Search NASA⌕ Search

SEARCH · Search NASA

Results for “Recommender system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Guide for Oxygen Component Qualification Tests

Although oxygen is a chemically stable element, it is not shock sensitive, will not decompose, and is not flammable. Oxygen use therefore carries a risk that should never be overlooked, because oxygen is a strong oxidizer that vigorously supports combustion. Safety is of primary concern in oxygen service. To promote safety in oxygen systems, the flammability of materials used in them should be analyzed. At the NASA White Sands Test Facility (WSTF), we have performed configurational tests of components specifically engineered for oxygen service. These tests follow a detailed WSTF oxygen hazards analysis. The stated objective of the tests was to provide performance test data for customer use as part of a qualification plan for a particular component in a particular configuration, and under worst-case conditions. In this document - the 'Guide for Oxygen Component Qualification Tests' - we outline recommended test systems, and cleaning, handling, and test procedures that address worst-case conditions. It should be noted that test results apply specifically to: manual valves, remotely operated valves, check valves, relief valves, filters, regulators, flexible hoses, and intensifiers. Component systems are not covered.

Bamford, Larry J.↗

TH-CD-BRA-08: Novel Iron-Based Radiation Reporting Systems as 4D Dosimeters for MR-Guided Radiation Therapy

Purpose: To compare novel radiation reporting systems utilizing ferric ion (Fe{sup 3+}) reduction versus ferrous ion (Fe{sup 2+}) oxidation in gelatin matrixes for 3D and 4D (3D+time) MR-guided radiation therapy dosimetry. Methods: Dosimeters were irradiated using an integrated 1.5T MRI and 7MV linear accelerator (MR-Linac). Dosimeters were read-out with both a spectrophotometer and the MRI component of the MR-Linac immediately after irradiation. Changes in optical density (OD) were measured using a spectrophotometer; changes in MR signal intensity due to the paramagnetic differences in the iron ions were measured using the MR-Linac in real-time during irradiation (balanced-FFE sequences) and immediately after irradiation (T{sub 1}-weighted and inversion recovery sequences). Results: Irradiation of Fe{sup 3+} reduction dosimeters resulted in a stable red color with an absorbance peak at 512 nm. The change in OD relative to dose exhibited a linear response up to 100 Gy (R{sup 2}=1.00). T{sub 1}-weighted-MR signal intensity (SI) changed minimally after irradiation with increases of 8.0% for 17 Gy and 9.7% after escalation to 35 Gy compared to the un-irradiated region. Irradiation of Fe{sup 2+} oxidation dosimeters resulted in a stable purple color with absorbance peaks at 440 and 585 nm. The changes in OD, T{sub 1}-weighted-MR SI, and R{sub 1} relative to dose exhibited a linear response up to at least 8 Gy (R{sup 2}=1.00, 0.98, and 0.99) with OD saturation above 40 Gy. The T{sub 1}-weighted-MR SI increased 50.3% for 17 Gy compared to the un-irradiated region. The change in SI was observed in both 2D+time and 4D (3D+time) acquisitions post-irradiation and in real-time during irradiation with a linear increase with respect to dose (R{sup 2}>0.93). Conclusion: The Fe{sup 2+} oxidation-based system was superior as 4D dosimeters for MR-guided radiation therapy due to its higher sensitivity in both optical and MR signal readout and feasibility for real-time 4D dose readout. The Fe{sup 3+} reduction system is recommended for high dose applications. This material is based upon work supported by the National Science Foundation Graduate Research Fellowship Program under Grant No. LH-102SPS.

