Search NASA⌕ Search

SEARCH · Search NASA

Results for “Real time control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Computer-controlled environmental test systems - Criteria for selection, installation, and maintenance.

Applications for presently marketed, new computer-controlled environmental test systems are suggested. It is shown that capital costs of these systems follow an exponential cost function curve that levels out as additional applications are implemented. Some test laboratory organization changes are recommended in terms of new personnel requirements, and facility modification are considered in support of a computer-controlled test system. Software for computer-controlled test systems are discussed, and control loop speed constraints are defined for real-time control functions. Suitable input and output devices and memory storage device tradeoffs are also considered.

Chapman, C. P.↗

Cellular Decomposition Based Hybrid-Hierarchical Control Systems with Applications to Flight Management Systems

The work in this research project has been focused on the construction of a hierarchical hybrid control theory which is applicable to flight management systems. The motivation and underlying philosophical position for this work has been that the scale, inherent complexity and the large number of agents (aircraft) involved in an air traffic system imply that a hierarchical modelling and control methodology is required for its management and real time control. In the current work the complex discrete or continuous state space of a system with a small number of agents is aggregated in such a way that discrete (finite state machine or supervisory automaton) controlled dynamics are abstracted from the system's behaviour. High level control may then be either directly applied at this abstracted level, or, if this is in itself of significant complexity, further layers of abstractions may be created to produce a system with an acceptable degree of complexity at each level. By the nature of this construction, high level commands are necessarily realizable at lower levels in the system.

Caines, P. E.↗

Encryption for Remote Control via Internet or Intranet

A data-communication protocol has been devised to enable secure, reliable remote control of processes and equipment via a collision-based network, while using minimal bandwidth and computation. The network could be the Internet or an intranet. Control is made secure by use of both a password and a dynamic key, which is sent transparently to a remote user by the controlled computer (that is, the computer, located at the site of the equipment or process to be controlled, that exerts direct control over the process). The protocol functions in the presence of network latency, overcomes errors caused by missed dynamic keys, and defeats attempts by unauthorized remote users to gain control. The protocol is not suitable for real-time control, but is well suited for applications in which control latencies up to about 0.5 second are acceptable. The encryption scheme involves the use of both a dynamic and a private key, without any additional overhead that would degrade performance. The dynamic key is embedded in the equipment- or process-monitor data packets sent out by the controlled computer: in other words, the dynamic key is a subset of the data in each such data packet. The controlled computer maintains a history of the last 3 to 5 data packets for use in decrypting incoming control commands. In addition, the controlled computer records a private key (password) that is given to the remote computer. The encrypted incoming command is permuted by both the dynamic and private key. A person who records the command data in a given packet for hostile purposes cannot use that packet after the public key expires (typically within 3 seconds). Even a person in possession of an unauthorized copy of the command/remote-display software cannot use that software in the absence of the password. The use of a dynamic key embedded in the outgoing data makes the central-processing unit overhead very small. The use of a National Instruments DataSocket(TradeMark) (or equivalent) protocol or the User Datagram Protocol makes it possible to obtain reasonably short response times: Typical response times in event-driven control, using packets sized .300 bytes, are <0.2 second for commands issued from locations anywhere on Earth. The protocol requires that control commands represent absolute values of controlled parameters (e.g., a specified temperature), as distinguished from changes in values of controlled parameters (e.g., a specified increment of temperature). Each command is issued three or more times to ensure delivery in crowded networks. The use of absolute-value commands prevents additional (redundant) commands from causing trouble. Because a remote controlling computer receives "talkback" in the form of data packets from the controlled computer, typically within a time interval < or =1 s, the controlling computer can re-issue a command if network failure has occurred. The controlled computer, the process or equipment that it controls, and any human operator(s) at the site of the controlled equipment or process should be equipped with safety measures to prevent damage to equipment or injury to humans. These features could be a combination of software, external hardware, and intervention by the human operator(s). The protocol is not fail-safe, but by adopting these safety measures as part of the protocol, one makes the protocol a robust means of controlling remote processes and equipment by use of typical office computers via intranets and/or the Internet.

