Capabilities of operational infrared sounding systems from satellite altitude

Initial attempts at using satellite radiances resulted in the production of temperature profiles similar to those produced by radiosondes. While increases in accuracy were made and additional increases are expected to result from increased instrument capabilities, it was recognized that the production of level temperatures is not consistent with the average temperature that is represented by the radiances.

Mcmillin, L.↗

A Microwave Pressure Sounder

An instrument to measure atmospheric pressure at the earth's surface from an orbiting satellite would be a valuable addition to the expanding inventory of remote sensors. The subject of this report is such an instrument - the Microwave Pressure Sounder (MPS). It is shown that global-ocean coverage is attainable with sufficient accuracy, resolution and observational frequency for meteorological, oceanographic and climate research applications. Surface pressure can be deduced from a measurement of the absorption by an atmospheric column at a frequency in the wing of the oxygen band centered on 60 GHz. An active multifrequency instrument is needed to make this measurement with sufficient accuracy. The selection of optimum operating frequencies is based upon accepted models of surface reflection, oxygen, water vapor and cloud absorption. Numerical simulation using a range of real atmospheres defined by radiosonde observations were used to validate the frequency selection procedure. Analyses are presented of alternative system configurations that define the balance between accuracy and achievable resolution.

Flower, D. A.↗

Measurements of earth-space attenuation at 230 GHz

Measurements of attenuation at 230 GHz through the total atmosphere due to the presence of oxygen and water vapor molecules, clouds, and rain are presented. The measurements were carried out using a specially designed superheterodyne receiver mounted on a sun tracker. Simultaneous measurements were also carried out at 13 GHz. For a measuring site close to sea level at Holmdel, NJ, the 'clear-sky' zenith attenuation was found as a function of the measured ground water vapor density. When the ground temperature was below about 7 C, most cloud and overcast gave less than 0.5-dB attenuation, whereas with a ground temperature greater than 13 C, cloud attenuation was 8-10 times greater. Calculations of zenith attenuation in the 230-GHz atmospheric window were also made using the Gross analytic line shape, Schulze-Tolbert empirical line shape, and an empirically modified Gross line shape. These calculations were based on determinations of water vapor density and temperature made at the measurement site, and on radiosonde measurements made at a distance of 80 km away.

Wrixon, G. T.↗

The multiple nesting of mesoscale, submesoscale, and nonhydrostatic microscale numerical models for a case of mesocyclogenesis and severe storm development

A fundamental approach involving the integration of two different numerical models over several different spatial mesh lengths is considered. Model I is a hydrostatic, incompressible, and adiabatic primitive (Newtonian) equation set with no boundary layer forcing, i.e., surface heat or moisture flux or external frictional stresses. Typically this model is initialized from conventional radiosonde data and run for a 12-15 hour forecast period over a 40 km horizontal mesh. If phase I of the tornado developmental processes develops, the data is 'frozen' in space and time, interpolated to a 20 km mesh, and integrated for a shorter time period (3 hours) with a shorter time step. Model II is a nonhydrostatic compressible 18-level complement of model I. If model II indicates the development of the intensification of phase V dynamical processes, the data is frozen and interpolated to finer mesh lengths until the tornadic circulation system is approximated

Kaplan, M. L.↗

DSN water vapor radiometer: Tropospheric range delay calibration

A discussion is presented of the Deep Space Network water vapor radiometer by means of simultaneous antenna temperature and radiosonde measurements at Edwards Air Force Base. The calibration of radiometer gain and hot load radiometric noise temperature is also described. Calibration equations are given. It is found that with a selected data set, the RMS error is less than 1 cm over a total delay range of 9 to 38 cm. Limitations on the use of the water vapor radiometer are also given.

Slobin, S. D.↗

A summary of Nimbus-6 temperature retrieval accuracy statistics for DST-5 and DST-6

Statistics compiled from Nimbus-6 temperature retrievals processed during the 18 August-4 September 1975 DST-5, and the 1 February-4 March 1976 DST-6 are addressed. All statistics were compiled from samples of colocated satellite sounding and radiosonde measurements. The colocation window is 222 km in space and 6 hours in time.

Hayden, C. M.↗

Airborne pressure and temperature measurements during the 1977 intertropical convergence zone experiment

During the 1977 ITCZ (Intertropical Convergence Zone) experiment in Panama two aircraft and numerous balloon-borne radiosonde instruments were equipped to measure pressure and temperature. The experiment was a coordinated effort to evaluate the meteorological conditions that prevailed from July 17 through 31, 1977. A critical analysis of the data collected on one of the aircraft (the Lear jet) operating at altitudes to 13,000 m for about 2 hr each day during most days of the experiment is presented. The discussion includes a comparison of the vertical profiles of potential temperature obtained from the Learjet with those obtained from balloons launched at Ft. Sherman. Time histories of pressure, temperature, and potential temperature, as observed from the Learjet are also presented.