60 APPLIED LIFE SCIENCES↗

TEM Cell Testing of Cable Noise Reduction Techniques From 2 MHz to 200 MHz - Part 1

This paper presents empirical results of cable noise reduction techniques as demonstrated in a TEM cell operating with radiated fields from 2 - 200 MHz. It is the first part of a two-paper series. This first paper discusses cable types and shield connections. In the second paper, the effects of load and source resistances and chassis connections are examined. For each topic, well established theories are compared to data from a real-world physical system. Finally, recommendations for minimizing cable susceptibility (and thus cable emissions) are presented. There are numerous papers and textbooks that present theoretical analyses of cable noise reduction techniques. However, empirical data is often targeted to low frequencies (e.g. <50 KHz) or high frequencies (>100 MHz). Additionally, a comprehensive study showing the relative effects of various noise reduction techniques is needed. These include the use of dedicated return wires, twisted wiring, cable shielding, shield connections, changing load or source impedances, and implementing load- or source-to-chassis isolation. We have created an experimental setup that emulates a real-world electrical system, while still allowing us to independently vary a host of parameters. The goal of the experiment was to determine the relative effectiveness of various noise reduction techniques when the cable is in the presence of radiated emissions from 2 MHz to 200 MHz. The electronic system (Fig. 1) consisted of two Hammond shielded electrical enclosures, one containing the source resistance, and the other containing the load resistance. The boxes were mounted on a large aluminium plate acting as the chassis. Cables connecting the two boxes measured 81 cm in length and were attached to the boxes using standard D38999 military-style connectors. The test setup is shown in Fig. 2. Electromagnetic fields were created using an HP8657B signal generator, MiniCircuits ZHL-42W-SMA amplifier, and an EMCO 5103 TEM cell. Measurements were taken using an Agilent E4401B spectrum analyzer and HP1141a differential probes.

Bradley, Arthur T.↗

TEM Cell Testing of Cable Noise Reduction Techniques from 2 MHz to 200 MHz -- Part 2

This paper presents empirical results of cable noise reduction techniques as demonstrated in a TEM cell operating with radiated fields from 2 - 200 MHz. It is the second part of a two-paper series. The first paper discussed cable types and shield connections. In this second paper, the effects of load and source resistances and chassis connections are examined. For each topic, well established theories are compared to data from a real-world physical system. Finally, recommendations for minimizing cable susceptibility (and thus cable emissions) are presented. There are numerous papers and textbooks that present theoretical analyses of cable noise reduction techniques. However, empirical data is often targeted to low frequencies (e.g. <50 KHz) or high frequencies (>100 MHz). Additionally, a comprehensive study showing the relative effects of various noise reduction techniques is needed. These include the use of dedicated return wires, twisted wiring, cable shielding, shield connections, changing load or source impedances, and implementing load- or source-to-chassis isolation. We have created an experimental setup that emulates a real-world electrical system, while still allowing us to independently vary a host of parameters. The goal of the experiment was to determine the relative effectiveness of various noise reduction techniques when the cable is in the presence of radiated emissions from 2 MHz to 200 MHz.

Bradley, Arthur T.↗

Transient Modeling and Analysis of a Metabolic Heat-Regenerated Temperature Swing Adsorption (MTSA) System for a PLSS

A Metabolic heat-regenerated Temperature Swing Adsorption (MTSA) system is being developed for carbon dioxide, water and thermal control in a lunar and martian portable life support system (PLSS). A previous system analysis was performed to evaluate the impact of MTSA on PLSS design. That effort was Mars specific and assumed liquid carbon dioxide (LCO2) coolant made from martian resources. Transient effects were not considered but rather average conditions were used throughout the analysis. This effort takes into further consideration the transient effects inherent in the cycling MTSA system as well as assesses the use of water as coolant. Standard heat transfer, thermodynamic, and heat exchanger methods are presented to conduct the analysis. Assumptions and model verification are discussed. The tool was used to perform various system studies. Coolant selection was explored and takes into account different operational scenarios as the minimum bed temperature is driven by the sublimation temperature of the coolant (water being significantly higher than LCO2). From this, coolant mass is sized coupled with sorbent bed mass because MTSA adsorption performance decreases with increasing sublimation temperature. Reduction in heat exchanger performance and even removal of certain heat exchangers, like a recuperative one between the two sorbent beds, is also investigated. Finally, the coolant flow rate is varied over the cycle to determine if there is a more optimal means of cooling the bed from a mass perspective. Results of these studies and subsequent recommendations for system design are presented.