Lineberger, Lewis↗

Fast DR: Controlling Small Loads over the Internet

Current state-of-the-art demand response systems are expensive due to extreme reliability constraints in telemetry, control, and metering. The typical cost of enabling a site for regulation services is between $50k and $80k. These costs are orders of magnitude too high for small loads to participate in high-value grid services. Traditional demand response (DR) schedules events in advance and provides basic on/off control. We developed fast DR measurement and communication technologies, which are scalable cost-effective demand response systems with sufficient reliability for real-time control and monitoring of loads over the internet, and we demonstrated an example system for under $100. We installed FastDR systems for lighting, motor, and thermostat control along with power metering at a total of 10 sites, including 6 commercial buildings and 4 residential buildings. This demonstration addressed the following important methodological questions: 1) Can we reliably control loads simultaneously and with low latency across multiple sites within a specified response time; 2) How reliable is using the internet or 4G cellular network as the mode of control and metering; and 3) Can existing Smart Meters provide data for real-time telemetry services. Testing shows fast DR is capable of control to response in 4 seconds and loads complete transition in seconds to less than one minute depending on load type. We demonstrated 4s regulation services and synchronized load control, and we successfully met specifications for ancillary services across the US. Telemetry via the 4G cellular network demonstrated 94.5% success rate, and residential Internet demonstrated a 98% success rate.

Kiliccote, Sila↗

Control Strategies for HCCI Mixed-Mode Combustion

Delphi Automotive Systems and ORNL established this CRADA to expand the operational range of Homogenous Charge Compression Ignition (HCCI) mixed-mode combustion for gasoline en-gines. ORNL has extensive experience in the analysis, interpretation, and control of dynamic engine phenomena, and Delphi has extensive knowledge and experience in powertrain compo-nents and subsystems. The partnership of these knowledge bases was important to address criti-cal barriers associated with the realistic implementation of HCCI and enabling clean, efficient operation for the next generation of transportation engines. The foundation of this CRADA was established through the analysis of spark-assisted HCCI data from a single-cylinder research engine. This data was used to (1) establish a conceptual kinetic model to better understand and predict the development of combustion instabilities, (2) develop a low-order model framework suitable for real-time controls, and (3) provide guidance in the initial definition of engine valve strategies for achieving HCCI operation. The next phase focused on the development of a new combustion metric for real-time characterization of the combustion process. Rapid feedback on the state of the combustion process is critical to high-speed decision making for predictive control. Simultaneous to the modeling/analysis studies, Delphi was focused on the development of engine hardware and the engine management system. This included custom Delphi hardware and control systems allowing for flexible control of the valvetrain sys-tem to enable HCCI operation. The final phase of this CRADA included the demonstration of conventional and spark assisted HCCI on the multi-cylinder engine as well as the characterization of combustion instabilities, which govern the operational boundaries of this mode of combustion. ORNL and Delphi maintained strong collaboration throughout this project. Meetings were held on a bi-weekly basis with additional reports, presentation, and meetings as necessary to maintain progress. Delphi provided substantial support through modeling, hardware, data exchange, and technical consultation. This CRADA was also successful at establishing important next steps to further expanding the use of an HCCI engine for improved fuel efficiency and emissions. These topics will be address in a follow-on CRADA. The objectives are: (1) Improve fundamental understanding of the development of combustion instabilities with HCCI operation through modeling and experiments; (2) Develop low-order model and feedback combustion metrics which are well suited to real-time predictive controls; and (3) Construct multi-cylinder engine system with advanced Delphi technologies and charac-terize HCCI behavior to better understand limitations and opportunities for expanded high-efficiency operation.

