Search NASA⌕ Search

SEARCH · Search NASA

Results for “Related References”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The Behm Acoustic Sounder for Airplanes with Reference to Its Accuracy

Relative altimetry is of great importance for increasing the safety in aerial transportation, because it makes possible safe flying at night, by poor visibility, and when landing. Among the instruments of this type is the Behm sounder, which operates on an acoustic principle. Acoustic altimetry in general and the Behn sounder, in particular, are covered in this report.

Schreiber, Ernest↗

Treatment-Related Toxicity in Patients With Early-Stage Non-Small Cell Lung Cancer and Coexisting Interstitial Lung Disease: A Systematic Review

Purpose: Definitive treatment for patients with early-stage non-small cell lung cancer (ES-NSCLC) is usually well tolerated. Patients with ES-NSCLC and coexisting interstitial lung disease (ILD) are at increased risk of severe treatment-related toxicity after definitive therapy. The main objective of this systematic review is to provide a pooled estimation of treatment-related mortality and ILD-specific toxicity in this population of patients and to identify trends for further study. Methods and Materials: The MEDLINE and Embase databases were queried from respective dates of inception to January 2016. Studies that included patients who underwent definitive treatment for ES-NSCLC not combined with other treatments were included. Patients with oligometastases who were treated with aggressive palliation were included if it did not constitute the majority of patients in a specific study. The results were summarized with weighted proportions according to the sample size of individual studies. Results: Overall, 3056 records were reviewed and 50 journal articles were included in the abstraction. The weighted proportion of treatment-related mortality (and ILD-specific toxicity) in primarily medically inoperable patients was as follows: stereotactic ablative radiation therapy (SABR) 15.6% (25%), particle beam therapy 4.3% (18.2%) and radiofrequency ablation (RFA) 8.7% (25%). The data for medically operable patients who underwent surgery were extracted for reference. Treatment-related mortality and ILD-specific toxicity were 2.2% and 12%, respectively, in the surgical population. On analysis of reported SABR dose parameters, V20 ≤ 6.5% and mean lung dose ≤4.5 Gy were found to be metrics associated with reduced mortality. Conclusion: A consistently high level of treatment-related mortality and ILD-specific toxicity was observed in primarily medically inoperable patients treated with SABR, particle beam therapy, and RFA. For these patients, curative treatment should be considered in the context of the high toxicity rates and overall poor prognosis. Stringent radiation dosimetric parameters may result in reduced toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New work on updating and extending the nuclear data standards

An International Atomic Energy Agency (IAEA) Data Development Project was initiated to provide a mechanism for allowing new experimental data and improvements in evaluation procedures to be incorporated into new evaluations of the standards. The work on this project is ongoing. In the past very long periods sometimes occurred between evaluations of the standards. Through the use of this Project, such long periods should not occur. Work on the cross section standards through this Project has included an update of the experimental data to be used in the cross section standards evaluations, a study of the uncertainties obtained in the international standards evaluation, and improvements in the smoothing procedure for capture cross sections. It was decided that this Project should have a broader range of activities than just the cross section standards and thus encompass standards related activities. The following are being investigated: improvements in the gold cross section at energies below where it is considered a standard and work on certain cross sections that are not as well known as the cross section standards but could be very useful as reference cross sections relative to which certain types of cross section measurements can be made. This work includes prompt gamma-ray production in fast neutron-induced reactions, and work on the {sup 252}Cf spontaneous fission neutron spectrum and the {sup 235}U thermal neutron fission spectrum. Most of the data investigated through this Project are used in dosimetry applications. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precise Relative Earthquake Magnitudes from Cross Correlation

We present a method to estimate precise relative magnitudes using cross correlation of seismic waveforms. Our method incorporates the intercorrelation of all events in a group of earthquakes, as opposed to individual event pairings relative to a reference event. This method works well when a reliable reference event does not exist. We illustrate the method using vertical strike-slip earthquakes located in the northeast Pacific and Panama fracture zone regions. Our results are generally consistent with the Global Centroid Moment Tensor catalog, which we use to establish a baseline for the relative event sizes.