Iacomini, Christie↗

Load Monitoring CEC/LMTF Load Research Program

This white paper addresses the needs, options, current practices of load monitoring. Recommendations on load monitoring applications and future directions are also presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digial Technology Qualification Task 2 - Suitability of Digital Alternatives to Analog Sensors and Actuators

The next generation reactors in the U.S. are an opportunity for vendors to build new reactor technology with advanced Instrumentation and Control Systems (control rooms, DCS, etc.). The advances made in the development of many current generation operating reactors in other parts of the world are being used in the design and construction of new plants. These new plants are expected to have fully integrated digital control rooms, computerized procedures, integrated surveillance testing with on-line monitoring and a major effort toward improving the O&M and fault survivability of the overall systems. In addition the designs are also incorporating major improvements in the man-machine interface based on lessons learned in nuclear and other industries. The above relates primarily to the scope of supply in instrumentation and control systems addressed by Chapter 7 of the Standard Review Plan (SRP) NUREG-0800 (Reference 9.5), and the associated Balance of Plant (BOP) I&C systems. This does not relate directly to the actuator and motor, breaker, initiation circuitry, valve position, etc. which is the subject of this report and normally outside of the traditional Distributed Control System (DCS), for both safety and non-safety systems. The recommendations presented in this report will be used as input to I&C research programming for the implementation of lessons learned during the early phases of new build both for large light water reactors (LWR) and also small modular reactors (SMR). This report is intended to support current research plans and provide user (vendor, owner-operator) input to the optimization of these research plans.

99 GENERAL AND MISCELLANEOUS↗

Toward Time Synchronization in Delay Tolerant Network based Solar System Internetworking

The expanding presence in space will place an increased dependency on networked communications– a scalable communications infrastructure; that is, the Solar System Internet (SSI). Upcoming developments towards a SSI include NASA’s upcoming LunaNet, or lunar Internet, which provides multi-hop multi-path communications using Delay Tolerant Networking (DTN). DTN has been an active area of research and development, particularly in routing, security, and optimization. DTNs are marked by mobility, disconnection, and a wide variance of latencies (propagation and processing delays). In this paper, we outline progress towards a theory of time synchronization across such a network. An underlying assumption of DTN is that the network is time synchronized already, rather than synchronization being provided as a service. While this is necessary for schedule-based routing, which is necessarily prevalent in DTNs, it is so deeply ingrained as to be built into the primary unit of data in DTNs– the bundle. Indeed, a bundle’s creation timestamp and its time to live (called the lifetime) are based on time, and there are special recommendations for systems that lack accurate clocks. The assumption of time synchronization makes sense when limiting considerations to smaller-scale and more traditional space communication. However, just as end-to-end connectivity cannot be guaranteed in DTNs, neither can access to a reference or authoritative clock. In this more general case, it might be necessary to synchronize over time-varying meshes, and perhaps even to consider relativistic effects. Moreover, by imposing synchronization restrictions in order to sustain a network, the effectiveness of the network to achieve scalability will be necessarily muted. To work towards a time synchronization theory for DTNs, we build upon past successes in modeling DTNs using time-varying graphs and sheaves. This includes error and limitation estimation, which allows one to define domains over which schedule-based routing is possible, up to some threshold sensitivity. Despite the theoretical nature of these results, the approaches taken are also algorithmic, and hence lend themselves to practical implementations. The paper concludes with comparisons of the various methods along with suggestions for future work.