02 PETROLEUM↗

Development and testing of controller performance evaluation methodology for multi-input/multi-output digital control systems

Described here is the development and implementation of on-line, near real time controller performance evaluation (CPE) methods capability. Briefly discussed are the structure of data flow, the signal processing methods used to process the data, and the software developed to generate the transfer functions. This methodology is generic in nature and can be used in any type of multi-input/multi-output (MIMO) digital controller application, including digital flight control systems, digitally controlled spacecraft structures, and actively controlled wind tunnel models. Results of applying the CPE methodology to evaluate (in near real time) MIMO digital flutter suppression systems being tested on the Rockwell Active Flexible Wing (AFW) wind tunnel model are presented to demonstrate the CPE capability.

Pototzky, Anthony↗

Design, Optimization, and Control of Floating Offshore Wind Farms for Optimal Energy Production (Final report)

The uncertainty and irregularity of ocean waves and the ocean environment is a major factor in the development of commercial scale floating wind turbines as the operation of floating structures in such an environment can lead to irregular and unpredictable loading, fatigue, and ultimately a reduction in the operational life of the turbine system which affects energy production over the lifetime of the turbine. Control solutions that can limit float motions and mitigate stressful events on the structure become essential for extending lifetime and limiting the operational uncertainty of a floating wind turbine. Digital twins are computational replicas of physical systems that operate in parallel with the operation of the physical system. Given advanced knowledge of a systems input, digital twins have the ability to predict the behavior of a system in advance, which can be valuable in the control of that system. In this project, we developed and assessed potential digital twin models developed in house and openly available (OpenFast) for use in the real time control of the six degree of freedom response motions of a floating wind turbine in ocean waves. Coupling these models with near-field real time irregular sea surface (wve) measurement/sensings and prediction models, we used the digital twin to predict how the floating turbine will respond to the incoming waves. Applying this information to a motion control system of the float, one can limit and control float motions to prevent undesirable loading events/large angular motions, thus increasing system life and ultimately contributing to optimizing energy production. Due to the computational intensity of operating a digital twin in real time, we investigated the use of artificial intelligence techniques to speed-up the processes of the digital twin, as well as the wave reconstruction/prediction models. Model tank testing at the University of Rhode Island and University of Maine both validated and demonstrated the developed techniques on simple float geometries and a scale model of the NREL 15 MW reference turbine.

17 WIND ENERGY↗

Real-time reconstruction and control of pedestal-top electron density using RMP and gas puff at KSTAR

We report the experimental results of controlling the pedestal-top electron density by applying resonant magnetic perturbation (RMP) with in-vessel control coils and the main gas puff in the 2024-2025 KSTAR experimental campaign. The density is reconstructed using a parameterized $ψ_N$ grid and five channels of line-averaged density measured by the two-colored interferometer (TCI). The reconstruction procedure is accelerated by deploying a multi-layer perceptron to run in approximately 120 µ s and is sufficiently fast for real-time control. A proportional-integral controller was adopted, with the controller gains estimated from the system identification procedure. The experimental results demonstrate that the developed controller can follow a dynamic target while exclusively using both actuators. The absolute percentage errors between the electron density at $ψ_N$ = 0.89 and the target were approximately 1.5% median and a 2.5% average, respectively. The developed controller can even lower the density by using the pump-out mechanism under RMP, and it can follow a more dynamic range of density targets than a single actuator controller. The developed controller will enable experimental scenario exploration within a shot by dynamically setting the density target or maintaining a constant electron density within a discharge.

EFIT↗

Applications of interest : a relational database approach to managing control system software applications.