58 GEOSCIENCES↗

Performance Assessment of a Photonic Radiative Cooling System for Office Buildings

Spectrally selective materials show high technical potential for use as radiative cooling heat exchangers for buildings. Recent work by Stanford University has applied a photonic approach to tailor the optical properties of a coating material. In a prototype test, a radiative cooler based on that photonic material has demonstrated the ability to maintain radiator surfaces at below-ambient temperatures in the presence of intense, direct sunlight. This paper presents the simulation and parametric analysis of photonic radiative cooling system that integrates the use of the photonic radiative cooler and radiant floor cooling via the whole energy simulation program EnergyPlus. The simulation was made for a medium office building with three floors and a total floor area of 5,000 m2. Three key design parameters including the storage tank size, the radiator area, and the number of floors are expected to have a large impact on system performance were investigated in this paper. The results show that the percentage of cooling electricity savings from the photonic radiative cooling system relative to a reference variable-air-volume system has a linear relationship with the radiator area, and a quadratic correlation with both tank size and the number of floors. The findings from this parametric analysis are valuable to understand how component sizing affects system performance.

Wang, Weimin↗

A Hybrid Line List for CH4 and Hot Methane Continuum

Molecular line lists (a catalogue of transition frequencies and line strengths) are important for modelling absorption and emission processes in atmospheres of different astronomical objects, such as cool stars and exoplanets. In order to be applicable for high temperatures, line lists for molecules like methane must contain billions of transitions, which makes their direct (line-by-line) application in radiative transfer calculations impracticable. Here we suggest a new, hybrid line list format to mitigate this problem, based on the idea of temperature-dependent absorption continuum. Methods. The line list is partitioned into a large set of relatively weak lines and a small set of important, stronger lines. The weaker lines are then used either to construct a temperature-dependent (but pressure-independent) set of intensity cross sections or are blended into a greatly reduced set of super-lines. The strong lines are kept in the form of temperature independent Einstein A coefficients. Results. A line list for methane is constructed as a combination of 17 million strong absorption lines relative to the reference absorption spectra and a background methane continuum in two temperature-dependent forms, of cross sections and super-lines. This approach eases the use of large high temperature line lists significantly as the computationally expensive calculation of pressure dependent profiles only need to be performed for a relatively small number of lines. Both the line list and cross sections were generated using a new 34 billion methane line list (34 to10), which extends the 10to10 line list to higher temperatures (up to 2000 K). The new hybrid scheme can be applied to any large line lists containing billions of transitions. We recommend to use super-lines generated on a high resolution grid based on resolving power R = 1,000,000 to model the molecular continuum as a more flexible alternative to the temperature dependent cross sections.

Line Profiles↗

Nanoradian Ground-Based Astrometry, Optical Navigation, and Artificial Reference Stars

Spacecraft carrying optical communication lasers can be treated as artificial stars, whose relative astrometry to Gaia reference stars provides spacecraft positions in the plane-of-sky for optical navigation. To be comparable to current Deep Space Network delta-Differential One-way Ranging measurements, thus sufficient for navigation, nanoradian optical astrometry is required. Here we describe our error budget, techniques for achieving nanoradian level ground-base astrometry, and preliminary results from a 1 m telescope. We discuss also how these spacecraft may serve as artificial reference stars for adaptive optics, high precision astrometry to detect exoplanets, and tying reference frames defined by radio and optical measurements.

optical navigation↗

Measurement of regional compliance using 4DCT images for assessment of radiation treatment

Purpose: Radiation-induced damage, such as inflammation and fibrosis, can compromise ventilation capability of local functional units (alveoli) of the lung. Ventilation function as measured with ventilation images, however, is often complicated by the underlying mechanical variations. The purpose of this study is to present a 4DCT-based method to measure the regional ventilation capability, namely, regional compliance, for the evaluation of radiation-induced lung damage. Methods: Six 4DCT images were investigated in this study: One previously used in the generation of a POPI model and the other five acquired at Henry Ford Health System. A tetrahedral geometrical model was created and scaled to encompass each of the 4DCT image domains. Image registrations were performed on each of the 4DCT images using a multiresolution Demons algorithm. The images at the end of exhalation were selected as a reference. Images at other exhalation phases were registered to the reference phase. For the POPI-modeled patient, each of these registration instances was validated using 40 landmarks. The displacement vector fields (DVFs) were used first to calculate the volumetric variation of each tetrahedron, which represents the change in the air volume. The calculated results were interpolated to generate 3D ventilation images. With the computed DVF, a finite element method (FEM) framework was developed to compute the stress images of the lung tissue. The regional compliance was then defined as the ratio of the ventilation and stress values and was calculated for each phase. Based on iterative FEM simulations, the potential range of the mechanical parameters for the lung was determined by comparing the model-computed average stress to the clinical reference value of airway pressure. The effect of the parameter variations on the computed stress distributions was estimated using Pearson correlation coefficients. Results: For the POPI-modeled patient, five exhalation phases from the start to the end of exhalation were denoted by P{sub i}, i=1,...,5, respectively. The average lung volume variation relative to the reference phase (P{sub 5}) was reduced from 18% at P{sub 1} to 4.8% at P{sub 4}. The average stress at phase P{sub i} was 1.42, 1.34, 0.74, and 0.28 kPa, and the average regional compliance was 0.19, 0.20, 0.20, and 0.24 for i=1,...,4, respectively. For the other five patients, their average R{sub v} value at the end-inhalation phase was 21.1%, 19.6%, 22.4%, 22.5%, and 18.8%, respectively, and the regional compliance averaged over all six patients is 0.2. For elasticity parameters chosen from the potential parameter range, the resultant stress distributions were found to be similar to each other with Pearson correlation coefficients greater than 0.81. Conclusions: A 4DCT-based mechanical model has been developed to calculate the ventilation and stress images of the lung. The resultant regional compliance represents the lung's elasticity property and is potentially useful in correlating regions of lung damage with radiation dose following a course of radiation therapy.