Munoz, R. M.↗

Concentrations of condensation nuclei in the vicinity of jetstream maxima

Ozone and condensation nuclei were measured on March 29, 1977 (and March 30, GMT) from a Sabreliner in a frontal zone south of Denver, Colo. The ozone served as a tracer for stratospheric air and the condensation nuclei as a tracer for tropospheric air. Both the Langer condensation nucleus counter and the Rich-100 counter can be used to measure condensation nucleus concentrations in the vicinity of the tropopause. However, the former counter is more sensitive to low concentrations. The nuclei measured were found to be almost entirely larger than 0.005 micron in radius, consisting of thousands of molecules. The mesostructure of the ozone and condensation nucleus concentrations agreed well with a double structure of the frontal zone that became apparent from a detailed analysis of radiosonde data.

Cadle, R. D.↗

Effect of subjectively enhancing the initial vorticity field in a short-range numerical forecast

The paper tests a simple method to incorporate subsynoptic-scale information into the initial conditions of a forecast model. The amplitude, orientation and vertical structure of the vorticity field associated with the subsynoptic-scale disturbance are estimated subjectively; this is done using a combination of climatological and physical models together with all available data. The initial values of geopotential are then obtained in the vicinity of the subsynoptic-scale disturbance, as over the rest of the domain, through the balance equation. Two sets of initial conditions are tested in 12-hr forecasts using a six-layer version of a primitive equation forecast model (Anthes and Warner, 1978). The analysis schemes consisted of (1) a careful subjective analysis of radiosonde data with a high-resolution objective interpolation, and (2) the same preceding analysis but including data derived from the enhanced vorticity fields in the vicinity of the subsynoptic-scale disturbance. The results are discussed in some detail.

Fried, G. D.↗

Refraction of microwave signals by water vapor

Tropospheric water vapor causes a refractive path length effect which is typically 5-10% of the 'dry' tropospheric effect and as large as several meters at elevation angles below 5 deg. The vertical water vapor profile is quite variable, and measurements of intensive atmospheric parameters such as temperature and humidity limited to the surface do not adequately predict the refractive effect. It is suggested that a water vapor refraction model that is a function of the amount of precipitable water alone can be successful at low elevation angles. From an extensive study of numerical ray tracings through radiosonde balloon data, such a model has been constructed. The model predicts the effect at all latitudes and elevation angles between 2 and 10 deg to an accuracy of better than 4% (11 cm at 3 deg elevation angle).

Goldfinger, A. D.↗

The 1979 Southeastern Virginia Urban Plume Study. Volume 1: Description of experiments and selected aircraft data

The Southeastern Virginia Urban Plume Study (SEV-UPS) utilizes remote sensors and satellite platforms to monitor the Earth's environment and resources. SEV-UPS focuses on the application of specific remote sensors to the monitoring and study of specific air quality problems. The 1979 SEV-UPS field program was conducted with specific objectives: (1) to provide correlative data to evaluate the Laser Absorption spectrometer ozone remote sensors; (2) to demonstrate the utility of the sensor for the study of urban ozone problems; (3) to provide additional insights into air quality phenomena occuring in Southeastern Virginia; and (4) to compare measurement results of various in situ measurement platforms. The field program included monitoring from 12 surface stations, 4 aircraft, 2 tethered balloons, 2 radiosonde release sites, and numerous surface meteorological observation sites. The aircraft monitored 03, NO, NOX, Bscat, temperature, and dewpoint temperature.

Gregory, G. L.↗

Low level moisture from VAS

Previous research and current opinion are too pessimistic concerning the capability of defining moisture fields from satellite measurements. The TIROS-N sounder is a close analogue to what will fly on GEOS-D and can be used to investigate the probable capability of VAS. Basically, there are three frequencies applied to sensing moisture in the troposphere. The ability of these three measurements to define the moisture pattern is assessed. It is certainly true that one cannot achieve the detail available with a radiosonde hygristor. Sharp discontinuities cannot be sensed by a passive sounder, especially since the measurement tends to "saturate" with the first moisture layer encountered. However, the satellite measurements demonstrate a high degree of skill in defining the horizontal gradient. Moisture "tongues" and "dry lines" are readily delineated with some, perhaps two layers, of vertical definition. These attributes allow both the calculation of important advective quantities as well as (in concert with the temperature sounding) a gross definition of the vertical stability. The skill is demonstrably commensurate with subsynoptic forecast models and perhaps even to regional scale models.