Delay Tolerant Networking↗

Improving the Fidelity of Capability & Resource Weighting in A Probalistic Risk Assessment Model for Spaceflight

INTRODUCTION NASA’s Informing Mission Planning via Analysis of Complex Tradespaces (IMPACT) tool uses Probabilistic Risk Assessment (PRA) to provide an evidence-based, data-driven estimate of how medical system capabilities affect mission outcomes. IMPACT maps condition incidence to available resources thereby facilitating the calculation of outcome metrics that allow the estimation of mission medical risk. Conditions can be nominally categorized as either treated or untreated depending on the availability of necessary diagnostic and therapeutic capabilities. This categorization enables IMPACT to estimate the effect of various medical system configurations on mission outcomes such as crew mortality, disability, crew member down-time, return to duty/recovery, and need for evacuation. IMPACT currently employs an equal weighting, “partial credit” approach to define treatment in which each of the capabilities associated with a given condition contributes an equal amount to management of the condition. This feature enables IMPACT to report values in between “fully untreated” and “fully treated” based on the proportion of capabilities available within the model. However, as is normal in medical/clinical practice, not all individual capabilities contribute equally to medical care. For example, the ability to provide intramuscular epinephrine during an anaphylactic episode contributes more likelihood of overall management success than does the administration of oral diphenhydramine. We hypothesize that weighting the relative contribution of each capability to each specific condition will improve outcome prediction and therefore will better provide mission planners with more nuanced and accurate options when designing space medical systems. METHODS Using a five-point Fibonacci scaling sequence (1, 2, 3, 5, 8) subject matter experts from NASA’s Exploration Medical Capabilities (ExMC) element assigned relative contribution weighting values to each identified capability within IMPACT. Since the relative importance of each capability varies depending on the specific condition, the resulting “partial” weighting was completed for more than 1,600 individual weighting assignments for 666 capabilities across 121 conditions. Each assignment required three-physician concurrence based on the overall importance of the capability to the diagnosis and management of the condition being considered and the difficulty with which it could be improvised by the crew. Once complete, 100,000 IMPACT simulations were run for a 6-month Lunar mission with a 30-day surface stay to evaluate the effect of this modification of the model. RESULTS Partial weighting significantly decreased predicted task time loss (TTL), evacuation, and loss of crew life without causing significant changes to the recommended medical system design. CONCLUSIONS The paucity of real-world referent data to support long-duration space missions of this type limits the ability to judge one predictive analytics method as superior to another. However, since the proposed method significantly reduces and optimizes outcome risks—without changing the medical system design—incorporating a partial weighting methodology is likely to provide a more accurate and operationally-relevant representation of medical risk without compromising IMPACTs ability to inform overarching medical system requirements.

Steller JG↗

Post-Newtonian metric of general relativity including all the c{sup -4} terms in the continuity of the IAU2000 resolutions

The Solar System metric recommended by the International Astronomical Union (IAU) resolution B1.3, during its 24th general assembly, allows light propagation calculations until order c{sup -3} only. However, an increasing number of forthcoming spatial experiments will require a modelization of the gravitational field including all the c{sup -4} terms in the metric to describe light propagation at the required precision. This will be the case for missions planned or in project, like TIPO, ASTROD, LATOR. Hence, it is necessary to extend the IAU framework to include all the relevant contributing terms. This paper proposes such an extension.

79 ASTRONOMY AND ASTROPHYSICS↗

Smoothing out step changes of LMP

The locational marginal pricing methodology may lead to a step change when system load grows, creating higher financial risk, especially for small and medium-sized market participants. A proposed continuous LMP method is a straightforward solution to eliminate these step changes when load grows. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Unlocking the smart grid

The country has progressed in a relatively short time from rotary dial phones to computers, cell phones, and iPads. With proper planning and orderly policy implementation, the same will happen with the Smart Grid. Here are some suggestions on how to proceed. (author)