60 APPLIED LIFE SCIENCES↗

Virtual space and 2-dimensional effects in perspective displays

When interpreting three dimensional spatial relationships presented on a two dimensional display surface, the viewer is required to mentally reconstruct the original information. This reconstruction is influenced by both the perspective geometry of the displayed image and the viewer's eye position relative to the display. In a study which manipulated these variables, subjects judged the azimuth direction of a target object relative to a reference object fixed in the center of a perspective display. The results support a previously developed model which predicted that the azimuth judgement error would be a sinusoidal function of stimulus azimuth. The amplitude of this function was correctly predicted to be systematically modulated by both the perspective geometry of the image and the viewer's eye position relative to the screen. Interaction of the two components of the model, the virtual space effect and the 3D-to-2D projection effect, predicted the relative amplitudes of the sinusoidal azimuth error functions for the various conditions of the experiment. Mean azimuth judgements in some directions differed by as much as 25 degrees as a result of different combinations of eye position and image geometry. The results illustrate the need to consider the effects of perspective geometry when designing spatial information instruments, and show the model to be a reliable predictor of average performance.

Mcgreevy, M. W.↗

CombAlign: a code for generating a one-to-many sequence alignment from a set of pairwise structure-based sequence alignments

In order to better define regions of similarity among related protein structures, it is useful to identify the residue-residue correspondences among proteins. Few codes exist for constructing a one-to-many multiple sequence alignment derived from a set of structure or sequence alignments, and a need was evident for creating such a tool for combining pairwise structure alignments that would allow for insertion of gaps in the reference structure. This report describes a new Python code, CombAlign, which takes as input a set of pairwise sequence alignments (which may be structure based) and generates a one-to-many, gapped, multiple structure- or sequence based sequence alignment (MSSA). The use and utility of CombAlign was demonstrated by generating gapped MSSAs using sets of pairwise structure-based sequence alignments between structure models of the matrix protein (VP40) and pre-small/secreted glycoprotein (sGP) of Reston Ebolavirus and the corresponding proteins of several other filoviruses. The gapped MSSAs revealed structure-based residue-residue correspondences, which enabled identification of structurally similar versus differing regions in the Reston proteins compared to each of the other corresponding proteins. CombAlign is a new Python code that generates a one-to-many, gapped, multiple structure- or sequence-based sequence alignment (MSSA) given a set of pairwise sequence alignments (which may be structure based). CombAlign has utility in assisting the user in distinguishing structurally conserved versus divergent regions on a reference protein structure relative to other closely related proteins. CombAlign was developed in Python 2.6, and the source code is available for download from the GitHub code repository.