Hayden, C. M.↗

The President's Day cyclone 17-19 February 1979: An analysis of jet streak interactions prior to cyclogenesis

The President's Day cyclone, produced record breaking snowfall along the East Coast of the United States in February 1979. Conventional radiosonde data, SMS GOES infrared imagery and LFM 2 model diagnostics were used to analyze the interaction of upper and lower tropospheric jet streaks prior to cyclogenesis. The analysis reveals that a series of complex scale interactive processes is responsible for the development of the intense cyclone. The evolution of the subsynoptic scale mass and momentum fields prior to and during the period of rapid development of the President's Day cyclone utilizing conventional data and SMS GOES imagery is documented. The interaction between upper and lower tropospheric jet streaks which occurred prior to the onset of cyclogenesis is discussed as well as the possible effects of terrain modified airflow within the precyclogenesis environment. Possible deficiencies in the LFM-2 initial wind fields that could have been responsible, in part, for the poor numerical forecast are examined.

Uccellini, L. W.↗

Remote sensing of precipitable water over the oceans from Nimbus-7 microwave measurements

Global maps of precipitable water over derived from scanning multichannel microwave radiometer (SMMR) data reveal salient features associated with ocean currents and the large scale general circulation in the atmosphere. Nimbus-7 SMMR brightness temperature measurements in the 21 and 18 GHz channels are used to sense the precipitable water in the atmospheric over oceans. The difference in the brightness temperature (T sub 21 -T sub 18), both in the horizontal and vertical polarization, is found to be essentially a function of the precipitable water in the atmosphere. An equation, based on the physical consideration of the radiative transfer in the microwave region, is developed to relate the precipitable water to (T sub 21 - T sub 18). It shows that the signal (T sub 21- T sub 18) does not suffer severely from the noise introduced by variations in the sea surface temperature, surface winds, and liquid water content in non rain clouds. The rms deviation between the estimated precipitable water from SMMR data and that given by the closely coincident ship radiosondes is about 0.25 g/ sq cm

Prabhakara, C.↗

Estimation of the propagation delay through the troposphere from microwave radiometer data

Microwave propagation delay through the troposphere is studied as a means of estimating the adverse effect of atmospheric water vapor on the accuracy of measurements made with very long baseline interferometry. Vertical profiles of temperature and water vapor density were obtained from a total of 240 radiosonde launches taken simultaneously at three New England locations in 1974; all studies were made at the 19 and 22.2 GHz frequency operating range of the radiometers. The wet path length in the zenith direction could be estimated from the surface water vapor density to an accuracy of 5 cm for the summer data and 2 cm for winter data, and with the brightness temperatures, it could be estimated to an accuracy of 0.3 cm. Two dual-frequency radiometers were also used to determine the accuracy of prediction of the path length from real radiometry data. The rms error for the estimation of wet path length from surface meteorological parameters was 3.2 cm, and for the radiometer brightness temperatures the rms error was 1.5 cm.

Moran, J. M.↗

Meteorological Analysis of Icing Conditions Encountered in Low-Altitude Stratiform Clouds

Liquid-water content, droplet size, and temperature data measured during 22 flights in predominatly stratiform clouds through the 1948-49 and the 1949-50 winters are presented. Several icing encounters were of greater severity than those previously measured over the same geographical area, but were within the limits of similar measurements obtained over different terrain within the United States. An analysis of meteorological conditions existing during the 74 flights conducted for four winters indicated an inverse relation of liquid-water concentration to maximum horizontal extent of icing clouds. Data on the vertical extent of supercooled clouds are also presented. Icing conditions were most likely to occur in the southwest and northwest quadrants of a cyclone area, and least likely to occur in the southeast and northeast quadrants where convergent air flow and lifting over the associated warm frontal surface usually cause precipitation. Additional data indicated that, icing conditions were usually encountered in nonprecipitating clouds existing at subfreezing temperatures and were unlikely over areas where most weather observing stations reported the existence of precipitation. Measurements of liquid-water content obtained during 12 flights near the time and location of radiosonde observations were compared with theoretical values. The average liquid-water content of a cloud layer, as measured by the multicylinder technique, seldom exceeded two-thirds of that which could be released by adiabatic lifting. Local areas near the cloud tops equaled or occasionally exceeded the calculated maximum quantity of liquid water.

Kline, D. B.↗

Assessment of the first radiances received from the VSSR Atmospheric Sounder (VAS) instrument

The first orderly, calibrated radiances from the VAS-D instrument on the GOES-4 satellite are examined for: image quality, radiometric precision, radiation transfer verification at clear air radiosonde sites, regression retrieval accuracy, and mesoscale analysis features. Postlaunch problems involving calibration and data processing irregularities of scientific or operational significance are included. The radiances provide good visual and relative radiometric data for empirically conditioned retrievals of mesoscale temperature and moisture fields in clear air.

Chesters, D.↗