Large accelerator facilities such as the Advanced Photon Source (APS) typically are operated by a diverse set of integrated control systems, such as front-end controllers, PLCs, and FPGAs. This type of control system structure encompasses numerous engineering documents, distributed real-time control system databases, source code, user displays, and other components. The complexity of the control system is further increased as the life cycle of a control system is never ending, change is constant. And the accelerator itself generates new operational problems on a regular basis. This overall controls environment begs the question of how best to provide a means for control system engineers to easily and quickly troubleshoot unique functions of the control system, find relevant information, and understand the impact of changes to one part of the control system on other applications. The answer to this question lies in being able to associate pertinent drawings, manuals, source code, hardware, and expert developers in an efficient and logical manner. Applications of Interest is a relational database software tool created for the purpose of providing alternative views of the supporting information behind each distinct control system application at the APS.

43 PARTICLE ACCELERATORS↗

Using EPICS enabled industrial hardware for upgrading control systems

Los Alamos National Laboratory has been working with National Instruments (NI) and Cosy lab to implement EPICS Input Output Controller (IOC) software that runs directly on NI CompactRIO Real Time Controller (RTC) and communicates with NI LabVIEW through a shared memory interface. In this presentation, we will discuss our current progress in upgrading the control system at the Los Alamos Neutron Science Centre (LANSCE) and what we have learned about integrating CompactRIO into large experimental physics facilities. We will also discuss the implications of using Channel Access Server for LabVIEW which will enable more commercial hardware platforms to be used in upgrading existing facilities or in commissioning new ones.

43 PARTICLE ACCELERATORS↗

Automated Subsystem Control for Life Support System (ASCLSS)

The Automated Subsystem Control for Life Support Systems (ASCLSS) program has successfully developed and demonstrated a generic approach to the automation and control of space station subsystems. The automation system features a hierarchical and distributed real-time control architecture which places maximum controls authority at the lowest or process control level which enhances system autonomy. The ASCLSS demonstration system pioneered many automation and control concepts currently being considered in the space station data management system (DMS). Heavy emphasis is placed on controls hardware and software commonality implemented in accepted standards. The approach demonstrates successfully the application of real-time process and accountability with the subsystem or process developer. The ASCLSS system completely automates a space station subsystem (air revitalization group of the ASCLSS) which moves the crew/operator into a role of supervisory control authority. The ASCLSS program developed over 50 lessons learned which will aide future space station developers in the area of automation and controls..

Block, Roger F.↗

Design of an Event-Driven Random-Access-Windowing CCD-Based Camera

Commercially available cameras are not design for the combination of single frame and high-speed streaming digital video with real-time control of size and location of multiple regions-of-interest (ROI). A new control paradigm is defined to eliminate the tight coupling between the camera logic and the host controller. This functionality is achieved by defining the indivisible pixel read out operation on a per ROI basis with in-camera time keeping capability. This methodology provides a Random Access, Real-Time, Event-driven (RARE) camera for adaptive camera control and is will suited for target tracking applications requiring autonomous control of multiple ROI's. This methodology additionally provides for reduced ROI read out time and higher frame rates compared to the original architecture by avoiding external control intervention during the ROI read out process.

event driven↗

Enhancing the Flexibility of Generation of Run-Of-the-River Hydro Power Plants

Run-of-the-River Hydro Power Plants (ROR HPPs) output can be characterized as fixed and predictable output with low cost of both installation and operation. ROR HPP generation is proportional to the water flow and cannot be adjusted to provide inertia to the grid, which is critical to power systems stability. Hence ROR HPP can only participate in low profit energy markets and not in the high profit ancillary service market. With the advances in energy storage, they can help build a synthetic energy reservoir. The combined operation of ROR HPPs and energy storage are capable of both ramping and variable power output, allowing participation in the ancillary service markets. However, energy storage technologies such as supercapacitors and flywheels, which are power dense can quickly charge/discharge within a short duration. Energy dense storage technologies such as batteries can provide long duration energy injection while the maximum ramping rate is much lower than power dense energy storage. In order to provide long duration fast ramping capability, Hybrid Energy Storage Systems (HESSs) including both power and energy dense energy storage are proposed to be integrated to enable the flexible operation of ROR HPP. Power dense energy storage with quick burst of energy can assist in regulation, whereas energy dense storage can provide energy balance over larger time. In this paper, the properties of different types of energy storage including the ramping rate, affordable energy storage capacity, thermal management, etc. are analyzed. The size of each type of energy storage is determined to ensure optimal combination of HESS and ROR HPP. A generic Front End Controller (FEC) is developed and customized for ROR HPP to provide real time control and cohesive operation of multiple units. FEC serves as the interface between utility management systems and ROR HPPs to ensure their integration with the centralized controls. Using the Automatic Generation Control (AGC) signal received from grid operator, FEC optimizes the ROR HPP turbine and HESS so that the aggregated generation can satisfy the market needs. Based on the study, system operator can acquire extra inertia support for system stability, and the ROR HPP operators can enhance their revenues by participating in wider market avenues.