59 BASIC BIOLOGICAL SCIENCES↗

Estimating Engine Airflow in Gas-Turbine Powered Aircraft with Clean and Distorted Inlet Flows

The P404-GF-400 Powered F/A-18A High Alpha Research Vehicle (HARV) was used to examine the impact of inlet-generated total-pressure distortion on estimating levels of engine airflow. Five airflow estimation methods were studied. The Reference Method was a fan corrected airflow to fan corrected speed calibration from an uninstalled engine test. In-flight airflow estimation methods utilized the average, or individual, inlet duct static- to total-pressure ratios, and the average fan-discharge static-pressure to average inlet total-pressure ratio. Correlations were established at low distortion conditions for each method relative to the Reference Method. A range of distorted inlet flow conditions were obtained from -10 deg. to +60 deg. angle of attack and -7 deg. to +11 deg. angle of sideslip. The individual inlet duct pressure ratio correlation resulted in a 2.3 percent airflow spread for all distorted flow levels with a bias error of -0.7 percent. The fan discharge pressure ratio correlation gave results with a 0.6 percent airflow spread with essentially no systematic error. Inlet-generated total-pressure distortion and turbulence had no significant impact on the P404-GE400 engine airflow pumping. Therefore, a speed-flow relationship may provide the best airflow estimate for a specific engine under all flight conditions.

Williams, J. G.↗

A linear, separable two-parameter model for dual energy CT imaging of proton stopping power computation

Purpose: To evaluate the accuracy and robustness of a simple, linear, separable, two-parameter model (basis vector model, BVM) in mapping proton stopping powers via dual energy computed tomography (DECT) imaging. Methods: The BVM assumes that photon cross sections (attenuation coefficients) of unknown materials are linear combinations of the corresponding radiological quantities of dissimilar basis substances (i.e., polystyrene, CaCl{sub 2} aqueous solution, and water). The authors have extended this approach to the estimation of electron density and mean excitation energy, which are required parameters for computing proton stopping powers via the Bethe–Bloch equation. The authors compared the stopping power estimation accuracy of the BVM with that of a nonlinear, nonseparable photon cross section Torikoshi parametric fit model (VCU tPFM) as implemented by the authors and by Yang et al. [“Theoretical variance analysis of single- and dual-energy computed tomography methods for calculating proton stopping power ratios of biological tissues,” Phys. Med. Biol. 55, 1343–1362 (2010)]. Using an idealized monoenergetic DECT imaging model, proton ranges estimated by the BVM, VCU tPFM, and Yang tPFM were compared to International Commission on Radiation Units and Measurements (ICRU) published reference values. The robustness of the stopping power prediction accuracy of tissue composition variations was assessed for both of the BVM and VCU tPFM. The sensitivity of accuracy to CT image uncertainty was also evaluated. Results: Based on the authors’ idealized, error-free DECT imaging model, the root-mean-square error of BVM proton stopping power estimation for 175 MeV protons relative to ICRU reference values for 34 ICRU standard tissues is 0.20%, compared to 0.23% and 0.68% for the Yang and VCU tPFM models, respectively. The range estimation errors were less than 1 mm for the BVM and Yang tPFM models, respectively. The BVM estimation accuracy is not dependent on tissue type and proton energy range. The BVM is slightly more vulnerable to CT image intensity uncertainties than the tPFM models. Both the BVM and tPFM prediction accuracies were robust to uncertainties of tissue composition and independent of the choice of reference values. This reported accuracy does not include the impacts of I-value uncertainties and imaging artifacts and may not be achievable on current clinical CT scanners. Conclusions: The proton stopping power estimation accuracy of the proposed linear, separable BVM model is comparable to or better than that of the nonseparable tPFM models proposed by other groups. In contrast to the tPFM, the BVM does not require an iterative solving for effective atomic number and electron density at every voxel; this improves the computational efficiency of DECT imaging when iterative, model-based image reconstruction algorithms are used to minimize noise and systematic imaging artifacts of CT images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Constraining Particle Variation in Lunar Regolith for Simulant Design