24 POWER TRANSMISSION AND DISTRIBUTION↗

Municipal solid waste management in Rasht City, Iran

Pollution and health risks generated by improper solid waste management are important issues concerning environmental management in developing countries. In most cities, the use of open dumps is common for the disposal of wastes, resulting in soil and water resource contamination by leachate in addition to odors and fires. Solid waste management infrastructure and services in developing countries are far from achieving basic standards in terms of hygiene and efficient collection and disposal. This paper presents an overview of current municipal solid waste management in Rasht city, Gilan Province, Iran, and provides recommendations for system improvement. The collected data of different MSW functional elements were based on data from questionnaires, visual observations of the authors, available reports and several interviews and meetings with responsible persons. Due to an increase in population and changes in lifestyle, the quantity and quality of MSW in Rasht city has changed. Lack of resources, infrastructure, suitable planning, leadership, and public awareness are the main challenges of MSW management of Rasht city. However, the present situation of solid waste management in this city, which generates more than 400 tons/d, has been improved since the establishment of an organization responsible only for solid waste management. Source separation of wastes and construction of a composting plant are the two main activities of the Rasht Municipality in recent years.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Indoor air quality in 24 California residences designed as high-performance homes

Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California. Although the mechanically vented homes were six times as airtight as non-mechanically ventilated homes (medians of 1.1 and 6.1 ACH 50 , n=11 and n=8, respectively), their use of mechanical ventilation systems and possibly window operation meant their median air exchange rates were almost the same (0.30 versus 0.32 hr -1 , n=8 and n=8, respectively). Pollutant levels were also similar in vented and unvented homes. In addition, these similarities were achieved despite numerous observed faults in complex mechanical ventilation systems. More rigorous commissioning is still recommended. Cooking exhaust systems were used inconsistently and several suffered from design flaws. Failure to follow best practices led to IAQ problems in some cases. Ambient nitrogen dioxide standards were exceeded or nearly so in four homes that either used gas ranges with standing pilots, or in Passive House-style homes that used gas cooking burners without venting range hoods. Homes without active particle filtration had particle count concentrations approximately double those in homes with enhanced filtration. The majority of homes reported using low-emitting materials; consistent with this, formaldehyde levels were approximately half those in conventional, new CA homes built before 2008. Emissions of ultrafine particles (with diameters <100 nm) were dramatically lower on induction electric cooktops, compared with either gas or resistance electric models. These results indicate that high performance homes can achieve acceptable and even exceptional IAQ by providing adequate general mechanical ventilation, using low-emitting materials, providing mechanical particle filtration, incorporating well-designed exhaust ventilation for kitchens and bathrooms, and educating occupants to use the kitchen and bath ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

THE PROPOSED QUADRUPLE SYSTEM SZ HERCULIS: REVISED LITE MODEL AND ORBITAL STABILITY STUDY

In a recent study, Lee et al. presented new photometric follow-up timing observations of the semidetached binary system SZ Herculis and proposed the existence of two hierarchical cirumbinary companions. Based on the light-travel time effect, the two low-mass M-dwarf companions are found to orbit the binary pair on moderate to high eccentric orbits. The derived periods of these two companions are close to a 2:1 mean-motion orbital resonance. We have studied the stability of the system using the osculating orbital elements as presented by Lee et al. Results indicate an orbit-crossing architecture exhibiting short-term dynamical instabilities leading to the escape of one of the proposed companions. We have examined the system's underlying model parameter space by following a Monte Carlo approach and found an improved fit to the timing data. A study of the stability of our best-fitting orbits also indicates that the proposed system is generally unstable. If the observed anomalous timing variations of the binary period is due to additional circumbinary companions, then the resulting system should exhibit a long-term stable orbital configuration much different from the orbits suggested by Lee et al. We, therefore, suggest that based on Newtonian-dynamical considerations, the proposed quadruple system cannot exist. To uncover the true nature of the observed period variations of this system, we recommend future photometric follow-up observations that could further constrain eclipse-timing variations and/or refine light-travel time models.