13 HYDRO ENERGY↗

A COMPACTRIO-BASED BEAM LOSS MONITOR FOR THE SNS RF TEST CAVE

An RF Test Cave has been built at the Spallation Neutron Source (SNS) to be able to test RF cavities without interfering the SNS accelerator operations. In addition to using thick concrete wall to minimize radiation exposure, a Beam Loss Monitor (BLM) must abort the operation within 100 usec when the integrated radiation within the cave exceeds a threshold. We choose the CompactRIO platform to implement the BLM based on its performance, cost-effectiveness, and rapid development. Each in/output module is connected through an FPGA to provide point-by-point processing. Every 10 usec the data is acquired analyzed and compared to the threshold. Data from the FPGA is transferred using DMA to the real-time controller, which communicates to a gateway PC to talk to the SNS control system. The system includes diagnostics to test the hardware and integrates the losses in real-time. In this paper we describe our design, implementation, and results

43 PARTICLE ACCELERATORS↗

Ground vehicle control at NIST: From teleoperation to autonomy

NIST is applying their Real-time Control System (RCS) methodology for control of ground vehicles for both the U.S. Army Researh Lab, as part of the DOD's Unmanned Ground Vehicles program, and for the Department of Transportation's Intelligent Vehicle/Highway Systems (IVHS) program. The actuated vehicle, a military HMMWV, has motors for steering, brake, throttle, etc. and sensors for the dashboard gauges. For military operations, the vehicle has two modes of operation: a teleoperation mode--where an operator remotely controls the vehicle over an RF communications network; and a semi-autonomous mode called retro-traverse--where the control system uses an inertial navigation system to steer the vehicle along a prerecorded path. For the IVHS work, intelligent vision processing elements replace the human teleoperator to achieve autonomous, visually guided road following.

Murphy, Karl N.↗

Optimization of 3D controlled ELM-free state with recovered global confinement for KSTAR with n = 1 resonant magnetic field perturbation

Mitigation of deleterious heat flux from edge-localized modes (ELMs) on fusion reactors is often attempted with 3D perturbations of the confining magnetic fields. However, the established technique of resonant magnetic perturbations (RMPs) also degrades plasma performance, complicating implementation on future fusion reactors. Here, we introduce an adaptive real-time control scheme on the KSTAR tokamak as a viable approach to achieve an ELM-free state and simultaneously recover high-confinement (βN ~ 1.91, β p ~ 1.53, and H 98 ~ 0.9), demonstrating successful handling of a volatile complex system through adaptive measures. We show that, by exploiting a salient hysteresis process to adaptively minimize the RMP strength, stable ELM suppression can be achieved while actively encouraging confinement recovery. This is made possible by a self-organized transport response in the plasma edge which reinforces the confinement improvement through a widening of the ion temperature pedestal and promotes control stability, in contrast to the deteriorating effect on performance observed in standard RMP experiments. These results establish the real-time approach as an up-and-coming solution toward an optimized ELM-free state, which is an important step for the operation of ITER and reactor-grade tokamak plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