Simulants are used by the lunar engineering community to develop and test technologies for In Situ Resource Utilization (ISRU), excavation and drilling, and for mitigation of hazards to machinery and human health. Working with the United States Geological Survey (USGS), other NASA centers, private industry and academia, Marshall Space Flight Center (MSFC) is leading NASA s lunar regolith simulant program. There are two main efforts: simulant production and simulant evaluation. This work requires a highly detailed understanding of regolith particle type, size, and shape distribution, and of bulk density. The project has developed Figure of Merit (FoM) algorithms to quantitatively compare these characteristics between two materials. The FoM can be used to compare two lunar regolith samples, regolith to simulant, or two parcels of simulant. In work presented here, we use the FoM algorithm to examine the variance of particle type in Apollo 16 highlands regolith core and surface samples. For this analysis we have used internally consistent particle type data for the 90-150 m fraction of Apollo core 64001/64002 from station 4, core 60009/60010 from station 10, and surface samples from various Apollo 16 stations. We calculate mean modal compositions for each core and for the group of surface samples and quantitatively compare samples of each group to its mean as a measurement of within-group variance; we also calculate an FoM for every sample against the mean composition of 64001/64002. This gives variation with depth at two locations and between Apollo 16 stations. Of the tested groups, core 60009/60010 has the highest internal variance with an average FoM score of 0.76 and core 64001/64002 has the lowest with an average FoM of 0.92. The surface samples have a low but intermediate internal variance with an average FoM of 0.79. FoM s calculated against the 64001/64002 mean reference composition range from 0.79-0.97 for 64001/64002, from 0.41-0.91 for 60009/60010, and from 0.54-0.93 for the surface samples. Six samples fall below 0.70, and they are also the least mature (i.e., have the lowest I(sub s)/FeO). Because agglutinates are the dominant particle type and the agglutinate population increases with sample maturity (I(sub s)/FeO), the maturity of the sample relative to the reference is a prime determinant of the particle type FoM score within these highland samples.

Schrader, Christian M.↗

Solar power satellite system sizing tradeoffs

Technical and economic tradeoffs of smaller solar power satellite systems configured with larger antennas, reduced output power, and smaller rectennas, are considered. The differential costs in electricity for seven antenna/rectenna configurations operating at 2.45 GHz and five satellite systems operating at 5.8 GHz are calculated. Two 2.45 GHz configurations dependent upon the ionospheric power density limit are chosen as examples. If the ionospheric limit could be increased to 54 mW sq/cm from the present 23 mW sq/cm level, a 1.53 km antenna satellite operating at 2.45 GHz would provide 5.05 GW of output power from a 6.8 km diameter rectenna. This system gives a 54 percent reduction in rectenna area relative to the reference solar power satellite system at a modest 17 percent increase in electricity costs. At 5.8 GHz, an 0.75 km antenna providing 2.72 GW of power from a 5.8 km diameter rectenna is selected for analysis. This configuration would have a 67 percent reduction in rectenna area at a 36 percent increase in electricity costs. Ionospheric, atmospheric, and thermal limitations are discussed. Antenna patterns for three configurations to show the relative main beam and sidelobe characteristics are included.

Arndt, G. D.↗

Relative size perception at a distance is best at eye level

Relative size judgments were collected for two objects at 30.5 m and 23.8 from the observer in order to assess how performance depends on the relationship between the size of the objects and the eye level of the observer. In three experiments in an indoor hallway and in one experiment outdoors, accuracy was higher for objects in the neighborhood of eye level. We consider these results in the light of two hypotheses. One proposes that observers localize the horizon as a reference for judging relative size, and the other proposes that observers perceive the general neighborhood of the horizon and then employ a height-in-visual-field heuristic. The finding that relative size judgments are best around the horizon implies that information that is independent of distance perception is used in perceiving size.

NASA Center ARC↗

Microarcsecond relative astrometry from the ground with a diffractive pupil

The practical use of astrometry to detect exoplanets via the reflex motion of the parent star depends critically on the elimination of systematic floors in imaging systems. In the diffractive pupil technique proposed for space-based detection of exo-earths, extended diffraction spikes generated by a dotted primary mirror are referenced against a wide-field grid of background stars to calibrate changing optical distortion and achieve microarcsecond astrometric precision on bright targets (Guyon et al. 2010). We describe applications of this concept to ground-based uncrowded astrometry using a diffractive, monopupil telescope and a wide-field camera to image as many as {approx}4000 background reference stars. Final relative astrometric precision is limited by differential tip/tilt jitter caused by high altitude layers of turbulence. A diffractive 3-meter telescope is capable of reaching {approx}35 {micro}as relative astrometric error per coordinate perpendicular to the zenith vector in three hours on a bright target star (I < 10) in fields of moderate stellar density ({approx}40 stars arcmin{sup -2} with I < 23). Smaller diffractive apertures (D < 1 m) can achieve 100-200 {micro}as performance with the same stellar density and exposure time and a large telescope (6.5-10 m) could achieve as low as 10 {micro}as, nearly an order of magnitude better than current space-based facilities. The diffractive pupil enables the use of larger fields of view through calibration of changing optical distortion as well as brighter target stars (V < 6) by preventing star saturation. Permitting the sky to naturally roll to average signals over many thousands of pixels can mitigate the effects of detector imperfections.

79 ASTRONOMY AND ASTROPHYSICS↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