poor synthesis conditions. However, the microscopic nature of these defects is still unknown. Here we demonstrate that hydrogen vacancies can be present in high densities under iodine-poor conditions in the prototypical hybrid perovskite MAPbI 3 (MA = CH 3 NH 3 ). They act as very efficient non-radiative recombination centres with an exceptionally high carrier capture coefficient of 10 –4 cm 3 s –1 . By contrast, the hydrogen vacancies in FAPbI 3 [FA = CH(NH 2 ) 2 ] are much more difficult to form and have a capture coefficient that is three orders of magnitude lower. Our study unveils the critical but overlooked role of hydrogenvacancies in hybrid perovskites and rationalizes why FA is essential for realizing high efficiency in hybrid perovskite solar cells. Furthermore, minimizing the incorporation of hydrogen vacancies is key to enabling the best performance of hybrid perovskites.

14 SOLAR ENERGY↗