79 ASTRONOMY AND ASTROPHYSICS↗

PMU Placement for Enhancing Dynamic Observability of a Power Grid

Power grids are operated in an increasingly complicated environment. However, operators lack effective and accurate tools for real-time monitoring and control of power systems. The U.S. Department of Energy, along with several utilities and system operators, is making a major $108 million investment in the Western Interconnection for phasor measurement unit (PMU) installation and phasor application development. This phasor measurement network opens up many opportunities for the estimation and prediction of power system states in real time, which enable operators to evaluate the system dynamic security in advance and allow them more time to respond to disturbances. Kalman filter based dynamic state estimation offers a solution suitable for this purpose. Our work indicates that the performance of Kalman filters in dynamic state estimation would degrade if PMU measurements cannot adequately capture the system dynamics. This paper develops a framework to identify how to place PMUs to improve dynamic observability of the power grid. Simulation results validate the concept, and the guidelines for PMU placement are derived.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Patient radiation dose in prospectively gated axial CT coronary angiography and retrospectively gated helical technique with a 320-detector row CT scanner

Purpose: The aim of this study was to evaluate radiation dose to patients undergoing computed tomography coronary angiography (CTCA) for prospectively gated axial (PGA) technique and retrospectively gated helical (RGH) technique. Methods: Radiation doses were measured for a 320-detector row CT scanner (Toshiba Aquilion ONE) using small sized silicon-photodiode dosimeters, which were implanted at various tissue and organ positions within an anthropomorphic phantom for a standard Japanese adult male. Output signals from photodiode dosimeters were read out on a personal computer, from which organ and effective doses were computed according to guidelines published in the International Commission on Radiological Protection Publication 103. Results: Organs that received high doses were breast, followed by lung, esophagus, and liver. Breast doses obtained with PGA technique and a phase window width of 16% at a simulated heart rate of 60 beats per minute were 13 mGy compared to 53 mGy with RGH technique using electrocardiographically dependent dose modulation at the same phase window width as that in PGA technique. Effective doses obtained in this case were 4.7 and 20 mSv for the PGA and RGH techniques, respectively. Conversion factors of dose length product to the effective dose in PGA and RGH were 0.022 and 0.025 mSv mGy{sup -1} cm{sup -1} with a scan length of 140 mm. Conclusions: CTCA performed with PGA technique provided a substantial effective dose reduction, i.e., 70%-76%, compared to RGH technique using the dose modulation at the same phase windows as those in PGA technique. Though radiation doses in CTCA with RGH technique were the same level as, or some higher than, those in conventional coronary angiography (CCA), the use of PGA technique reduced organ and effective doses to levels less than CCA except for breast dose.

60 APPLIED LIFE SCIENCES↗

MO-G-18A-01: Radiation Dose Reducing Strategies in CT, Fluoroscopy and Radiography

Advances in medical x-ray imaging have provided significant benefits to patient care. According to NCRP 160, there are more than 400 million x-ray procedures performed annually in the United States alone that contributes to nearly half of all the radiation exposure to the US population. Similar growth trends in medical x-ray imaging are observed worldwide. Apparent increase in number of medical x-ray imaging procedures, new protocols and the associated radiation dose and risk has drawn considerable attention. This has led to a number of technological innovations such as tube current modulation, iterative reconstruction algorithms, dose alerts, dose displays, flat panel digital detectors, high efficient digital detectors, storage phosphor radiography, variable filters, etc. that are enabling users to acquire medical x-ray images at a much lower radiation dose. Along with these, there are number of radiation dose optimization strategies that users can adapt to effectively lower radiation dose in medical x-ray procedures. The main objectives of this SAM course are to provide information and how to implement the various radiation dose optimization strategies in CT, Fluoroscopy and Radiography. Learning Objectives: To update impact of technological advances on dose optimization in medical imaging. To identify radiation optimization strategies in computed tomography. To describe strategies for configuring fluoroscopic equipment that yields optimal images at reasonable radiation dose. To assess ways to configure digital radiography systems and recommend ways to improve image quality at optimal dose.

60 APPLIED LIFE SCIENCES↗